Samart Yachiangkam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Samart Yachiangkam has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Anawach Sangswang
Department of Electrical Engineering, Faculty of Engineering, King Mongkut's University of Technology Thonburi (KMUTT), Bangkok, Thailand
8 shared publicationsSaichol Chudjuarjeen
7 shared publications- Anon Namin
Clean Energy System Research Unit (CES-RMUTL), Division of Electrical Engineering, Faculty of Engineering, Rajamangala University of Technology Lanna (RMUTL), Chiang Mai 50300, Thailand
6 shared publications Chayant Koompai
6 shared publicationsSumate Naetiladdanon
Department of Electrical Engineering, Faculty of Engineering, King Mongkut's University of Technology Thonburi (KMUTT), Bangkok, Thailand
6 shared publicationsJirapong Jittakort
Faculty of Technical education, Rajamangala University of Technology Thanyaburi Pathumthani, Thailand
5 shared publications
Latest Publications
- Open Access
Varied-Frequency CC–CV Inductive Wireless Power Transfer with Efficiency-Regulated EV Charging for an Electric Golf Cart
Wireless electric vehicle (EV) charging is an important operation for valuable EV options in modern life. Inductive wireless EV charging needs constant current and voltage (CC–CV) charge controllers. This paper presents 750 W variable frequency CC–CV inductive wireless charging for an e-golf cart 50 Ah 72 V Li-ion battery. Due to this system’s low power, the system’s efficiency may be weak; the secondary-side (SS) maximum efficiency-controlled (MEC) converter was validated. The golf cart’s battery characteristics were evaluated to design and experiment with inductive wireless power transfer (IPT) coils and an integration system for a 42 kHz resonant frequency. The CC–CV charged control is an infrastructural part of the H-bridge inverter at varied frequencies from 50 kHz to 56 kHz when the DC input voltage is 310 V, and in the range of 44 kHz to 46 kHz at the 155 V input. The results found the charging of 9 A CC, 82 V CV and 730 W. The 310 V input voltage system without the SS MEC converter’s efficiencies was 62% to 72% and it was improved to 65% to 81% using the SS MEC converter. Finally, the best cases were validated at the 155 V DC input voltage and the system with the SS MEC converter had 76% to 86% efficiency.
Open AccessVaried-Frequency CC–CV Inductive Wireless Power Transfer with Efficiency-Regulated EV Charging for an Electric Golf Cart
Wireless electric vehicle (EV) charging is an important operation for valuable EV options in modern life. Inductive wireless EV charging needs constant current and voltage (CC–CV) charge controllers. This paper presents 750 W variable frequency CC–CV inductive wireless charging for an e-golf cart 50 Ah 72 V Li-ion battery. Due to this system’s low power, the system’s efficiency may be weak; the secondary-side (SS) maximum efficiency-controlled (MEC) converter was validated. The golf cart’s battery characteristics were evaluated to design and experiment with inductive wireless power transfer (IPT) coils and an integration system for a 42 kHz resonant frequency. The CC–CV charged control is an infrastructural part of the H-bridge inverter at varied frequencies from 50 kHz to 56 kHz when the DC input voltage is 310 V, and in the range of 44 kHz to 46 kHz at the 155 V input. The results found the charging of 9 A CC, 82 V CV and 730 W. The 310 V input voltage system without the SS MEC converter’s efficiencies was 62% to 72% and it was improved to 65% to 81% using the SS MEC converter. Finally, the best cases were validated at the 155 V DC input voltage and the system with the SS MEC converter had 76% to 86% efficiency.
- 29 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A Wide Bandgap Three-level Buck Converter with Power Balance Control Technique for High Power Density Applications – Design and Simulation
The design and simulation of a wide bandgap three-level buck converter controlled by the power balance control technique are presented in this paper. The proposed system represents high power-density and high performance compared to a conventional buck converter. The reduced passive component size of the system can be archived by high switching frequency design using Gallium Nitride (GaN) based and high robustness power balance control technique. The proposed system is simulated in MATLAB Simulink.
