Zicheng Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zicheng Li has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Sai Zhang
School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, China
5 shared publications - Anwen Shen
National Key Laboratory of Science and Technology on Multispectral Information Processing and Key Laboratory of Image Processing and Intelligent Control, School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, China
2 shared publications Lingyan Wang
2 shared publications- Long Chen
Wuhan Institute of Technology
2 shared publications - Xiuwei Fan
School of Electrical and Information Engineering, Wuhan Institute of Technology, Wuhan, People’s Republic of China
2 shared publications - Zhi-Hong Guan
Huazhong University of Science and Technology
2 shared publications
Latest Publications
- Open Access
- 3 September 2026
- Published by Elsevier in SSRN Electronic Journal
Two-Time-Scale Off-Policy Integral Reinforcement Learning for Model-Free Distributed Robust Optimal Control Under Hybrid Cyber Attacks
This paper proposes a two-time-scale off-policy integral reinforcement learning (IRL) framework for model-free distributed robust optimal control of heterogeneous multi-agent systems under simultaneous false data injection (FDI) and denial-of-service (DoS) attacks. The core contribution lies in a singular-perturbation-based actor-critic architecture that decouples the fast critic from the slow actor, resolving the inherent circular dependency in standard actor-critic methods. Rigorous Lyapunov analysis establishes exponential convergence of both networks with explicit convergence rates and residual bounds, and proves global uniform ultimate boundedness of the closed-loop system under admissible DoS attacks. The framework further incorporates state projection matrices for heterogeneous agent coordination, a matched-filter FDI detector with robust Bellman residual correction, and a critic freezing mechanism with adaptive discount factor for DoS resilience. Simulations on three heterogeneous nonlinear pursuers validate the theoretical results.
- 3 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessTwo-Time-Scale Off-Policy Integral Reinforcement Learning for Model-Free Distributed Robust Optimal Control Under Hybrid Cyber Attacks
This paper proposes a two-time-scale off-policy integral reinforcement learning (IRL) framework for model-free distributed robust optimal control of heterogeneous multi-agent systems under simultaneous false data injection (FDI) and denial-of-service (DoS) attacks. The core contribution lies in a singular-perturbation-based actor-critic architecture that decouples the fast critic from the slow actor, resolving the inherent circular dependency in standard actor-critic methods. Rigorous Lyapunov analysis establishes exponential convergence of both networks with explicit convergence rates and residual bounds, and proves global uniform ultimate boundedness of the closed-loop system under admissible DoS attacks. The framework further incorporates state projection matrices for heterogeneous agent coordination, a matched-filter FDI detector with robust Bellman residual correction, and a critic freezing mechanism with adaptive discount factor for DoS resilience. Simulations on three heterogeneous nonlinear pursuers validate the theoretical results.
- 1 September 2026
- Published by Elsevier in Control Engineering Practice
- Vol. 177
RBFSMC neural network control based on bouc-wen model for piezoelectric actuators
- 1 September 2026
- Published by Elsevier in Control Engineering Practice
- Vol. 177
RBFSMC neural network control based on bouc-wen model for piezoelectric actuators
- Open Access
- 29 November 2025
- Published by MDPI AG in Electronics
- Vol. 14 (23) , 4708
Topology Optimization and Leakage Current Suppression of Photovoltaic Energy Storage Four-Leg Inverter Based on Independent Split Capacitor
Leakage current is a prevalent issue in non-isolated photovoltaic (PV) energy storage inverter systems, which not only induces additional power losses but also poses potential safety hazards and degrades system operational efficiency. To address this critical problem, this paper proposes an improved three-phase four-leg PV energy storage inverter topology integrated with independent split capacitors, based on the traditional three-level topology. First, an in-depth analysis of the leakage current generation mechanism is conducted, focusing on the impacts of common-mode voltage fluctuations and parasitic capacitance on leakage current paths. By establishing an equivalent mathematical model, a systematic comparative analysis is performed between the proposed topology and the traditional topology regarding key performance indicators, including leakage current suppression capability, DC-side neutral point potential stability, and power quality. Notably, the improved topology requires no additional control strategy design; under the same carrier modulation strategy and parameter configuration as the traditional topology, it can stably constrain the DC-side neutral point potential to fluctuate within an acceptable range. Experimental results demonstrate that the proposed topology reduces the peak leakage current to within 200 mA while maintaining the total harmonic distortion (THD) of the load-side current at a low level. These performance metrics comply with the relevant national and industry power quality standards for PV grid-connected systems, endowing the topology with high engineering practical value.
