Ondřej Hlaváček
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ondřej Hlaváček has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Alice Vagenknechtová
Faculty of Environmental technology, University of Chemistry and Technology, Prague
3 shared publications - Zdeněk Beňo
Faculty of Environmental technology, University of Chemistry and Technology, Prague
2 shared publications A. Vagenknechtová
Department of Sustainable Fuels and Green Chemistry, University of Chemistry and Technology Prague, Prague, Czech Republic
1 shared publicationAlice Vagenknechtová
Faculty of Environmental technology, University of Chemistry and Technology, Prague
1 shared publicationAnatoli Shestak
University of Chemistry and Technology, Prague
1 shared publication- Jan Hrdlička
Department of Energy Engineering, Faculty of Mechanical Engineering, Czech Technical University in Prague, Technicka 4, 166 07 Prague, Czech Republic
1 shared publication
Latest Publications
- Open Access
- 31 December 2025
- Published by University of Chemistry and Technology - Faculty of Environmental Technology in Paliva
- p. 71
Construction and testing of the combined adsorption-methanation unit
Possibilities for partial utilization of carbon dioxide, which is produced by burning fossil fuels, biomass, waste, etc., have been recently sought. The Power-to-Gas (P2G) conception, in which the captured CO2 is converted into methane using hydrogen produced from nonfossil sources, such as water electrolysis using surplus electricity in distribution networks, is one of the ways. However, surplus energy fluctuates strongly during the day and calendar year, which negatively affects the efficiency and financial return of P2G. The article is devoted to the development of a test unit that allows capturing CO2 from flue gases and converting it in-situ to methane (in the same reactor), if an adequate amount of hydrogen is available. Conversely, in the event of H2 shortage, the system produces concentrated CO2 suitable for compression and, for example, geological storage. The paper contains a detailed description of the self-designed test stand, which both simulates the conditions in the considered real operating facility very well (at the TRL 5 level) and is compact enough to be easily transported as a single module to an industrial source of flue gases. Two adsorbents/catalysts based on nickel-modified substrates gamma−Al2O3 and Envisorb B+ were developed. After preliminary laboratory tests including measurements of adsorption capacities, structural stability, optimization of working media dosing, etc., the system was transported to the Ško-Energo, s.r.o. plant. After the installation and activation of the stand and all peripherals, intensive tests are underway at the time of publication of the paper, which verify the laboratory results and will allow the level of technological readiness to be increased to the TRL6 value within the framework of subsequent development. However, the first phase of testing has already provided valuable data on the unit and the designed sorbents/catalysts..The stand has proven to be fully functional in terms of combining CO2 adsorption and its subsequent reaction to methane within a single reactor. The gamma−Al2O3-based sorbent/catalyst showed promising conversion at an average of 72%. In contrast, the material prepared from the commercial adsorbent Envisorb B+ proved unsuitable for the given purpose with a conversion of 2.8% only. Further tests will address the improvement of the still low adsorption capacity (approximately 0.5% by weight) by switching to a higher-pressure level than the atmospheric one used so far.
