Thomas Aper
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Thomas Aper has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Axel Haverich
Department for Cardiothoracic-, Transplantation and Vascular Surgery, Division for Vascular and Endovascular Surgery, Hannover Medical School, Hannover, Germany; Lower Saxony Centre for Biomedical Engineering, Implant Research and Development (NIFE), Hannover, Germany
4 shared publicationsAndres Hilfiker
Department of Vascular and Endovascular Surgery, Division for Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
3 shared publicationsMathias Wilhelmi
Department of Vascular and Endovascular Surgery, Division for Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
3 shared publications- Mathias Wilhelmi
Lower Saxony Center for Biomedical Engineering, Implant Research and Development (NIFE), Stadtfelddamm 34, 30625 Hannover, Germany
3 shared publications Nils Benecke
Department of Vascular and Endovascular Surgery, Division for Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
3 shared publicationsA. Haverich
Klinik für Herz-, Thorax-, Transplantations- und Gefäßchirurgie, Medizinische Hochschule Hannover, Hannover, Deutschland
2 shared publications
Latest Publications
- Open Access
- 14 November 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (11) , 1147
An Arteriovenous Bioreactor Perfusion System for Physiological In Vitro Culture of Complex Vascularized Tissue Constructs
Background: The generation and perfusion of complex vascularized tissues in vitro requires sophisticated perfusion techniques. For multiscale arteriovenous networks, not only the arterial, but also the venous, biomechanical and biochemical conditions that physiologically exist in the human body must be accurately emulated. For this, we here present a modular arteriovenous perfusion system for the in vitro culture of a multi-scale bioartificial vascular network. Methods: The custom-built perfusion system consisted of two circuits: in the arterial circuit, physiological arterial biomechanical and biochemical conditions were simulated using a modular set-up with a pulsatile peristaltic pump, compliance chambers, and resistors. In the venous circuit, venous conditions were emulated accordingly. In the center of the system, a bioartificial multi-scale vascularized fibrin-based tissue was perfused by both circuits simultaneously under biomimetic arteriovenous conditions. Culture conditions were monitored continuously using a multi-sensor monitoring system. Results: The physiological arterial and venous pressure- and flow-curves, as well as the microvascular arteriovenous oxygen partial pressure gradient, were accurately emulated in the perfusion system. The multi-sensor monitoring system facilitated live monitoring of the respective parameters and data-logging. In a proof-of-concept experiment, vascularized three-dimensional fibrin tissues showed sustained cell viability and homogenous microvessel formation after culture in the perfusion system. Conclusions: The arteriovenous perfusion system facilitated the in vitro culture of a multiscale vascularized tissue under physiological pressure-, flow-, and oxygen-gradient conditions. With that, it presents a promising technique for the in vitro generation and culture of complex large-scale vascularized tissues.
- 14 November 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (11) , 1147
Open AccessAn Arteriovenous Bioreactor Perfusion System for Physiological In Vitro Culture of Complex Vascularized Tissue Constructs
Background: The generation and perfusion of complex vascularized tissues in vitro requires sophisticated perfusion techniques. For multiscale arteriovenous networks, not only the arterial, but also the venous, biomechanical and biochemical conditions that physiologically exist in the human body must be accurately emulated. For this, we here present a modular arteriovenous perfusion system for the in vitro culture of a multi-scale bioartificial vascular network. Methods: The custom-built perfusion system consisted of two circuits: in the arterial circuit, physiological arterial biomechanical and biochemical conditions were simulated using a modular set-up with a pulsatile peristaltic pump, compliance chambers, and resistors. In the venous circuit, venous conditions were emulated accordingly. In the center of the system, a bioartificial multi-scale vascularized fibrin-based tissue was perfused by both circuits simultaneously under biomimetic arteriovenous conditions. Culture conditions were monitored continuously using a multi-sensor monitoring system. Results: The physiological arterial and venous pressure- and flow-curves, as well as the microvascular arteriovenous oxygen partial pressure gradient, were accurately emulated in the perfusion system. The multi-sensor monitoring system facilitated live monitoring of the respective parameters and data-logging. In a proof-of-concept experiment, vascularized three-dimensional fibrin tissues showed sustained cell viability and homogenous microvessel formation after culture in the perfusion system. Conclusions: The arteriovenous perfusion system facilitated the in vitro culture of a multiscale vascularized tissue under physiological pressure-, flow-, and oxygen-gradient conditions. With that, it presents a promising technique for the in vitro generation and culture of complex large-scale vascularized tissues.
