Max Moebus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Max Moebus has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Christian Holz
Department of Computer Science, ETH Zurich, Zurich, Switzerland
7 shared publications - Berken Utku Demirel
Department of Computer Science, ETH Zurich, Zurich, Switzerland
2 shared publications - Liliana Barrios
Department of Computer Science, ETH Zurich, Zurich, Switzerland
2 shared publications - Marc Hilty
Neuroimmunology and Multiple Sclerosis Research Section, Department of Neurology, University Hospital Zurich, 8091 Zurich, Switzerland
2 shared publications - Pietro Oldrati
Cellerys AG, Wagistrasse 21, Schlieren, Switzerland
2 shared publications - Adnan Harun Dogan
METU
1 shared publication
Latest Publications
- 7 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Visualization and Computer Graphics
- Vol. 31 (5) , 2525-2534
Beyond Subjectivity: Continuous Cybersickness Detection Using EEG-based Multitaper Spectrum Estimation
Virtual reality (VR) presents immersive opportunities across many applications, yet the inherent risk of developing cybersickness during interaction can severely reduce enjoyment and platform adoption. Cybersickness is marked by symptoms such as dizziness and nausea, which previous work primarily assessed via subjective post-immersion questionnaires and motion-restricted controlled setups. In this paper, we investigate the dynamic nature of cybersickness while users experience and freely interact in VR. We propose a novel method to continuously identify and quantitatively gauge cybersickness levels from users' passively monitored electroencephalography (EEG) and head motion signals. Our method estimates multitaper spectrums from EEG, integrating specialized EEG processing techniques to counter motion artifacts, and, thus, tracks cybersickness levels in real-time. Unlike previous approaches, our method requires no user-specific calibration or personalization for detecting cybersickness. Our work addresses the considerable challenge of reproducibility and subjectivity in cybersickness research. In addition to our method's implementation, we release our dataset of 16 participants and approximately 2 hours of total recordings to spur future work in this domain. Source code: https://github.com/eth-siplab/EEG_Cybersickness_Estimation_VR-Beyond_Subjectivity.
- 7 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Visualization and Computer Graphics
- Vol. 31 (5) , 2525-2534
Beyond Subjectivity: Continuous Cybersickness Detection Using EEG-based Multitaper Spectrum Estimation
Virtual reality (VR) presents immersive opportunities across many applications, yet the inherent risk of developing cybersickness during interaction can severely reduce enjoyment and platform adoption. Cybersickness is marked by symptoms such as dizziness and nausea, which previous work primarily assessed via subjective post-immersion questionnaires and motion-restricted controlled setups. In this paper, we investigate the dynamic nature of cybersickness while users experience and freely interact in VR. We propose a novel method to continuously identify and quantitatively gauge cybersickness levels from users' passively monitored electroencephalography (EEG) and head motion signals. Our method estimates multitaper spectrums from EEG, integrating specialized EEG processing techniques to counter motion artifacts, and, thus, tracks cybersickness levels in real-time. Unlike previous approaches, our method requires no user-specific calibration or personalization for detecting cybersickness. Our work addresses the considerable challenge of reproducibility and subjectivity in cybersickness research. In addition to our method's implementation, we release our dataset of 16 participants and approximately 2 hours of total recordings to spur future work in this domain. Source code: https://github.com/eth-siplab/EEG_Cybersickness_Estimation_VR-Beyond_Subjectivity.
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (2) , 870-877
Nightbeat: Heart Rate Estimation From a Wrist-Worn Accelerometer During Sleep
Today's fitness bands and smartwatches typically track heart rates (HR) using optical sensors. Large behavioral studies such as the U.K. Biobank use activity trackers without such optical sensors and thus lack HR data, which could reveal valuable health trends for the wider population. In this paper, we present the first dataset of wrist-worn accelerometer recordings and electrocardiogram references in uncontrolled at-home settings to investigate the recent promise of IMU-only HR estimation via ballistocardiograms. Our recordings are from 42 patients during the night, totaling 310 hours. We also introduce a frequency-based method to extract HR via curve tracing from IMU recordings while rejecting motion artifacts. Using our dataset, we analyze existing baselines and show that our method achieves a mean absolute error of 0.88 bpm—76% better than previous approaches and the first to surpass established medical standards for heart rate monitors. Our results validate the potential of IMU-only HR estimation as a key indicator of cardiac activity in existing longitudinal studies to discover novel health insights. Our dataset, Nightbeat-DB, and our source code are available on GitHub: https://github.com/eth-siplab/Nightbeat .
