Jian Qiu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jian Qiu has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
- Kefu Liu
College of Intelligent Robotics and Advanced Manufacturing, Fudan University, Shanghai 200433, China
27 shared publications - Hui Zhao
College of Intelligent Robotics and Advanced Manufacturing, Fudan University, Shanghai 200433, China
24 shared publications - Teng Long
Department of Engineering, University of Cambridge, Cambridge, UK
6 shared publications - Chaoqiang Jiang
City University of Hong Kong
5 shared publications - Shuo Wang
University of Florida, Gainesville, FL, USA
5 shared publications Xiaonan Tao
5 shared publications
Latest Publications
- Open Access
- 13 November 2026
- Published by MDPI AG in Electronics
- Vol. 15 (22) , 5283
An H-Bridge-Based Battery ACIR Measurement System with Energy Recovery
Conventional battery alternating current internal resistance (ACIR) measurement faces challenges in generating adjustable high-current excitation with low energy dissipation and accurately acquiring weak alternating current (AC) voltage responses. This paper proposes an H-bridge-based battery ACIR measurement system with energy recovery. The battery under test directly supplies the excitation energy, enabling bidirectional energy transfer through the H-bridge and an energy-storage inductor. Fixed-frequency phase-shift modulation generates amplitude-adjustable bidirectional test currents at 1 kHz. An active direct current (DC) offset-cancelation sensing architecture improves analog-to-digital converter (ADC) input-range utilization for millivolt-level AC voltage responses, while a single-bin discrete Fourier transform (DFT) extracts the 1 kHz fundamental components for ACIR calculation. At measured peak test currents of 20, 100, and 400 mA, the charge return ratios were 8.53%, 9.81%, and 12.49%, respectively. Under the constant-terminal-voltage approximation, these values also estimate the fraction of energy drawn from the battery that was returned to it during the same excitation cycle. During 15 min repeated measurements, the proposed system exhibited lower apparent temperatures than the comparison instruments under the respective test conditions, with no detectable change in battery open-circuit voltage at the reported resolution. For the same conditioned signal, the 1 kHz fundamental voltage amplitude obtained from the ADC samples was 2.34% lower than the oscilloscope result. After channel calibration, the proposed system measured the 1 kHz ACIR of seven lithium-ion cells using the 20 and 100 mA excitation settings. Across the seven cells, the maximum and mean absolute relative deviations were 3.50% and 1.60%, respectively, relative to the VICTOR 3540, and 2.65% and 1.26%, respectively, relative to the FNIRSI HRM-10.
- 13 November 2026
- Published by MDPI AG in Electronics
- Vol. 15 (22) , 5283
Open AccessAn H-Bridge-Based Battery ACIR Measurement System with Energy Recovery
Conventional battery alternating current internal resistance (ACIR) measurement faces challenges in generating adjustable high-current excitation with low energy dissipation and accurately acquiring weak alternating current (AC) voltage responses. This paper proposes an H-bridge-based battery ACIR measurement system with energy recovery. The battery under test directly supplies the excitation energy, enabling bidirectional energy transfer through the H-bridge and an energy-storage inductor. Fixed-frequency phase-shift modulation generates amplitude-adjustable bidirectional test currents at 1 kHz. An active direct current (DC) offset-cancelation sensing architecture improves analog-to-digital converter (ADC) input-range utilization for millivolt-level AC voltage responses, while a single-bin discrete Fourier transform (DFT) extracts the 1 kHz fundamental components for ACIR calculation. At measured peak test currents of 20, 100, and 400 mA, the charge return ratios were 8.53%, 9.81%, and 12.49%, respectively. Under the constant-terminal-voltage approximation, these values also estimate the fraction of energy drawn from the battery that was returned to it during the same excitation cycle. During 15 min repeated measurements, the proposed system exhibited lower apparent temperatures than the comparison instruments under the respective test conditions, with no detectable change in battery open-circuit voltage at the reported resolution. For the same conditioned signal, the 1 kHz fundamental voltage amplitude obtained from the ADC samples was 2.34% lower than the oscilloscope result. After channel calibration, the proposed system measured the 1 kHz ACIR of seven lithium-ion cells using the 20 and 100 mA excitation settings. Across the seven cells, the maximum and mean absolute relative deviations were 3.50% and 1.60%, respectively, relative to the VICTOR 3540, and 2.65% and 1.26%, respectively, relative to the FNIRSI HRM-10.