- 29 November 2025
- Published by MDPI AG in Electronics
- Vol. 14 (23) , 4708
Open AccessTopology Optimization and Leakage Current Suppression of Photovoltaic Energy Storage Four-Leg Inverter Based on Independent Split Capacitor
Leakage current is a prevalent issue in non-isolated photovoltaic (PV) energy storage inverter systems, which not only induces additional power losses but also poses potential safety hazards and degrades system operational efficiency. To address this critical problem, this paper proposes an improved three-phase four-leg PV energy storage inverter topology integrated with independent split capacitors, based on the traditional three-level topology. First, an in-depth analysis of the leakage current generation mechanism is conducted, focusing on the impacts of common-mode voltage fluctuations and parasitic capacitance on leakage current paths. By establishing an equivalent mathematical model, a systematic comparative analysis is performed between the proposed topology and the traditional topology regarding key performance indicators, including leakage current suppression capability, DC-side neutral point potential stability, and power quality. Notably, the improved topology requires no additional control strategy design; under the same carrier modulation strategy and parameter configuration as the traditional topology, it can stably constrain the DC-side neutral point potential to fluctuate within an acceptable range. Experimental results demonstrate that the proposed topology reduces the peak leakage current to within 200 mA while maintaining the total harmonic distortion (THD) of the load-side current at a low level. These performance metrics comply with the relevant national and industry power quality standards for PV grid-connected systems, endowing the topology with high engineering practical value.
- 16 October 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (10) , 106207
A novel open-circuit fault diagnosis method for BLDCM inverters based on current-related characteristics
Inverter switch failure is a critical issue in brushless DC motor (BLDCM) systems, significantly reducing production efficiency and increasing maintenance costs. This paper proposes a multi-switch fault diagnosis method for six-step commutation-controlled BLDCM inverters, leveraging periodic current-related characteristics within a sliding window. First, the types of open-circuit (OC) faults in multiple inverter switches are investigated and their mechanisms are analyzed. Second, four basic feature variables are extracted from the three-phase current signals within the sliding window, which can be used to determine the position of the fault switch through simple threshold judgment and mathematical operations. Finally, simulation and experimental results verify that the proposed diagnostic method is reliable, effective, and robust. Moreover, this method can detect 21 types of OC switch faults without additional sensors and can be embedded in microcontrollers for practical engineering applications.
- 16 October 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (10) , 106207
A novel open-circuit fault diagnosis method for BLDCM inverters based on current-related characteristics
Inverter switch failure is a critical issue in brushless DC motor (BLDCM) systems, significantly reducing production efficiency and increasing maintenance costs. This paper proposes a multi-switch fault diagnosis method for six-step commutation-controlled BLDCM inverters, leveraging periodic current-related characteristics within a sliding window. First, the types of open-circuit (OC) faults in multiple inverter switches are investigated and their mechanisms are analyzed. Second, four basic feature variables are extracted from the three-phase current signals within the sliding window, which can be used to determine the position of the fault switch through simple threshold judgment and mathematical operations. Finally, simulation and experimental results verify that the proposed diagnostic method is reliable, effective, and robust. Moreover, this method can detect 21 types of OC switch faults without additional sensors and can be embedded in microcontrollers for practical engineering applications.
- 29 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 72 (4) , 1574-1586
Memristor-Based Neural Network Circuit of Full-Function Pavlov Associative Memory With Unconditioned Response Mechanisms
Most memristor-based Pavlovian associative memory neural networks explore the impact of relearning and forgetting on associative memory rates. In this paper, a memristor-based neural network circuit with unconditioned response mechanisms is proposed. The circuit is composed of neuron modules, synapse modules, forgetting voltage control modules, and effective time judgment modules. The proposed circuit achieves control of the forgetting rate, which can be adjusted based on the interval of the unconditioned stimuli. Additionally, the concept of effective time judgment has been introduced. If the stimulus interval exceeds the range of effective time, the circuit will automatically proceed with natural forgetting. Furthermore, the synaptic weight between the food neuron and the salivation neuron is no longer fixed but can change based on the method of food presentation. When only looking at the food but not eating it, the connection between the visual neuron and the salivation neuron decreases, resulting in reduced salivation when seeing the food. However, after eating the food, the connection between the visual neuron and the salivation neuron quickly strengthens. This circuit further refines the functionality of neural network circuits based on the mechanisms of unconditional reflexes. Finally, these functions are validated using PSPICE.
