Emre Toker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Emre Toker has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Ahmet Yilmaz Coban
Akdeniz Universitesi
1 shared publication - Cagri Sakalar
Antimikrop Ar-Ge ve Biyosidal Analiz Merkezi , Nasuh Akar Mah. Süleyman Hacıabdullahoğlu Cad. No: 37/1, Çankaya, Ankara 06520 , Turkey
1 shared publication - Deniz Karaçaylı
Akdeniz University Biomedical Optics Research Unit, Department of Biophysics, Faculty of Medicine Antalya 07070 , Turkey
1 shared publication - Murat Canpolat
Department of Biophysics, Medical Faculty, Akdeniz University, Antalya 07070, Türkiye
1 shared publication - Serhat Bozkurt
Antalya Belek University Pharmancy Services Program, Vocational School Antalya 07525 , Turkey
1 shared publication
Latest Publications
- 4 December 2023
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 16 (2) , 1-22
Thermal Inactivation of Airborne SARS-CoV-2 by an Electric Fan Heater in Winter and Defining Conditions to Ensure That All the Air Passes Through the Fan
The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is spread, especially in closed environments, by airborne transmission. The study aims to assess the thermal inactivation of airborne SARS-CoV-2 in a 30 m3 test room as a function of outlet temperature, airflow rate, and operating time of an electric heater, then define a condition to ensure that all air in the room passes through the electric heater. Aerosolized SARS-CoV-2 was delivered to the test room at an ambient temperature of 20 °C and 40% humidity. Two electric heaters with different powers and airflow rates were operated respectively in the test room to compare their efficiencies in the inactivation of airborne SARS-CoV-2. The first and second electric heaters had power, airflow rates, and outlet temperatures of 1.5 kW, 44 m3/h, 220 °C, and 3 kW, 324 m3/h, and 150 °C, respectively. A fan drew the outside air into the heater. In the first experiment, a 1.5 kW electric heater was operated in the test room for 80 min. In the second experiment, a 3 kW electric heater was used in the test room for 75 min. Airborne SARS-CoV-2 in the test room was inactivated by 99.00% and 99.96% in the first and second experiments, respectively. A condition is defined to ensure that all the air in the room passes at least once through the electric heater fan.
- 4 December 2023
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 16 (2) , 1-22
Thermal Inactivation of Airborne SARS-CoV-2 by an Electric Fan Heater in Winter and Defining Conditions to Ensure That All the Air Passes Through the Fan
The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is spread, especially in closed environments, by airborne transmission. The study aims to assess the thermal inactivation of airborne SARS-CoV-2 in a 30 m3 test room as a function of outlet temperature, airflow rate, and operating time of an electric heater, then define a condition to ensure that all air in the room passes through the electric heater. Aerosolized SARS-CoV-2 was delivered to the test room at an ambient temperature of 20 °C and 40% humidity. Two electric heaters with different powers and airflow rates were operated respectively in the test room to compare their efficiencies in the inactivation of airborne SARS-CoV-2. The first and second electric heaters had power, airflow rates, and outlet temperatures of 1.5 kW, 44 m3/h, 220 °C, and 3 kW, 324 m3/h, and 150 °C, respectively. A fan drew the outside air into the heater. In the first experiment, a 1.5 kW electric heater was operated in the test room for 80 min. In the second experiment, a 3 kW electric heater was used in the test room for 75 min. Airborne SARS-CoV-2 in the test room was inactivated by 99.00% and 99.96% in the first and second experiments, respectively. A condition is defined to ensure that all the air in the room passes at least once through the electric heater fan.