Hao-Ran Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hao-Ran Yang has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Mao Chen
Department of Cardiology, West China Hospital, Sichuan University, Chengdu 610041, China
3 shared publications - Hongde Li
Laboratory of Cardiac Structure and Function, Institute of Cardiovascular Diseases, West China Hospital, Sichuan University, Chengdu 610041, P.R. China
2 shared publications - Tian-Yuan Xiong
Sichuan University
2 shared publications Xi Wang
Department of Cardiology West China Hospital, Sichuan University Chengdu People’s Republic of China
2 shared publications- Yong Peng
Department of Cardiology, West China Hospital, Sichuan University, Chengdu 610041, China
2 shared publications - Zhen-Gang Zhao
Department of Cardiology, West China Hospital, Sichuan University, Chengdu 610041, China
2 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by Wiley in Cardiovascular Therapeutics
- Vol. 2025 (1) , 3845211
Thrombospondin‐1 Silencing Ameliorates Osteoblastic Differentiation of Aortic Valve Interstitial Cells via Inhibiting Nuclear Factor‐ κ B Pathway
Objective: Calcific aortic valve disease (CAVD) is a progressive cardiovascular condition driven by the osteogenic differentiation of valve interstitial cells (VICs), with no effective drug therapies currently available. Hence, our objective is to investigate the impact of thrombospondin‐1 (TSP‐1) silencing on CAVD progression. Methods: In vitro experiments were employed using human primary VICs with TSP‐1 knockdown, cultured in osteogenic induction medium, and followed by analyses including western blot, alkaline phosphatase staining, alizarin red staining, immunofluorescence, and flow cytometry. In vivo experiments used two murine models of CAVD to determine the role of TSP‐1 silencing on aortic valve calcification. Results: We observed that silencing of TSP‐1 reduced the osteogenic differentiation of VICs. Subsequent experiments demonstrated that TSP‐1 knockdown suppressed nuclear factor‐ κ B (NF‐ κ B)–mediated inflammation during osteoblastic differentiation of VICs. Consistent findings were also observed in two murine models of CAVD. Conclusions: The present study has shown that TSP‐1 silencing could mitigate the development of CAVD by inhibiting NF‐ κ B‐mediated inflammation. We propose that targeting TSP‐1‐mediated NF‐ κ B pathway could provide a potential therapeutic method for treating CAVD.
- 1 January 2025
- Published by Wiley in Cardiovascular Therapeutics
- Vol. 2025 (1) , 3845211
Open AccessThrombospondin‐1 Silencing Ameliorates Osteoblastic Differentiation of Aortic Valve Interstitial Cells via Inhibiting Nuclear Factor‐ κ B Pathway
Objective: Calcific aortic valve disease (CAVD) is a progressive cardiovascular condition driven by the osteogenic differentiation of valve interstitial cells (VICs), with no effective drug therapies currently available. Hence, our objective is to investigate the impact of thrombospondin‐1 (TSP‐1) silencing on CAVD progression. Methods: In vitro experiments were employed using human primary VICs with TSP‐1 knockdown, cultured in osteogenic induction medium, and followed by analyses including western blot, alkaline phosphatase staining, alizarin red staining, immunofluorescence, and flow cytometry. In vivo experiments used two murine models of CAVD to determine the role of TSP‐1 silencing on aortic valve calcification. Results: We observed that silencing of TSP‐1 reduced the osteogenic differentiation of VICs. Subsequent experiments demonstrated that TSP‐1 knockdown suppressed nuclear factor‐ κ B (NF‐ κ B)–mediated inflammation during osteoblastic differentiation of VICs. Consistent findings were also observed in two murine models of CAVD. Conclusions: The present study has shown that TSP‐1 silencing could mitigate the development of CAVD by inhibiting NF‐ κ B‐mediated inflammation. We propose that targeting TSP‐1‐mediated NF‐ κ B pathway could provide a potential therapeutic method for treating CAVD.
