Matthias Söhn
Matthias Söhn has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Claus Belka
Department of Radiation Oncology, University Hospital LMU, Marchioninistrasse 15, Munich, 81377, Germany, 49 89440073770
3 shared publications Markus Alber
Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; Heidelberg Institute for Radiation Oncology (HIRO), Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; Scientific-RT GmbH, Welserstr. 7, 81373 München, Germany
3 shared publicationsChristian Heinz
Department of Radiation Oncology, University Hospital, LMU Munich, D-81377 Munich, Germany
1 shared publication- Falk Roeder
Department of Radiation Oncology, Paracelsus Medical University, 5020 Salzburg, Austria
1 shared publication - Hendrik Ballhausen
Department of Radiation Oncology, LMU University Hospital, LMU Munich, 81377 Munich, Germany
1 shared publication Henrike von Zimmermann
Department of Radiation Oncology, University Hospital, LMU Munich, D-81377 Munich, Germany
1 shared publication
Latest Publications
- Open Access
- 25 October 2023
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 35 (3) , 259-269
Sensitivity and specificity of Monte Carlo based independent secondary dose computation for detecting modulation-related dose errors in intensity modulated radiotherapy
- 25 October 2023
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 35 (3) , 259-269
Open AccessSensitivity and specificity of Monte Carlo based independent secondary dose computation for detecting modulation-related dose errors in intensity modulated radiotherapy
- Open Access
- 25 October 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (11) , 304-311
Commissioning and clinical implementation of the first commercial independent Monte Carlo 3D dose calculation to replace CyberKnife M6™ patient‐specific QA measurements
Purpose: To report on the commissioning and clinical validation of the first commercially available independent Monte Carlo (MC) three‐dimensional (3D) dose calculation for CyberKnife robotic radiosurgery system® (Accuray, Sunnyvale, CA).Methods: The independent dose calculation (IDC) by SciMoCa® (Scientific RT, Munich, Germany) was validated based on water measurements of output factors and dose profiles (unshielded diode, field‐size dependent corrections). A set of 84 patient‐specific quality assurance (QA) measurements for multi‐leaf collimator (MLC) plans, using an Octavius two‐dimensional SRS1000 array (PTW, Freiburg, Germany), was compared to results of respective calculations. Statistical process control (SPC) was used to detect plans outside action levels.Results: Of all output factors for the three collimator systems of the CyberKnife, 99% agreed within 2% and 81% within 1%, with a maximum deviation of 3.2% for a 5‐mm fixed cone. The profiles were compared using a one‐dimensional gamma evaluation with 2% dose difference and 0.5 mm distance‐to‐agreement (Γ(2,0.5)). The off‐centre ratios showed an average pass rate >99% (92–100%). The agreement of the depth dose profiles depended on field size, with lowest pass rates for the smallest MLC field sizes. The average depth dose pass rate was 88% (35–99%). The IDCs showed a Γ(2,1) pass rate of 98%. Statistical process control detected six plans outside tolerance levels in the measurements, all of which could be attributed the measurement setup. Independent dose calculations showed problems in five plans, all due to differences in the algorithm between TPS and IDC. Based on these results changes were made in the class solution for treatment plans.Conclusion: The first commercially available MC 3D dose IDC was successfully commissioned and validated for the CyberKnife and replaced all routine patient‐specific QA measurements in our clinic.
- 25 October 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (11) , 304-311
Open AccessCommissioning and clinical implementation of the first commercial independent Monte Carlo 3D dose calculation to replace CyberKnife M6™ patient‐specific QA measurements
Purpose: To report on the commissioning and clinical validation of the first commercially available independent Monte Carlo (MC) three‐dimensional (3D) dose calculation for CyberKnife robotic radiosurgery system® (Accuray, Sunnyvale, CA).Methods: The independent dose calculation (IDC) by SciMoCa® (Scientific RT, Munich, Germany) was validated based on water measurements of output factors and dose profiles (unshielded diode, field‐size dependent corrections). A set of 84 patient‐specific quality assurance (QA) measurements for multi‐leaf collimator (MLC) plans, using an Octavius two‐dimensional SRS1000 array (PTW, Freiburg, Germany), was compared to results of respective calculations. Statistical process control (SPC) was used to detect plans outside action levels.Results: Of all output factors for the three collimator systems of the CyberKnife, 99% agreed within 2% and 81% within 1%, with a maximum deviation of 3.2% for a 5‐mm fixed cone. The profiles were compared using a one‐dimensional gamma evaluation with 2% dose difference and 0.5 mm distance‐to‐agreement (Γ(2,0.5)). The off‐centre ratios showed an average pass rate >99% (92–100%). The agreement of the depth dose profiles depended on field size, with lowest pass rates for the smallest MLC field sizes. The average depth dose pass rate was 88% (35–99%). The IDCs showed a Γ(2,1) pass rate of 98%. Statistical process control detected six plans outside tolerance levels in the measurements, all of which could be attributed the measurement setup. Independent dose calculations showed problems in five plans, all due to differences in the algorithm between TPS and IDC. Based on these results changes were made in the class solution for treatment plans.Conclusion: The first commercially available MC 3D dose IDC was successfully commissioned and validated for the CyberKnife and replaced all routine patient‐specific QA measurements in our clinic.