- Open Access
- 2 February 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 152, 106433
Fabrication and biomechanical characterization of a spider silk reinforced fibrin-based vascular prosthesis
- 2 February 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 152, 106433
Open AccessFabrication and biomechanical characterization of a spider silk reinforced fibrin-based vascular prosthesis
- Open Access
- 1 September 2018
- Published by Walter de Gruyter GmbH in Innovative Surgical Sciences
- Vol. 3 (3) , 215-+
Dehydration improves biomechanical strength of bioartificial vascular graft material and allows its long-term storage
Introduction: We have recently reported about a novel technique for the generation of bioartificial vascular grafts based on the use of a compacted fibrin matrix. In this study, we evaluated the effects of a dehydration process on the biomechanical properties of compacted fibrin tubes and whether it allows for their long-term storage. Materials and methods: Fibrin was precipitated from fresh frozen plasma by means of cryoprecipitation and simultaneously with a thrombin solution applied in a high-speed rotating casting mold. Subsequent dehydration of the fibrin tubes (29/38) was performed in dry air with a dilator inside the tube to prevent the collapse of the lumen. Dehydrated fibrin tubes were stored for six (n = 9) and 12 months (n = 10) at room temperature. Comparative analysis was done on initially generated and dehydrated fibrin tubes before and after storage to evaluate the effects of the dehydration process and storage on the biomechanical properties and structure of the tubes. Results: Thirty-eight fibrin tubes were generated by high-speed rotation-molding from 142 +/- 3 mg fibrinogen with an inner diameter of 5.8 +/- 0.1 mm and a length of 100 mm. A centrifugal force of nearly 900 x g compacted applied fibrin, while fluid was pressed out of the matrix and drained from the mold via holes resulting in a 16-fold compaction of the fibrin matrix. Dehydration was characterized by shrinkage of the tubes to a diameter of 3.2 +/- 0.2 mm, while the length remained at 100 mm equivalent to a further two-fold compaction. The biomechanical strength of the dehydrated fibrin tubes significantly increased to values comparable to that of native ovine carotid arteries and maintained during the first 6 months of storage. After 12 months of storage, only five of 10 tubes were intact, and only one showed maintained biomechanical strength. Discussion: Compaction of a fibrin matrix in high-speed rotation-moulding and subsequent dehydration enables for the construction of small-caliber fibrin grafts. Over and above, the dehydration process allows their storage and stockpiling as a prerequisite for clinical use.
- 1 September 2018
- Published by Walter de Gruyter GmbH in Innovative Surgical Sciences
- Vol. 3 (3) , 215-+
Open AccessDehydration improves biomechanical strength of bioartificial vascular graft material and allows its long-term storage
Introduction: We have recently reported about a novel technique for the generation of bioartificial vascular grafts based on the use of a compacted fibrin matrix. In this study, we evaluated the effects of a dehydration process on the biomechanical properties of compacted fibrin tubes and whether it allows for their long-term storage. Materials and methods: Fibrin was precipitated from fresh frozen plasma by means of cryoprecipitation and simultaneously with a thrombin solution applied in a high-speed rotating casting mold. Subsequent dehydration of the fibrin tubes (29/38) was performed in dry air with a dilator inside the tube to prevent the collapse of the lumen. Dehydrated fibrin tubes were stored for six (n = 9) and 12 months (n = 10) at room temperature. Comparative analysis was done on initially generated and dehydrated fibrin tubes before and after storage to evaluate the effects of the dehydration process and storage on the biomechanical properties and structure of the tubes. Results: Thirty-eight fibrin tubes were generated by high-speed rotation-molding from 142 +/- 3 mg fibrinogen with an inner diameter of 5.8 +/- 0.1 mm and a length of 100 mm. A centrifugal force of nearly 900 x g compacted applied fibrin, while fluid was pressed out of the matrix and drained from the mold via holes resulting in a 16-fold compaction of the fibrin matrix. Dehydration was characterized by shrinkage of the tubes to a diameter of 3.2 +/- 0.2 mm, while the length remained at 100 mm equivalent to a further two-fold compaction. The biomechanical strength of the dehydrated fibrin tubes significantly increased to values comparable to that of native ovine carotid arteries and maintained during the first 6 months of storage. After 12 months of storage, only five of 10 tubes were intact, and only one showed maintained biomechanical strength. Discussion: Compaction of a fibrin matrix in high-speed rotation-moulding and subsequent dehydration enables for the construction of small-caliber fibrin grafts. Over and above, the dehydration process allows their storage and stockpiling as a prerequisite for clinical use.