- Open Access
- 29 October 2024
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (21) , e035772
Long‐Term Durability of Transcatheter Aortic Valve Prostheses in Patients With Bicuspid Versus Tricuspid Aortic Valve
Background: Currently, there is a lack of evidence for the long‐term bioprosthetic valve durability of patients with bicuspid aortic valve (BAV) following transcatheter aortic valve replacement (TAVR). Methods and Results: This study aimed to evaluate hemodynamic outcome, structural valve deterioration, and bioprosthetic valve failure during long‐term follow‐up after TAVR in patients with BAV versus patients with tricuspid aortic valve (TAV). Patients with BAV and TAV who underwent TAVR between 2012 and 2020, with echocardiography followed for at least 3 years, were included. Baseline characteristics, long‐term valve hemodynamic performance, structural valve deterioration, and bioprosthetic valve failure were compared between patients with BAV and TAV. A total of 170 patients with BAV and 145 patients with TAV were included. The mean duration of follow‐up for patients with BAV and TAV was 5.2±1.8 and 5.0±1.7 years. No significant differences were observed in the rates of structural valve deterioration and bioprosthetic valve failure between patients with BAV and TAV: structural valve deterioration, BAV 20 (11.8%) versus TAV 16 (11.0%) at last follow‐up ( P =0.861); bioprosthetic valve failure, BAV 3 (1.8%) versus TAV 7 (4.8%) at last follow‐up ( P =0.196). More than moderate intravalvular aortic regurgitation (1.8% versus 4.8%, P =0.196) and paravalvular leak (6.5% versus 3.4%, P =0.305) were rare in both patients with BAV and patients with TAV. Conclusions: This study indicated satisfactory long‐term valve durability of TAVR in patients with BAV. Comparable hemodynamic outcome, structural valve deterioration, and bioprosthetic valve failure could be achieved in patients with BAV and TAV during long‐term follow‐up after TAVR.
- 29 October 2024
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (21) , e035772
Open AccessLong‐Term Durability of Transcatheter Aortic Valve Prostheses in Patients With Bicuspid Versus Tricuspid Aortic Valve
Background: Currently, there is a lack of evidence for the long‐term bioprosthetic valve durability of patients with bicuspid aortic valve (BAV) following transcatheter aortic valve replacement (TAVR). Methods and Results: This study aimed to evaluate hemodynamic outcome, structural valve deterioration, and bioprosthetic valve failure during long‐term follow‐up after TAVR in patients with BAV versus patients with tricuspid aortic valve (TAV). Patients with BAV and TAV who underwent TAVR between 2012 and 2020, with echocardiography followed for at least 3 years, were included. Baseline characteristics, long‐term valve hemodynamic performance, structural valve deterioration, and bioprosthetic valve failure were compared between patients with BAV and TAV. A total of 170 patients with BAV and 145 patients with TAV were included. The mean duration of follow‐up for patients with BAV and TAV was 5.2±1.8 and 5.0±1.7 years. No significant differences were observed in the rates of structural valve deterioration and bioprosthetic valve failure between patients with BAV and TAV: structural valve deterioration, BAV 20 (11.8%) versus TAV 16 (11.0%) at last follow‐up ( P =0.861); bioprosthetic valve failure, BAV 3 (1.8%) versus TAV 7 (4.8%) at last follow‐up ( P =0.196). More than moderate intravalvular aortic regurgitation (1.8% versus 4.8%, P =0.196) and paravalvular leak (6.5% versus 3.4%, P =0.305) were rare in both patients with BAV and patients with TAV. Conclusions: This study indicated satisfactory long‐term valve durability of TAVR in patients with BAV. Comparable hemodynamic outcome, structural valve deterioration, and bioprosthetic valve failure could be achieved in patients with BAV and TAV during long‐term follow‐up after TAVR.
