Mathini Vaseekaran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mathini Vaseekaran has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Gerrit Jansen
University Department of Anesthesiology, Intensive Care Medicine, Emergency Medicine and Pain Medicine, Johannes Wesling Klinikum Minden, Ruhr University Bochum, Minden, Germany
4 shared publications - Annika Hoyer
Bielefeld University
3 shared publications - Bernd Strickmann
Ärztlicher Leiter Rettungsdienst Kreis Gütersloh
3 shared publications - Jochen Hinkelbein
University Department of Anaesthesiology, Intensive Care Medicine, Emergency Medicine and Pain Medicine, Johannes Wesling Klinikum Minden, Ruhr University Bochum, Minden, Germany
3 shared publications - Julia Johanna Grannemann
Emergency Medical Service; City and District of Guetersloh, Herzebrocker Strasse 140, 33324 Guetersloh, Germany
3 shared publications - Alexander Samol
Department of Cardiology and Critical Care Medicine, Johannes Wesling University Hospital, 32429 Minden, Germany
2 shared publications
Latest Publications
- Open Access
- 24 March 2026
- Published by Springer Nature in International Journal of Emergency Medicine
- Vol. 19 (1)
Performance of the new Laryngeal Tube LT®evo during simulated resuscitation: a randomised crossover manikin study
Background: Effective airway management is essential for high-quality cardiopulmonary resuscitation (CPR). While tracheal intubation (TI) has traditionally been regarded as the reference technique for advanced airway management, it requires substantial expertise and may prolong no-flow time during CPR. Current European Resuscitation Council (ERC) guidelines recommend the i-gel ® as the preferred supraglottic airway (SGA). The newly developed Laryngeal Tube LT ® evo (VBM Medizintechnik, Germany) was designed to simplify insertion and improve ventilation performance. This study evaluated its efficacy compared with bag-valve-mask-ventilation (BVM) and tracheal intubation (TI) in a standardized resuscitation scenario. Methods: In this prospective, randomised crossover manikin study, 20 anaesthesiologists with varying experience in prehospital and in-hospital Airway management during CPR performed three resuscitation scenarios using BVM, TI, or LT ® evo in random order. Each 5-minute scenario simulated a cardiac arrest with initial shockable rhythm and required up to three mandatory defibrillations. The primary endpoint was total no-flow time. Secondary endpoints included device insertion time, time-to-first-effective-ventilation (tidal-volume ≥ 400 mL), and number of insufficient ventilations. Results: All 60 simulations were completed. Compared with LT ® evo, BVM produced statistically longer no-flow time (regression coefficient [RC] = 4.00; 95%-CI = 0.13–7.87), a higher rate of insufficient ventilations (RC = 1.25; 95%CI = 0.44–2.09), and lower tidal-volumes (RC = − 66.05; 95%CI = − 124.75- −7.35). Compared to LT ® evo, there was no evidence for a difference in no-flow time for TI (RC = − 2.17; 95%CI = − 6.04–1.70) in experienced users. Conclusion: In this first evaluation of the LT ® evo, the device enabled rapid, effective ventilation with minimal interruption of chest compressions. Its ease of use and observed performance characteristics support further clinical investigation as potential alternative SGA for resuscitation.
