Hao Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hao Liu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Tianzhi Fang
Center for More-Electrical-Aircraft Power System, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
4 shared publications - Zhiheng Lin
University of Alberta
3 shared publications - Chengyi Liu
Center for More-Electrical-Aircraft Power System, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
2 shared publications Huili Zhang
Jiehuate Microelectronics Company, Ltd., Hangzhou, China
1 shared publicationPeng Wang
AVIC Nanjing Engineering Institute of Aircraft Systems, Nanjing, China
1 shared publicationQiyuan Jin
Huawei Digital Power Technologies Co., Ltd., Shenzhen, China
1 shared publication
Latest Publications
- 13 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 2902-2913
Virtual Capacitor Strategy to Coordinate Stability and Power Balance in Droop-Controlled Input-Parallel–Output-Series Grid-Connected Inverter System
To address the high voltage difference between the low-voltage photovoltaic (PV) array and the mid-voltage distribution grid, the input-parallel output-series (IPOS) grid-connected inverter system is employed to reduce the reliance on high-ratio step-up transformers. This article focuses on the droop control strategy for IPOS systems, where a precise mathematical model reveals the dual effects of the droop coefficient: while increasing the coefficient enhances power balancing, excessive values introduce a negative damping effect that degrades system stability. To resolve this trade-off, this article proposes a virtual capacitor-based impedance reshaping method to optimize stability margins by adjusting the positive-damping region. Theoretically, rigorous derivation establishes quantitative design criteria for both droop coefficient and virtual capacitance parameters, providing comprehensive guidance for parameter tuning. Finally, experimental results based on a two-module IPOS prototype demonstrate that the proposed strategy maintains system stability while achieving power-sharing accuracy, validating both theoretical soundness and practical feasibility.
- 13 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 2902-2913
Virtual Capacitor Strategy to Coordinate Stability and Power Balance in Droop-Controlled Input-Parallel–Output-Series Grid-Connected Inverter System
To address the high voltage difference between the low-voltage photovoltaic (PV) array and the mid-voltage distribution grid, the input-parallel output-series (IPOS) grid-connected inverter system is employed to reduce the reliance on high-ratio step-up transformers. This article focuses on the droop control strategy for IPOS systems, where a precise mathematical model reveals the dual effects of the droop coefficient: while increasing the coefficient enhances power balancing, excessive values introduce a negative damping effect that degrades system stability. To resolve this trade-off, this article proposes a virtual capacitor-based impedance reshaping method to optimize stability margins by adjusting the positive-damping region. Theoretically, rigorous derivation establishes quantitative design criteria for both droop coefficient and virtual capacitance parameters, providing comprehensive guidance for parameter tuning. Finally, experimental results based on a two-module IPOS prototype demonstrate that the proposed strategy maintains system stability while achieving power-sharing accuracy, validating both theoretical soundness and practical feasibility.
- 30 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (1) , 615-625
Robust Control Method Based on μ-Synthesis Theory and Genetic Algorithm for Grid-Connected Inverter to Cope With Multiple Uncertainties Under Weak Grid
In the renewable energy-based distributed power generation system, the grid-connected inverter is the interface between the generation unit and the grid. Thus, the stable operation of the grid-connected inverter system is crucial. However, the stability of the grid-connected inverter system is often affected by many aspects simultaneously, such as uncertain grid impedance and control delay. To improve the robustness of the system with the multiple uncertainties, μ-synthesis theory is adopted in this paper. By intelligently constructing the weighting functions, the robustness, dynamic performance and power quality of the grid-connected inverter system can be taken into account at the same time, when designing the controller. Furthermore, to avoid the designed controller being too high to be realized in practice, this paper proposes to use a 3rd order controller which is optimally designed by engaging the genetic algorithm. Finally, a prototype is fabricated and tested. The experimental results verify the theoretical analysis and merits of the controller designed by the proposed method compared to the controller designed by the traditional method.
- 30 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (1) , 615-625
Robust Control Method Based on μ-Synthesis Theory and Genetic Algorithm for Grid-Connected Inverter to Cope With Multiple Uncertainties Under Weak Grid
In the renewable energy-based distributed power generation system, the grid-connected inverter is the interface between the generation unit and the grid. Thus, the stable operation of the grid-connected inverter system is crucial. However, the stability of the grid-connected inverter system is often affected by many aspects simultaneously, such as uncertain grid impedance and control delay. To improve the robustness of the system with the multiple uncertainties, μ-synthesis theory is adopted in this paper. By intelligently constructing the weighting functions, the robustness, dynamic performance and power quality of the grid-connected inverter system can be taken into account at the same time, when designing the controller. Furthermore, to avoid the designed controller being too high to be realized in practice, this paper proposes to use a 3rd order controller which is optimally designed by engaging the genetic algorithm. Finally, a prototype is fabricated and tested. The experimental results verify the theoretical analysis and merits of the controller designed by the proposed method compared to the controller designed by the traditional method.
