CXChaojian Xing

Chaojian Xing

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chaojian Xing has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Shuxin Liu

    Key Lab of Special Electric Machine and High Voltage Apparatus (College of Electrical Engineering, Shenyang University of Technology), Shenyang, China

    5 shared publications
  • Yankai Li

    Shenyang University of Technology Special Motor and High-voltage Electrical Appliance Key Laboratory of the Ministry of Education, Shenyang, China

    4 shared publications
  • Shuxin Liu

    Shenyang University of Technology Special Motor and High-voltage Electrical Appliance Key Laboratory of the Ministry of Education, Shenyang, China

    3 shared publications
  • Yankai Li

    Key Laboratory of Special Electric Machines and High Voltage Apparatus in the Ministry of Education, Shenyang University of Technology, Shenyang 110870, People’s Republic of China

    3 shared publications
  • Jing Li

    Key Laboratory of Special Machines and High Voltage Apparatus, School of Electrical Engineering, Shenyang University of Technology, Shenyang, China

    2 shared publications
  • Jing Xu

    Key Laboratory of Special Machines and High Voltage Apparatus, School of Electrical Engineering, Shenyang University of Technology, Shenyang, China

    2 shared publications

Latest Publications

  • A fault diagnosis method for AC contactors based on multimodal feature fusion

    by Shuxin Liu, Zhe Li, Yankai Li, Chaojian Xing, Yufan Chai

    Accurate fault identification of AC contactors is challenging due to low signal utilization, weak feature representation, and the limited robustness of existing diagnostic methods. To address these issues, this study proposes a multimodal fault diagnosis approach that integrates enhanced time-frequency features with temporal vibration characteristics. A full-life experimental platform was established to synchronously acquire vibration, voltage, and current signals, enabling the construction of five typical fault categories based on electrical-parameter thresholds. To improve the measurability of vibration features, a multiscale short-time Fourier transform (STFT) combined with a squeeze-and-excitation block (SE Block) was used to generate noise-suppressed, contrast-enhanced time-frequency maps. A dual-branch network was then designed, consisting of a convolutional block attention module (CBAM)-optimized ResNet-18 for spatial feature extraction and a bidirectional gated recurrent unit (BiGRU) module for temporal modeling. The fused multimodal features were used for comprehensive fault classification. Experimental results show that the proposed method achieves an accuracy of 98.6%, significantly outperforming single-modality models. The results demonstrate that multimodal fusion effectively enhances fault feature discrimination and improves the robustness of AC contactor condition monitoring.

  • Research on Failure Determination of Switching Devices Coupling Indicators Based on Vibration Parameters and ESNIM

    by Yankai Li, Shuxin Liu, Chaojian Xing

    The degradation process of switching devices with contact structures is characterized by diversification and multi-attributes, which makes it difficult to determine the real state of the switching devices through a single indicator, but the existing methods neglect the definition and determination process of the coupling indicators, so this paper combines the advantages of vibration signal acquisition with low cost and convenient practical installation, proposes a method for failure determination of switching devices coupling indicators based on vibration parameters and Echo State Network Integration Model (ESNIM). Firstly, failure indicators and vibration signal datasets under different coupling states are constructed using CJX2-5011 switching devices as experimental objects. Then, 26-dimensional vibration parameters are extracted from the switching device vibration signals, and strongly correlated vibration parameters for the determination of each indicator are constructed using the Spearman correlation coefficient. Finally, the ESNIM switching device coupling indicator failure determination model is designed to achieve high-precision detection of switching device states. Compared to other methods, the ESNIM model's average evaluation metrics are higher by at least 0.006, 0.002, 0.011, and 0.006, respectively, effectively illustrating the superiority of the ESNIM model in the process of coupling indicator failure determination. It provides a new technical solution for prognostics health management (PHM) of switching devices with contact structures.