- 29 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 72 (4) , 1574-1586
Memristor-Based Neural Network Circuit of Full-Function Pavlov Associative Memory With Unconditioned Response Mechanisms
Most memristor-based Pavlovian associative memory neural networks explore the impact of relearning and forgetting on associative memory rates. In this paper, a memristor-based neural network circuit with unconditioned response mechanisms is proposed. The circuit is composed of neuron modules, synapse modules, forgetting voltage control modules, and effective time judgment modules. The proposed circuit achieves control of the forgetting rate, which can be adjusted based on the interval of the unconditioned stimuli. Additionally, the concept of effective time judgment has been introduced. If the stimulus interval exceeds the range of effective time, the circuit will automatically proceed with natural forgetting. Furthermore, the synaptic weight between the food neuron and the salivation neuron is no longer fixed but can change based on the method of food presentation. When only looking at the food but not eating it, the connection between the visual neuron and the salivation neuron decreases, resulting in reduced salivation when seeing the food. However, after eating the food, the connection between the visual neuron and the salivation neuron quickly strengthens. This circuit further refines the functionality of neural network circuits based on the mechanisms of unconditional reflexes. Finally, these functions are validated using PSPICE.
- 4 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (20) , 33336-33346
Detection of Oil-Water Separation Process Based on Embedded Serpentine Microstrip Line Array
Dynamic monitoring of oil-water separation occupies an important position in the petroleum industry. This study introduces a sensor detection system based on a serpentine microstrip line array (SMLA) to analyze the oil-water ratio in different mixing states by measuring the phase shift of microwave signals passing through the oil-water mixture. First, the approximate structure of SMLA was derived using formulas. The high frequency structural simulator (HFSS) was utilized to optimize the structure of the SMLA and identify the optimal operating frequency. Subsequently, a detection system for oil-water separation was developed, and the experimental platform was built. Through calibration experiments, the phase shift characteristics of different oil-water ratios in two mixing states were extracted. Then, an oil-water separation experiment was conducted and combined with the phase shift calibration characteristic value. A classification decoupling method was proposed for the phase shift data collected in the mixed state and layered state, which improved the detection accuracy. Finally, the relative error of the oil-water ratio measurement in the mixed state was within 2.58%, and the relative error of the oil-water ratio measurement in the layered state was less than 0.24%. The reliability of the measuring system under different temperature conditions is also verified by experiments. The experimental results confirm that this method can provide a new solution for industrial oil-water separation detection.
- 4 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (20) , 33336-33346
Detection of Oil-Water Separation Process Based on Embedded Serpentine Microstrip Line Array
Dynamic monitoring of oil-water separation occupies an important position in the petroleum industry. This study introduces a sensor detection system based on a serpentine microstrip line array (SMLA) to analyze the oil-water ratio in different mixing states by measuring the phase shift of microwave signals passing through the oil-water mixture. First, the approximate structure of SMLA was derived using formulas. The high frequency structural simulator (HFSS) was utilized to optimize the structure of the SMLA and identify the optimal operating frequency. Subsequently, a detection system for oil-water separation was developed, and the experimental platform was built. Through calibration experiments, the phase shift characteristics of different oil-water ratios in two mixing states were extracted. Then, an oil-water separation experiment was conducted and combined with the phase shift calibration characteristic value. A classification decoupling method was proposed for the phase shift data collected in the mixed state and layered state, which improved the detection accuracy. Finally, the relative error of the oil-water ratio measurement in the mixed state was within 2.58%, and the relative error of the oil-water ratio measurement in the layered state was less than 0.24%. The reliability of the measuring system under different temperature conditions is also verified by experiments. The experimental results confirm that this method can provide a new solution for industrial oil-water separation detection.
- 27 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (12) , 14193-14203
Finite Control Set Model Predictive Control With Current Disturbance Suppression for Permanent Magnet Synchronous Motor
Finite control set model predictive control (FCSMPC) has attracted much attention because of its simple structure and easy implementation, but the current disturbance caused by the discontinuity of the switching state associated with the minimum state of the cost function in permanent magnet synchronous motor is always an unavoidable problem for FCSMPC. This article will start with the error between the feedback current and the reference current, and optimize the error between them in the cost function, so as to realize the reduction of output current disturbance due to the discontinuous switching state. Subsequently, the sliding mode schemes are introduced to selectively reduce the error between them, thereby, indirectly enhancing the current robustness of FCSMPC. Meanwhile, a detailed quantitative analysis of the error between them is presented using sliding mode schemes. The discussion then, focuses on the suppression capability of different sliding mode schemes. Finally, different experiments are designed to verify the feasibility of the controller and the correctness of the theory.