- 24 April 2017
- Published by Springer Nature in Indian Journal of Thoracic and Cardiovascular Surgery
- Vol. 16 (3) , 301-204
Intra-aortic balloon pump associated vascular complications in cardiac surgical patients: the past and the future
- 24 April 2017
- Published by Springer Nature in Indian Journal of Thoracic and Cardiovascular Surgery
- Vol. 16 (3) , 301-204
Intra-aortic balloon pump associated vascular complications in cardiac surgical patients: the past and the future
- Open Access
- 1 January 2017
- Published by SAGE Publications in Journal of Tissue Engineering
- Vol. 8
Outgrowing endothelial and smooth muscle cells for tissue engineering approaches
In recent years, circulating progenitors of endothelial cells and smooth muscle cells were identified in the peripheral blood. In our study, we evaluated the utilization of both cell types isolated and differentiated from peripheral porcine blood in terms for their use for tissue engineering purposes. By means of density gradient centrifugation, the monocyte fraction from porcine blood was separated, split, and cultivated with specific culture media with either endothelial cell growth medium-2 or smooth muscle cell growth medium-2 for the differentiation of endothelial cells or smooth muscle cells. Obtained cells were characterized at an early stage of cultivation before the first passage and a late stage (fourth passage) on the basis of the expression of the antigens CD31, CD34, CD45, nitric oxide synthase, and the contractile filaments smooth-muscle alpha-actin (sm-alpha-actin) and smoothelin. Functional characterization was done based on the secretion of nitric oxide, the formation of a coherent monolayer on polytetrafluoroethylene, and capillary sprouting. During cultivation in both endothelial cell growth medium-2 and smooth muscle cell growth medium-2, substantially two types of cells grew out: early outgrown CD45-positive cells, which disappeared during further cultivation, and in 85% (n = 17/20) of cultures cultivated with endothelial cell growth medium-2 colony-forming late outgrowth endothelial cells. During cultivation with smooth muscle cell growth medium-2 in 80% (n = 16/20) of isolations colony-forming late outgrowth smooth muscle cells entered the stage. Cultivation with either endothelial cell growth medium-2 or smooth muscle cell growth medium-2 had selective effect on the late outgrown cells to that effect that the number of CD31-positive cells increased from 34.8% ± 13% to 83.9% ± 8% in cultures cultivated with endothelial cell growth medium-2 and the number of sm-α-actin+ cells increased from 52.6% ± 18% to 88% ± 5% in cultures cultivated with smooth muscle cell growth medium-2, respectively. Functional analyses revealed significantly higher levels of nitric oxide secretion, endothelialization capacity, and capillary formation in not expanded cultures cultivated with endothelial cell growth medium-2 in comparison to later stages of cultivation and mature aortic cells. Blood seems to be a reliable and feasible source for the isolation of both endothelial and smooth muscle cells for application in tissue engineering approaches. Whereas, early co-cultures of early and late outgrowth cells provide functional advantages, the differentiation of cells can be directed selectively by the used culture medium for the expansion of highly proliferative late outgrowth endothelial cells and late outgrowth smooth muscle cells, respectively.
