Izabela Kiełb-Sotkiewicz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Izabela Kiełb-Sotkiewicz has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- Justyna Zamorska
Rzeszów University of Technology
3 shared publications
Latest Publications
- Open Access
- 14 December 2023
- Published by University of Zielona Góra, Poland in Civil and Environmental Engineering Reports
- Vol. 33 (3) , 63-75
Ozonation in Wastewater Disinfection
Due to the potential microbiological hazard associated with discharging treated sewage into the receiving body, its disinfection is a key issue to protect ecological safety and human health. Water scarcity and drinking water supply, irrigation, rapid industrialization, use of treated water, protection of water sources, overpopulation and environmental protection force us to look for solutions to ensure safe reuse of wastewater, and this depends primarily on the quality of wastewater disinfection. Many wastewater disinfection methods are commonly used. One of the chemical processes of disinfection sludge is ozonation. Ozonation is widely used in wastewater treatment by oxidation, because ozone is a very strong and effective oxidizing agent. Studies have shown that the effectiveness of ozone in disinfecting water and sewage is up to 50% greater than that of chlorine . An additional advantage of this method is that it also eliminates odors that may be unavailable. The article presents the results of research on the effectiveness of ozonation treatment in the disinfection of treated sewage, based on indicator bacteria such as coliforms, including Escherichia coli, mesophiles, psychrophiles, and spores. The study took into account various effects of time (dose) and temperature. For the purpose of this study, both traditional and modern methods of assessing microbiological quality of wastewater were used. The first one is represented by conventional culture measurements and the second one by using a luminometer (ATP) and flow cytometer (FCM).
- 14 December 2023
- Published by University of Zielona Góra, Poland in Civil and Environmental Engineering Reports
- Vol. 33 (3) , 63-75
Open AccessOzonation in Wastewater Disinfection
Due to the potential microbiological hazard associated with discharging treated sewage into the receiving body, its disinfection is a key issue to protect ecological safety and human health. Water scarcity and drinking water supply, irrigation, rapid industrialization, use of treated water, protection of water sources, overpopulation and environmental protection force us to look for solutions to ensure safe reuse of wastewater, and this depends primarily on the quality of wastewater disinfection. Many wastewater disinfection methods are commonly used. One of the chemical processes of disinfection sludge is ozonation. Ozonation is widely used in wastewater treatment by oxidation, because ozone is a very strong and effective oxidizing agent. Studies have shown that the effectiveness of ozone in disinfecting water and sewage is up to 50% greater than that of chlorine . An additional advantage of this method is that it also eliminates odors that may be unavailable. The article presents the results of research on the effectiveness of ozonation treatment in the disinfection of treated sewage, based on indicator bacteria such as coliforms, including Escherichia coli, mesophiles, psychrophiles, and spores. The study took into account various effects of time (dose) and temperature. For the purpose of this study, both traditional and modern methods of assessing microbiological quality of wastewater were used. The first one is represented by conventional culture measurements and the second one by using a luminometer (ATP) and flow cytometer (FCM).
- Open Access
A Biological Method of Treating Surface Water Contaminated with Industrial Waste Leachate
The progressive chemicalization of all areas of everyday life and the development of the industry cause the appearance of various types of pollutants, both in groundwater and surface waters. Kalina Pond (Świętochłowice, Poland) is an example of a degraded water reservoir as a result of many years of activity, among others hard coal mines, storing metallurgical waste by zinc plants, and the activities of the Hajduki Chemical Plants from Chorzów. Inadequate securing of waste heaps resulted in the penetration of pollutants, i.e., phenol, petroleum compounds, PAHs, cyanides, and heavy metals. The aim of the research was to determine the suitability of biopreparations for the removal of pollutants. The research used a bacterial biopreparation from BioArcus, “DBC plus type R5”, to remove petroleum compounds and phenol. Then, in order to restore the microbiological balance, “ACS ODO-1” from the biopreparation was used. The research was carried out in laboratory conditions, using three variants: direct dosing of biopreparations, dosing of biopreparations previously activated by multiplication on the medium, and dosing of biopreparations into water after filtration on a diatomite bed. The optimal method of recultivating water from a reservoir was to filter this water through a diatomite bed and then dose the multiplied bacteria. After the filtration process, the obtained percentage of TOC reduction allowed for the rapid development of microorganisms from the biopreparation, despite the 100 times lower dose used. In addition, the application of lyophilized biopreparation to contaminated water resulted in a very fast biodegradation effect of pollutants, despite the high concentration of numerous toxic compounds.
Open AccessA Biological Method of Treating Surface Water Contaminated with Industrial Waste Leachate
The progressive chemicalization of all areas of everyday life and the development of the industry cause the appearance of various types of pollutants, both in groundwater and surface waters. Kalina Pond (Świętochłowice, Poland) is an example of a degraded water reservoir as a result of many years of activity, among others hard coal mines, storing metallurgical waste by zinc plants, and the activities of the Hajduki Chemical Plants from Chorzów. Inadequate securing of waste heaps resulted in the penetration of pollutants, i.e., phenol, petroleum compounds, PAHs, cyanides, and heavy metals. The aim of the research was to determine the suitability of biopreparations for the removal of pollutants. The research used a bacterial biopreparation from BioArcus, “DBC plus type R5”, to remove petroleum compounds and phenol. Then, in order to restore the microbiological balance, “ACS ODO-1” from the biopreparation was used. The research was carried out in laboratory conditions, using three variants: direct dosing of biopreparations, dosing of biopreparations previously activated by multiplication on the medium, and dosing of biopreparations into water after filtration on a diatomite bed. The optimal method of recultivating water from a reservoir was to filter this water through a diatomite bed and then dose the multiplied bacteria. After the filtration process, the obtained percentage of TOC reduction allowed for the rapid development of microorganisms from the biopreparation, despite the 100 times lower dose used. In addition, the application of lyophilized biopreparation to contaminated water resulted in a very fast biodegradation effect of pollutants, despite the high concentration of numerous toxic compounds.