Zufeng Xu
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zufeng Xu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Chaohai Zhang
Nanjing University of Aeronautics and Astronautics
1 shared publication - Han Chen
Jiangsu Key Lab of Remote Measurement and Control, School of Instrument Science and Engineering, Southeast University, Nanjing 210096, China
1 shared publication - Jiawen Xu
School of Instrument Science and Engineering, Southeast University, Nanjing, China
1 shared publication - Jie Lu
Department of Electrical Engineering, School of Automation, Nanjing University of Aeronautics and Astronautics, No. 29 Jiangjundadao Road, Nanjing 211106, China
1 shared publication - Li Chen
State Key Laboratory of Technology and Equipment for Defense Against Power System Operational Risks, Nanjing 211106, China
1 shared publication - Min Zhang
Nari Group Corporation
1 shared publication
Latest Publications
- Open Access
- 22 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (23) , 10805
A Multiple-Cantilever Piezoelectric Vibration Energy Harvester for Self-Powered CO2 Monitoring in Transformer Substations
The long-term CO2 emissions of transformer substations require constant monitoring. In this study, we propose a piezoelectric vibration energy harvester designed for self-powered CO2 monitoring of transformer substations. The proposed harvester comprises multiple slender piezoelectric cantilevers arranged in parallel, which results in a higher operational frequency and a significantly enhanced power output capability. Experimental investigations were conducted to assess the energy harvesting performance. The results show that the harvester can effectively capture the vibration energy, yielding an RMS power output of 2.99 mW, corresponding to the operational frequency of the transformer substation. Additionally, a wireless CO2 sensor node was developed, demonstrating an operational mechanism for CO2 monitoring. The capacitor takes approximately 1220 s to charge for the initial data measurement and transmission. The findings confirm that the energy harvester is capable of providing sufficient power to operate the sensor node for CO2 monitoring in transformer substations.
- 22 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (23) , 10805
Open AccessA Multiple-Cantilever Piezoelectric Vibration Energy Harvester for Self-Powered CO2 Monitoring in Transformer Substations
The long-term CO2 emissions of transformer substations require constant monitoring. In this study, we propose a piezoelectric vibration energy harvester designed for self-powered CO2 monitoring of transformer substations. The proposed harvester comprises multiple slender piezoelectric cantilevers arranged in parallel, which results in a higher operational frequency and a significantly enhanced power output capability. Experimental investigations were conducted to assess the energy harvesting performance. The results show that the harvester can effectively capture the vibration energy, yielding an RMS power output of 2.99 mW, corresponding to the operational frequency of the transformer substation. Additionally, a wireless CO2 sensor node was developed, demonstrating an operational mechanism for CO2 monitoring. The capacitor takes approximately 1220 s to charge for the initial data measurement and transmission. The findings confirm that the energy harvester is capable of providing sufficient power to operate the sensor node for CO2 monitoring in transformer substations.
- Open Access
An Improved Denoising Method for Fault Vibration Signals of Wind Turbine Gearbox Bearings
Vibration monitoring (VM) is an important tool for fault diagnosis in key components of wind turbine gearboxes (WTGs). However, due to the influence of white noise and random interference, it is difficult to realize high-quality denoising of WTG-VM signals. To overcome this limitation, a novel joint denoising method for fault WTG-VM signals is proposed in this article, which we have named EWTKC-SVD. First, the empirical wavelet transform (EWT) boundary exploration method is used to optimize frequency band allocation and obtain the multiple intrinsic mode functions (IMFs). Second, the sensitive IMFs are selected according to the calculated correlation coefficient and kurtosis index, avoiding IMF redundancy. Finally, the fault WTG-VM signals are obtained using SVD denoising. Using this approach, the proposed method realizes high-quality denoising of WTG-VM signals. Furthermore, it also effectively solves the existing problems of conventional methods, namely, inefficient IMF selection, high noise, false frequencies, mode mixing, and end effect. Finally, the effectiveness, superiority, and reliability of the proposed method are proved using simulation and practical case results.
Open AccessAn Improved Denoising Method for Fault Vibration Signals of Wind Turbine Gearbox Bearings
Vibration monitoring (VM) is an important tool for fault diagnosis in key components of wind turbine gearboxes (WTGs). However, due to the influence of white noise and random interference, it is difficult to realize high-quality denoising of WTG-VM signals. To overcome this limitation, a novel joint denoising method for fault WTG-VM signals is proposed in this article, which we have named EWTKC-SVD. First, the empirical wavelet transform (EWT) boundary exploration method is used to optimize frequency band allocation and obtain the multiple intrinsic mode functions (IMFs). Second, the sensitive IMFs are selected according to the calculated correlation coefficient and kurtosis index, avoiding IMF redundancy. Finally, the fault WTG-VM signals are obtained using SVD denoising. Using this approach, the proposed method realizes high-quality denoising of WTG-VM signals. Furthermore, it also effectively solves the existing problems of conventional methods, namely, inefficient IMF selection, high noise, false frequencies, mode mixing, and end effect. Finally, the effectiveness, superiority, and reliability of the proposed method are proved using simulation and practical case results.