- 1 December 2023
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 16 (12) , e013083
Outcomes Following Transcatheter Aortic Valve Replacement for Aortic Stenosis in Patients With Type 0 Bicuspid, Type 1 Bicuspid, and Tricuspid Aortic Valves
BACKGROUND: Data concerning the outcomes of transcatheter aortic valve replacement in type 0 bicuspid aortic stenosis (AS) are scarce. The study aims to compare the outcomes of transcatheter aortic valve replacement for AS in patients with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy. METHODS: We enrolled consecutive patients undergoing transcatheter aortic valve replacement for severe AS between 2012 and 2022 in this single-center retrospective cohort study. The primary outcome was mortality, while secondary outcomes included in-hospital complications such as stroke and pacemaker implantation and transcatheter heart valve hemodynamic performance. RESULTS: The number of patients with AS with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy was 328, 302, and 642, respectively. Self-expanding transcatheter heart valves were used in the majority of patients (n=1160; 91.4%). In the matched population, differences in mortality (30 days: 4.2% versus 1.7% versus 1.7%, P overall =0.522; 1 year: 10% versus 2.3% versus 6.2%, P overall =0.099) and all stroke (30 days: 1.0% versus 0.9% versus 0.0%, P overall =0.765; 1 year: 1.4% versus 1.6% versus 1.3%, P overall =NS) were nonsignificant, and the incidence of overall in-hospital complications was comparable among groups. Ascending aortic diameter was the single predictor of 1-year mortality in type 0 bicuspid patients (hazard ratio, 1.59 [95% CI, 1.03–2.44]; P =0.035). The proportion of patients with a mean residual gradient ≥20 mm Hg was the highest in those with type 0 bicuspid anatomy, although the need for permanent pacemaker implantation was the lowest in this group. CONCLUSIONS: Major clinical outcomes of transcatheter aortic valve replacement for AS in patients with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy are equivalent at short- and mid-term follow-up. These observations merit further exploration in prospective international registries and randomized controlled trials.
- 1 December 2023
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 16 (12) , e013083
Outcomes Following Transcatheter Aortic Valve Replacement for Aortic Stenosis in Patients With Type 0 Bicuspid, Type 1 Bicuspid, and Tricuspid Aortic Valves
BACKGROUND: Data concerning the outcomes of transcatheter aortic valve replacement in type 0 bicuspid aortic stenosis (AS) are scarce. The study aims to compare the outcomes of transcatheter aortic valve replacement for AS in patients with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy. METHODS: We enrolled consecutive patients undergoing transcatheter aortic valve replacement for severe AS between 2012 and 2022 in this single-center retrospective cohort study. The primary outcome was mortality, while secondary outcomes included in-hospital complications such as stroke and pacemaker implantation and transcatheter heart valve hemodynamic performance. RESULTS: The number of patients with AS with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy was 328, 302, and 642, respectively. Self-expanding transcatheter heart valves were used in the majority of patients (n=1160; 91.4%). In the matched population, differences in mortality (30 days: 4.2% versus 1.7% versus 1.7%, P overall =0.522; 1 year: 10% versus 2.3% versus 6.2%, P overall =0.099) and all stroke (30 days: 1.0% versus 0.9% versus 0.0%, P overall =0.765; 1 year: 1.4% versus 1.6% versus 1.3%, P overall =NS) were nonsignificant, and the incidence of overall in-hospital complications was comparable among groups. Ascending aortic diameter was the single predictor of 1-year mortality in type 0 bicuspid patients (hazard ratio, 1.59 [95% CI, 1.03–2.44]; P =0.035). The proportion of patients with a mean residual gradient ≥20 mm Hg was the highest in those with type 0 bicuspid anatomy, although the need for permanent pacemaker implantation was the lowest in this group. CONCLUSIONS: Major clinical outcomes of transcatheter aortic valve replacement for AS in patients with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy are equivalent at short- and mid-term follow-up. These observations merit further exploration in prospective international registries and randomized controlled trials.