- 5 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (11) , 15224-15228
Droop Control Strategy Without Interconnection Lines for Input-Parallel Output-Series Grid-Connected Inverter System
The input-parallel output-series (IPOS) grid-connected inverter system is suitable for low input voltage and high output voltage occasions, such as solar energy based distributed power generation systems. This letter explores to select least number of control variables to realize multiple control objectives of IPOS grid-connected inverter system, including good system stability, high power factor, and power balance. Then, to avoid interconnection lines among modules to obtain better disturbance-rejection performance, a droop control strategy without interconnection lines is derived based on the duality of input-parallel output-parallel system. Even if the modules hardware parameters are unmatched, the power balance among the modules can also be ensured by increasing the droop coefficient. Finally, the experimental results based on a two-module IPOS grid-connected inverter prototype and simulation results based on three-modulate system are provided to verify the effectiveness of the proposed method.
- 5 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (11) , 15224-15228
Droop Control Strategy Without Interconnection Lines for Input-Parallel Output-Series Grid-Connected Inverter System
The input-parallel output-series (IPOS) grid-connected inverter system is suitable for low input voltage and high output voltage occasions, such as solar energy based distributed power generation systems. This letter explores to select least number of control variables to realize multiple control objectives of IPOS grid-connected inverter system, including good system stability, high power factor, and power balance. Then, to avoid interconnection lines among modules to obtain better disturbance-rejection performance, a droop control strategy without interconnection lines is derived based on the duality of input-parallel output-parallel system. Even if the modules hardware parameters are unmatched, the power balance among the modules can also be ensured by increasing the droop coefficient. Finally, the experimental results based on a two-module IPOS grid-connected inverter prototype and simulation results based on three-modulate system are provided to verify the effectiveness of the proposed method.
- 8 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (7) , 7199-7209
Robust Technique Using the Optimized Grid Voltage Feedforward to Conquer the Impact Induced by Dual Factors for Grid-Connected Inverter in Weak Grid
For grid-connected inverter, phase-locked loop (PLL) is generally adopted to obtain the voltage phase information in order to make the grid current synchronized with the grid voltage. In the meantime, the grid voltage feedforward (GVF) is usually employed to improve the grid current quality. While, both of them may deteriorate the system stability in weak grid. This article focuses on the single-phase LCL -type grid-connected inverter, and aims to put forward the optimizing scheme of dealing with the instability caused by these dual factors. In view of this, the weighted GVF is adopted to make a tradeoff between the system stability and harmonics rejection ability. Because the GVF in weak grid will introduce a grid current branch, the bandwidth of the current loop will be improved, which is conducive to reducing the coupling effect of PLL and the current loop. Therefore, the weighted coefficient will also affect the PLL issue. Considering the limited effect of the weighted coefficient on enhancing the system stability, a voltage feedforward path is further added to improve the output admittance phase. The results show that the inverter with the improved feedforward path can maintain good robustness against the wide grid impedance variation.
- 8 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (7) , 7199-7209
Robust Technique Using the Optimized Grid Voltage Feedforward to Conquer the Impact Induced by Dual Factors for Grid-Connected Inverter in Weak Grid
For grid-connected inverter, phase-locked loop (PLL) is generally adopted to obtain the voltage phase information in order to make the grid current synchronized with the grid voltage. In the meantime, the grid voltage feedforward (GVF) is usually employed to improve the grid current quality. While, both of them may deteriorate the system stability in weak grid. This article focuses on the single-phase LCL -type grid-connected inverter, and aims to put forward the optimizing scheme of dealing with the instability caused by these dual factors. In view of this, the weighted GVF is adopted to make a tradeoff between the system stability and harmonics rejection ability. Because the GVF in weak grid will introduce a grid current branch, the bandwidth of the current loop will be improved, which is conducive to reducing the coupling effect of PLL and the current loop. Therefore, the weighted coefficient will also affect the PLL issue. Considering the limited effect of the weighted coefficient on enhancing the system stability, a voltage feedforward path is further added to improve the output admittance phase. The results show that the inverter with the improved feedforward path can maintain good robustness against the wide grid impedance variation.