Samaneh Mostafapour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Samaneh Mostafapour has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Adriaan A. Lammertsma
University Medical Center Groningen, University of Groningen
3 shared publications - Charalampos Tsoumpas
University Medical Center Groningen, University of Groningen
3 shared publications Joyce van Sluis
Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands; and
3 shared publicationsAdriaan A. Lammertsma
Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands; and
2 shared publications- Adrienne H. Brouwers
Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
2 shared publications - Andor W. J. M. Glaudemans
Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
2 shared publications
Latest Publications
- 3 October 2025
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 66 (12) , 1985-1992
Influence of Ultra-Low-Dose CT on PET Image Quantification and Visual Assessment
Recent advances in high-sensitivity PET allow for significantly reduced radiation doses, making the CT radiation dose a larger fraction of the total scan dose. This is the first study to the best of our knowledge that evaluates the feasibility and efficacy of an ultra-low-dose CT (ULD-CT) protocol, incorporating a Sn filter, by reducing radiation exposure while maintaining PET image quality and quantitative accuracy in oncology patients. Methods: The study involved 29 oncology patients. FDG PET/CT scans were performed using both low-dose CT (LD-CT) and ULD-CT protocols. The ULD-CT protocol used the Sn filter with 100 kVp and 6 mAs, whereas the LD-CT protocol, optimized for PET attenuation correction and anatomic localization, was performed without the Sn filter, using 100–120 kVp and 12–30 mAs. Quantitative and qualitative comparisons of PET images were made, focusing on SUVs, Patlak analysis, and diagnostic quality on different tissues. Results: The ULD-CT protocol reduced the CT radiation dose by 97%, from 1.93 ± 0.61 mSv to 0.059 ± 0.026 mSv. SUV comparisons showed relative variations of less than 3%. The net rate of influx values resulting from the Patlak reconstruction showed negligible differences across various tissues between ULD-CT and LD-CT PET reconstructions. Image quality assessments revealed no significant differences between ULD-CT and LD-CT PET reconstructions, with consistently high scores (greater than 4 on a 5-point Likert scale). Lesion detection analysis showed strong intraobserver agreement (intraclass correlation coefficient > 0.85) without significant differences in lesion localization. Conclusion: The ULD-CT protocol substantially reduces radiation exposure in PET/CT while maintaining diagnostic quality of PET scans and introducing negligible quantitative effects, thereby paving the way for optimizing CT radiation protocols in PET/CT imaging. Visual Abstract
- 3 October 2025
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 66 (12) , 1985-1992
Influence of Ultra-Low-Dose CT on PET Image Quantification and Visual Assessment
Recent advances in high-sensitivity PET allow for significantly reduced radiation doses, making the CT radiation dose a larger fraction of the total scan dose. This is the first study to the best of our knowledge that evaluates the feasibility and efficacy of an ultra-low-dose CT (ULD-CT) protocol, incorporating a Sn filter, by reducing radiation exposure while maintaining PET image quality and quantitative accuracy in oncology patients. Methods: The study involved 29 oncology patients. FDG PET/CT scans were performed using both low-dose CT (LD-CT) and ULD-CT protocols. The ULD-CT protocol used the Sn filter with 100 kVp and 6 mAs, whereas the LD-CT protocol, optimized for PET attenuation correction and anatomic localization, was performed without the Sn filter, using 100–120 kVp and 12–30 mAs. Quantitative and qualitative comparisons of PET images were made, focusing on SUVs, Patlak analysis, and diagnostic quality on different tissues. Results: The ULD-CT protocol reduced the CT radiation dose by 97%, from 1.93 ± 0.61 mSv to 0.059 ± 0.026 mSv. SUV comparisons showed relative variations of less than 3%. The net rate of influx values resulting from the Patlak reconstruction showed negligible differences across various tissues between ULD-CT and LD-CT PET reconstructions. Image quality assessments revealed no significant differences between ULD-CT and LD-CT PET reconstructions, with consistently high scores (greater than 4 on a 5-point Likert scale). Lesion detection analysis showed strong intraobserver agreement (intraclass correlation coefficient > 0.85) without significant differences in lesion localization. Conclusion: The ULD-CT protocol substantially reduces radiation exposure in PET/CT while maintaining diagnostic quality of PET scans and introducing negligible quantitative effects, thereby paving the way for optimizing CT radiation protocols in PET/CT imaging. Visual Abstract
- Open Access
- 13 February 2025
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 66 (4) , 663.2-663
176Lu Radiation Dose of Long–Axial Field of View PET Scanners
- 13 February 2025
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 66 (4) , 663.2-663
Open Access176Lu Radiation Dose of Long–Axial Field of View PET Scanners
- Open Access
- 13 November 2024
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 55 (1) , 52-66
Long Axial Field of View PET/CT: Technical Aspects in Cardiovascular Diseases
- 13 November 2024
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 55 (1) , 52-66
Open AccessLong Axial Field of View PET/CT: Technical Aspects in Cardiovascular Diseases
- 8 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Evaluation of Automatic Segmentation Tools on Low-Dose and Ultra-Low-Dose CT Images in PET/CT Scans
