Latest Publications
- Open Access
- 30 October 2026
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 58
Methodology for evaluating multifactor energy efficiency indicators of a heat-generating window based on regression analysis
This study establishes a methodological approach for evaluating the energy efficiency indicators of a translucent building envelope component—featuring an integrated air-to-air heat pump and photovoltaic coating—while accounting for changing climatic parameters. This structural element combines the primary function of a translucent envelope (providing natural interior lighting) with the additional functions of heat generation and electricity production. Its integration with heating and air conditioning systems can enhance the energy efficiency of various types of premises and buildings as a whole. Achieving specified indoor microclimate parameters requires a rational combination of the heat-generating window's structural and functional features with heating and air conditioning technologies.The proposed methodology for evaluating the multi-factor energy efficiency indicators of the heat-generating window is based on a regression analysis of the interactions between controllable, monitored, and uncontrollable experimental factors. Accounting for their mutual influence improves the reliability of the assessment, reduces the volume of experimental measurements of thermophysical quantities required, and enables the determination of optimal structural and functional parameters for the design under study. The heat-generating window is considered as a multifactor system. A linear-in-parameters regression structure containing the main effects and pairwise interactions of the five factors is proposed. The factors are represented in coded form to provide a dimensionless coordinate system and to enable comparison of the regression coefficients. The proposed procedure includes experimental identification of the regression coefficients, assessment of their statistical significance, residual and lack-of-fit analysis, and verification of model adequacy.After experimental identification and validation, the resulting regression models can be used to predict the energy, thermal and exergy characteristics of the heat-generating window within the investigated factor space.
- 30 October 2026
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 58
Open AccessMethodology for evaluating multifactor energy efficiency indicators of a heat-generating window based on regression analysis
This study establishes a methodological approach for evaluating the energy efficiency indicators of a translucent building envelope component—featuring an integrated air-to-air heat pump and photovoltaic coating—while accounting for changing climatic parameters. This structural element combines the primary function of a translucent envelope (providing natural interior lighting) with the additional functions of heat generation and electricity production. Its integration with heating and air conditioning systems can enhance the energy efficiency of various types of premises and buildings as a whole. Achieving specified indoor microclimate parameters requires a rational combination of the heat-generating window's structural and functional features with heating and air conditioning technologies.The proposed methodology for evaluating the multi-factor energy efficiency indicators of the heat-generating window is based on a regression analysis of the interactions between controllable, monitored, and uncontrollable experimental factors. Accounting for their mutual influence improves the reliability of the assessment, reduces the volume of experimental measurements of thermophysical quantities required, and enables the determination of optimal structural and functional parameters for the design under study. The heat-generating window is considered as a multifactor system. A linear-in-parameters regression structure containing the main effects and pairwise interactions of the five factors is proposed. The factors are represented in coded form to provide a dimensionless coordinate system and to enable comparison of the regression coefficients. The proposed procedure includes experimental identification of the regression coefficients, assessment of their statistical significance, residual and lack-of-fit analysis, and verification of model adequacy.After experimental identification and validation, the resulting regression models can be used to predict the energy, thermal and exergy characteristics of the heat-generating window within the investigated factor space.
- 28 August 2026
- Published by Springer Nature
- p. 327-339
Experimental Study of the Impact of Airflow Imbalance on the Efficiency of a Decentralised Air Recuperator
- 28 August 2026
- Published by Springer Nature
- p. 327-339
Experimental Study of the Impact of Airflow Imbalance on the Efficiency of a Decentralised Air Recuperator
- Open Access
- 25 December 2025
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 54
Analysis of energy efficiency indicators of a heat-generating window
The growth of technological progress leads to continuous improvement not only of enclosing structures, but also of engineering life support systems. Any building in the cold season constantly loses internal thermal energy from the heating system due to the transfer of heat from the warmer internal environment of the premises to the colder outside air. Heat losses through enclosing structures and the negative contribution of each of its elements are specific to each building. However, in the vast majority of cases, the greatest heat losses occur in translucent enclosing structures (windows). Such elements are the objects of scientific research in greater numbers. The global increase in the cost of energy carriers and the need to reduce greenhouse gas emissions stimulate the development of systems that combine functionality and environmental friendliness. The “heat-generating window” offers a promising approach to ensuring the energy efficiency of buildings that meets the needs of modern society. The introduction of this type of structure can help optimize the distribution of heat flows and reduce overall heat losses by external building enclosures. Analysis and deep understanding of heat balances in such a system is the basis for its effective implementation and expansion of the scope of application. This design, combining the main functions of a translucent enclosing structure (as the most vulnerable, in terms of heat loss, element of the enclosure) with elements of heating and air conditioning systems, can significantly increase the energy efficiency of windows, but, at the same time, requires a new approach to determining the level of energy efficiency of such a system. The purpose of this work is to obtain and analyze key indicators of energy efficiency of a heat-generating window based on traditional thermophysical parameters. The following criteria are proposed for use: the light transmittance of the window structure, taking into account the coating of the glass with a film photovoltaic surface; assessment of the efficiency of heat flow distribution in the system; the efficiency of the translucent photovoltaic surface; the coefficient of conversion of electrical energy into generated thermal power (COP).