- 27 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (12) , 14193-14203
Finite Control Set Model Predictive Control With Current Disturbance Suppression for Permanent Magnet Synchronous Motor
Finite control set model predictive control (FCSMPC) has attracted much attention because of its simple structure and easy implementation, but the current disturbance caused by the discontinuity of the switching state associated with the minimum state of the cost function in permanent magnet synchronous motor is always an unavoidable problem for FCSMPC. This article will start with the error between the feedback current and the reference current, and optimize the error between them in the cost function, so as to realize the reduction of output current disturbance due to the discontinuous switching state. Subsequently, the sliding mode schemes are introduced to selectively reduce the error between them, thereby, indirectly enhancing the current robustness of FCSMPC. Meanwhile, a detailed quantitative analysis of the error between them is presented using sliding mode schemes. The discussion then, focuses on the suppression capability of different sliding mode schemes. Finally, different experiments are designed to verify the feasibility of the controller and the correctness of the theory.
- Open Access
- 21 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 5, 381-391
Torque Ripple Suppression of BLDCM With Optimal Duty Cycle and Switch State by FCS-MPC
The traditional six-step commutation control method in brushless DC motors (BLDCM) often results in significant torque ripple, which limits its application in high-precision fields. This paper proposes a scheme that combines finite control set model predictive control (FCS-MPC) to suppress commutation torque ripple. The scheme utilizes an optimal duty cycle and optimal switch compensation state. By analyzing the mathematical model of BLDC motors, the causes of commutation torque ripple were identified. To maintain the slope of the non-commutation current unchanged, a discrete model was used to predict the non-commutation current at the next moment. The predicted current was then used to calculate the optimal duty cycle. To address the shortcomings of PWM regulation performance at high speeds, a switch insertion compensation strategy was proposed. The strategy selects the optimal switch insertion compensation state based on a cost function to offset the changes in non-commutation current. Furthermore, feedback compensation was incorporated to enhance robustness in the event of parameter mismatch. The effectiveness of this method was demonstrated through experimental and simulation results.
- 21 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 5, 381-391
Open AccessTorque Ripple Suppression of BLDCM With Optimal Duty Cycle and Switch State by FCS-MPC
The traditional six-step commutation control method in brushless DC motors (BLDCM) often results in significant torque ripple, which limits its application in high-precision fields. This paper proposes a scheme that combines finite control set model predictive control (FCS-MPC) to suppress commutation torque ripple. The scheme utilizes an optimal duty cycle and optimal switch compensation state. By analyzing the mathematical model of BLDC motors, the causes of commutation torque ripple were identified. To maintain the slope of the non-commutation current unchanged, a discrete model was used to predict the non-commutation current at the next moment. The predicted current was then used to calculate the optimal duty cycle. To address the shortcomings of PWM regulation performance at high speeds, a switch insertion compensation strategy was proposed. The strategy selects the optimal switch insertion compensation state based on a cost function to offset the changes in non-commutation current. Furthermore, feedback compensation was incorporated to enhance robustness in the event of parameter mismatch. The effectiveness of this method was demonstrated through experimental and simulation results.
- 4 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (4) , 2522-2533
An Adaptive Strategy for PMSM-Based Disturbance Estimation and Online Parameter Identification
Electric vehicles (EVs) mainly use permanent magnet synchronous motors (PMSMs) as the core power units. Moreover, when EVs navigate complex roads, the requirements become even more stringent. This paper addresses the real-time parameter estimation and state evaluation of PMSMs in EVs, considering the inevitable external interference. By leveraging the stability condition of the energy function, a simple adaptive scheme is proposed to enhance the robustness of PMSMs against current disturbances. At the same time, the online identification scheme for motor parameters is considered, which extends the practical application method of Lyapunov energy function stability. Subsequently, in order to optimize the current disturbance caused by parameter mismatch, the known model will be adjusted to the unknown model and the adaptive fuzzy scheme is introduced to discuss with the relevant parameters designed from the stability condition of the adaptive fuzzy Lyapunov energy function. Finally, the effectiveness of the proposed scheme in this paper is proved by various experiments.
- 4 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (4) , 2522-2533
An Adaptive Strategy for PMSM-Based Disturbance Estimation and Online Parameter Identification
Electric vehicles (EVs) mainly use permanent magnet synchronous motors (PMSMs) as the core power units. Moreover, when EVs navigate complex roads, the requirements become even more stringent. This paper addresses the real-time parameter estimation and state evaluation of PMSMs in EVs, considering the inevitable external interference. By leveraging the stability condition of the energy function, a simple adaptive scheme is proposed to enhance the robustness of PMSMs against current disturbances. At the same time, the online identification scheme for motor parameters is considered, which extends the practical application method of Lyapunov energy function stability. Subsequently, in order to optimize the current disturbance caused by parameter mismatch, the known model will be adjusted to the unknown model and the adaptive fuzzy scheme is introduced to discuss with the relevant parameters designed from the stability condition of the adaptive fuzzy Lyapunov energy function. Finally, the effectiveness of the proposed scheme in this paper is proved by various experiments.