- 31 December 2025
- Published by University of Chemistry and Technology - Faculty of Environmental Technology in Paliva
- p. 71
Open AccessConstruction and testing of the combined adsorption-methanation unit
Possibilities for partial utilization of carbon dioxide, which is produced by burning fossil fuels, biomass, waste, etc., have been recently sought. The Power-to-Gas (P2G) conception, in which the captured CO2 is converted into methane using hydrogen produced from nonfossil sources, such as water electrolysis using surplus electricity in distribution networks, is one of the ways. However, surplus energy fluctuates strongly during the day and calendar year, which negatively affects the efficiency and financial return of P2G. The article is devoted to the development of a test unit that allows capturing CO2 from flue gases and converting it in-situ to methane (in the same reactor), if an adequate amount of hydrogen is available. Conversely, in the event of H2 shortage, the system produces concentrated CO2 suitable for compression and, for example, geological storage. The paper contains a detailed description of the self-designed test stand, which both simulates the conditions in the considered real operating facility very well (at the TRL 5 level) and is compact enough to be easily transported as a single module to an industrial source of flue gases. Two adsorbents/catalysts based on nickel-modified substrates gamma−Al2O3 and Envisorb B+ were developed. After preliminary laboratory tests including measurements of adsorption capacities, structural stability, optimization of working media dosing, etc., the system was transported to the Ško-Energo, s.r.o. plant. After the installation and activation of the stand and all peripherals, intensive tests are underway at the time of publication of the paper, which verify the laboratory results and will allow the level of technological readiness to be increased to the TRL6 value within the framework of subsequent development. However, the first phase of testing has already provided valuable data on the unit and the designed sorbents/catalysts..The stand has proven to be fully functional in terms of combining CO2 adsorption and its subsequent reaction to methane within a single reactor. The gamma−Al2O3-based sorbent/catalyst showed promising conversion at an average of 72%. In contrast, the material prepared from the commercial adsorbent Envisorb B+ proved unsuitable for the given purpose with a conversion of 2.8% only. Further tests will address the improvement of the still low adsorption capacity (approximately 0.5% by weight) by switching to a higher-pressure level than the atmospheric one used so far.
- Open Access
- 4 December 2025
- Published by Springer Nature in International Journal of Environmental Science and Technology
- Vol. 23 (2) , 118
Soda-based sorbents for HCl removal in the DSI system for agricultural biomass Co-combustion at an industrial scale
One of the significant issues of agricultural biomass combustion is its higher chlorine content that can lead to exceeding the emission limits. Dry-sorbent-injection (DSI) systems based on acid-gas sorption enable efficient acid-gas removal, and there are several types of commercially available sorbent that can be used in this technology. This article focusses on evaluation of the performance of soda-based sorbents for the removal of chlorine from the flue gas from agricultural biomass co-combustion and demonstrates their advantages over commonly used hydrated lime sorbents. Analysing both the operational efficiency and the potential for optimization, this research contributes valuable information to the development of more sustainable and cleaner biomass combustion technologies. The article includes a comparison of soda-based sorbents and their use for the removal of chlorine from flue gas and compares with previous findings on hydrated lime sorbents. The samples were determined in detail in a laboratory. The core of the article is based on full-scale industrial testing on a commercial 140 t/h CFB heating plant boiler. In operational tests, soda-based sorbents achieved, under the same conditions, a higher HCl removal efficiency (90.93 vs. 84.66%) and a lower specific sorbent consumption (0.87 and 0.91 vs. 2.58 and 5.59 m 3 sorbent ·t Cl −1 for hydrated lime sorbents. The behaviour of the system during tests has also revealed further possibilities to reduce soda consumption by modifying the control system logic and dosing systems. The results have shown that soda-based sorbents are a promising alternative to commonly used hydrated lime sorbents.
- 4 December 2025
- Published by Springer Nature in International Journal of Environmental Science and Technology
- Vol. 23 (2) , 118
Open AccessSoda-based sorbents for HCl removal in the DSI system for agricultural biomass Co-combustion at an industrial scale
One of the significant issues of agricultural biomass combustion is its higher chlorine content that can lead to exceeding the emission limits. Dry-sorbent-injection (DSI) systems based on acid-gas sorption enable efficient acid-gas removal, and there are several types of commercially available sorbent that can be used in this technology. This article focusses on evaluation of the performance of soda-based sorbents for the removal of chlorine from the flue gas from agricultural biomass co-combustion and demonstrates their advantages over commonly used hydrated lime sorbents. Analysing both the operational efficiency and the potential for optimization, this research contributes valuable information to the development of more sustainable and cleaner biomass combustion technologies. The article includes a comparison of soda-based sorbents and their use for the removal of chlorine from flue gas and compares with previous findings on hydrated lime sorbents. The samples were determined in detail in a laboratory. The core of the article is based on full-scale industrial testing on a commercial 140 t/h CFB heating plant boiler. In operational tests, soda-based sorbents achieved, under the same conditions, a higher HCl removal efficiency (90.93 vs. 84.66%) and a lower specific sorbent consumption (0.87 and 0.91 vs. 2.58 and 5.59 m 3 sorbent ·t Cl −1 for hydrated lime sorbents. The behaviour of the system during tests has also revealed further possibilities to reduce soda consumption by modifying the control system logic and dosing systems. The results have shown that soda-based sorbents are a promising alternative to commonly used hydrated lime sorbents.