- 25 December 2025
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 54
Open AccessAnalysis of energy efficiency indicators of a heat-generating window
The growth of technological progress leads to continuous improvement not only of enclosing structures, but also of engineering life support systems. Any building in the cold season constantly loses internal thermal energy from the heating system due to the transfer of heat from the warmer internal environment of the premises to the colder outside air. Heat losses through enclosing structures and the negative contribution of each of its elements are specific to each building. However, in the vast majority of cases, the greatest heat losses occur in translucent enclosing structures (windows). Such elements are the objects of scientific research in greater numbers. The global increase in the cost of energy carriers and the need to reduce greenhouse gas emissions stimulate the development of systems that combine functionality and environmental friendliness. The “heat-generating window” offers a promising approach to ensuring the energy efficiency of buildings that meets the needs of modern society. The introduction of this type of structure can help optimize the distribution of heat flows and reduce overall heat losses by external building enclosures. Analysis and deep understanding of heat balances in such a system is the basis for its effective implementation and expansion of the scope of application. This design, combining the main functions of a translucent enclosing structure (as the most vulnerable, in terms of heat loss, element of the enclosure) with elements of heating and air conditioning systems, can significantly increase the energy efficiency of windows, but, at the same time, requires a new approach to determining the level of energy efficiency of such a system. The purpose of this work is to obtain and analyze key indicators of energy efficiency of a heat-generating window based on traditional thermophysical parameters. The following criteria are proposed for use: the light transmittance of the window structure, taking into account the coating of the glass with a film photovoltaic surface; assessment of the efficiency of heat flow distribution in the system; the efficiency of the translucent photovoltaic surface; the coefficient of conversion of electrical energy into generated thermal power (COP).
- Open Access
- 3 July 2025
- Published by The Gas Institute of the National Academy of Sciences of Ukraine in Energy Technologies & Resource Saving
- Vol. 83 (2) , 132-144
FORECASTING THE PARAMETERS OF AN AIR PURIFIER WITH AN INTEGRATED HEAT EXCHANGER AS AN ELEMENT OF ENERGY SAVING MEASURES
Air purifier model with built-in air-to-air heat exchanger was investigated. A complete factor experiment, orthogonal and rotatable planning for two- and three-level ratio of factors was carried out. A statistical analysis of the experiment was carried out. Found the most accurate mathematical model that allows you to predict the values of the parameters of the state of the object Y and optimize its parameters in further studies depending on the factors Xi. Based on the obtained data, the design of the filter-heat exchanger with the heat exchange part built into the air cleaner is modeled. Conducted experimental studies in the filter-heat exchanger. The description of the experimental stand and methods of experimental research are given. The cleaning capacity of the filter-heat exchanger for the removal of various levels of PM2.5 pollution with the change of some parameters of the internal air environment (relative humidity, air exchange rate) per unit time is determined. Experimentally determined value of air cleaner Clean Air Delivery Rate for the predicted cleaning duration is not more than 1 hour. The regression equations for various cleaning parameters are determined by which the cleaning time will be determined with known input data (pollution levels, relative humidity, air cleaning performance). Forecasting can be used in smart home systems, in enterprises and in ventilation and air conditioning systems. Bibl. 21, Fig. 7, Tab. 2.