- Open Access
- 4 November 2026
- Published by MDPI AG in Electronics
- Vol. 15 (21) , 5124
A High-Efficiency Bipolar Pulse Generator Based on a Push–Pull Inverter for Tissue Welding
The push–pull inverter topology inherently incorporates a transformer, making it suitable for electrosurgical generators without requiring an additional transformer. However, conventional push–pull topologies exhibit limitations, including high switch stress and the absence of a dedicated path for releasing transformer leakage-inductance energy, which may increase switching losses at high frequencies. This paper presents a bipolar pulse generator based on a push–pull inverter topology, offering a new engineering approach for electrosurgical applications. The prototype achieves soft-switching operation over a load range of 30–1000 Ω, reducing design complexity, extending load adaptability, and improving system reliability while meeting the stringent pulse-width control requirements of bipolar electrosurgical applications. In addition, based on an equivalent-impedance model of tissue welding, the operating modes and soft-switching mechanisms of the push–pull inverter under different dynamic load conditions are analyzed, and strict constraints relating to dead time, load resistance, and circuit parameters are derived. A bipolar pulse-generator prototype operating at 400 kHz was developed to validate the theoretical analysis. Experimental results show a conversion efficiency of 86–94% over a dynamic load range of 25–250 Ω. At a moderate nominal load, the system maintains an efficiency above 93% over an output-power range of 4.92–183.69 W, achieving high-efficiency operation across a power range relevant to electrosurgical applications. While maintaining tissue-welding quality, the proposed system improves overall efficiency, demonstrating the feasibility and engineering value of the topology and control strategy for bipolar electrosurgical generators.
- 4 November 2026
- Published by MDPI AG in Electronics
- Vol. 15 (21) , 5124
Open AccessA High-Efficiency Bipolar Pulse Generator Based on a Push–Pull Inverter for Tissue Welding
The push–pull inverter topology inherently incorporates a transformer, making it suitable for electrosurgical generators without requiring an additional transformer. However, conventional push–pull topologies exhibit limitations, including high switch stress and the absence of a dedicated path for releasing transformer leakage-inductance energy, which may increase switching losses at high frequencies. This paper presents a bipolar pulse generator based on a push–pull inverter topology, offering a new engineering approach for electrosurgical applications. The prototype achieves soft-switching operation over a load range of 30–1000 Ω, reducing design complexity, extending load adaptability, and improving system reliability while meeting the stringent pulse-width control requirements of bipolar electrosurgical applications. In addition, based on an equivalent-impedance model of tissue welding, the operating modes and soft-switching mechanisms of the push–pull inverter under different dynamic load conditions are analyzed, and strict constraints relating to dead time, load resistance, and circuit parameters are derived. A bipolar pulse-generator prototype operating at 400 kHz was developed to validate the theoretical analysis. Experimental results show a conversion efficiency of 86–94% over a dynamic load range of 25–250 Ω. At a moderate nominal load, the system maintains an efficiency above 93% over an output-power range of 4.92–183.69 W, achieving high-efficiency operation across a power range relevant to electrosurgical applications. While maintaining tissue-welding quality, the proposed system improves overall efficiency, demonstrating the feasibility and engineering value of the topology and control strategy for bipolar electrosurgical generators.
- 15 April 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (12) , 3982-3991
Correlation-based LiDAR wind sensing using SiPM: methodology and indoor validation
Cross-correlation wind LiDAR estimates wind speed by tracking advected aerosol-backscatter texture, enabling compact, cost-effective systems using intensity returns only. We evaluate silicon photomultiplier (SiPM) processing for this task using a dual-beam, single-receiver architecture by comparing two in-gate intensity estimators: peak amplitude and pulse area. A Monte Carlo SiPM response model is used to compare the two estimators at the device-readout level in the linear-counting regime, and indoor fog-tunnel experiments are used separately to evaluate wind-retrieval performance at the system level. Over the tested ( U ref , N ) plane, it achieves a lower mean relative retrieval error (8.75% versus 9.81%) and a larger fraction of operating points below 10% relative error (74.18% versus 62.64%). Under the tested near-linear operating conditions, these results provide quantitative guidance for observable selection in SiPM-based correlation wind retrieval and support the feasibility of compact, fixed-range implementations.