- 24 March 2026
- Published by Springer Nature in International Journal of Emergency Medicine
- Vol. 19 (1)
Open AccessPerformance of the new Laryngeal Tube LT®evo during simulated resuscitation: a randomised crossover manikin study
Background: Effective airway management is essential for high-quality cardiopulmonary resuscitation (CPR). While tracheal intubation (TI) has traditionally been regarded as the reference technique for advanced airway management, it requires substantial expertise and may prolong no-flow time during CPR. Current European Resuscitation Council (ERC) guidelines recommend the i-gel ® as the preferred supraglottic airway (SGA). The newly developed Laryngeal Tube LT ® evo (VBM Medizintechnik, Germany) was designed to simplify insertion and improve ventilation performance. This study evaluated its efficacy compared with bag-valve-mask-ventilation (BVM) and tracheal intubation (TI) in a standardized resuscitation scenario. Methods: In this prospective, randomised crossover manikin study, 20 anaesthesiologists with varying experience in prehospital and in-hospital Airway management during CPR performed three resuscitation scenarios using BVM, TI, or LT ® evo in random order. Each 5-minute scenario simulated a cardiac arrest with initial shockable rhythm and required up to three mandatory defibrillations. The primary endpoint was total no-flow time. Secondary endpoints included device insertion time, time-to-first-effective-ventilation (tidal-volume ≥ 400 mL), and number of insufficient ventilations. Results: All 60 simulations were completed. Compared with LT ® evo, BVM produced statistically longer no-flow time (regression coefficient [RC] = 4.00; 95%-CI = 0.13–7.87), a higher rate of insufficient ventilations (RC = 1.25; 95%CI = 0.44–2.09), and lower tidal-volumes (RC = − 66.05; 95%CI = − 124.75- −7.35). Compared to LT ® evo, there was no evidence for a difference in no-flow time for TI (RC = − 2.17; 95%CI = − 6.04–1.70) in experienced users. Conclusion: In this first evaluation of the LT ® evo, the device enabled rapid, effective ventilation with minimal interruption of chest compressions. Its ease of use and observed performance characteristics support further clinical investigation as potential alternative SGA for resuscitation.
- Open Access
- 21 January 2026
- Published by Springer Nature in Trials
- Vol. 27 (1) , 69
Peri-arrest ventilation with positive end-expiratory-pressure vs. zero end-expiratory-pressure in out-of-hospital-cardiac-arrest (PerAVent)—a prospective, cluster-randomized multicenter trial
Background: Out-of-hospital cardiac arrest (OHCA) remains a major cause of mortality, with low survival probabilities to hospital discharge. Despite the frequent use of airway management and mechanical ventilation during resuscitation, there is limited evidence regarding the optimal ventilation strategy to improve oxygen delivery and patient outcomes. The present study aims to investigate the effects of positive-end-expiratory-pressure (PEEP) set at 5 mbar compared to zero-end-expiratory-pressure (ZEEP) on the return of spontaneous-circulation (ROSC) in adult patients with OHCA. Methods: This is a prospective, multicenter, cluster-randomized controlled trial conducted across emergency medical services (EMS) in the regions of Gütersloh, Minden-Lübbecke, and Osnabrück. Adult patients (≥ 18 years) with OHCA who are undergoing mechanical ventilation through an airway device will be enrolled. The clusters (regional districts) will be randomized into two groups: one group will receive ventilation with PEEP set at 5 mbar (intervention group), while the other group will receive ventilation with ZEEP (control group). The study’s primary endpoint is the occurence of ROSC. Secondary endpoints include occurence of re-arrest, death during pre-hospital care phase, hospital admission during ongoing resuscitation, hospital admission with spontaneous circulation, peripheral oxygen saturation, and endtidal CO 2 at hospital admission. Discussion: Optimal ventilation strategies during OHCA have not been well established. The use of PEEP may improve oxygenation and oxygen delivery. This study aims to provide crucial data on whether the application of PEEP at 5 mbar vs. 0 mbar can improve the probability of ROSC without adversely affecting hemodynamics. The findings could inform future guidelines on ventilation strategies in resuscitation. Trial registration: The trial is registered on ClinicalTrials.gov under the registration number NCT06836830. 24.02.2025 https://clinicaltrials.gov/study/NCT06836830?term=gerrit%20jansen&rank=2 .