- 1 January 2017
- Published by SAGE Publications in Journal of Tissue Engineering
- Vol. 8
Open AccessOutgrowing endothelial and smooth muscle cells for tissue engineering approaches
In recent years, circulating progenitors of endothelial cells and smooth muscle cells were identified in the peripheral blood. In our study, we evaluated the utilization of both cell types isolated and differentiated from peripheral porcine blood in terms for their use for tissue engineering purposes. By means of density gradient centrifugation, the monocyte fraction from porcine blood was separated, split, and cultivated with specific culture media with either endothelial cell growth medium-2 or smooth muscle cell growth medium-2 for the differentiation of endothelial cells or smooth muscle cells. Obtained cells were characterized at an early stage of cultivation before the first passage and a late stage (fourth passage) on the basis of the expression of the antigens CD31, CD34, CD45, nitric oxide synthase, and the contractile filaments smooth-muscle alpha-actin (sm-alpha-actin) and smoothelin. Functional characterization was done based on the secretion of nitric oxide, the formation of a coherent monolayer on polytetrafluoroethylene, and capillary sprouting. During cultivation in both endothelial cell growth medium-2 and smooth muscle cell growth medium-2, substantially two types of cells grew out: early outgrown CD45-positive cells, which disappeared during further cultivation, and in 85% (n = 17/20) of cultures cultivated with endothelial cell growth medium-2 colony-forming late outgrowth endothelial cells. During cultivation with smooth muscle cell growth medium-2 in 80% (n = 16/20) of isolations colony-forming late outgrowth smooth muscle cells entered the stage. Cultivation with either endothelial cell growth medium-2 or smooth muscle cell growth medium-2 had selective effect on the late outgrown cells to that effect that the number of CD31-positive cells increased from 34.8% ± 13% to 83.9% ± 8% in cultures cultivated with endothelial cell growth medium-2 and the number of sm-α-actin+ cells increased from 52.6% ± 18% to 88% ± 5% in cultures cultivated with smooth muscle cell growth medium-2, respectively. Functional analyses revealed significantly higher levels of nitric oxide secretion, endothelialization capacity, and capillary formation in not expanded cultures cultivated with endothelial cell growth medium-2 in comparison to later stages of cultivation and mature aortic cells. Blood seems to be a reliable and feasible source for the isolation of both endothelial and smooth muscle cells for application in tissue engineering approaches. Whereas, early co-cultures of early and late outgrowth cells provide functional advantages, the differentiation of cells can be directed selectively by the used culture medium for the expansion of highly proliferative late outgrowth endothelial cells and late outgrowth smooth muscle cells, respectively.
- 1 January 2016
- Published by Walter de Gruyter GmbH in BioNanoMaterials
- Vol. 17 (1-2)
Engineering of small diameter tubular compacted fibrin matrices
Fibrin is widely used in different approaches of tissue engineering. Nevertheless, poor biomechanical strength restricts its use namely in cardiovascular tissue engineering. We have recently developed a novel moulding technique for the generation of highly stable fibrin tubes. The purpose of this study was the application of this method to the generation of small calibre fibrin tubes for the generation of bioartificial vascular grafts with a diameter of 3 mm. Therefore, a fibrinogen preparation was separated from plasma by means of cryoprecipitation and applied to a high-speed rotating casting mould in a low concentration to achieve slow polymerization and thereby uniform distribution of the fibrinogen. Thus, uniformly moulded 10 cm long fibrin tubes with a diameter of 3 mm were generated from 145±22 mg fibrinogen precipitated from 50 mL plasma. Thickness of the wall (522±57 μm) and biomechanical strength (47.4±11.1 kPa) were equable over the whole length of the tubes. Burst strength was 367±49 mm Hg. Thus, the developed technique enables the generation of tubular fibrin segments with a high biomechanical stability and represents a powerful tool for the generation of custom-made bioartificial vascular grafts.
- 1 January 2016
- Published by Walter de Gruyter GmbH in BioNanoMaterials
- Vol. 17 (1-2)
Engineering of small diameter tubular compacted fibrin matrices
Fibrin is widely used in different approaches of tissue engineering. Nevertheless, poor biomechanical strength restricts its use namely in cardiovascular tissue engineering. We have recently developed a novel moulding technique for the generation of highly stable fibrin tubes. The purpose of this study was the application of this method to the generation of small calibre fibrin tubes for the generation of bioartificial vascular grafts with a diameter of 3 mm. Therefore, a fibrinogen preparation was separated from plasma by means of cryoprecipitation and applied to a high-speed rotating casting mould in a low concentration to achieve slow polymerization and thereby uniform distribution of the fibrinogen. Thus, uniformly moulded 10 cm long fibrin tubes with a diameter of 3 mm were generated from 145±22 mg fibrinogen precipitated from 50 mL plasma. Thickness of the wall (522±57 μm) and biomechanical strength (47.4±11.1 kPa) were equable over the whole length of the tubes. Burst strength was 367±49 mm Hg. Thus, the developed technique enables the generation of tubular fibrin segments with a high biomechanical stability and represents a powerful tool for the generation of custom-made bioartificial vascular grafts.