- 15 April 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (12) , 3982-3991
Correlation-based LiDAR wind sensing using SiPM: methodology and indoor validation
Cross-correlation wind LiDAR estimates wind speed by tracking advected aerosol-backscatter texture, enabling compact, cost-effective systems using intensity returns only. We evaluate silicon photomultiplier (SiPM) processing for this task using a dual-beam, single-receiver architecture by comparing two in-gate intensity estimators: peak amplitude and pulse area. A Monte Carlo SiPM response model is used to compare the two estimators at the device-readout level in the linear-counting regime, and indoor fog-tunnel experiments are used separately to evaluate wind-retrieval performance at the system level. Over the tested ( U ref , N ) plane, it achieves a lower mean relative retrieval error (8.75% versus 9.81%) and a larger fraction of operating points below 10% relative error (74.18% versus 62.64%). Under the tested near-linear operating conditions, these results provide quantitative guidance for observable selection in SiPM-based correlation wind retrieval and support the feasibility of compact, fixed-range implementations.
- Open Access
- 31 March 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (4) , 411
Ex Vivo Human Foreskin Tissue Circumcision via High-Frequency Electric Welding
Background: Despite the clinical significance of circumcision, traditional suturing is frequently compromised by intraoperative bleeding and lengthy recovery periods. While high-frequency electric welding (HFEW) presents a compelling alternative, its utility in foreskin removal procedures remains unexplored. Methods: Employing freshly excised human foreskin tissues, this study simulated the circumcision procedure to benchmark HFEW against standard suturing techniques. Critical performance metrics, encompassing tensile integrity, thermal injury scope, and operative efficiency, were rigorously quantified. Results: HFEW demonstrated exceptional time efficiency, averaging 2.01 ± 0.9 min—a 77.02% reduction relative to conventional suturing (p < 0.001). However, mechanical testing revealed disparities in tissue adhesion; the HFEW cohort recorded lower forces for initial tearing (4.42 ± 1.02 N) and complete rupture (6.15 ± 1.65 N) compared to the superior tensile resistance of the suturing group (7.91 ± 3.26 N and 14.22 ± 6.91 N, respectively). Conclusions: Although HFEW yields comparatively lower tensile strength, its remarkable operational efficiency positions it as a viable technical innovation for circumcision. These preliminary findings support the pursuit of further in vivo investigations to confirm its clinical applicability.
- 31 March 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (4) , 411
Open AccessEx Vivo Human Foreskin Tissue Circumcision via High-Frequency Electric Welding
Background: Despite the clinical significance of circumcision, traditional suturing is frequently compromised by intraoperative bleeding and lengthy recovery periods. While high-frequency electric welding (HFEW) presents a compelling alternative, its utility in foreskin removal procedures remains unexplored. Methods: Employing freshly excised human foreskin tissues, this study simulated the circumcision procedure to benchmark HFEW against standard suturing techniques. Critical performance metrics, encompassing tensile integrity, thermal injury scope, and operative efficiency, were rigorously quantified. Results: HFEW demonstrated exceptional time efficiency, averaging 2.01 ± 0.9 min—a 77.02% reduction relative to conventional suturing (p < 0.001). However, mechanical testing revealed disparities in tissue adhesion; the HFEW cohort recorded lower forces for initial tearing (4.42 ± 1.02 N) and complete rupture (6.15 ± 1.65 N) compared to the superior tensile resistance of the suturing group (7.91 ± 3.26 N and 14.22 ± 6.91 N, respectively). Conclusions: Although HFEW yields comparatively lower tensile strength, its remarkable operational efficiency positions it as a viable technical innovation for circumcision. These preliminary findings support the pursuit of further in vivo investigations to confirm its clinical applicability.
