Trine Juul-Kristensen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Trine Juul-Kristensen has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Birgitta Ruth Knudsen
Aarhus University
2 shared publications - Josephine Geertsen Keller
Aarhus University
2 shared publications - Amalie Foldager
Department of Molecular Biology and Genetics, Aarhus University, 8000 Aarhus, Denmark
1 shared publication - Celine Thiesen
Department of Molecular Biology and Genetics, Universitetsbyen 81, Aarhus University, 8000 Aarhus, Denmark
1 shared publication - Cinzia Tesauro
Aarhus University
1 shared publication - Eduardo Pareja
Oh no sequences! Research group, Era7 Bioinformatics, Granada, Spain
1 shared publication
Latest Publications
- Open Access
Non-Invasive Malaria Detection in Sub-Saharan Africa Using a DNA-Based Sensor System
Malaria poses a serious global health problem, with half the world population being at risk. Regular screening is crucial for breaking the transmission cycle and combatting the disease spreading. However, current diagnostic tools relying on blood samples face challenges in many malaria-epidemic areas. In the present study, we demonstrate the detection of the malaria-causing Plasmodium parasite in non-invasive saliva samples (N = 61) from infected individuals by combining a DNA-based Rolling-circle-Enhanced-Enzyme-Activity-Detection (REEAD) sensor system with a chemiluminescence readout that could be detected with an in-house-developed affordable and battery-powered portable reader. We successfully transferred the technology to sub-Saharan Africa, where the malaria burden is high, and demonstrated a proof of concept in a small study (N = 40) showing significant differences (p < 0.00001) between malaria-positive individuals (N = 33) and presumed asymptomatic negative individuals (N = 7) all collected in Gabon. This is the first successful application of the REEAD sensor system for the detection of malaria in saliva in a high-epidemic area and holds promise for the potential future use of REEAD for malaria diagnosis or surveillance based on non-invasive specimens in sub-Saharan Africa.
Open AccessNon-Invasive Malaria Detection in Sub-Saharan Africa Using a DNA-Based Sensor System
Malaria poses a serious global health problem, with half the world population being at risk. Regular screening is crucial for breaking the transmission cycle and combatting the disease spreading. However, current diagnostic tools relying on blood samples face challenges in many malaria-epidemic areas. In the present study, we demonstrate the detection of the malaria-causing Plasmodium parasite in non-invasive saliva samples (N = 61) from infected individuals by combining a DNA-based Rolling-circle-Enhanced-Enzyme-Activity-Detection (REEAD) sensor system with a chemiluminescence readout that could be detected with an in-house-developed affordable and battery-powered portable reader. We successfully transferred the technology to sub-Saharan Africa, where the malaria burden is high, and demonstrated a proof of concept in a small study (N = 40) showing significant differences (p < 0.00001) between malaria-positive individuals (N = 33) and presumed asymptomatic negative individuals (N = 7) all collected in Gabon. This is the first successful application of the REEAD sensor system for the detection of malaria in saliva in a high-epidemic area and holds promise for the potential future use of REEAD for malaria diagnosis or surveillance based on non-invasive specimens in sub-Saharan Africa.
- Open Access
- 24 October 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (11) , 950
Topoisomerase 1 Activity Is Reduced in Response to Thermal Stress in Fruit Flies and in Human HeLa Cells
In the modern world with climate changes and increasing pollution, different types of stress are becoming an increasing challenge. Hence, the identification of reliable biomarkers of stress and accessible sensors to measure such biomarkers are attracting increasing attention. In the current study, we demonstrate that the activity, but not the expression, of the ubiquitous enzyme topoisomerase 1 (TOP1), as measured in crude cell extracts by the REEAD sensor system, is markedly reduced in response to thermal stress in both fruit flies (Drosophila melanogaster) and cultivated human cells. This effect was observed in response to both mild-to-moderate long-term heat stress and more severe short-term heat stress in D. melanogaster. In cultivated HeLa cells a reduced TOP1 activity was observed in response to both cold and heat stress. The reduced TOP1 activity appeared dependent on one or more cellular pathways since the activity of purified TOP1 was unaffected by the utilized stress temperatures. We demonstrate successful quantitative measurement of TOP1 activity using an easily accessible chemiluminescence readout for REEAD pointing towards a sensor system suitable for point-of-care assessment of stress responses based on TOP1 as a biomarker.
- 24 October 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (11) , 950
Open AccessTopoisomerase 1 Activity Is Reduced in Response to Thermal Stress in Fruit Flies and in Human HeLa Cells
In the modern world with climate changes and increasing pollution, different types of stress are becoming an increasing challenge. Hence, the identification of reliable biomarkers of stress and accessible sensors to measure such biomarkers are attracting increasing attention. In the current study, we demonstrate that the activity, but not the expression, of the ubiquitous enzyme topoisomerase 1 (TOP1), as measured in crude cell extracts by the REEAD sensor system, is markedly reduced in response to thermal stress in both fruit flies (Drosophila melanogaster) and cultivated human cells. This effect was observed in response to both mild-to-moderate long-term heat stress and more severe short-term heat stress in D. melanogaster. In cultivated HeLa cells a reduced TOP1 activity was observed in response to both cold and heat stress. The reduced TOP1 activity appeared dependent on one or more cellular pathways since the activity of purified TOP1 was unaffected by the utilized stress temperatures. We demonstrate successful quantitative measurement of TOP1 activity using an easily accessible chemiluminescence readout for REEAD pointing towards a sensor system suitable for point-of-care assessment of stress responses based on TOP1 as a biomarker.