- Open Access
- 19 December 2024
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 47 (1) , 642-656
The use of waste limestone from paint shops for flue-gas desulfurization
- 19 December 2024
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 47 (1) , 642-656
Open AccessThe use of waste limestone from paint shops for flue-gas desulfurization
- Open Access
- 30 September 2024
- Published by University of Chemistry and Technology - Faculty of Environmental Technology in Paliva
- p. 74-82
Comparison of DeNOx additives in SNCR fluidized bed boiler system
Due to decreasing BAT emission limits of NOx the owners of heating plant are looking for DeNOx solution, especially by solid fuel firing boilers. Fluidized-bed boil-ers combustion temperature is generally lower, and some primary precautions were sufficient. Nowadays lots of plants install secondary precautions (especially SNCR) into their boilers due to increasing periods of exceeding emission NOx limits. The article is about comparison of water solution of urea (41 % wt.), ammonium sulfate (33 % wt.) and am-monia (22 % wt.) and their utilization in SNCR technol-ogy. Laboratory determination specified exact content of functional substance and content of redox nitrogen. Also, significant content of heavy metals was not detected. Operational tests were realized in CFB coal-biomass boiler (steam parameters: 140 t·h-1, 525 °C, 12.5 MPa). Dosing of DeNOx additives were only during boiler per-formance higher than 92 %, for lower performance pri-mary precautions were sufficient. There was higher tem-perature through the combustion chamber during active SNCR dosing (877 °C, standard temperature 850 °C), alt-hough the amount of combustion air was increased. Com-plication connected with high emission of NH3 was not detected. Lower emission of CO was also detected. All three additives are suitable for application in SNCR technology. To reach emission limits were needed 3.7 l·h-1 of ammonia solution, 5.04 l·h-1 of urea solution and 5.74 l·h-1 of ammonium sulfate solution. After recal-culation it means 0.65 kg·h-1 (ammonia), 1.1 kg·h-1 (urea) and 0,38 kg·h-1 (ammonium sulfate) of redox nitrogen content.
- 30 September 2024
- Published by University of Chemistry and Technology - Faculty of Environmental Technology in Paliva
- p. 74-82
Open AccessComparison of DeNOx additives in SNCR fluidized bed boiler system
Due to decreasing BAT emission limits of NOx the owners of heating plant are looking for DeNOx solution, especially by solid fuel firing boilers. Fluidized-bed boil-ers combustion temperature is generally lower, and some primary precautions were sufficient. Nowadays lots of plants install secondary precautions (especially SNCR) into their boilers due to increasing periods of exceeding emission NOx limits. The article is about comparison of water solution of urea (41 % wt.), ammonium sulfate (33 % wt.) and am-monia (22 % wt.) and their utilization in SNCR technol-ogy. Laboratory determination specified exact content of functional substance and content of redox nitrogen. Also, significant content of heavy metals was not detected. Operational tests were realized in CFB coal-biomass boiler (steam parameters: 140 t·h-1, 525 °C, 12.5 MPa). Dosing of DeNOx additives were only during boiler per-formance higher than 92 %, for lower performance pri-mary precautions were sufficient. There was higher tem-perature through the combustion chamber during active SNCR dosing (877 °C, standard temperature 850 °C), alt-hough the amount of combustion air was increased. Com-plication connected with high emission of NH3 was not detected. Lower emission of CO was also detected. All three additives are suitable for application in SNCR technology. To reach emission limits were needed 3.7 l·h-1 of ammonia solution, 5.04 l·h-1 of urea solution and 5.74 l·h-1 of ammonium sulfate solution. After recal-culation it means 0.65 kg·h-1 (ammonia), 1.1 kg·h-1 (urea) and 0,38 kg·h-1 (ammonium sulfate) of redox nitrogen content.