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (2) , 870-877
Nightbeat: Heart Rate Estimation From a Wrist-Worn Accelerometer During Sleep
Today's fitness bands and smartwatches typically track heart rates (HR) using optical sensors. Large behavioral studies such as the U.K. Biobank use activity trackers without such optical sensors and thus lack HR data, which could reveal valuable health trends for the wider population. In this paper, we present the first dataset of wrist-worn accelerometer recordings and electrocardiogram references in uncontrolled at-home settings to investigate the recent promise of IMU-only HR estimation via ballistocardiograms. Our recordings are from 42 patients during the night, totaling 310 hours. We also introduce a frequency-based method to extract HR via curve tracing from IMU recordings while rejecting motion artifacts. Using our dataset, we analyze existing baselines and show that our method achieves a mean absolute error of 0.88 bpm—76% better than previous approaches and the first to surpass established medical standards for heart rate monitors. Our results validate the potential of IMU-only HR estimation as a key indicator of cardiac activity in existing longitudinal studies to discover novel health insights. Our dataset, Nightbeat-DB, and our source code are available on GitHub: https://github.com/eth-siplab/Nightbeat .
- Open Access
- 13 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 1-3
Demonstrating LLM-for-X: Application-agnostic Integration of Large Language Models to Support Writing Workflows
In this demonstration, we show LLM-for-X, a system-wide shortcut layer that connects any application to backend LLM support through a lightweight popup dialog. LLM-for-X provides users with quick and easy-to-use LLM assistance without context switching to support writing and reading tasks. We show the use of LLM-for-X across several applications, such as Microsoft Office, VSCode, and Adobe Acrobat, which our tool seamlessly connects to the backends of OpenAI ChatGPT and Google Gemini. We also demonstrate the use of our system inside web apps such as Overleaf.
- 13 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 1-3
Open AccessDemonstrating LLM-for-X: Application-agnostic Integration of Large Language Models to Support Writing Workflows
In this demonstration, we show LLM-for-X, a system-wide shortcut layer that connects any application to backend LLM support through a lightweight popup dialog. LLM-for-X provides users with quick and easy-to-use LLM assistance without context switching to support writing and reading tasks. We show the use of LLM-for-X across several applications, such as Microsoft Office, VSCode, and Adobe Acrobat, which our tool seamlessly connects to the backends of OpenAI ChatGPT and Google Gemini. We also demonstrate the use of our system inside web apps such as Overleaf.
- Open Access
- 21 August 2024
- Published by JMIR Publications Inc. in JMIR Neurotechnology
- Vol. 3 (1) , e48148
Assessing the Role of the Autonomic Nervous System as a Driver of Sleep Quality in Patients With Multiple Sclerosis: Observation Study
Background: Low sleep quality is a common symptom of multiple sclerosis (MS) and substantially decreases patients’ quality of life. The autonomic nervous system (ANS) is crucial to healthy sleep, and the transition from wake to sleep produces the largest shift in autonomic activity we experience every day. For patients with MS, the ANS is often impaired. The relationship between the ANS and perceived sleep quality in patients with MS remains elusive. Objective: In this study, we aim to quantify the impact of the ANS and MS on perceived sleep quality. Methods: We monitored 77 participants over 2 weeks using an arm-worn wearable sensor and a custom smartphone app. Besides recording daily perceived sleep quality, we continuously recorded participants’ heart rate (HR) and HR variability on a per-second basis, as well as stress, activity, and the weather (20,700 hours of sensor data). Results: During sleep, we found that reduced HR variability and increased motion led to lower perceived sleep quality in patients with MS (n=53) as well as the age- and gender-matched control group (n=24). An activated stress response (high sympathetic activity and low parasympathetic activity) while asleep resulted in lower perceived sleep quality. For patients with MS, an activated stress response while asleep reduced perceived sleep quality more heavily than in the control group. Similarly, the effect of increased stress levels throughout the day is particularly severe for patients with MS. For patients with MS, we found that stress correlated negatively with minimal observed HR while asleep and might even affect their daily routine. We found that patients with MS with more severe impairments generally recorded lower perceived sleep quality than patients with MS with less severe disease progression. Conclusions: For patients with MS, stress throughout the day and an activated stress response while asleep play a crucial role in determining sleep quality, whereas this is less important for healthy individuals. Besides ensuring an adequate sleep duration, patients with MS might thus work to reduce stressors, which seem to have a particularly negative effect on sleep quality. Generally, however, sleep quality decreases with MS disease progression.