- 21 January 2026
- Published by Springer Nature in Trials
- Vol. 27 (1) , 69
Open AccessPeri-arrest ventilation with positive end-expiratory-pressure vs. zero end-expiratory-pressure in out-of-hospital-cardiac-arrest (PerAVent)—a prospective, cluster-randomized multicenter trial
Background: Out-of-hospital cardiac arrest (OHCA) remains a major cause of mortality, with low survival probabilities to hospital discharge. Despite the frequent use of airway management and mechanical ventilation during resuscitation, there is limited evidence regarding the optimal ventilation strategy to improve oxygen delivery and patient outcomes. The present study aims to investigate the effects of positive-end-expiratory-pressure (PEEP) set at 5 mbar compared to zero-end-expiratory-pressure (ZEEP) on the return of spontaneous-circulation (ROSC) in adult patients with OHCA. Methods: This is a prospective, multicenter, cluster-randomized controlled trial conducted across emergency medical services (EMS) in the regions of Gütersloh, Minden-Lübbecke, and Osnabrück. Adult patients (≥ 18 years) with OHCA who are undergoing mechanical ventilation through an airway device will be enrolled. The clusters (regional districts) will be randomized into two groups: one group will receive ventilation with PEEP set at 5 mbar (intervention group), while the other group will receive ventilation with ZEEP (control group). The study’s primary endpoint is the occurence of ROSC. Secondary endpoints include occurence of re-arrest, death during pre-hospital care phase, hospital admission during ongoing resuscitation, hospital admission with spontaneous circulation, peripheral oxygen saturation, and endtidal CO 2 at hospital admission. Discussion: Optimal ventilation strategies during OHCA have not been well established. The use of PEEP may improve oxygenation and oxygen delivery. This study aims to provide crucial data on whether the application of PEEP at 5 mbar vs. 0 mbar can improve the probability of ROSC without adversely affecting hemodynamics. The findings could inform future guidelines on ventilation strategies in resuscitation. Trial registration: The trial is registered on ClinicalTrials.gov under the registration number NCT06836830. 24.02.2025 https://clinicaltrials.gov/study/NCT06836830?term=gerrit%20jansen&rank=2 .
- Open Access
- 4 December 2025
- Published by Elsevier in Resuscitation
- Vol. 219, 110918
Tracheal intubation vs. supraglottic airway devices during mechanical intra-arrest-ventilation with volume-controlled-ventilation in out-of-hospital cardiac arrest: a cohort study
- 4 December 2025
- Published by Elsevier in Resuscitation
- Vol. 219, 110918
Open AccessTracheal intubation vs. supraglottic airway devices during mechanical intra-arrest-ventilation with volume-controlled-ventilation in out-of-hospital cardiac arrest: a cohort study
- Open Access
- 16 July 2025
- Published by Springer Nature in Research Square
Peri-Arrest Ventilation with Positive End-Expiratory-Pressure vs. Zero End-Expiratory-Pressure in Out-of-Hospital-Cardiac-Arrest (PerAVent) – a prospective, cluster-randomized multicenter trial
Background: Out-of-hospital cardiac arrest (OHCA) remains a major cause of mortality, with low survival probabilities to hospital discharge. Despite the frequent use of airway management and mechanical ventilation during resuscitation, there is limited evidence regarding the optimal ventilation strategy to improve oxygen delivery and patient outcomes. The present study aims to investigate the effects of positive-end-expiratory-pressure (PEEP) set at 5mbar compared to zero-end-expiratory-pressure (ZEEP) on the return of spontaneous-circulation (ROSC) in adult patients with OHCA. Methods: This is a prospective, multicenter, cluster-randomized controlled trial conducted across emergency medical services (EMS) in the regions of Gütersloh, Minden-Lübbecke, and Osnabrück. Adult patients (≥18 years) with OHCA who are undergoing mechanical ventilation through an airway device will be enrolled. The clusters (regional districts) will be randomized into two groups: one group will receive ventilation with PEEP set at 5 mbar (intervention group), while the other group will receive ventilation with ZEEP (control group). The study's primary endpoint is the rate of ROSC. Secondary endpoints include rate of re-arrest, death during pre-hospital care phase, hospital admission during ongoing resuscitation, hospital admission with spontaneous circulation, peripheral oxygen saturation and endtidal CO2 at hospital admission. Discussion: Optimal ventilation strategies during OHCA have not been well established. The use of PEEP may improve oxygenation and oxygen delivery. This study aims to provide crucial data on whether the application of PEEP at 5 mbar vs. 0 mbar can improve the probability of ROSC without adversely affecting hemodynamics. The findings could inform future guidelines on ventilation strategies in resuscitation. Trial registration: The trial is registered on ClinicalTrials.gov under the registration number NCT06836830. 24.02.2025 https://clinicaltrials.gov/study/NCT06836830?term=gerrit%20jansen&rank=2
- 16 July 2025
- Published by Springer Nature in Research Square
Open AccessPeri-Arrest Ventilation with Positive End-Expiratory-Pressure vs. Zero End-Expiratory-Pressure in Out-of-Hospital-Cardiac-Arrest (PerAVent) – a prospective, cluster-randomized multicenter trial