- Open Access
- 23 August 2024
- Published by Springer Nature in Water Conservation Science and Engineering
- Vol. 9 (2) , 1-11
Reduction of Water Consumption for Heating Plant Cooling with an Indirect Cooling System
In order to combat drought, many industrial companies are taking austerity measures in their water management. They are driven not only by economic reasons but also by tightening legislation, directly prohibiting the extraction of water from the environment when a drought is declared. The article deals with the case of a company that operates a heating plant for an industrial zone and the adjacent town. The water source is a river 2.5 km away. In the event of a drought, the company is affected by a ban on river-water extraction, which has a direct impact on the operation of the heating plant and the entire industrial zone, with the current heating-plant cooling system consuming up to 60% of the industrial water. Previous studies have shown the impossibility of installing a dry or hybrid cooling system in the area. A possible economical option is closed-loop cooling. Most of the cooling water is lost by evaporation, the rest by surface blowdown, neither of which occurs in a closed circuit. This paper deals with an alternative closed cooling system using a river and its design parameter calculation, including a comparison of the different options for pipe location and routing.
- 23 August 2024
- Published by Springer Nature in Water Conservation Science and Engineering
- Vol. 9 (2) , 1-11
Open AccessReduction of Water Consumption for Heating Plant Cooling with an Indirect Cooling System
In order to combat drought, many industrial companies are taking austerity measures in their water management. They are driven not only by economic reasons but also by tightening legislation, directly prohibiting the extraction of water from the environment when a drought is declared. The article deals with the case of a company that operates a heating plant for an industrial zone and the adjacent town. The water source is a river 2.5 km away. In the event of a drought, the company is affected by a ban on river-water extraction, which has a direct impact on the operation of the heating plant and the entire industrial zone, with the current heating-plant cooling system consuming up to 60% of the industrial water. Previous studies have shown the impossibility of installing a dry or hybrid cooling system in the area. A possible economical option is closed-loop cooling. Most of the cooling water is lost by evaporation, the rest by surface blowdown, neither of which occurs in a closed circuit. This paper deals with an alternative closed cooling system using a river and its design parameter calculation, including a comparison of the different options for pipe location and routing.
- Open Access
- 31 March 2024
- Published by University of Chemistry and Technology - Faculty of Environmental Technology in Paliva
- p. 30-36
Comparison of properties of brown coal and bio-mass-based substitute fuels
- 31 March 2024
- Published by University of Chemistry and Technology - Faculty of Environmental Technology in Paliva
- p. 30-36
Open AccessComparison of properties of brown coal and bio-mass-based substitute fuels
- Open Access
- 31 March 2024
- Published by University of Chemistry and Technology - Faculty of Environmental Technology in Paliva
- p. 1-8
Effects of thermal disposal of oil-water residues on operation heating plant boiler
- 31 March 2024
- Published by University of Chemistry and Technology - Faculty of Environmental Technology in Paliva
- p. 1-8
Open AccessEffects of thermal disposal of oil-water residues on operation heating plant boiler
- Open Access
- 31 March 2024
- Published by University of Chemistry and Technology - Faculty of Environmental Technology in Paliva
- p. 9-15
Use of solid recovered fuels for heat production - analysis of Czech legislation