- 21 August 2024
- Published by JMIR Publications Inc. in JMIR Neurotechnology
- Vol. 3 (1) , e48148
Open AccessAssessing the Role of the Autonomic Nervous System as a Driver of Sleep Quality in Patients With Multiple Sclerosis: Observation Study
Background: Low sleep quality is a common symptom of multiple sclerosis (MS) and substantially decreases patients’ quality of life. The autonomic nervous system (ANS) is crucial to healthy sleep, and the transition from wake to sleep produces the largest shift in autonomic activity we experience every day. For patients with MS, the ANS is often impaired. The relationship between the ANS and perceived sleep quality in patients with MS remains elusive. Objective: In this study, we aim to quantify the impact of the ANS and MS on perceived sleep quality. Methods: We monitored 77 participants over 2 weeks using an arm-worn wearable sensor and a custom smartphone app. Besides recording daily perceived sleep quality, we continuously recorded participants’ heart rate (HR) and HR variability on a per-second basis, as well as stress, activity, and the weather (20,700 hours of sensor data). Results: During sleep, we found that reduced HR variability and increased motion led to lower perceived sleep quality in patients with MS (n=53) as well as the age- and gender-matched control group (n=24). An activated stress response (high sympathetic activity and low parasympathetic activity) while asleep resulted in lower perceived sleep quality. For patients with MS, an activated stress response while asleep reduced perceived sleep quality more heavily than in the control group. Similarly, the effect of increased stress levels throughout the day is particularly severe for patients with MS. For patients with MS, we found that stress correlated negatively with minimal observed HR while asleep and might even affect their daily routine. We found that patients with MS with more severe impairments generally recorded lower perceived sleep quality than patients with MS with less severe disease progression. Conclusions: For patients with MS, stress throughout the day and an activated stress response while asleep play a crucial role in determining sleep quality, whereas this is less important for healthy individuals. Besides ensuring an adequate sleep duration, patients with MS might thus work to reduce stressors, which seem to have a particularly negative effect on sleep quality. Generally, however, sleep quality decreases with MS disease progression.
- Open Access
LLM-for-X: Application-agnostic Integration of Large Language Models to Support Personal Writing Workflows
To enhance productivity and to streamline workflows, there is a growing trend to embed large language model (LLM) functionality into applications, from browser-based web apps to native apps that run on personal computers. Here, we introduce LLM-for-X, a system-wide shortcut layer that seamlessly augments any application with LLM services through a lightweight popup dialog. Our native layer seamlessly connects front-end applications to popular LLM backends, such as ChatGPT and Gemini, using their uniform chat front-ends as the programming interface or their custom API calls. We demonstrate the benefits of LLM-for-X across a wide variety of applications, including Microsoft Office, VSCode, and Adobe Acrobat as well as popular web apps such as Overleaf. In our evaluation, we compared LLM-for-X with ChatGPT's web interface in a series of tasks, showing that our approach can provide users with quick, efficient, and easy-to-use LLM assistance without context switching to support writing and reading tasks that is agnostic of the specific application.
