Christopher Coogan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Christopher Coogan has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Griffin W. Milsap
Research and Exploratory Development Department, Johns Hopkins University Applied Physics Laboratory
4 shared publications - Matthew S. Fifer
Research and Exploratory Development Department, Johns Hopkins Applied Physics Laboratory, Laurel, USA
4 shared publications - Miguel Angrick
Department of Neurology, Johns Hopkins University School of Medicine, Baltimore, USA
4 shared publications - Nathan E. Crone
Johns Hopkins University
4 shared publications - Nicolas Franciscus Ramsey
Department of Neurology and Neurosurgery, UMC Utrecht Brain Center, Utrecht, the Netherlands
4 shared publications - Shiyu Luo
Johns Hopkins University
4 shared publications
Latest Publications
- Open Access
Longitudinal study of gesture decoding in a clinical trial participant with ALS
Brain-computer interfaces (BCIs) have the potential to preserve or restore communication and device control in people with paralysis from a variety of causes. For people living with amyotrophic lateral sclerosis (ALS), however, the progressive loss of cortical motor neurons could theoretically pose a challenge to the stability of BCI performance. Here we tested the stability of gesture decoding with a chronic electrocorticographic (ECoG) BCI in a man living with ALS and participating in a clinical trial ( ClinicalTrials.gov , NCT03567213 ). We evaluated offline decoding performance of attempted gestures over two periods: a 5-week period beginning roughly 2 years post-implant and a 6-week period ending roughly 5 months later. Decoder sensitivity was high in both periods (90 - 98%), while classification accuracy was 37 - 68% in the first period and worsened to 23 - 39% in the second. We investigated multiple frequency bands that were used as model features in both periods, and we observed reductions in high gamma band power (70 - 110 Hz) and between-class separation during the second period compared to the first. Over the 5-month period motor function did not appreciably decline. These results, albeit preliminary, suggest that declines in the neural population responses that drive ECoG BCI performance can occur without overt signs of disease progression in people living with ALS, and could serve as a biomarker for disease progression in the future.
Open AccessLongitudinal study of gesture decoding in a clinical trial participant with ALS
Brain-computer interfaces (BCIs) have the potential to preserve or restore communication and device control in people with paralysis from a variety of causes. For people living with amyotrophic lateral sclerosis (ALS), however, the progressive loss of cortical motor neurons could theoretically pose a challenge to the stability of BCI performance. Here we tested the stability of gesture decoding with a chronic electrocorticographic (ECoG) BCI in a man living with ALS and participating in a clinical trial ( ClinicalTrials.gov , NCT03567213 ). We evaluated offline decoding performance of attempted gestures over two periods: a 5-week period beginning roughly 2 years post-implant and a 6-week period ending roughly 5 months later. Decoder sensitivity was high in both periods (90 - 98%), while classification accuracy was 37 - 68% in the first period and worsened to 23 - 39% in the second. We investigated multiple frequency bands that were used as model features in both periods, and we observed reductions in high gamma band power (70 - 110 Hz) and between-class separation during the second period compared to the first. Over the 5-month period motor function did not appreciably decline. These results, albeit preliminary, suggest that declines in the neural population responses that drive ECoG BCI performance can occur without overt signs of disease progression in people living with ALS, and could serve as a biomarker for disease progression in the future.
- Open Access
Self-paced silent speech brain-computer interface for device control
Brain-computer interfaces can potentially restore autonomy to people with paralysis, including the ability to control their own environment via smart devices in the home. BCI applications for controlling smart devices to date have required visual displays or auditory cues, limiting the user’s ability to autonomously and privately issue commands. In this study, a clinical trial participant with amyotrophic lateral sclerosis (ALS) used a chronically implanted electrocorticographic (ECoG) BCI to control smart devices with self-paced silent speech commands. Across 18 experimental sessions, silently mimed speech commands were detected in real time and decoded with a median accuracy of 97.1% (chance: 7.14%). These results demonstrate that silently attempted speech can be reliably decoded without exogenous timing cues, supporting the feasibility of reliable autonomous smart device control with an implantable BCI.
Open AccessSelf-paced silent speech brain-computer interface for device control
Brain-computer interfaces can potentially restore autonomy to people with paralysis, including the ability to control their own environment via smart devices in the home. BCI applications for controlling smart devices to date have required visual displays or auditory cues, limiting the user’s ability to autonomously and privately issue commands. In this study, a clinical trial participant with amyotrophic lateral sclerosis (ALS) used a chronically implanted electrocorticographic (ECoG) BCI to control smart devices with self-paced silent speech commands. Across 18 experimental sessions, silently mimed speech commands were detected in real time and decoded with a median accuracy of 97.1% (chance: 7.14%). These results demonstrate that silently attempted speech can be reliably decoded without exogenous timing cues, supporting the feasibility of reliable autonomous smart device control with an implantable BCI.
