Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Naokata Kutsuzawa has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Double-Layered Microphysiological System Made of Polyethylene Terephthalate with Trans-Epithelial Electrical Resistance Measurement Function for Uniform Detection Sensitivity

    by Naokata Kutsuzawa, Hiroko Nakamura, Laner Chen, Ryota Fujioka, Shuntaro Mori, Noriyuki Nakatani, Takahiro Yoshioka, Hiroshi Kimura

    Microphysiological systems (MPSs) have emerged as alternatives to animal testing in drug development, following the FDA Modernization Act 2.0. Double-layer channel-type MPS chips with porous membranes are widely used for modeling various organs, including the intestines, blood–brain barrier, renal tubules, and lungs. However, these chips faced challenges owing to optical interference caused by light scattering from the porous membrane, which hinders cell observation. Trans-epithelial electrical resistance (TEER) measurement offers a non-invasive method for assessing barrier integrity in these chips. However, existing electrode-integrated MPS chips for TEER measurement have non-uniform current densities, leading to compromised measurement accuracy. Additionally, chips made from polydimethylsiloxane have been associated with drug absorption issues. This study developed an electrode-integrated MPS chip for TEER measurement with a uniform current distribution and minimal drug absorption. Through a finite element method simulation, electrode patterns were optimized and incorporated into a polyethylene terephthalate (PET)-based chip. The device was fabricated by laminating PET films, porous membranes, and patterned gold electrodes. The chip’s performance was evaluated using a perfused Caco-2 intestinal model. TEER levels increased and peaked on day 5 when cells formed a monolayer, and then they decreased with the development of villi-like structures. Concurrently, capacitance increased, indicating microvilli formation. Exposure to staurosporine resulted in a dose-dependent reduction in TEER, which was validated by immunostaining, indicating a disruption of the tight junction. This study presents a TEER measurement MPS platform with a uniform current density and reduced drug absorption, thereby enhancing TEER measurement reliability. This system effectively monitors barrier integrity and drug responses, demonstrating its potential for non-animal drug-testing applications.


  • Open Access

    Double-Layered Microphysiological System Made of Polyethylene Terephthalate with Trans-Epithelial Electrical Resistance Measurement Function for Uniform Detection Sensitivity

    by Naokata Kutsuzawa, Hiroko Nakamura, Laner Chen, Ryota Fujioka, Shuntaro Mori, Noriyuki Nakatani, Takahiro Yoshioka, Hiroshi Kimura

    Microphysiological systems (MPS) have emerged as alternatives to animal testing in drug development, following the FDA Modernization Act 2.0. Double-layer channel-type MPS chips with porous membranes are versatile for modeling various organs, including the intestines, blood-brain barrier, renal tubules, and lungs. However, these chips faced challenges owing to optical interference caused by light scattering from the porous membrane, which hinders cell observation. One non-invasive method for assessing barrier integrity in these chips is trans-epithelial electrical resistance (TEER) measurement. Existing electrode-integrated MPS chips for TEER measurement have non-uniform current densities, leading to compromised measurement accuracy. Additionally, chips made from polydimethylsiloxane have been associated with drug absorption issues. This study developed an electrode-integrated MPS chip for TEER measurement with uniform current distribution and minimal drug absorption. Through finite element method simulation, electrode patterns were optimized and incorporated into a polyethylene terephthalate (PET)-based chip. The device was fabricated by laminating PET films, porous membranes, and patterned gold electrodes. The chip’s performance was evaluated using a perfused Caco-2 intestinal model. TEER levels peaked on day 5 when cells formed a monolayer, then decreased as villi-like structures developed. Capacitance increased, indicating microvilli formation. Exposure to staurosporine resulted in a dose-dependent reduction in TEER, which was validated by immunostaining indicating tight junction disruption. This study presents a TEER measurement MPS platform with uniform current density and reduced drug absorption, thereby enhancing TEER measurement reliability. This system effectively monitors barrier integrity and drug responses, demonstrating its potential for non-animal drug-testing applications.


