Syed Suraya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Syed Suraya has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Bakhodir Saydullaev
2 shared publicationsNagendra P. Yadav
2 shared publicationsSaiful Islam
2 shared publicationsSulton Usanov
2 shared publications- Adel Mohamed Amer Mohamed
Metallurgical and Materials Engineering Department, Faculty of Petroleum and Mining Engineering, Suez University, Suez, Egypt
1 shared publication Ali Ahmadi Peyghan
1 shared publication
Latest Publications
- 14 August 2026
- Published by Elsevier in Chinese Journal of Physics
- Vol. 104, 565-577
Fisher information and thermodynamic properties in a Calogero-like potential under topological defect and varying magnetic fields
- 14 August 2026
- Published by Elsevier in Chinese Journal of Physics
- Vol. 104, 565-577
Fisher information and thermodynamic properties in a Calogero-like potential under topological defect and varying magnetic fields
- Open Access
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 14 (4) , 816-825
Frequency control of hybrid power system with fractional order secondary controller using improved biogeography-based krill herd algorithm
To meet the demand of electrical power, structural changes of the power system from the generation side are necessary by integrating the renewable sources into the existing system. In the presence of renewables, the active power imbalances caused by both generation and demand are reduced with the classical units (like thermal) since the wind speed and irradiance (inputs of wind and solar plants) are volatile and nonlinear in nature. The frequency deviations triggered by such active power imbalances of the hybrid power system integrated with both conventional and renewable energy plants are minimized with better secondary control schemes. Therefore, this article suggests fractional order secondary controller (FOSC) for conventional units of the interconnected power system to strengthen the frequency stability of the system during the demand perturbations. The optimal gains of the FOSC are identified with an improved biogeography-based krill herd optimizer with the help of the performance indicator integral square error. To elevate the improvements of FOSC, comparisons are provided with classical controllers during the simple, random load perturbations with and without generation changes. Furthermore, sensitivity analysis on system parameters is performed to show the robustness of the FOSC over classical control strategies.
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 14 (4) , 816-825
Open AccessFrequency control of hybrid power system with fractional order secondary controller using improved biogeography-based krill herd algorithm
To meet the demand of electrical power, structural changes of the power system from the generation side are necessary by integrating the renewable sources into the existing system. In the presence of renewables, the active power imbalances caused by both generation and demand are reduced with the classical units (like thermal) since the wind speed and irradiance (inputs of wind and solar plants) are volatile and nonlinear in nature. The frequency deviations triggered by such active power imbalances of the hybrid power system integrated with both conventional and renewable energy plants are minimized with better secondary control schemes. Therefore, this article suggests fractional order secondary controller (FOSC) for conventional units of the interconnected power system to strengthen the frequency stability of the system during the demand perturbations. The optimal gains of the FOSC are identified with an improved biogeography-based krill herd optimizer with the help of the performance indicator integral square error. To elevate the improvements of FOSC, comparisons are provided with classical controllers during the simple, random load perturbations with and without generation changes. Furthermore, sensitivity analysis on system parameters is performed to show the robustness of the FOSC over classical control strategies.
- Open Access
- 1 November 2023
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 32 (2) , 587-597
Feasibility study of rooftop solar photovoltaic system for 33/11 kV primary substation at Al Suwairah
This article presents an overview of the technical and financial feasibility analysis of integrating a photovoltaic (PV) source with the conventional power system to supply the auxiliary load at the Al Suwairah 33/11 kV primary substation (PSS) in Suhar, Sultanate of Oman. This study estimates the required electrical energy for the primary substation's auxiliary load. A method is implemented to utilize the available area in the primary substation for determining the solar photovoltaic system's capacity. PVSyst software is employed to determine the ideal system capacity. The proposed solar PV system's payback period and overall annual savings have been evaluated using a series of simulated analyses. The proposed PV can inject 172.5 MWh/year with an average performance ratio of 0.826. The economic evaluation by the photovoltaic system (PVSyst) considering the present auxiliary load at the Al Suwarah PSS has suggested a total payback period of 8.9 years which is quite feasible. The cost of power generated by the proposed system is 49.2% less than the cost of power supplied from the utility service provider.
- 1 November 2023
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 32 (2) , 587-597
Open AccessFeasibility study of rooftop solar photovoltaic system for 33/11 kV primary substation at Al Suwairah
This article presents an overview of the technical and financial feasibility analysis of integrating a photovoltaic (PV) source with the conventional power system to supply the auxiliary load at the Al Suwairah 33/11 kV primary substation (PSS) in Suhar, Sultanate of Oman. This study estimates the required electrical energy for the primary substation's auxiliary load. A method is implemented to utilize the available area in the primary substation for determining the solar photovoltaic system's capacity. PVSyst software is employed to determine the ideal system capacity. The proposed solar PV system's payback period and overall annual savings have been evaluated using a series of simulated analyses. The proposed PV can inject 172.5 MWh/year with an average performance ratio of 0.826. The economic evaluation by the photovoltaic system (PVSyst) considering the present auxiliary load at the Al Suwarah PSS has suggested a total payback period of 8.9 years which is quite feasible. The cost of power generated by the proposed system is 49.2% less than the cost of power supplied from the utility service provider.