Background: Out-of-hospital cardiac arrest (OHCA) remains a major cause of mortality, with low survival probabilities to hospital discharge. Despite the frequent use of airway management and mechanical ventilation during resuscitation, there is limited evidence regarding the optimal ventilation strategy to improve oxygen delivery and patient outcomes. The present study aims to investigate the effects of positive-end-expiratory-pressure (PEEP) set at 5mbar compared to zero-end-expiratory-pressure (ZEEP) on the return of spontaneous-circulation (ROSC) in adult patients with OHCA. Methods: This is a prospective, multicenter, cluster-randomized controlled trial conducted across emergency medical services (EMS) in the regions of Gütersloh, Minden-Lübbecke, and Osnabrück. Adult patients (≥18 years) with OHCA who are undergoing mechanical ventilation through an airway device will be enrolled. The clusters (regional districts) will be randomized into two groups: one group will receive ventilation with PEEP set at 5 mbar (intervention group), while the other group will receive ventilation with ZEEP (control group). The study's primary endpoint is the rate of ROSC. Secondary endpoints include rate of re-arrest, death during pre-hospital care phase, hospital admission during ongoing resuscitation, hospital admission with spontaneous circulation, peripheral oxygen saturation and endtidal CO2 at hospital admission. Discussion: Optimal ventilation strategies during OHCA have not been well established. The use of PEEP may improve oxygenation and oxygen delivery. This study aims to provide crucial data on whether the application of PEEP at 5 mbar vs. 0 mbar can improve the probability of ROSC without adversely affecting hemodynamics. The findings could inform future guidelines on ventilation strategies in resuscitation. Trial registration: The trial is registered on ClinicalTrials.gov under the registration number NCT06836830. 24.02.2025 https://clinicaltrials.gov/study/NCT06836830?term=gerrit%20jansen&rank=2
- Open Access
- 5 May 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (5)
WATCH-PR: Comparison of the Pulse Rate of a WATCH-Type Blood Pressure Monitor with the Pulse Rate of a Conventional Ambulatory Blood Pressure Monitor
Background: Monitoring pulse rate is fundamental to cardiovascular health management and early detection of rhythm disturbances. While oscillometric blood pressure measurement is well established and validated in clinical practice, its use for pulse rate monitoring, particularly via wrist-worn devices, remains largely unexplored. Objective: This study investigates whether a smartwatch that performs oscillometric blood pressure measurements at the wrist can also deliver reliable pulse rate readings using the same method. Methods: This study compared pulse rates recorded by the Omron HeartGuide smartwatch and conventional ambulatory blood pressure monitors in 50 patients over 24 h. Measurements were taken consecutively, and data were analyzed using intraclass correlation coefficients (ICCs) and Bland–Altman plots. Results: The study showed a high ICC of 0.971, indicating excellent agreement between devices. The average pulse rate difference was 1.5 bpm, with the Omron HeartGuide reporting slightly lower rates, especially in patients with atrial fibrillation. Conclusions: This study demonstrates that oscillometric pulse-rate monitoring at the wrist can achieve a high degree of accuracy, comparable to conventional upper-arm devices. Given that oscillometric smartwatches like the Omron HeartGuide are already used for blood pressure monitoring, the findings suggest that they may also be suitable for pulse rate measurement, potentially enhancing their role in telemetric healthcare, but further research is needed, particularly in patients with arrhythmias.
- 5 May 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (5)
Open AccessWATCH-PR: Comparison of the Pulse Rate of a WATCH-Type Blood Pressure Monitor with the Pulse Rate of a Conventional Ambulatory Blood Pressure Monitor
Background: Monitoring pulse rate is fundamental to cardiovascular health management and early detection of rhythm disturbances. While oscillometric blood pressure measurement is well established and validated in clinical practice, its use for pulse rate monitoring, particularly via wrist-worn devices, remains largely unexplored. Objective: This study investigates whether a smartwatch that performs oscillometric blood pressure measurements at the wrist can also deliver reliable pulse rate readings using the same method. Methods: This study compared pulse rates recorded by the Omron HeartGuide smartwatch and conventional ambulatory blood pressure monitors in 50 patients over 24 h. Measurements were taken consecutively, and data were analyzed using intraclass correlation coefficients (ICCs) and Bland–Altman plots. Results: The study showed a high ICC of 0.971, indicating excellent agreement between devices. The average pulse rate difference was 1.5 bpm, with the Omron HeartGuide reporting slightly lower rates, especially in patients with atrial fibrillation. Conclusions: This study demonstrates that oscillometric pulse-rate monitoring at the wrist can achieve a high degree of accuracy, comparable to conventional upper-arm devices. Given that oscillometric smartwatches like the Omron HeartGuide are already used for blood pressure monitoring, the findings suggest that they may also be suitable for pulse rate measurement, potentially enhancing their role in telemetric healthcare, but further research is needed, particularly in patients with arrhythmias.
