Carmen Fabbricatore
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Carmen Fabbricatore has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Natale Arcuri
Department of Mechanical, Energy and Management Engineering (DIMEG), University of Calabria, 87036 Rende, Italy
2 shared publications - Cristina Carpino
Department of Mechanical, Energy and Management Engineering, University of Calabria, 87036 Rende, Cosenza, Italy
1 shared publication - Daniela Cirone
Mechanical, Energy and Management Engineering Department, University of Calabria, 87036 Rende, Italy
1 shared publication - Francesco Barreca
Department of Agraria, “Mediterranean” University of Reggio Calabria, 89123 Reggio Calabria, Italy
1 shared publication - Francesco Nicoletti
Mechanical, Energy and Management Engineering Department, University of Calabria, 87036 Rende, Italy
1 shared publication - Piero Bevilacqua
Department of Mechanical, Energy and Management Engineering, University of Calabria, Arcavacata di Rende, 87036 Cosenza, Italy
1 shared publication
Latest Publications
- Open Access
A Spectroradiometric Analysis of Alterations in Spectral Distribution and Their Impact on UV Index Estimation for Solar Resource Assessment
The accurate estimation of the instantaneous UV Index (UVI) is critical for public health, yet it is often attempted using broadband pyranometers (measuring Global Horizontal Irradiance GHI) or photometers (measuring Lux). This approach is known to be unreliable, particularly under the complex radiative conditions induced by clouds. However, the physical mechanisms driving this failure, specifically the changes in the spectral quality of sunlight, are not fully quantified. This study utilizes a high-resolution spectroradiometer and pyranometer at a Mediterranean site (Rende, Italy), analyzing instantaneous UVI, GHI and a set of derived analytical metrics: the Erythemal Efficacy, the UV Spectral Quality Ratio and the Clearness Index. The core metric of the paper is the Erythemal Efficacy, designed to quantify the “spectral quality” or “biological hazard” per unit of total energy. It is defined as the ratio of the instantaneous UV Index to the instantaneous GHI measured by the pyranometer. The analysis confirms a decoupling between instantaneous UVI and broadband GHI, exhibiting a wide, non-functional scatter. The paper shows that this failure is caused by the high variability of the Erythemal Efficacy, which is not a constant. Its variability is shown to be linearly governed by the internal Ultraviolet A to Ultraviolet B (UVA/UVB) spectral ratio. Most critically, the Erythemal Efficacy was found to follow a counter-intuitive trend, increasing significantly as the Clearness Index decreases. The common assumption of clouds as spectrally “grey” attenuators is flawed. Clouds act as selective filters, attenuating the GHI, dominated by Visible to Near-Infrared (VIS/NIR), more severely than the UVI. This increases the relative biological hazard of the light that penetrates thick cloud cover. This study provides a physical explanation for the failure of broadband proxies and demonstrates that instantaneous GHI or Lux-based UVI alerts are fundamentally unreliable, as they fail to capture the critical variability of spectral quality.
Open AccessA Spectroradiometric Analysis of Alterations in Spectral Distribution and Their Impact on UV Index Estimation for Solar Resource Assessment
The accurate estimation of the instantaneous UV Index (UVI) is critical for public health, yet it is often attempted using broadband pyranometers (measuring Global Horizontal Irradiance GHI) or photometers (measuring Lux). This approach is known to be unreliable, particularly under the complex radiative conditions induced by clouds. However, the physical mechanisms driving this failure, specifically the changes in the spectral quality of sunlight, are not fully quantified. This study utilizes a high-resolution spectroradiometer and pyranometer at a Mediterranean site (Rende, Italy), analyzing instantaneous UVI, GHI and a set of derived analytical metrics: the Erythemal Efficacy, the UV Spectral Quality Ratio and the Clearness Index. The core metric of the paper is the Erythemal Efficacy, designed to quantify the “spectral quality” or “biological hazard” per unit of total energy. It is defined as the ratio of the instantaneous UV Index to the instantaneous GHI measured by the pyranometer. The analysis confirms a decoupling between instantaneous UVI and broadband GHI, exhibiting a wide, non-functional scatter. The paper shows that this failure is caused by the high variability of the Erythemal Efficacy, which is not a constant. Its variability is shown to be linearly governed by the internal Ultraviolet A to Ultraviolet B (UVA/UVB) spectral ratio. Most critically, the Erythemal Efficacy was found to follow a counter-intuitive trend, increasing significantly as the Clearness Index decreases. The common assumption of clouds as spectrally “grey” attenuators is flawed. Clouds act as selective filters, attenuating the GHI, dominated by Visible to Near-Infrared (VIS/NIR), more severely than the UVI. This increases the relative biological hazard of the light that penetrates thick cloud cover. This study provides a physical explanation for the failure of broadband proxies and demonstrates that instantaneous GHI or Lux-based UVI alerts are fundamentally unreliable, as they fail to capture the critical variability of spectral quality.
- Open Access
Configuration Optimization for Sustainable Temporary Houses Employing BIM Procedure
Building information modeling (BIM) is a process for managing the construction information model. The possibility of managing very complex construction orders using information processes has made the work of designers both easier and more productive. In this research, a new process of “assisted design” was implemented for self-assembling temporary houses with high environmental sustainability. The developed procedure allows for the supporting of a nonexpert user in the configuration of housing modules, using the base elements, and assisting them until the energy verification process based on the place of installation. Furthermore, a lifecycle assessment of emissions is made available. This is the result of the interoperability of software enabled by using BIM logic. The proposed work contributes to enriching the range of technical solutions developed to meet the demand for temporary buildings, providing a valid support tool in the design phase, especially when it needs to be completed within a short timeframe. This study introduces a smart configuration procedure that combines aspects of project automation and flexibility with energy efficiency and environmental sustainability needs required for the green transition of building stock.
Open AccessConfiguration Optimization for Sustainable Temporary Houses Employing BIM Procedure
Building information modeling (BIM) is a process for managing the construction information model. The possibility of managing very complex construction orders using information processes has made the work of designers both easier and more productive. In this research, a new process of “assisted design” was implemented for self-assembling temporary houses with high environmental sustainability. The developed procedure allows for the supporting of a nonexpert user in the configuration of housing modules, using the base elements, and assisting them until the energy verification process based on the place of installation. Furthermore, a lifecycle assessment of emissions is made available. This is the result of the interoperability of software enabled by using BIM logic. The proposed work contributes to enriching the range of technical solutions developed to meet the demand for temporary buildings, providing a valid support tool in the design phase, especially when it needs to be completed within a short timeframe. This study introduces a smart configuration procedure that combines aspects of project automation and flexibility with energy efficiency and environmental sustainability needs required for the green transition of building stock.