The use of Ultra-Low-Dose computed tomography (ULD-CT) in PET/CT imaging is gaining attention due to its potential to significantly reduce radiation exposure, which is crucial for patient safety. Accurate organ segmentation is essential for treatment planning, particularly in radiotherapy where it aids in delineating target volumes and organs at risk. This study investigated the reproducibility of organ segmentation on ULD-CT in PET/CT imaging. In a cohort of 28 patients undergoing [18F]FDG PET/CT scans, segmentation outcomes were compared between standard low-dose CT (LD-CT) and ULD-CT images. Segmentations were performed using the TotalSegmentator and MOOSE tools, and accuracy was quantified using metrics such as the Dice coefficient, Jaccard index, and Hausdorff and Average distance. Results indicated that ULD-CT, despite its significantly reduced radiation dose and increased image noise, achieved comparable segmentation accuracy to LD-CT for most anatomical structures, with Dice coefficients and Jaccard indices maintaining high values across segmented organs. However, lower reproducibility was observed for structures like the kidneys, and aorta, potentially due to the presence of adjacent structures with similar intensities, making accurate boundary delineation more challenging, especially in the noisy ULD-CT images. Quantitative PET analyses, represented by SUVmean and SUVmax, also showed consistent results between LD-CT and ULD-CT reconstructions. However, the segmentation tools exhibited some errors even on the LD-CT images, that means there are areas for further improvement in these tools. Overall, the study emphasizes that ULD-CT does not compromise the use of automatic segmentation tools like TotaSegmentator and Moose, maintaining the clinical utility of PET/CT scans for most anatomical structures while reducing radiation exposure.
- 8 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Evaluation of Automatic Segmentation Tools on Low-Dose and Ultra-Low-Dose CT Images in PET/CT Scans
The use of Ultra-Low-Dose computed tomography (ULD-CT) in PET/CT imaging is gaining attention due to its potential to significantly reduce radiation exposure, which is crucial for patient safety. Accurate organ segmentation is essential for treatment planning, particularly in radiotherapy where it aids in delineating target volumes and organs at risk. This study investigated the reproducibility of organ segmentation on ULD-CT in PET/CT imaging. In a cohort of 28 patients undergoing [18F]FDG PET/CT scans, segmentation outcomes were compared between standard low-dose CT (LD-CT) and ULD-CT images. Segmentations were performed using the TotalSegmentator and MOOSE tools, and accuracy was quantified using metrics such as the Dice coefficient, Jaccard index, and Hausdorff and Average distance. Results indicated that ULD-CT, despite its significantly reduced radiation dose and increased image noise, achieved comparable segmentation accuracy to LD-CT for most anatomical structures, with Dice coefficients and Jaccard indices maintaining high values across segmented organs. However, lower reproducibility was observed for structures like the kidneys, and aorta, potentially due to the presence of adjacent structures with similar intensities, making accurate boundary delineation more challenging, especially in the noisy ULD-CT images. Quantitative PET analyses, represented by SUVmean and SUVmax, also showed consistent results between LD-CT and ULD-CT reconstructions. However, the segmentation tools exhibited some errors even on the LD-CT images, that means there are areas for further improvement in these tools. Overall, the study emphasizes that ULD-CT does not compromise the use of automatic segmentation tools like TotaSegmentator and Moose, maintaining the clinical utility of PET/CT scans for most anatomical structures while reducing radiation exposure.
- Open Access
Current and Future Use of Long Axial Field-of-View Positron Emission Tomography/Computed Tomography Scanners in Clinical Oncology
The latest technical development in the field of positron emission tomography/computed tomography (PET/CT) imaging has been the extension of the PET axial field-of-view. As a result of the increased number of detectors, the long axial field-of-view (LAFOV) PET systems are not only characterized by a larger anatomical coverage but also by a substantially improved sensitivity, compared with conventional short axial field-of-view PET systems. In clinical practice, this innovation has led to the following optimization: (1) improved overall image quality, (2) decreased duration of PET examinations, (3) decreased amount of radioactivity administered to the patient, or (4) a combination of any of the above. In this review, novel applications of LAFOV PET in oncology are highlighted and future directions are discussed.
Open AccessCurrent and Future Use of Long Axial Field-of-View Positron Emission Tomography/Computed Tomography Scanners in Clinical Oncology
The latest technical development in the field of positron emission tomography/computed tomography (PET/CT) imaging has been the extension of the PET axial field-of-view. As a result of the increased number of detectors, the long axial field-of-view (LAFOV) PET systems are not only characterized by a larger anatomical coverage but also by a substantially improved sensitivity, compared with conventional short axial field-of-view PET systems. In clinical practice, this innovation has led to the following optimization: (1) improved overall image quality, (2) decreased duration of PET examinations, (3) decreased amount of radioactivity administered to the patient, or (4) a combination of any of the above. In this review, novel applications of LAFOV PET in oncology are highlighted and future directions are discussed.