- 1 January 2016
- Published by Elsevier in Acta Biomaterialia
- Vol. 29, 21-32
Novel method for the generation of tissue-engineered vascular grafts based on a highly compacted fibrin matrix
- 1 January 2016
- Published by Elsevier in Acta Biomaterialia
- Vol. 29, 21-32
Novel method for the generation of tissue-engineered vascular grafts based on a highly compacted fibrin matrix
- 4 September 2015
- Published by Springer Nature in Zeitschrift für Herz-,Thorax- und Gefäßchirurgie
- Vol. 29 (5) , 342-348
Maßgeschneiderte autologe bioartifizielle Gefäßprothesen
- 4 September 2015
- Published by Springer Nature in Zeitschrift für Herz-,Thorax- und Gefäßchirurgie
- Vol. 29 (5) , 342-348
Maßgeschneiderte autologe bioartifizielle Gefäßprothesen
- 22 January 2013
- Published by Georg Thieme Verlag KG in Zentralblatt fur Chirurgie
- Vol. 138 (02) , 173-179
Development of Implantable Autologous Small-Calibre Vascular Grafts from Peripheral Blood Samples
Introduction: At present the generation of a small-calibre (≤ 5 mm) vascular replacement for artificial bypasses remains a challenge for tissue engineering. The biocompatibility of bioartificial vessel replacements is of decisive significance for function and depends on the materials used. A completely autologous vessel substitute must exhibit high biocompatibility and functionality. For this purpose we developed and optimised a technique for the engineering of an autologous bypass material from a fibrin scaffold and vascular cells isolated from the same sample of peripheral blood in a porcine model. Materials and Methods: Fibrinogen, late outgrowth endothelial and smooth muscle cells were isolated from peripheral blood samples (n = 14, 100 mL each). Fibroblasts were isolated from porcine aortic adventitial tissue (n = 4). Tubular seeded fibrin segments were obtained using an injection moulding technique with the simultaneous incorporation of the in vitro expanded cells into the fibrin matrix. The segments were cultivated under dynamic conditions with pulsatile perfusion in a bioreactor. Morphological and functional characterization was done. Results: Artificial vascular segments with a length of 150 mm were reproducibly obtained with a hierarchical arrangement of incorporated cells similar to the structure of the vascular wall. By additional seeding of fibroblasts, suturable segments with biomechanical properties suitable for implantation into the arterial system were obtained. Conclusions: Implantable bioartificial vascular grafts can be generated from blood. After cultivation under dynamic conditions the vascular segments possess a structure similar to that of the vascular wall and exhibit biomechanical properties sufficient for implantation as arterial substitutes. Einleitung: Die Generierung eines kleinlumigen Gefäßersatzes bleibt eine der großen Herausforderungen des Tissue Engineering. Die Biokompatibilität eines bioartifiziellen Gefäßersatzes ist dabei von entscheidender Bedeutung für seine Funktionalität und ist abhängig von den verwendeten Materialien. Ein vollständig autologer Gefäßersatz lässt eine hohe Biokompatibilität und Funktionalität erwarten. Dazu entwickelten wir eine Methode mit der in einem autologen Ansatz im Tiermodell (Schwein) aus Blut auf dem Boden einer Fibrinmatrix und zirkulierenden vaskulären Zellen ein Gefäßersatz konstruiert werden kann. Materialien und Methoden: Fibrinogen, late outgrowth endothelial und smooth muscle cells wurden jeweils aus der gleichen Menge peripheren Blutes isoliert (n = 14, je 100 ml). Fibroblasten wurden aus der Adventitia porciner Aorten (n = 4) isoliert. Unter Verwendung einer „injection moulding technique“ wurden unter gleichzeitiger Ansiedlung der Zellen in der Matrix tubuläre Fibrinsegmente generiert. Die Segmente wurden unter dynamischen Bedingungen mit pulsatiler Perfusion in einem Bioreaktor kultiviert und anschließend morphologisch und funktionell charakterisiert. Ergebnisse: Bioartifizielle Gefäßsegmente mit einer Länge von 150 mm wurden reproduzierbar konstruiert mit einer hierarchischen Anordnung der angesiedelten Zellen entsprechend dem Aufbau einer Gefäßwand. Durch die zusätzliche Besiedlung mit Fibroblasten wurden nahtfähige Segmente mit biomechanischen Eigenschaften generiert, die für die Implantation in das arterielle System geeignet sind. Schlussfolgerung: Aus Blut können implantierbare bioartifizielle Gefäßersatzstücke generiert werden. Nach Kultivierung unter dynamischen Bedingungen weisen die Gefäßsegmente einen Aufbau auf, der dem einer Gefäßwand ähnelt und mechanische Eigenschaften, die für die Implantation in das arterielle Gefäßsystem ausreichen.
