Carlos Augusto Flores-Meneses
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Carlos Augusto Flores-Meneses has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Cruz Meneses-Fabian
Benemérita Universidad Autónoma de Puebla
5 shared publications - Maximino Avendaño-Alejo
Instituto de Ciencias Aplicadas y Tecnología, Universidad Nacional Autónoma de México, Cto. Exterior S/N, C.U.
4 shared publications - Ismael Velázquez-Gómez
Univ. Nacional Autónoma de México (Mexico)
2 shared publications - Martín Jiménez-Rodríguez
Univ Nacl Autonoma Mexico, Inst Ciencias Aplicadas & Tecnol, Apdo Postal 70-186, Mexico City 04510, Mexico
2 shared publications - Osvaldo Ponce-Hernández
Univ Nacl Autonoma Mexico, Inst Ciencias Aplicadas & Tecnol, Apdo Postal 70-186, Mexico City 04510, Mexico
2 shared publications Cruz Meneses-Fabian
1 shared publication
Latest Publications
- 30 October 2026
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 43 (11) , 2912
Input plane polarization modulation interferometry by direct normalization for phase retrieval
This paper introduces a novel, to our knowledge, interferometric method for robust wavefront phase retrieval. The technique is implemented using a double-aperture common-path interferometer (DACPI) incorporating two interchangeable input polarization masks. We demonstrate that each mask configuration enables the single-shot capture of three distinct interferograms, which are subsequently normalized to derive a closed-form analytical expression for thew phase reconstruction. Numerical simulations under ideal, noise-free conditions confirm that the proposed algorithm achieves exact phase recovery within the computational floating-point limit. The method’s reliability is further validated through a comprehensive sensitivity analysis, where it was subjected to various sources of experimental error and noise levels typically encountered in laboratory environments. Comparative numerical studies against established phase-shifting and self-calibrating algorithms demonstrate that the proposed technique exhibits high robustness and stability. Finally, experimental results are presented to provide full empirical validation of the system’s performance, establishing this approach as a highly efficient and noise-tolerant solution for phase reconstruction.
- 30 October 2026
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 43 (11) , 2912
Input plane polarization modulation interferometry by direct normalization for phase retrieval
This paper introduces a novel, to our knowledge, interferometric method for robust wavefront phase retrieval. The technique is implemented using a double-aperture common-path interferometer (DACPI) incorporating two interchangeable input polarization masks. We demonstrate that each mask configuration enables the single-shot capture of three distinct interferograms, which are subsequently normalized to derive a closed-form analytical expression for thew phase reconstruction. Numerical simulations under ideal, noise-free conditions confirm that the proposed algorithm achieves exact phase recovery within the computational floating-point limit. The method’s reliability is further validated through a comprehensive sensitivity analysis, where it was subjected to various sources of experimental error and noise levels typically encountered in laboratory environments. Comparative numerical studies against established phase-shifting and self-calibrating algorithms demonstrate that the proposed technique exhibits high robustness and stability. Finally, experimental results are presented to provide full empirical validation of the system’s performance, establishing this approach as a highly efficient and noise-tolerant solution for phase reconstruction.
- 19 October 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (30) , 10667
Analytical calculation of sagittal and tangential images produced by conic refracting interfaces, based on the study of caustic curves and Coddington equations
We study the formation of sagittal and tangential caustic curves produced by a conic refracting interface, considering an off-axis object point placed at an arbitrary position. By using both Coddington equations, we analytically give the location for the ideal image points. Additionally, we provide complete formulas that describe both sagittal and tangential caustic curves as a function of all parameters involved in the process of refraction as well as the position of the object point. Alternatively, considering both caustic curves, we study a new approach, to our knowledge, to properly locate the image points in both perpendicular planes, which are directly related to cuspid points. Finally, we present the exact and approximated equations for the sagittal and tangential caustic curves to reduce the astigmatism aberration at third order.
- 19 October 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (30) , 10667
Analytical calculation of sagittal and tangential images produced by conic refracting interfaces, based on the study of caustic curves and Coddington equations
We study the formation of sagittal and tangential caustic curves produced by a conic refracting interface, considering an off-axis object point placed at an arbitrary position. By using both Coddington equations, we analytically give the location for the ideal image points. Additionally, we provide complete formulas that describe both sagittal and tangential caustic curves as a function of all parameters involved in the process of refraction as well as the position of the object point. Alternatively, considering both caustic curves, we study a new approach, to our knowledge, to properly locate the image points in both perpendicular planes, which are directly related to cuspid points. Finally, we present the exact and approximated equations for the sagittal and tangential caustic curves to reduce the astigmatism aberration at third order.
