Matthew L. Strader
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Matthew L. Strader has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Alex J. Shearer
Department of Chemistry, University of California at Berkeley, Berkeley, California, United States
1 shared publication- Angel T. Garcia-Esparza
Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, USA
1 shared publication - Aram Yang
Department of Pediatrics, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea
1 shared publication Benjamin D. Matson
SLAC National Accelerator Laboratory 1 , Menlo Park, California 94025, USA
1 shared publication- Benjamin W. Caplins
National Institute of Standards and Technology, Applied Chemicals and Materials Division, Boulder, CO, 80305, USA
1 shared publication Charles B. Harris
Department of Chemistry, University of California at Berkeley, Berkeley, California, United States
1 shared publication
Latest Publications
- Open Access
- 1 September 2023
- Published by AIP Publishing in Structural Dynamics
- Vol. 10 (5) , 054304
Solution phase high repetition rate laser pump x-ray probe picosecond hard x-ray spectroscopy at the Stanford Synchrotron Radiation Lightsource
We present a dedicated end-station for solution phase high repetition rate (MHz) picosecond hard x-ray spectroscopy at beamline 15-2 of the Stanford Synchrotron Radiation Lightsource. A high-power ultrafast ytterbium-doped fiber laser is used to photoexcite the samples at a repetition rate of 640 kHz, while the data acquisition operates at the 1.28 MHz repetition rate of the storage ring recording data in an alternating on-off mode. The time-resolved x-ray measurements are enabled via gating the x-ray detectors with the 20 mA/70 ps camshaft bunch of SPEAR3, a mode available during the routine operations of the Stanford Synchrotron Radiation Lightsource. As a benchmark study, aiming to demonstrate the advantageous capabilities of this end-station, we have conducted picosecond Fe K-edge x-ray absorption spectroscopy on aqueous [FeII(phen)3]2+, a prototypical spin crossover complex that undergoes light-induced excited spin state trapping forming an electronic excited state with a 0.6–0.7 ns lifetime. In addition, we report transient Fe Kβ main line and valence-to-core x-ray emission spectra, showing a unique detection sensitivity and an excellent agreement with model spectra and density functional theory calculations, respectively. Notably, the achieved signal-to-noise ratio, the overall performance, and the routine availability of the developed end-station have enabled a systematic time-resolved science program using the monochromatic beam at the Stanford Synchrotron Radiation Lightsource.
- 1 September 2023
- Published by AIP Publishing in Structural Dynamics
- Vol. 10 (5) , 054304
Open AccessSolution phase high repetition rate laser pump x-ray probe picosecond hard x-ray spectroscopy at the Stanford Synchrotron Radiation Lightsource
We present a dedicated end-station for solution phase high repetition rate (MHz) picosecond hard x-ray spectroscopy at beamline 15-2 of the Stanford Synchrotron Radiation Lightsource. A high-power ultrafast ytterbium-doped fiber laser is used to photoexcite the samples at a repetition rate of 640 kHz, while the data acquisition operates at the 1.28 MHz repetition rate of the storage ring recording data in an alternating on-off mode. The time-resolved x-ray measurements are enabled via gating the x-ray detectors with the 20 mA/70 ps camshaft bunch of SPEAR3, a mode available during the routine operations of the Stanford Synchrotron Radiation Lightsource. As a benchmark study, aiming to demonstrate the advantageous capabilities of this end-station, we have conducted picosecond Fe K-edge x-ray absorption spectroscopy on aqueous [FeII(phen)3]2+, a prototypical spin crossover complex that undergoes light-induced excited spin state trapping forming an electronic excited state with a 0.6–0.7 ns lifetime. In addition, we report transient Fe Kβ main line and valence-to-core x-ray emission spectra, showing a unique detection sensitivity and an excellent agreement with model spectra and density functional theory calculations, respectively. Notably, the achieved signal-to-noise ratio, the overall performance, and the routine availability of the developed end-station have enabled a systematic time-resolved science program using the monochromatic beam at the Stanford Synchrotron Radiation Lightsource.
- 21 June 2013
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 135 (29) , 10646-10653
Femtosecond Electron Solvation at the Ionic Liquid/Metal Electrode Interface
Electron solvation is examined at the interface of a room temperature ionic liquid (RTIL) and an Ag(111) electrode. Femtosecond two-photon photoemission spectroscopy is used to inject an electron into an ultrathin film of RTIL 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide ([Bmpyr]+[NTf2]−). While much of current literature highlights slower nanosecond solvation mechanisms in bulk ionic liquids, we observe only a femtosecond response, supporting morphology dependent and interface specific electron solvation mechanisms. The injected excess electron is found to reside in an electron affinity level residing near the metal surface. Population of this state decays back to the metal with a time constant of 400 ± 150 fs. Electron solvation is measured as a dynamic decrease in the energy with a time constant of 350 ± 150 fs. We observe two distinct temperature regimes, with a critical temperature near 250 K. The low temperature regime is characterized by a higher work function of 4.41 eV, while the high temperature regime is characterized by a lower work function of 4.19 eV. The total reorganizational energy of solvation changes above and below the critical temperature. In the high temperature regime, the electron affinity level solvates by 540 meV at 350 K, and below the critical temperature, solvation decreases to 200 meV at 130 K. This study will provide valuable insight to interface specific solvation of room temperature ionic liquids.
- 21 June 2013
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 135 (29) , 10646-10653
Femtosecond Electron Solvation at the Ionic Liquid/Metal Electrode Interface
Electron solvation is examined at the interface of a room temperature ionic liquid (RTIL) and an Ag(111) electrode. Femtosecond two-photon photoemission spectroscopy is used to inject an electron into an ultrathin film of RTIL 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide ([Bmpyr]+[NTf2]−). While much of current literature highlights slower nanosecond solvation mechanisms in bulk ionic liquids, we observe only a femtosecond response, supporting morphology dependent and interface specific electron solvation mechanisms. The injected excess electron is found to reside in an electron affinity level residing near the metal surface. Population of this state decays back to the metal with a time constant of 400 ± 150 fs. Electron solvation is measured as a dynamic decrease in the energy with a time constant of 350 ± 150 fs. We observe two distinct temperature regimes, with a critical temperature near 250 K. The low temperature regime is characterized by a higher work function of 4.41 eV, while the high temperature regime is characterized by a lower work function of 4.19 eV. The total reorganizational energy of solvation changes above and below the critical temperature. In the high temperature regime, the electron affinity level solvates by 540 meV at 350 K, and below the critical temperature, solvation decreases to 200 meV at 130 K. This study will provide valuable insight to interface specific solvation of room temperature ionic liquids.