  • Degradation Stage Division and Identification of AC Contactor’s Contact System

    by Chaojian Xing, Shuxin Liu, Yankai Li, Jing Xu, Jing Li

    The stage division and state recognition during AC contactor degradation process is an important prerequisite for realizing its self-perception. In the recognition of its degradation state, the traditional method cannot effectively identify similar and overlapping degradation states, which makes it impossible to make accurate judgments when evaluating the health state of AC contactor. To solve the above problems, a method of ac contactor’s contact degradation stage division and state recognition based on Boundary Detection and Temporal Convolutional Network-Transformer-Bidirectional Gated Recurrent Unit (TCN-Transformer-BiGRU) was proposed in this paper. Firstly, the characteristic parameters related to the degradation of the ac contactor were obtained through the full life test, and the kernel principal component analysis (KPCA) was introduced to fuse the characteristic parameters. Then, the degradation trend of the contact system was characterized, and the Boundary Detection method was used to divide the ac contactor degradation stage. Finally, the TCN-Transformer-BiGRU classification prediction model was used to accurately identify the degradation state of the ac contactor. Taking other samples of the same type of AC contactor as examples, it is verified that the method has good universality and high accuracy.


  • Characterization of Contactor Degradation States Based on Improved Variational Modal Decomposition and Optimized Similarity Metrics With Combined Weights

    by Shuxin Liu, Yankai Li, Chaojian Xing, Shidong Peng, Jing Xu, Yundong Cao

    Aiming at the problem that it is difficult to extract useful information from the contactor characteristic parameter data due to a large amount of noise interference, and it is difficult to determine the weight allocation of different characteristic parameters in the process of contactor degradation state characterisation, this paper proposes a contactor degradation state characterisation method based on the improved variational modal decomposition and the optimisation of similarity metrics with combined weights. Firstly, the CJX2-5011 model contactor is taken as the experimental object, and the full-life test is carried out to extract the contactor characteristic parameter data; Then, the sparrow search algorithm (SSA) is used to optimise the parameter settings of the variational modal decomposition, and the optimal component selection and noise reduction are completed based on the correlation determination and wavelet threshold noise reduction, which effectively extracts the useful information of the feature parameters; Secondly, The combined weights of feature parameters are constructed by Analytic Hierarchy Process (AHP) and CRITIC weighting method, which solves the problem of weight allocation of feature parameters in the process of characterising the degraded state of the contactor; Finally, the combination of weights is used to optimise the similarity measurement process and achieve a more accurate characterisation of the contactor degradation state. In the multi-characteristic parameter noise reduction process, the Noise Rejection Rate ( NRR ) and Correlation (ρ) are at least improved by 0.0592 and 0.0006. In the degraded state characterisation, the Goodness of Fit ( R ) is improved by at least 0.06723, and the Root Mean Square Error ( RMSE ) is reduced by at least 0.34689. Therefore, it can be seen that the method in this paper is able to better complete the noise reduction of the contactor characteristic parameter data, and to achieve a more accurate characterisation of the degraded state of the contactor.


  • Remaining electrical life prediction of AC contactor based on CAE-BiGRU-Attention

    by Chaojian Xing, Shuxin Liu, Shidong Peng, Shuyu Gao, Yang Liu, Jing Li, Yundong Cao

    To tackle the challenges of low prediction accuracy caused by single-feature modeling, and the hidden state of the neural network easily loses some information of the long time series, a method for predicting the remaining electrical life of AC contactor using a convolutional autoencoder-bidirectional gated recurrent unit-attention (CAE-BiGRU-Attention) was proposed in this work. Firstly, the feature parameters were extracted from the AC contactor full-life test, and an optimal feature subset was selected using neighborhood component analysis and Spearman rank correlation coefficient to characterize the degradation state of electrical life effectively. Then, the deep information of the optimal feature subset was extracted using CAE. Finally, the remaining electrical life of the AC contactor was treated as a long time series problem and predicted in time series by BiGRU-Attention accurately. The case analysis demonstrates that the model has better prediction accuracy than recurrent neural network (RNN), long short-term memory (LSTM), GRU, BiGRU and CAE-BiGRU models, with an average effective accuracy of 97.12%. This effectively demonstrates the model’s feasibility to accurately predict temporal sequences in the remaining electrical life prediction of electrical equipment.