Open AccessLLM-for-X: Application-agnostic Integration of Large Language Models to Support Personal Writing Workflows
To enhance productivity and to streamline workflows, there is a growing trend to embed large language model (LLM) functionality into applications, from browser-based web apps to native apps that run on personal computers. Here, we introduce LLM-for-X, a system-wide shortcut layer that seamlessly augments any application with LLM services through a lightweight popup dialog. Our native layer seamlessly connects front-end applications to popular LLM backends, such as ChatGPT and Gemini, using their uniform chat front-ends as the programming interface or their custom API calls. We demonstrate the benefits of LLM-for-X across a wide variety of applications, including Microsoft Office, VSCode, and Adobe Acrobat as well as popular web apps such as Overleaf. In our evaluation, we compared LLM-for-X with ChatGPT's web interface in a series of tasks, showing that our approach can provide users with quick, efficient, and easy-to-use LLM assistance without context switching to support writing and reading tasks that is agnostic of the specific application.
- Open Access
- 8 July 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (7) , e0305258
Personalized interpretable prediction of perceived sleep quality: Models with meaningful cardiovascular and behavioral features
Understanding a person’s perceived quality of sleep is an important problem, but hard due to its poor definition and high intra- as well as inter-individual variation. In the short term, sleep quality has an established impact on cognitive function during the following day as well as on fatigue. In the long term, good quality sleep is essential for mental and physical health and contributes to quality of life. Despite the need to better understand sleep quality as an early indicator for sleep disorders, perceived sleep quality has been rarely modeled for multiple consecutive days using biosignals. In this paper, we present novel insights on the association of cardiac activity and perceived sleep quality using an interpretable modeling approach utilizing the publicly available intensive-longitudinal study M2Sleep. Our method takes as input signals from commodity wearable devices, including motion and blood volume pulses. Despite processing only simple and clearly interpretable features, we achieve an accuracy of up to 70% with an AUC of 0.76 and reduce the error by up to 36% compared to related work. We further argue that collected biosignals and sleep quality labels should be normalized per-participant to enable a medically insightful analysis. Coupled with explainable models, this allows for the interpretations of effects on perceived sleep quality. Analysis revealed that besides higher skin temperature and sufficient sleep duration, especially higher average heart rate while awake and lower minimal activity of the parasympathetic and sympathetic nervous system while asleep increased the chances of higher sleep quality.
- 8 July 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (7) , e0305258
Open AccessPersonalized interpretable prediction of perceived sleep quality: Models with meaningful cardiovascular and behavioral features
Understanding a person’s perceived quality of sleep is an important problem, but hard due to its poor definition and high intra- as well as inter-individual variation. In the short term, sleep quality has an established impact on cognitive function during the following day as well as on fatigue. In the long term, good quality sleep is essential for mental and physical health and contributes to quality of life. Despite the need to better understand sleep quality as an early indicator for sleep disorders, perceived sleep quality has been rarely modeled for multiple consecutive days using biosignals. In this paper, we present novel insights on the association of cardiac activity and perceived sleep quality using an interpretable modeling approach utilizing the publicly available intensive-longitudinal study M2Sleep. Our method takes as input signals from commodity wearable devices, including motion and blood volume pulses. Despite processing only simple and clearly interpretable features, we achieve an accuracy of up to 70% with an AUC of 0.76 and reduce the error by up to 36% compared to related work. We further argue that collected biosignals and sleep quality labels should be normalized per-participant to enable a medically insightful analysis. Coupled with explainable models, this allows for the interpretations of effects on perceived sleep quality. Analysis revealed that besides higher skin temperature and sufficient sleep duration, especially higher average heart rate while awake and lower minimal activity of the parasympathetic and sympathetic nervous system while asleep increased the chances of higher sleep quality.