- 29 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A Wide Bandgap Three-level Buck Converter with Power Balance Control Technique for High Power Density Applications – Design and Simulation
The design and simulation of a wide bandgap three-level buck converter controlled by the power balance control technique are presented in this paper. The proposed system represents high power-density and high performance compared to a conventional buck converter. The reduced passive component size of the system can be archived by high switching frequency design using Gallium Nitride (GaN) based and high robustness power balance control technique. The proposed system is simulated in MATLAB Simulink.
- 24 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Implementation of Half-Bridge Class D Voltage-Source Inverter for Domestic Medical Applications
This paper presents an implementation of a class D voltage-source inverter employing a half-bridge series-resonant circuit for domestic medical applications, focusing on the benefits of a magnetic resonant coupling and temperature time for nanoparticle heating process by magnetic field induction. The output power of the inverter can be controlled by the switching frequency with the fixed duty cycle. The switching frequency operates slightly higher than the resonant frequency at any power level to maintain the zero-voltage switching (ZVS) conditions under the high-quality factor. The results are conducted by computer simulation and experimental studies to confirm the validity of the proposed method from a lab prototype.
- 24 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Implementation of Half-Bridge Class D Voltage-Source Inverter for Domestic Medical Applications
This paper presents an implementation of a class D voltage-source inverter employing a half-bridge series-resonant circuit for domestic medical applications, focusing on the benefits of a magnetic resonant coupling and temperature time for nanoparticle heating process by magnetic field induction. The output power of the inverter can be controlled by the switching frequency with the fixed duty cycle. The switching frequency operates slightly higher than the resonant frequency at any power level to maintain the zero-voltage switching (ZVS) conditions under the high-quality factor. The results are conducted by computer simulation and experimental studies to confirm the validity of the proposed method from a lab prototype.
- 15 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1481-1488
Variable Frequency Control for Constant Current Constant Voltage Inductive Wireless EV Charging System
EV market has risen despite COVID-19 pandemic. Wireless EV charging is safer operating, saves the environment, and is convenient with automated charging. Inductive wireless EV Charging (IPT) should be fewer power electronics components to improve the system's efficiency. This paper presents the fewer components constant current - constant voltage (CC-CV) IPT using frequency adaptive frequency control technique that does not need a primary dc-dc converter. The proposed CC-CV IPT charging building block consists of the front-end rectifier, CC-CV frequency controlled inverter, IPT coils, secondary high-frequency rectifier, and step resistive load battery simulator. The load current and voltage signals are detected and feedback to the PI control block that controls the frequency of the PWM gate drive of the inverter. The simulation and experimental results show the operating mode of 6A CC and 102 V CV chargings were performed. The wireless EV charging can be operated for the CC and CV chargings using variable frequency control.
- 15 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1481-1488
Variable Frequency Control for Constant Current Constant Voltage Inductive Wireless EV Charging System
EV market has risen despite COVID-19 pandemic. Wireless EV charging is safer operating, saves the environment, and is convenient with automated charging. Inductive wireless EV Charging (IPT) should be fewer power electronics components to improve the system's efficiency. This paper presents the fewer components constant current - constant voltage (CC-CV) IPT using frequency adaptive frequency control technique that does not need a primary dc-dc converter. The proposed CC-CV IPT charging building block consists of the front-end rectifier, CC-CV frequency controlled inverter, IPT coils, secondary high-frequency rectifier, and step resistive load battery simulator. The load current and voltage signals are detected and feedback to the PI control block that controls the frequency of the PWM gate drive of the inverter. The simulation and experimental results show the operating mode of 6A CC and 102 V CV chargings were performed. The wireless EV charging can be operated for the CC and CV chargings using variable frequency control.