  • Open Access

    Evaluation of Perfusion Cell Culture Conditions in a Double-Layered Microphysiological System Using AI-Assisted Morphological Analysis

    by Naokata Kutsuzawa, Tomomi Goto, Hiroko Nakamura, Miwa Maeda, Masaki Kinehara, Junko Sakagami, Hiroshi Kimura

    In recent years, microphysiological systems (MPS) using microfluidic technology as a new in vitro experimental system have shown promise as an alternative to animal experiments in the development of drugs, especially in the field of drug discovery, and some reports have indicated that MPS experiments have the potential to be a valuable tool to obtain outcomes comparable to those of animal experiments. We have commercialized the Fluid3D-X®, a double-layer microfluidic chip made of polyethylene terephthalate (PET), under the Japan Agency for Medical Research and Development (AMED) MPS development research project and have applied it to various organ models. When intestinal epithelial cells, Caco-2, were cultured using Fluid3D-X® and a peristaltic pump, villi-like structures were formed in the microchannels. Still, the degree of formation differed between the upstream and downstream sides. To examine the consideration points regarding the effects of the nutrient and oxygen supply by the chip material and the medium perfusion rate and direction on cells in the widely used double-layer microfluidic chip and to demonstrate the usefulness of a new imaging evaluation method using artificial intelligence technology as an assistive tool for the morphological evaluation of cells, the cell morphology in the channels was quantified and evaluated using the Nikon NIS.ai and microscopic observation. Villi-like structures were predominant upstream of the top channel, independent of the medium perfusion on the bottom channel, and those structures downstream developed with an increased flow rate. Additionally, compared to the Fluid3D-X®, the chip made of PDMS showed almost uniform villi-like sterilization in the channel. The result indicates that the environment within the microchannels differs because the amount of nutrients and oxygen supply varies depending on the medium’s perfusion and the material of the chips. As the amount of oxygen and nutrients required by different cell types differs, it is necessary to study the optimization of culture conditions according to the characteristics of the cells handled. It was also demonstrated that the AI-based image analysis method is helpful as a quantification method for the differences in cell morphology in the microchannel observed under a microscope.


  • Open Access

    Evaluation of Perfusion Cell Culture Conditions in a Double-Layered Microphysiological System Using AI-Based Morphological Analysis

    by Naokata Kutsuzawa, Tomomi Goto, Hiroko Nakamura, Miwa Maeda, Masaki Kinehara, Junko Sakagami, Hiroshi Kimura

    Background: In recent years, microphysiological systems (MPS) using microfluidic technology as a new in vitro experimental system have shown promise as an alternative to animal experiments in the development of drugs, especially in the field of drug discovery, and reports have been published that MPS experiments have replaced animal experiments. We have commercialized the Fluid3D-X®, a double-layer microfluidic chip made of polyethylene terephthalate (PET), under the Japan Agency for Medical Research and Development (AMED) MPS development research project and have applied it to various organ models. When Caco-2 cells were cultured using Fluid3D-X® and a peristaltic pump, villi-like structures were formed in the microchannels, but the degree of formation differed between the upstream and downstream sides. To examine consideration points regarding the effects of the nutrient and oxygen supply by the chip material and medium flow on cells in the widely used double-layer microfluidic chip, and demonstrate the usefulness of a new imaging evaluation method using artificial intelligence technology for the morphological evaluation of cells. Methods: The following studies were conducted. 1. Perfusion direction: The medium was perfused at a normal flow rate (20 µL/min) using Fluid3D-X® and a peristaltic pump in opposite directions within the top and bottom channels and in the same direction initially, then reversed in both layers. 2. Perfusion speed: Incubated at normal and doubled (40 µL/min) flow rates using Fluid3D-X® and a peristaltic pump. 3. Materials: Incubated at the normal flow rate with Fluid3D-X® and polydimethylsiloxane (PDMS) chip, which has the same microchannel design as Fluid3D-X® but is made of PDMS. Results: Cell morphology in the channels was quantified and evaluated using Nikon NIS.ai in addition to microscopic observation. Villi-like structures were predominant upstream of the top channel, independent of perfusion on the bottom channel, and those structures downstream increased with doubled speed. Additionally, compared to the Fluid3D-X, the chip made of PDMS showed almost uniform villi-like sterilization in the channel. Conclusion: As the amount of oxygen and nutrients required by different cell types differs, it is necessary to study the optimization of culture conditions according to the characteristics of the cells handled.