- Open Access
- 12 January 2026
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 112 (4) , 9320-9329
Comparative wound healing of intestinal anastomosis: high-frequency electric welding vs suture in a rabbit model
Background: This study aimed to comparatively evaluate the tissue healing characteristics of High-Frequency Electric Welding (HFEW) versus conventional suture techniques in intestinal side-to-side anastomosis using an animal model. Materials and methods: Intestinal side-to-side anastomoses were performed in New Zealand White rabbits using HFEW and hand-sewn techniques. Intraoperative assessment focused on procedure duration, hemostasis, and immediate anastomotic strength. Postoperative monitoring tracked vital signs, physiological parameters, healing progression (assessed via burst pressure), histopathological features, and inflammatory cell infiltration. Results: HFEW application reduced surgical duration and postoperative bleeding. Healing progression was comparable between HFEW and Suture groups. At 1 week postoperatively, vital signs and tissue strength normalized in experimental animals, with necrotic tissue replaced by regenerated tissue; Suture group specimens exhibited elevated inflammatory cell infiltration. By week 2, tissue strength further improved, inflammation subsided, and tissue morphology advanced. At 4 weeks, pathological structures in both HFEW and Suture groups closely resembled normal tissue. Compared with sutures, HFEW has advantages in terms of operating time and blood loss. During the postoperative healing phase, HFEW can effectively reduce the inflammatory response and accelerate healing. Conclusions: Postoperative healing with HFEW-based intestinal repair demonstrates comparability to manual suturing, while exhibiting reduced complication rates – offering residue-free foreign body anastomosis solution for laparoscopic surgery.
- 12 January 2026
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 112 (4) , 9320-9329
Open AccessComparative wound healing of intestinal anastomosis: high-frequency electric welding vs suture in a rabbit model
Background: This study aimed to comparatively evaluate the tissue healing characteristics of High-Frequency Electric Welding (HFEW) versus conventional suture techniques in intestinal side-to-side anastomosis using an animal model. Materials and methods: Intestinal side-to-side anastomoses were performed in New Zealand White rabbits using HFEW and hand-sewn techniques. Intraoperative assessment focused on procedure duration, hemostasis, and immediate anastomotic strength. Postoperative monitoring tracked vital signs, physiological parameters, healing progression (assessed via burst pressure), histopathological features, and inflammatory cell infiltration. Results: HFEW application reduced surgical duration and postoperative bleeding. Healing progression was comparable between HFEW and Suture groups. At 1 week postoperatively, vital signs and tissue strength normalized in experimental animals, with necrotic tissue replaced by regenerated tissue; Suture group specimens exhibited elevated inflammatory cell infiltration. By week 2, tissue strength further improved, inflammation subsided, and tissue morphology advanced. At 4 weeks, pathological structures in both HFEW and Suture groups closely resembled normal tissue. Compared with sutures, HFEW has advantages in terms of operating time and blood loss. During the postoperative healing phase, HFEW can effectively reduce the inflammatory response and accelerate healing. Conclusions: Postoperative healing with HFEW-based intestinal repair demonstrates comparability to manual suturing, while exhibiting reduced complication rates – offering residue-free foreign body anastomosis solution for laparoscopic surgery.
- 23 October 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (21) , 6590-6593
Coaxial dual-wavelength LiDAR system with GaN transparent detectors
This study proposed a dual-wavelength coaxial light detection and ranging (LiDAR) system leveraging the GaN transparent detector (GaN-TD), which is sensitive to violet light, while maintaining transparency to near-infrared (NIR) radiation. We employed modulated high-frequency pulsed NIR waves and fully modulated sinusoidal violet signals for precise target detection. Our system maintained high measurement precision, achieving millimeter-level precision at a 3.5-m range. The integration of scanning galvanometers into the coaxial configuration enabled the acquisition of high-accuracy distance images at 1.2 m. This research validated the feasibility and benefits of GaN-TD in dual-wavelength LiDAR systems, significantly advancing dual-wavelength LiDAR technology.