- 9 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Characteristics of Steady-state, Pulse, and Programmable of Tungsten Halogen Solar Simulator
The steady-state and pulse solar simulators were the light source to measure the current-voltage characteristics of the photovoltaic (PV) cell or panel or test for the hot spot endurance test according to the IEC 61215 and the IEC 61646 standards. The programmable solar array simulator tests the PV system, but it is high cost. The programmable solar simulator is the choice for the lower price. This paper presents the low-cost programmable tungsten solar simulator with 8.0% non-uniformity 3.0% steady-state temporal instability. The test plane irradiance was according to the reference with a correlation coefficient of 0.95.
- 9 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Characteristics of Steady-state, Pulse, and Programmable of Tungsten Halogen Solar Simulator
The steady-state and pulse solar simulators were the light source to measure the current-voltage characteristics of the photovoltaic (PV) cell or panel or test for the hot spot endurance test according to the IEC 61215 and the IEC 61646 standards. The programmable solar array simulator tests the PV system, but it is high cost. The programmable solar simulator is the choice for the lower price. This paper presents the low-cost programmable tungsten solar simulator with 8.0% non-uniformity 3.0% steady-state temporal instability. The test plane irradiance was according to the reference with a correlation coefficient of 0.95.
- 9 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Wireless Golf Cart Charging Development in Thailand
Electric golf cart is a simple model electric vehicle (EV) with dependent charger up on the manufacturers. Using wireless EV charging technology for the e-golf cart is the stage to apply our wireless EV charger prototype for the simple model EV. The e-golf cart that used the 300 Ah 36V deep cycle lead-acid battery is used to be a sample. The wireless charging kits consist of 100 mm air-gap inductive wireless power primary and secondary coils, an 80 kHz 300 V, H-bridge inverter, primary side rectifier and constant current controlled dc-dc converter, and a secondary side rectifier. The results found that when primary rectified dc input voltage was 300V. The controlled battery current was 10A ±0.5A: the battery voltage was little varied in the range of 38 to 40 V. The load power varied in the range of 405 to 410 W, and the dc-dc efficiency of the system was varied in the field of 70 to 80 %.
- 9 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Wireless Golf Cart Charging Development in Thailand
Electric golf cart is a simple model electric vehicle (EV) with dependent charger up on the manufacturers. Using wireless EV charging technology for the e-golf cart is the stage to apply our wireless EV charger prototype for the simple model EV. The e-golf cart that used the 300 Ah 36V deep cycle lead-acid battery is used to be a sample. The wireless charging kits consist of 100 mm air-gap inductive wireless power primary and secondary coils, an 80 kHz 300 V, H-bridge inverter, primary side rectifier and constant current controlled dc-dc converter, and a secondary side rectifier. The results found that when primary rectified dc input voltage was 300V. The controlled battery current was 10A ±0.5A: the battery voltage was little varied in the range of 38 to 40 V. The load power varied in the range of 405 to 410 W, and the dc-dc efficiency of the system was varied in the field of 70 to 80 %.
- 1 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Tracking Wheel Test of Composite Insulator In 22kV Distribution System
The electrical insulator is an important part on stability of the power system. The defects of electrical insulators had a cause from a deterioration, which strongly affected on power system. According to this problem, this research aimed to study a characteristic of deterioration of composite insulators for power transmission 22 kV by designing and creating a standard test set IEC/TR 62730 under polluted conditions by wheel test and setting AC voltage 16.6 kV to electrodes by using Sodium Chloride as a polluted with conductivity 3.0 mS/cm. From the testing results showed that the heat from partial discharges on insulator surfaces was a main cause of leakage current and also affected on changing the surface of electrical insulators. As well, the corona discharge or the Dry band up could occur while testing and could be a result on reducing the insulator. The results of this study will be a method of testing Composite Insulator Type FXB-22/70, Rated Voltage 22kV According to the standard method, the test results will be evaluated to a certain level that This Composite insulators can be used in electrical systems.