- Top Cited PapersOpen Access
- 11 March 2024
- Published by Springer Nature in npj Digital Medicine
- Vol. 7 (1) , 1-14
Modeling multiple sclerosis using mobile and wearable sensor data
Multiple sclerosis (MS) is a neurological disease of the central nervous system that is the leading cause of non-traumatic disability in young adults. Clinical laboratory tests and neuroimaging studies are the standard methods to diagnose and monitor MS. However, due to infrequent clinic visits, it is fundamental to identify remote and frequent approaches for monitoring MS, which enable timely diagnosis, early access to treatment, and slowing down disease progression. In this work, we investigate the mostreliable,clinically useful, andavailablefeatures derived from mobile and wearable devices as well as their ability to distinguish people with MS (PwMS) from healthy controls, recognize MS disability and fatigue levels. To this end, we formalize clinical knowledge and derive behavioral markers to characterize MS. We evaluate our approach on a dataset we collected from 55 PwMS and 24 healthy controls for a total of 489 days conducted in free-living conditions. The dataset containswearable sensor data– e.g., heart rate – collected using an arm-worn device,smartphone data– e.g., phone locks – collected through a mobile application,patient health records– e.g., MS type – obtained from the hospital, andself-reports– e.g., fatigue level – collected using validated questionnaires administered via the mobile application. Our results demonstrate the feasibility of using features derived from mobile and wearable sensors to monitor MS. Our findings open up opportunities for continuous monitoring of MS in free-living conditions and can be used to evaluate and guide the effectiveness of treatments, manage the disease, and identify participants for clinical trials.
- 11 March 2024
- Published by Springer Nature in npj Digital Medicine
- Vol. 7 (1) , 1-14
Top Cited PapersOpen AccessModeling multiple sclerosis using mobile and wearable sensor data
Multiple sclerosis (MS) is a neurological disease of the central nervous system that is the leading cause of non-traumatic disability in young adults. Clinical laboratory tests and neuroimaging studies are the standard methods to diagnose and monitor MS. However, due to infrequent clinic visits, it is fundamental to identify remote and frequent approaches for monitoring MS, which enable timely diagnosis, early access to treatment, and slowing down disease progression. In this work, we investigate the mostreliable,clinically useful, andavailablefeatures derived from mobile and wearable devices as well as their ability to distinguish people with MS (PwMS) from healthy controls, recognize MS disability and fatigue levels. To this end, we formalize clinical knowledge and derive behavioral markers to characterize MS. We evaluate our approach on a dataset we collected from 55 PwMS and 24 healthy controls for a total of 489 days conducted in free-living conditions. The dataset containswearable sensor data– e.g., heart rate – collected using an arm-worn device,smartphone data– e.g., phone locks – collected through a mobile application,patient health records– e.g., MS type – obtained from the hospital, andself-reports– e.g., fatigue level – collected using validated questionnaires administered via the mobile application. Our results demonstrate the feasibility of using features derived from mobile and wearable sensors to monitor MS. Our findings open up opportunities for continuous monitoring of MS in free-living conditions and can be used to evaluate and guide the effectiveness of treatments, manage the disease, and identify participants for clinical trials.
- Open Access
- 29 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-11
PressurePick: Muscle Tension Estimation for Guitar Players Using Unobtrusive Pressure Sensing
When learning to play an instrument, it is crucial for the learner’s muscles to be in a relaxed state when practicing. Identifying, which parts of a song lead to increased muscle tension requires self-awareness during an already cognitively demanding task. In this work, we investigate unobtrusive pressure sensing for estimating muscle tension while practicing songs with the guitar. First, we collected data from twelve guitarists. Our apparatus consisted of three pressure sensors (one on each side of the guitar pick and one on the guitar neck) to determine the sensor that is most suitable for automatically estimating muscle tension. Second, we extracted features from the pressure time series that are indicative of muscle tension. Third, we present the hardware and software design of our PressurePick prototype, which is directly informed by the data collection and subsequent analysis.
- 29 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-11
Open AccessPressurePick: Muscle Tension Estimation for Guitar Players Using Unobtrusive Pressure Sensing
When learning to play an instrument, it is crucial for the learner’s muscles to be in a relaxed state when practicing. Identifying, which parts of a song lead to increased muscle tension requires self-awareness during an already cognitively demanding task. In this work, we investigate unobtrusive pressure sensing for estimating muscle tension while practicing songs with the guitar. First, we collected data from twelve guitarists. Our apparatus consisted of three pressure sensors (one on each side of the guitar pick and one on the guitar neck) to determine the sensor that is most suitable for automatically estimating muscle tension. Second, we extracted features from the pressure time series that are indicative of muscle tension. Third, we present the hardware and software design of our PressurePick prototype, which is directly informed by the data collection and subsequent analysis.