- 23 October 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (21) , 6590-6593
Coaxial dual-wavelength LiDAR system with GaN transparent detectors
This study proposed a dual-wavelength coaxial light detection and ranging (LiDAR) system leveraging the GaN transparent detector (GaN-TD), which is sensitive to violet light, while maintaining transparency to near-infrared (NIR) radiation. We employed modulated high-frequency pulsed NIR waves and fully modulated sinusoidal violet signals for precise target detection. Our system maintained high measurement precision, achieving millimeter-level precision at a 3.5-m range. The integration of scanning galvanometers into the coaxial configuration enabled the acquisition of high-accuracy distance images at 1.2 m. This research validated the feasibility and benefits of GaN-TD in dual-wavelength LiDAR systems, significantly advancing dual-wavelength LiDAR technology.
- 27 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (3) , 3117-3123
Effects of External DC B -Fields on High-Frequency Impedance Characteristics of Multilayer Ceramic Capacitors
Multilayer ceramic capacitors (MLCCs) are widely used in power electronics. Because paraelectric and ferroelectric material are nonmagnetic dielectrics, B-field effects are typically ignored in datasheets and design consideration. This letter reveals a significant, previously undocumented phenomenon: B-fields cause substantial high-frequency impedance variation in MLCCs, with observed changes exceeding 43% under B-fields up to 491 mT. Supplementary material includes all the design files for the measurement kit and all the raw data to ensure reproducibility. Raman spectroscopy and microstructure were employed to characterize the material composition and physical structure of the MLCCs.
- 27 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (3) , 3117-3123
Effects of External DC B -Fields on High-Frequency Impedance Characteristics of Multilayer Ceramic Capacitors
Multilayer ceramic capacitors (MLCCs) are widely used in power electronics. Because paraelectric and ferroelectric material are nonmagnetic dielectrics, B-field effects are typically ignored in datasheets and design consideration. This letter reveals a significant, previously undocumented phenomenon: B-fields cause substantial high-frequency impedance variation in MLCCs, with observed changes exceeding 43% under B-fields up to 491 mT. Supplementary material includes all the design files for the measurement kit and all the raw data to ensure reproducibility. Raman spectroscopy and microstructure were employed to characterize the material composition and physical structure of the MLCCs.
- 2 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (10) , 14277-14281
An Embedded Current Sensing Method for Nanosecond-Pulsewidth and High-Power LIV Testing
This letter presents an embedded current sensing (ECS) method to address the critical challenges in light–current–voltage (LIV) testing under nanosecond-pulsewidth and high-peak-power conditions. The conventional LIV testing method is mainly limited by the accuracy of current measurement at high di/dt. The proposed ECS method leverages an innerlayer printed circuit board (PCB) trace coupled with the parasitic inductances of the power loop, and combines with correction mechanisms to convert transient current variations into measurable induced voltages. Experimental validation demonstrates the method’s capability to reconstruct current waveforms with peak currents approaching 70 A and pulsewidths as narrow as 5.8 ns, surpassing traditional shunt resistor method. Furthermore, the developed LIV test platform establishes a foundational framework for reliable characterization of high-power laser devices. This work bridges the validation and testing gap for next-generation optoelectronic devices operating in high-speed, high-current regimes.
- 2 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (10) , 14277-14281
An Embedded Current Sensing Method for Nanosecond-Pulsewidth and High-Power LIV Testing
This letter presents an embedded current sensing (ECS) method to address the critical challenges in light–current–voltage (LIV) testing under nanosecond-pulsewidth and high-peak-power conditions. The conventional LIV testing method is mainly limited by the accuracy of current measurement at high di/dt. The proposed ECS method leverages an innerlayer printed circuit board (PCB) trace coupled with the parasitic inductances of the power loop, and combines with correction mechanisms to convert transient current variations into measurable induced voltages. Experimental validation demonstrates the method’s capability to reconstruct current waveforms with peak currents approaching 70 A and pulsewidths as narrow as 5.8 ns, surpassing traditional shunt resistor method. Furthermore, the developed LIV test platform establishes a foundational framework for reliable characterization of high-power laser devices. This work bridges the validation and testing gap for next-generation optoelectronic devices operating in high-speed, high-current regimes.