- 1 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Tracking Wheel Test of Composite Insulator In 22kV Distribution System
The electrical insulator is an important part on stability of the power system. The defects of electrical insulators had a cause from a deterioration, which strongly affected on power system. According to this problem, this research aimed to study a characteristic of deterioration of composite insulators for power transmission 22 kV by designing and creating a standard test set IEC/TR 62730 under polluted conditions by wheel test and setting AC voltage 16.6 kV to electrodes by using Sodium Chloride as a polluted with conductivity 3.0 mS/cm. From the testing results showed that the heat from partial discharges on insulator surfaces was a main cause of leakage current and also affected on changing the surface of electrical insulators. As well, the corona discharge or the Dry band up could occur while testing and could be a result on reducing the insulator. The results of this study will be a method of testing Composite Insulator Type FXB-22/70, Rated Voltage 22kV According to the standard method, the test results will be evaluated to a certain level that This Composite insulators can be used in electrical systems.
- 8 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A comparison of asymmetrical control strategies for domestic induction cooking applications with low-quality factor loads
This paper presents a comparison of two control strategies between the fixed-frequency method and the variable-frequency method for output power control of a full-bridge resonant inverter in domestic induction cooking to address an issue of the distorted load current due to low-quality-factor load. The control strategies are based on the asymmetrical control using positive half-cycle control while operating under zero-voltage-switching (ZVS) and non-zero-voltage-switching (NON-ZVS) conditions. Load characteristics of different types of cooking materials are analyzed. The variable-frequency method can improve the inverter efficiency over all ranges of power compared with the fixed-frequency method due to reduction of the switching losses in the devices of inverter. The functionality and benefits of the proposed control strategies are verified through the experimental results.
- 8 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A comparison of asymmetrical control strategies for domestic induction cooking applications with low-quality factor loads
This paper presents a comparison of two control strategies between the fixed-frequency method and the variable-frequency method for output power control of a full-bridge resonant inverter in domestic induction cooking to address an issue of the distorted load current due to low-quality-factor load. The control strategies are based on the asymmetrical control using positive half-cycle control while operating under zero-voltage-switching (ZVS) and non-zero-voltage-switching (NON-ZVS) conditions. Load characteristics of different types of cooking materials are analyzed. The variable-frequency method can improve the inverter efficiency over all ranges of power compared with the fixed-frequency method due to reduction of the switching losses in the devices of inverter. The functionality and benefits of the proposed control strategies are verified through the experimental results.
- 20 March 2015
- Published by The Korean Institute of Power Electronics in Journal of Power Electronics
- Vol. 15 (2) , 544-554
Steady-State Analysis of ZVS and NON-ZVS Full-Bridge Inverters with Asymmetrical Control for Induction Heating Applications
- 20 March 2015
- Published by The Korean Institute of Power Electronics in Journal of Power Electronics
- Vol. 15 (2) , 544-554
Steady-State Analysis of ZVS and NON-ZVS Full-Bridge Inverters with Asymmetrical Control for Induction Heating Applications
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
The implementation of the full bridge inverter for the series resonant load
This paper presents the prototype of the series resonant inverter as the full-bridge inverter with the series resonant load as the induction cooking load for the electrical education laboratory of the faculty education of the RMUTT. The inverter is controlled by the microcontroller (MCU) as dsPIC30F2010 that it is three schemes of the gate-signal such as the vary frequency modulation (VFM), the asymmetrical duty cycle (ADC), and an asymmetrical voltage cancellation (AVC) schemes that all technique is to achieve the zero-voltage switching (ZVS) condition. The theory of three schemes can be confirmed by the experimental results.
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
The implementation of the full bridge inverter for the series resonant load
This paper presents the prototype of the series resonant inverter as the full-bridge inverter with the series resonant load as the induction cooking load for the electrical education laboratory of the faculty education of the RMUTT. The inverter is controlled by the microcontroller (MCU) as dsPIC30F2010 that it is three schemes of the gate-signal such as the vary frequency modulation (VFM), the asymmetrical duty cycle (ADC), and an asymmetrical voltage cancellation (AVC) schemes that all technique is to achieve the zero-voltage switching (ZVS) condition. The theory of three schemes can be confirmed by the experimental results.