- 22 January 2013
- Published by Georg Thieme Verlag KG in Zentralblatt fur Chirurgie
- Vol. 138 (02) , 173-179
Development of Implantable Autologous Small-Calibre Vascular Grafts from Peripheral Blood Samples
Introduction: At present the generation of a small-calibre (≤ 5 mm) vascular replacement for artificial bypasses remains a challenge for tissue engineering. The biocompatibility of bioartificial vessel replacements is of decisive significance for function and depends on the materials used. A completely autologous vessel substitute must exhibit high biocompatibility and functionality. For this purpose we developed and optimised a technique for the engineering of an autologous bypass material from a fibrin scaffold and vascular cells isolated from the same sample of peripheral blood in a porcine model. Materials and Methods: Fibrinogen, late outgrowth endothelial and smooth muscle cells were isolated from peripheral blood samples (n = 14, 100 mL each). Fibroblasts were isolated from porcine aortic adventitial tissue (n = 4). Tubular seeded fibrin segments were obtained using an injection moulding technique with the simultaneous incorporation of the in vitro expanded cells into the fibrin matrix. The segments were cultivated under dynamic conditions with pulsatile perfusion in a bioreactor. Morphological and functional characterization was done. Results: Artificial vascular segments with a length of 150 mm were reproducibly obtained with a hierarchical arrangement of incorporated cells similar to the structure of the vascular wall. By additional seeding of fibroblasts, suturable segments with biomechanical properties suitable for implantation into the arterial system were obtained. Conclusions: Implantable bioartificial vascular grafts can be generated from blood. After cultivation under dynamic conditions the vascular segments possess a structure similar to that of the vascular wall and exhibit biomechanical properties sufficient for implantation as arterial substitutes. Einleitung: Die Generierung eines kleinlumigen Gefäßersatzes bleibt eine der großen Herausforderungen des Tissue Engineering. Die Biokompatibilität eines bioartifiziellen Gefäßersatzes ist dabei von entscheidender Bedeutung für seine Funktionalität und ist abhängig von den verwendeten Materialien. Ein vollständig autologer Gefäßersatz lässt eine hohe Biokompatibilität und Funktionalität erwarten. Dazu entwickelten wir eine Methode mit der in einem autologen Ansatz im Tiermodell (Schwein) aus Blut auf dem Boden einer Fibrinmatrix und zirkulierenden vaskulären Zellen ein Gefäßersatz konstruiert werden kann. Materialien und Methoden: Fibrinogen, late outgrowth endothelial und smooth muscle cells wurden jeweils aus der gleichen Menge peripheren Blutes isoliert (n = 14, je 100 ml). Fibroblasten wurden aus der Adventitia porciner Aorten (n = 4) isoliert. Unter Verwendung einer „injection moulding technique“ wurden unter gleichzeitiger Ansiedlung der Zellen in der Matrix tubuläre Fibrinsegmente generiert. Die Segmente wurden unter dynamischen Bedingungen mit pulsatiler Perfusion in einem Bioreaktor kultiviert und anschließend morphologisch und funktionell charakterisiert. Ergebnisse: Bioartifizielle Gefäßsegmente mit einer Länge von 150 mm wurden reproduzierbar konstruiert mit einer hierarchischen Anordnung der angesiedelten Zellen entsprechend dem Aufbau einer Gefäßwand. Durch die zusätzliche Besiedlung mit Fibroblasten wurden nahtfähige Segmente mit biomechanischen Eigenschaften generiert, die für die Implantation in das arterielle System geeignet sind. Schlussfolgerung: Aus Blut können implantierbare bioartifizielle Gefäßersatzstücke generiert werden. Nach Kultivierung unter dynamischen Bedingungen weisen die Gefäßsegmente einen Aufbau auf, der dem einer Gefäßwand ähnelt und mechanische Eigenschaften, die für die Implantation in das arterielle Gefäßsystem ausreichen.