  • Effect of mechanosensor channel Piezo1 on alveolar epithelial barrier function and wound healing

    by Naokata Kutsuzawa, Yoko Ito, Shizuko Kagawa, Hiroto Takiguchi, Hiroshi Kimura, Koichiro Asano

    Background: Piezo1, a mechanosensitive and non-selective cation channel, performs an essential function in several physiological processes. However, little is known about their effects on the barrier function and wound-healing of the alveolar epithelium. Aims and Objectives: To investigate the effect of Piezo1 on the pathogenesis of acute lung injury, especially alveolar epithelial barrier dysfunction and the wound healing. Methods: Rat type II alveolar epithelial cells were isolated from 5-6 week-old male Sprague Dawley rats. To estimate barrier function, the cells were seeded onto collagen-coated transwells and transdifferentiated into type I-like cells to make confluent monolayer. The monolayer was stimulated with tumor necrosis factor alpha (TNFα), dexamethasone, and grammostola spatulata mechanotoxin 4 (GsMTx4), a Piezo1 receptor antagonist. Barrier function was evaluated by trans-epithelial electrical resistance (TEER). Areas of wound made by the scratching of type I-like cells monolayer with pipet tips were measured at 0 and 16 hours after stimulation. Results: GsMTx4 (10 μg/mL) did not affect barrier function in intact or damaged alveolar epithelial cell monolayer in the absence or presence of TNFa (10 ng/mL, p=0.16 and p=0.16, respectively). On the other hand, GsMTx4 accelerated repair of scratch wounds (p=0.02). Dexamethasone (100 nM) delayed wound repair, which was significantly recovered by GsMTx4 (p=0.009). Conclusion: Piezo1 has no effects on alveolar epithelial barrier function, whereas its inhibition improves dexamethasone-induced delay of alveolar epithelium wound-healing.

  • Dexamethasone restores TNFα-induced epithelial barrier dysfunction in primary rat alveolar epithelial cells

    by Naokata Kutsuzawa, Yoko Ito, Shizuko Kagawa, Hiroto Takiguchi, Koichiro Asano

    Background: Tumor necrosis factor-alpha (TNFα) disrupts the alveolar barriers in lung injuries due to various causes, for which glucocorticoids(GCs) are often used for the treatment. However, the involvement of GCs in the restoration of alveolar epithelial(AE) barrier dysfunction remains unclear. Aims and Objectives: To identify the effect of dexamethasone (Dex) on TNFα-induced AE barrier dysfunction. Methods: Rat type II AE cells isolated from 5–6-week old male Sprague Dawley rats were seeded onto collagen-coated transwells and transdifferentiated into type I-like cells to make confluent monolayer. It was stimulated with TNFα and/or Dex. Barrier function and cytotoxicity were evaluated by trans-epithelial electrical resistance (TER) and LDH assay, respectively. The expressions of tight junction(TJ)-related proteins were analyzed by qPCR, immunoblot and immunocytochemistry. Results: TNFα decreased TER, increased LDH release, and reduced the levels of a TJ protein, zonula occledens-1 (ZO-1), at 48 h of exposure (p<0.05). Dex added at 24 h of TNFα exposure restored the decline in TER at 48 h (p<0.01), which was suppressed in the presence of RU486, a glucocorticoid receptor (GR) antagonist (p<0.05). Dex did not reduce TNFα-induced cytotoxicity or ZO-1 protein levels, but augmented the ZO-1 immunoreactivity at intercellular junction sites. Dex significantly reduced the levels of myosin light chain kinase (MLCK) mRNA and phosphorylated myosin light chain (pMLC) protein, which can regulate ZO-1 distribution and stabilization at TJs. Conclusion: Dex resorted TNFα-induced AE barrier dysfunction by redistributing ZO-1 into intercellular junction sites probably via GR/MLCK/pMLC axis.