- 1 April 2018
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 28 (2) , 88-95
Clinical workflow optimization to improve 4DCT reconstruction for Toshiba Aquilion CT scanners
- 1 April 2018
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 28 (2) , 88-95
Clinical workflow optimization to improve 4DCT reconstruction for Toshiba Aquilion CT scanners
- Open Access
- 13 December 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 287
Analysis of equivalent uniform dose (EUD) and conventional radiation treatment parameters after primary and re-irradiation of malignant glioma
Re-irradiation is a reasonable second treatment option for patients with recurrent malignant glioma (MG) after previous radio(chemo)therapy. However, only limited data is available allowing for a precise selection of patients suitable for re-treatment in regard to safety and efficacy.
- 13 December 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 287
Open AccessAnalysis of equivalent uniform dose (EUD) and conventional radiation treatment parameters after primary and re-irradiation of malignant glioma
Re-irradiation is a reasonable second treatment option for patients with recurrent malignant glioma (MG) after previous radio(chemo)therapy. However, only limited data is available allowing for a precise selection of patients suitable for re-treatment in regard to safety and efficacy.
- 18 March 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (7) , 2413-2427
The random walk model of intrafraction movement
The purpose of this paper is to understand intrafraction movement as a stochastic process driven by random external forces. The hypothetically proposed three-dimensional random walk model has significant impact on optimal PTV margins and offers a quantitatively correct explanation of experimental findings. Properties of the random walk are calculated from first principles, in particular fraction-average population density distributions for displacements along the principal axes. When substituted into the established optimal margin recipes these fraction-average distributions yield safety margins about 30% smaller as compared to the suggested values from end-of-fraction gaussian fits. Stylized facts of a random walk are identified in clinical data, such as the increase of the standard deviation of displacements with the square root of time. Least squares errors in the comparison to experimental results are reduced by about 50% when accounting for non-gaussian corrections from the random walk model.
- 18 March 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (7) , 2413-2427
The random walk model of intrafraction movement
The purpose of this paper is to understand intrafraction movement as a stochastic process driven by random external forces. The hypothetically proposed three-dimensional random walk model has significant impact on optimal PTV margins and offers a quantitatively correct explanation of experimental findings. Properties of the random walk are calculated from first principles, in particular fraction-average population density distributions for displacements along the principal axes. When substituted into the established optimal margin recipes these fraction-average distributions yield safety margins about 30% smaller as compared to the suggested values from end-of-fraction gaussian fits. Stylized facts of a random walk are identified in clinical data, such as the increase of the standard deviation of displacements with the square root of time. Least squares errors in the comparison to experimental results are reduced by about 50% when accounting for non-gaussian corrections from the random walk model.
- Open Access
- 12 December 2009
- Published by Springer Nature in Radiation Oncology
- Vol. 4 (1) , 64
Monte Carlo vs. Pencil Beam based optimization of stereotactic lung IMRT
The purpose of the present study is to compare finite size pencil beam (fsPB) and Monte Carlo (MC) based optimization of lung intensity-modulated stereotactic radiotherapy (lung IMSRT).
- 12 December 2009
- Published by Springer Nature in Radiation Oncology
- Vol. 4 (1) , 64
Open AccessMonte Carlo vs. Pencil Beam based optimization of stereotactic lung IMRT
The purpose of the present study is to compare finite size pencil beam (fsPB) and Monte Carlo (MC) based optimization of lung intensity-modulated stereotactic radiotherapy (lung IMSRT).
- 10 September 2009
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 75 (3) , 906-914
Intensity-Modulated Radiotherapy Optimization in a Quasi-Periodically Deforming Patient Model
- 10 September 2009
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 75 (3) , 906-914
Intensity-Modulated Radiotherapy Optimization in a Quasi-Periodically Deforming Patient Model