- 16 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 12003-12010
Reducing Near-Field Magnetic Radiation and Parasitic Inductance in SiC Half-Bridge Modules via Optimized Shielding Design
Near-field radiation and parasitic inductance are key challenges for silicon carbide (SiC) mosfets. Current packaging techniques aiming at reducing inductance primarily focus on minimizing the commutation loop area, but these methods require complex layouts, routings, and manufacturing processes. Based on the physical principle that inductance is determined by the integral of the magnetic energy density, this manuscript proposes using copper shielding to induce eddy currents, thereby reducing the near-field magnetic radiation energy. The energy reduction further decreases parasitic inductance. Simulations and experiments indicate that for TO-247, the method can reduce inductance by 56.69% (from 23.39 to 10.13 nH) and radiation by 94.75% (from 13.16 to 0.69 μT). Furthermore, using single-layer direct-bonded copper the proposed method can reduce inductance by 81.85% (from 2.81 to 0.51 nH) and radiation by 76.12% (from 13.16 to 0.69 μT). The multimedia folder has included all the critical data, including the package designs, printed circuit board (PCB) designs, simulation files, and experimental raw data.
- 16 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 12003-12010
Reducing Near-Field Magnetic Radiation and Parasitic Inductance in SiC Half-Bridge Modules via Optimized Shielding Design
Near-field radiation and parasitic inductance are key challenges for silicon carbide (SiC) mosfets. Current packaging techniques aiming at reducing inductance primarily focus on minimizing the commutation loop area, but these methods require complex layouts, routings, and manufacturing processes. Based on the physical principle that inductance is determined by the integral of the magnetic energy density, this manuscript proposes using copper shielding to induce eddy currents, thereby reducing the near-field magnetic radiation energy. The energy reduction further decreases parasitic inductance. Simulations and experiments indicate that for TO-247, the method can reduce inductance by 56.69% (from 23.39 to 10.13 nH) and radiation by 94.75% (from 13.16 to 0.69 μT). Furthermore, using single-layer direct-bonded copper the proposed method can reduce inductance by 81.85% (from 2.81 to 0.51 nH) and radiation by 76.12% (from 13.16 to 0.69 μT). The multimedia folder has included all the critical data, including the package designs, printed circuit board (PCB) designs, simulation files, and experimental raw data.
- Open Access
- 11 October 2024
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 111 (1) , 1614-1618
In-vivo tissue healing mechanism at the intestinal anastomosis site following high-frequency electric welding
To investigate the effect of High-Frequency Electric Welding (HFEW) on intestinal tissue healing, we performed end-to-end anastomosis experiments in New Zealand rabbits. Within one week post-surgery, animals exhibited normal vital signs, replaced necrotic tissue with healthy collagen, and showed improved tissue strength while inflammation decreased. By day 60, tissue pathology and function fully recovered, resembling normal tissue. Healing at the anastomotic site occurred in three phases: immediate adhesion, inflammation, and remodeling, with macrophages crucial for phagocytosis and regeneration of necrotic tissue. This study enhances understanding of HFEW’s healing mechanisms and supports further preclinical investigations. Export
- 11 October 2024
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 111 (1) , 1614-1618
Open AccessIn-vivo tissue healing mechanism at the intestinal anastomosis site following high-frequency electric welding
To investigate the effect of High-Frequency Electric Welding (HFEW) on intestinal tissue healing, we performed end-to-end anastomosis experiments in New Zealand rabbits. Within one week post-surgery, animals exhibited normal vital signs, replaced necrotic tissue with healthy collagen, and showed improved tissue strength while inflammation decreased. By day 60, tissue pathology and function fully recovered, resembling normal tissue. Healing at the anastomotic site occurred in three phases: immediate adhesion, inflammation, and remodeling, with macrophages crucial for phagocytosis and regeneration of necrotic tissue. This study enhances understanding of HFEW’s healing mechanisms and supports further preclinical investigations. Export