- 3 July 2025
- Published by The Gas Institute of the National Academy of Sciences of Ukraine in Energy Technologies & Resource Saving
- Vol. 83 (2) , 132-144
Open AccessFORECASTING THE PARAMETERS OF AN AIR PURIFIER WITH AN INTEGRATED HEAT EXCHANGER AS AN ELEMENT OF ENERGY SAVING MEASURES
Air purifier model with built-in air-to-air heat exchanger was investigated. A complete factor experiment, orthogonal and rotatable planning for two- and three-level ratio of factors was carried out. A statistical analysis of the experiment was carried out. Found the most accurate mathematical model that allows you to predict the values of the parameters of the state of the object Y and optimize its parameters in further studies depending on the factors Xi. Based on the obtained data, the design of the filter-heat exchanger with the heat exchange part built into the air cleaner is modeled. Conducted experimental studies in the filter-heat exchanger. The description of the experimental stand and methods of experimental research are given. The cleaning capacity of the filter-heat exchanger for the removal of various levels of PM2.5 pollution with the change of some parameters of the internal air environment (relative humidity, air exchange rate) per unit time is determined. Experimentally determined value of air cleaner Clean Air Delivery Rate for the predicted cleaning duration is not more than 1 hour. The regression equations for various cleaning parameters are determined by which the cleaning time will be determined with known input data (pollution levels, relative humidity, air cleaning performance). Forecasting can be used in smart home systems, in enterprises and in ventilation and air conditioning systems. Bibl. 21, Fig. 7, Tab. 2.
- 9 August 2024
- Published by Springer Nature
- p. 426-435
Experimental Study of the Aerodynamic Characteristics of a Solar Air Collector with an Absorber Made of Carbon Textile
- 9 August 2024
- Published by Springer Nature
- p. 426-435
Experimental Study of the Aerodynamic Characteristics of a Solar Air Collector with an Absorber Made of Carbon Textile
- Open Access
- 25 July 2024
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 48, 21-31
Effectiveness of the recirculation air cleaner in real conditions at variation of the air flow and PM2.5 content
Technical data on the effectiveness of air purifiers are usually obtained in laboratory conditions in special aerosol stands with test chambers or boxes of a small volume, while in real conditions the purifiers are used in rooms with a volume of at least 40-60 m3 with a permanent presence of people (distribution respiratory diseases emitted with breathing) and entry of PM2.5..PM10 particles into the room from working equipment (printers, chargers, power tools, etc.). There are already enough scientific materials on this matter, which prove that the actual efficiency of air purifiers in real conditions is much lower than the data given by the manufacturers. Therefore, there is a need to determine the optimal performance of the air purifier in real conditions in order to achieve the WHO recommended levels of safe indoor pollution with a maximum time interval of 1 hour, besides, taking into account that the air outside has a higher level of pollution with particles of PM 2.5. In this study, we strive to obtain a PM 2.5 value of 5 μg/m3 with a PM2.5 level in the air outside of 16.7 μg/m3. The calculated value of CADR for light pollution should be at least half of the power of the air purifier for the projected cleaning duration of no more than 1 hour. A smaller value of CADR leads to further accumulation of pollutants, which reduces the work of the cleaner. In this study, the value of CADR was at L=100 m3/hour the value of CADR= 59 m3/hour with the efficiency of filter inserts in 73% and natural sedimentation of particles in 25%, and at L=310 m3/hour the value of CADR= 59 m3/hour at efficiency of filter inserts in 94% and natural sedimentation of particles in 18%. The process of natural deposition and the amount of external pollution do not allow to clean the air without the use of mechanical filtration for any of the pollutants specified in the study.
- 25 July 2024
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 48, 21-31
Open AccessEffectiveness of the recirculation air cleaner in real conditions at variation of the air flow and PM2.5 content
Technical data on the effectiveness of air purifiers are usually obtained in laboratory conditions in special aerosol stands with test chambers or boxes of a small volume, while in real conditions the purifiers are used in rooms with a volume of at least 40-60 m3 with a permanent presence of people (distribution respiratory diseases emitted with breathing) and entry of PM2.5..PM10 particles into the room from working equipment (printers, chargers, power tools, etc.). There are already enough scientific materials on this matter, which prove that the actual efficiency of air purifiers in real conditions is much lower than the data given by the manufacturers. Therefore, there is a need to determine the optimal performance of the air purifier in real conditions in order to achieve the WHO recommended levels of safe indoor pollution with a maximum time interval of 1 hour, besides, taking into account that the air outside has a higher level of pollution with particles of PM 2.5. In this study, we strive to obtain a PM 2.5 value of 5 μg/m3 with a PM2.5 level in the air outside of 16.7 μg/m3. The calculated value of CADR for light pollution should be at least half of the power of the air purifier for the projected cleaning duration of no more than 1 hour. A smaller value of CADR leads to further accumulation of pollutants, which reduces the work of the cleaner. In this study, the value of CADR was at L=100 m3/hour the value of CADR= 59 m3/hour with the efficiency of filter inserts in 73% and natural sedimentation of particles in 25%, and at L=310 m3/hour the value of CADR= 59 m3/hour at efficiency of filter inserts in 94% and natural sedimentation of particles in 18%. The process of natural deposition and the amount of external pollution do not allow to clean the air without the use of mechanical filtration for any of the pollutants specified in the study.