The article is about solid recovered fuel (SRF) and its legislation possibilities to use them as a fuel in heating plants. This solution is quite popular because it brings solution of two very problematic tasks – the decreasing of waste landfilling and the end of fossil fuel (especially coal) combustion. Due to these arguments are there many producers which offer SRF (often in the pellets form) to conventional heating plants. However heating plant have flue gas cleaning technologies, which are able to combustion SRF and keep current emissions limits, the usage of SRF is forbidden for them. The reason is in the classification of origin material as a waste and the permission and limits as a waste combustion is required. The criteria and limits for waste combustion are much stricter and for heating plants is very difficult to reach them if it is possible. The article is about view of Czech legislation, where some of law had different interpretation about waste material and SRF combustion. Article compare requirements and results for SRF from waste and SRF from waste biomass. The interpretation is described from a view of waste, air protection, IPPC, EU ETS and support of renewable energy sources law based on Czech a EU law documents. The most important is origin of SRF. When the SRF is made by waste (municipal or industrial) all laws must assess final combustion technology as waste combustion technology, the support for renewable energy sources is not allowed (except biodegradable municipal waste) and CO2 emission permit is not required. With new regulation No. 169/2023 Coll. is possible to combustion SRF, which is based on waste biomass from forestry and agriculture. The permits and limits for combustion plants are same as biomass combustion, support for renewably energy sources is possible and CO2 emission permits are not required. Investment to SRF combustion technology is not advantageous, because purchase prize of SRF will be higher than standard waste but requirements for technology will be same. Meaning of the newest legislation was not in possibilities to use of more SRF in heating plant, but bring waste and air protection law into accord, because some of waste biomass was possible to combust, however it was waste by waste law.
- 31 March 2024
- Published by University of Chemistry and Technology - Faculty of Environmental Technology in Paliva
- p. 9-15
Open AccessUse of solid recovered fuels for heat production - analysis of Czech legislation
The article is about solid recovered fuel (SRF) and its legislation possibilities to use them as a fuel in heating plants. This solution is quite popular because it brings solution of two very problematic tasks – the decreasing of waste landfilling and the end of fossil fuel (especially coal) combustion. Due to these arguments are there many producers which offer SRF (often in the pellets form) to conventional heating plants. However heating plant have flue gas cleaning technologies, which are able to combustion SRF and keep current emissions limits, the usage of SRF is forbidden for them. The reason is in the classification of origin material as a waste and the permission and limits as a waste combustion is required. The criteria and limits for waste combustion are much stricter and for heating plants is very difficult to reach them if it is possible. The article is about view of Czech legislation, where some of law had different interpretation about waste material and SRF combustion. Article compare requirements and results for SRF from waste and SRF from waste biomass. The interpretation is described from a view of waste, air protection, IPPC, EU ETS and support of renewable energy sources law based on Czech a EU law documents. The most important is origin of SRF. When the SRF is made by waste (municipal or industrial) all laws must assess final combustion technology as waste combustion technology, the support for renewable energy sources is not allowed (except biodegradable municipal waste) and CO2 emission permit is not required. With new regulation No. 169/2023 Coll. is possible to combustion SRF, which is based on waste biomass from forestry and agriculture. The permits and limits for combustion plants are same as biomass combustion, support for renewably energy sources is possible and CO2 emission permits are not required. Investment to SRF combustion technology is not advantageous, because purchase prize of SRF will be higher than standard waste but requirements for technology will be same. Meaning of the newest legislation was not in possibilities to use of more SRF in heating plant, but bring waste and air protection law into accord, because some of waste biomass was possible to combust, however it was waste by waste law.
- Open Access
- 30 September 2023
- Published by University of Chemistry and Technology - Faculty of Environmental Technology in Paliva
- p. 92-100
Comparison of sorbents based on Ca(OH)2 for removing HCl from flue gas
- 30 September 2023
- Published by University of Chemistry and Technology - Faculty of Environmental Technology in Paliva
- p. 92-100
Open AccessComparison of sorbents based on Ca(OH)2 for removing HCl from flue gas