- Open Access
- 22 October 2024
- Published by Springer Nature in Communications Medicine
- Vol. 4 (1) , 1-14
A click-based electrocorticographic brain-computer interface enables long-term high-performance switch scan spelling
Background: Brain-computer interfaces (BCIs) can restore communication for movement- and/or speech-impaired individuals by enabling neural control of computer typing applications. Single command click detectors provide a basic yet highly functional capability. Methods: We sought to test the performance and long-term stability of click decoding using a chronically implanted high density electrocorticographic (ECoG) BCI with coverage of the sensorimotor cortex in a human clinical trial participant (ClinicalTrials.gov, NCT03567213) with amyotrophic lateral sclerosis. We trained the participant’s click detector using a small amount of training data (<44 min across 4 days) collected up to 21 days prior to BCI use, and then tested it over a period of 90 days without any retraining or updating. Results: Using a click detector to navigate a switch scanning speller interface, the study participant can maintain a median spelling rate of 10.2 characters per min. Though a transient reduction in signal power modulation can interrupt usage of a fixed model, a new click detector can achieve comparable performance despite being trained with even less data (<15 min, within 1 day). Conclusions: These results demonstrate that a click detector can be trained with a small ECoG dataset while retaining robust performance for extended periods, providing functional text-based communication to BCI users.
- 22 October 2024
- Published by Springer Nature in Communications Medicine
- Vol. 4 (1) , 1-14
Open AccessA click-based electrocorticographic brain-computer interface enables long-term high-performance switch scan spelling
Background: Brain-computer interfaces (BCIs) can restore communication for movement- and/or speech-impaired individuals by enabling neural control of computer typing applications. Single command click detectors provide a basic yet highly functional capability. Methods: We sought to test the performance and long-term stability of click decoding using a chronically implanted high density electrocorticographic (ECoG) BCI with coverage of the sensorimotor cortex in a human clinical trial participant (ClinicalTrials.gov, NCT03567213) with amyotrophic lateral sclerosis. We trained the participant’s click detector using a small amount of training data (<44 min across 4 days) collected up to 21 days prior to BCI use, and then tested it over a period of 90 days without any retraining or updating. Results: Using a click detector to navigate a switch scanning speller interface, the study participant can maintain a median spelling rate of 10.2 characters per min. Though a transient reduction in signal power modulation can interrupt usage of a fixed model, a new click detector can achieve comparable performance despite being trained with even less data (<15 min, within 1 day). Conclusions: These results demonstrate that a click detector can be trained with a small ECoG dataset while retaining robust performance for extended periods, providing functional text-based communication to BCI users.
- Top Cited PapersOpen Access
- 24 October 2023
- Published by Wiley in Advanced Science
- Vol. 10 (35) , e2304853
Stable Decoding from a Speech BCI Enables Control for an Individual with ALS without Recalibration for 3 Months
Brain‐computer interfaces (BCIs) can be used to control assistive devices by patients with neurological disorders like amyotrophic lateral sclerosis (ALS) that limit speech and movement. For assistive control, it is desirable for BCI systems to be accurate and reliable, preferably with minimal setup time. In this study, a participant with severe dysarthria due to ALS operates computer applications with six intuitive speech commands via a chronic electrocorticographic (ECoG) implant over the ventral sensorimotor cortex. Speech commands are accurately detected and decoded (median accuracy: 90.59%) throughout a 3‐month study period without model retraining or recalibration. Use of the BCI does not require exogenous timing cues, enabling the participant to issue self‐paced commands at will. These results demonstrate that a chronically implanted ECoG‐based speech BCI can reliably control assistive devices over long time periods with only initial model training and calibration, supporting the feasibility of unassisted home use.
- 24 October 2023
- Published by Wiley in Advanced Science
- Vol. 10 (35) , e2304853
Top Cited PapersOpen AccessStable Decoding from a Speech BCI Enables Control for an Individual with ALS without Recalibration for 3 Months
Brain‐computer interfaces (BCIs) can be used to control assistive devices by patients with neurological disorders like amyotrophic lateral sclerosis (ALS) that limit speech and movement. For assistive control, it is desirable for BCI systems to be accurate and reliable, preferably with minimal setup time. In this study, a participant with severe dysarthria due to ALS operates computer applications with six intuitive speech commands via a chronic electrocorticographic (ECoG) implant over the ventral sensorimotor cortex. Speech commands are accurately detected and decoded (median accuracy: 90.59%) throughout a 3‐month study period without model retraining or recalibration. Use of the BCI does not require exogenous timing cues, enabling the participant to issue self‐paced commands at will. These results demonstrate that a chronically implanted ECoG‐based speech BCI can reliably control assistive devices over long time periods with only initial model training and calibration, supporting the feasibility of unassisted home use.