Lucia Dumitrascu-Timis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lucia Dumitrascu-Timis has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ada Delean
Department of Conservative Odontology, Faculty of Dentistry, Iuliu Hațieganu University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania
1 shared publication - Andra Solea
Department of Conservative Odontology, Faculty of Dentistry, Iuliu Hațieganu University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania
1 shared publication - Francesca Zotti
Department of Surgical Sciences, Pediatrics and Gynecology, University of Verona, P.le L.A. Scuro 10, 37134 Verona, Italy
1 shared publication - Marius Bud
Department of Conservative Odontology, Faculty of Dentistry, Iuliu Hațieganu University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania
1 shared publication - Mehmet Eskibağlar
Department of Endodontics, Faculty of Dentistry, Firat University, Elazig 23119, Turkey
1 shared publication - Merve Yeniçeri Özata
Dicle University
1 shared publication
Latest Publications
- Open Access
- 24 November 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (23) , 11644
Precision of Composite Restoration Removal When Using a Dental Operating Microscope for the First Time: An Exploratory Volumetric Study
Magnification is widely recommended to improve precision when defective composite restorations are removed, but it is unclear whether this benefit is available to an operator using a microscope for the first time. This exploratory in vitro study quantified the effect of a dental operating microscope on the volumetric accuracy and consistency of composite removal performed by a novice. Forty-four extracted human mandibular molars each received one standardised cervical Class V cavity (3 × 2 × 1 mm), restored with a nanohybrid composite. A single third-year dental student without clinical or magnification experience removed the restorations either under a dental operating microscope at the second magnification step (n = 22) or without magnification (n = 22). Cavity volume was determined before restoration and after removal by cone-beam computed tomography (0.12 mm voxel) and intraoral scanning. Mean volumetric change (ΔV) did not differ between groups (microscope 0.589 ± 1.239 mm3; no magnification 0.807 ± 0.396 mm3; p = 0.44), but its variance was almost ten times greater with the microscope (p < 0.001). For this operator at first use, magnification did not improve the accuracy of removal, as estimated by net volumetric change, and markedly reduced its consistency. These exploratory findings, obtained from a single operator, suggest that a structured introduction of magnification may be needed and should be tested in larger samples.
- 24 November 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (23) , 11644
Open AccessPrecision of Composite Restoration Removal When Using a Dental Operating Microscope for the First Time: An Exploratory Volumetric Study
Magnification is widely recommended to improve precision when defective composite restorations are removed, but it is unclear whether this benefit is available to an operator using a microscope for the first time. This exploratory in vitro study quantified the effect of a dental operating microscope on the volumetric accuracy and consistency of composite removal performed by a novice. Forty-four extracted human mandibular molars each received one standardised cervical Class V cavity (3 × 2 × 1 mm), restored with a nanohybrid composite. A single third-year dental student without clinical or magnification experience removed the restorations either under a dental operating microscope at the second magnification step (n = 22) or without magnification (n = 22). Cavity volume was determined before restoration and after removal by cone-beam computed tomography (0.12 mm voxel) and intraoral scanning. Mean volumetric change (ΔV) did not differ between groups (microscope 0.589 ± 1.239 mm3; no magnification 0.807 ± 0.396 mm3; p = 0.44), but its variance was almost ten times greater with the microscope (p < 0.001). For this operator at first use, magnification did not improve the accuracy of removal, as estimated by net volumetric change, and markedly reduced its consistency. These exploratory findings, obtained from a single operator, suggest that a structured introduction of magnification may be needed and should be tested in larger samples.
- Open Access
- 15 October 2023
- Published by Zeus Publishing in International Dental Research
- Vol. 13 (S1) , 26-31
Comparison of ProTaper Ultimate, TruNatomy, and Rotate rotary files in apical debris extrusion
Aim: The aim of this study is to evaluate the amount of debris extruded apically by the primary shaping files of three rotary file systems manufactured with different alloy technologies [TruNatomy (TRN), ProTaper Ultimate (PTUltimate), and VDW.Rotate (VDW.R) files]. Methodology: Thirty lower premolar teeth with moderate curvature (10-20°) were randomly divided into three equal groups (n=10) according to three rotary file systems [TRN (26.04v), PTUltimate (25.08v), and VDW.R (25.06v)]. The debris extruded apically was collected in Eppendorf tubes of known weights. After preparation, the tubes were placed in an incubator at 70°C for five days to evaporate the distilled water. The tubes filled with debris were then weighed again, and the net weight of the extruded debris was calculated in grams (g) by subtracting the initial weight from the final weight. The data were analyzed using one-way ANOVA test. Results: There was no significant difference in the amount of debris extruded apically by the three shaping files (p > 0.05). The highest amount of debris extruded apically was 0.9534 g for PTUltimate. VDW.R extruded the minimum amount of debris apically, with 0.1833 g. Conclusion: All rotary files have caused apical debris extrusion. Even though there was no significant difference among the files, the VDW.R file extruded less debris compared to other file systems. How to cite this article: Eskibağlar M, Yeniçeri Özata M, Timis Ll. Comparison of ProTaper Ultimate, TruNatomy, and Rotate rotary files in apical debris extrusion. Int Dent Res 2023;13(S1):26-31. https://doi.org/10.5577/idr.2023.vol13.s1.4 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
- 15 October 2023
- Published by Zeus Publishing in International Dental Research
- Vol. 13 (S1) , 26-31
Open AccessComparison of ProTaper Ultimate, TruNatomy, and Rotate rotary files in apical debris extrusion
Aim: The aim of this study is to evaluate the amount of debris extruded apically by the primary shaping files of three rotary file systems manufactured with different alloy technologies [TruNatomy (TRN), ProTaper Ultimate (PTUltimate), and VDW.Rotate (VDW.R) files]. Methodology: Thirty lower premolar teeth with moderate curvature (10-20°) were randomly divided into three equal groups (n=10) according to three rotary file systems [TRN (26.04v), PTUltimate (25.08v), and VDW.R (25.06v)]. The debris extruded apically was collected in Eppendorf tubes of known weights. After preparation, the tubes were placed in an incubator at 70°C for five days to evaporate the distilled water. The tubes filled with debris were then weighed again, and the net weight of the extruded debris was calculated in grams (g) by subtracting the initial weight from the final weight. The data were analyzed using one-way ANOVA test. Results: There was no significant difference in the amount of debris extruded apically by the three shaping files (p > 0.05). The highest amount of debris extruded apically was 0.9534 g for PTUltimate. VDW.R extruded the minimum amount of debris apically, with 0.1833 g. Conclusion: All rotary files have caused apical debris extrusion. Even though there was no significant difference among the files, the VDW.R file extruded less debris compared to other file systems. How to cite this article: Eskibağlar M, Yeniçeri Özata M, Timis Ll. Comparison of ProTaper Ultimate, TruNatomy, and Rotate rotary files in apical debris extrusion. Int Dent Res 2023;13(S1):26-31. https://doi.org/10.5577/idr.2023.vol13.s1.4 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.