- Open Access
- 11 February 2024
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 46, 18-27
Air exchange rate as a means of ensure requirements to air purity on the basis of high-efficiency filters
In the context of a constant increase in air pollution, the question arises of creating safe air zones with quality control of the air environment in places where people stay. The constant deterioration of air quality caused by military operations and their consequences, as well as the need to reduce the consumption of available energy resources, requires studying the recommendations on the optimal air exchange rate of existing European and American air quality requirements in residential and office buildings to achieve the required air quality with minimal energy consumption. The objectives of the study were to obtain data on the efficiency of air purification in a given volume at different air exchange rates. A separate task was to check the data declared by the manufacturer on the pressure drop across the filter with an increase in the volume of air passing through it. CleanZone5300 filtration systems with F9 class filter and HEPA H12/13 class filter were considered, which can provide an air exchange rate of 2 to 10 times. In a room volume of 225.9 m3, at a temperature of 18 ˚C, a relative humidity of 57-59 % and an initial number of particles in the room air of 533,440 particles/ft3 (15105 particles/m3), the ability of filtration units to purify the air at different rates was studied. It was concluded that even with a factor of 2, the filtration system can provide air purification up to 40 % when using the F9 filter and up to 60 % when using the HEPA H12/13 filter in a short period of time. Recirculation filter units are considered as the easiest way to increase the air exchange rate in the room, in our climatic conditions. With the possibility of avoiding the processing of air for heating or cooling when using outside atmospheric air. In the installations used in the study, the electrical power consumption of the fans is 300 W per hour. The conclusions of the study need to be tested in office premises with an existing ventilation system to determine the optimal multiplicity of achieving a given air quality when using filters or portable filter units.
- 11 February 2024
- Published by Kyiv National University of Construction and Architecture in Ventilation, Illumination and Heat Gas Supply
- Vol. 46, 18-27
Open AccessAir exchange rate as a means of ensure requirements to air purity on the basis of high-efficiency filters
In the context of a constant increase in air pollution, the question arises of creating safe air zones with quality control of the air environment in places where people stay. The constant deterioration of air quality caused by military operations and their consequences, as well as the need to reduce the consumption of available energy resources, requires studying the recommendations on the optimal air exchange rate of existing European and American air quality requirements in residential and office buildings to achieve the required air quality with minimal energy consumption. The objectives of the study were to obtain data on the efficiency of air purification in a given volume at different air exchange rates. A separate task was to check the data declared by the manufacturer on the pressure drop across the filter with an increase in the volume of air passing through it. CleanZone5300 filtration systems with F9 class filter and HEPA H12/13 class filter were considered, which can provide an air exchange rate of 2 to 10 times. In a room volume of 225.9 m3, at a temperature of 18 ˚C, a relative humidity of 57-59 % and an initial number of particles in the room air of 533,440 particles/ft3 (15105 particles/m3), the ability of filtration units to purify the air at different rates was studied. It was concluded that even with a factor of 2, the filtration system can provide air purification up to 40 % when using the F9 filter and up to 60 % when using the HEPA H12/13 filter in a short period of time. Recirculation filter units are considered as the easiest way to increase the air exchange rate in the room, in our climatic conditions. With the possibility of avoiding the processing of air for heating or cooling when using outside atmospheric air. In the installations used in the study, the electrical power consumption of the fans is 300 W per hour. The conclusions of the study need to be tested in office premises with an existing ventilation system to determine the optimal multiplicity of achieving a given air quality when using filters or portable filter units.
- 26 October 2023
- Published by Springer Nature
- p. 392-398
Integrated Solar Collectors in External Protection for Energy-Efficient Buildings
- 26 October 2023
- Published by Springer Nature
- p. 392-398
Integrated Solar Collectors in External Protection for Energy-Efficient Buildings