- Open Access
WATCH-BPM—Comparison of a WATCH-Type Blood Pressure Monitor with a Conventional Ambulatory Blood Pressure Monitor and Auscultatory Sphygmomanometry
Background: Smart devices that are able to measure blood pressure (BP) are valuable for hypertension or heart failure management using digital technology. Data regarding their diagnostic accuracy in comparison to standard noninvasive measurement in accordance to Riva-Rocci are sparse. This study compared a wearable watch-type oscillometric BP monitor (Omron HeartGuide), a wearable watch-type infrared BP monitor (Smart Wear), a conventional ambulatory BP monitor, and auscultatory sphygmomanometry. Methods: Therefore, 159 consecutive patients (84 male, 75 female, mean age 64.33 ± 16.14 years) performed observed single measurements with the smart device compared to auscultatory sphygmomanometry (n = 109) or multiple measurements during 24 h compared to a conventional ambulatory BP monitor on the upper arm (n = 50). The two BP monitoring devices were simultaneously worn on the same arm throughout the monitoring period. In a subgroup of 50 patients, single measurements were also performed with an additional infrared smart device. Results: The intraclass correlation coefficient (ICC) between the difference and the mean of the oscillometric Omron HeartGuide and the conventional method for the single measurement was calculated for both systole (0.765) and diastole (0.732). This is exactly how the ICC was calculated for the individual mean values calculated over the 24 h long-term measurement of the individual patients for both systole (0.880) and diastole (0.829). The ICC between the infrared device and the conventional method was “bad” for SBP (0.329) and DBP (0.025). Therefore, no further long-term measurements were performed with the infrared device. Conclusion: The Omron HeartGuide device provided comparable BP values to the standard devices for single and long-term measurements. The infrared smart device failed to acquire valid measurement data.
Open AccessWATCH-BPM—Comparison of a WATCH-Type Blood Pressure Monitor with a Conventional Ambulatory Blood Pressure Monitor and Auscultatory Sphygmomanometry
Background: Smart devices that are able to measure blood pressure (BP) are valuable for hypertension or heart failure management using digital technology. Data regarding their diagnostic accuracy in comparison to standard noninvasive measurement in accordance to Riva-Rocci are sparse. This study compared a wearable watch-type oscillometric BP monitor (Omron HeartGuide), a wearable watch-type infrared BP monitor (Smart Wear), a conventional ambulatory BP monitor, and auscultatory sphygmomanometry. Methods: Therefore, 159 consecutive patients (84 male, 75 female, mean age 64.33 ± 16.14 years) performed observed single measurements with the smart device compared to auscultatory sphygmomanometry (n = 109) or multiple measurements during 24 h compared to a conventional ambulatory BP monitor on the upper arm (n = 50). The two BP monitoring devices were simultaneously worn on the same arm throughout the monitoring period. In a subgroup of 50 patients, single measurements were also performed with an additional infrared smart device. Results: The intraclass correlation coefficient (ICC) between the difference and the mean of the oscillometric Omron HeartGuide and the conventional method for the single measurement was calculated for both systole (0.765) and diastole (0.732). This is exactly how the ICC was calculated for the individual mean values calculated over the 24 h long-term measurement of the individual patients for both systole (0.880) and diastole (0.829). The ICC between the infrared device and the conventional method was “bad” for SBP (0.329) and DBP (0.025). Therefore, no further long-term measurements were performed with the infrared device. Conclusion: The Omron HeartGuide device provided comparable BP values to the standard devices for single and long-term measurements. The infrared smart device failed to acquire valid measurement data.