- Open Access
- 1 September 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (35) , 355201
Dynamic phase retrieval by direct normalization with unknown phase-steps in phase-shifting interferometry
Dynamic phase measurement is essential across numerous scientific and technological domains for material characterization and specimen analysis. Among various methodologies, optical interferometry stands as a prominent technique for precise phase retrieval. This work presents a dynamic phase measurement approach based on phase-shifting interferometry, adapted for real-time phase monitoring. The technique is implemented in a double-aperture common-path interferometer configured for polarization modulation. The method enables simultaneous capture of two phase-shifted interferograms and two amplitude-modulated distributions within a single acquisition, from which the wavefront phase is successfully retrieved without requiring prior knowledge of the phase-step values. Numerical simulations incorporating typical experimental error sources validate the method’s robustness, achieving a maximum reconstruction accuracy of 97.42% under the combined influence of simulated noise variables. Furthermore, experimental results are presented alongside a quantitative evaluation of normalized interferogram profiles and extremum values, validating the system configuration through a custom-developed calibration interface.
- 1 September 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (35) , 355201
Open AccessDynamic phase retrieval by direct normalization with unknown phase-steps in phase-shifting interferometry
Dynamic phase measurement is essential across numerous scientific and technological domains for material characterization and specimen analysis. Among various methodologies, optical interferometry stands as a prominent technique for precise phase retrieval. This work presents a dynamic phase measurement approach based on phase-shifting interferometry, adapted for real-time phase monitoring. The technique is implemented in a double-aperture common-path interferometer configured for polarization modulation. The method enables simultaneous capture of two phase-shifted interferograms and two amplitude-modulated distributions within a single acquisition, from which the wavefront phase is successfully retrieved without requiring prior knowledge of the phase-step values. Numerical simulations incorporating typical experimental error sources validate the method’s robustness, achieving a maximum reconstruction accuracy of 97.42% under the combined influence of simulated noise variables. Furthermore, experimental results are presented alongside a quantitative evaluation of normalized interferogram profiles and extremum values, validating the system configuration through a custom-developed calibration interface.
- Open Access
- 17 September 2025
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 195
N-step self-calibrated generalized amplitude-phase-shifting interferometry
- 17 September 2025
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 195
Open AccessN-step self-calibrated generalized amplitude-phase-shifting interferometry
- Open Access
- 22 August 2024
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 183
Automated phase-visibility modulating interferometry
- 22 August 2024
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 183
Open AccessAutomated phase-visibility modulating interferometry
- 22 June 2024
- Published by Elsevier in Optics & Laser Technology
- Vol. 179
One-shot self-calibrating phase-shifting interferometry by direct normalization of interferograms
- 22 June 2024
- Published by Elsevier in Optics & Laser Technology
- Vol. 179
One-shot self-calibrating phase-shifting interferometry by direct normalization of interferograms
- 22 May 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (16) , 4310-4316
Generalized amplitude-phase-shifting interferometry
Recently, a novel technique was proposed for recovering the complex amplitude of an optical field from a set of interferograms modulated in both visibility and phase steps for the synchronous case, named amplitude-phase-shifting interferometry (APSI). This requirement leads to errors in the accuracy of phase recovery due to miscalibration or the nonlinear response of the device used to generate the phase steps; in the APSI case, these are polarizers. In this paper, we propose to create a generalized model of the APSI technique where the phase steps can be different from each other. APSI has been successfully implemented in a Mach–Zehnder interferometer, while the present technique has been deployed in a double-aperture common-path interferometer (DACPI). Additionally, it is demonstrated that in a DACPI, the use of experimental elements that may cause aberrations or extra noise in the experimental results is reduced. The aim is to have an even more robust phase and amplitude recovery technique, now named generalized amplitude-phase-shifting interferometry. Experimental results are presented and validated through a numerical noise study.
- 22 May 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (16) , 4310-4316
Generalized amplitude-phase-shifting interferometry
Recently, a novel technique was proposed for recovering the complex amplitude of an optical field from a set of interferograms modulated in both visibility and phase steps for the synchronous case, named amplitude-phase-shifting interferometry (APSI). This requirement leads to errors in the accuracy of phase recovery due to miscalibration or the nonlinear response of the device used to generate the phase steps; in the APSI case, these are polarizers. In this paper, we propose to create a generalized model of the APSI technique where the phase steps can be different from each other. APSI has been successfully implemented in a Mach–Zehnder interferometer, while the present technique has been deployed in a double-aperture common-path interferometer (DACPI). Additionally, it is demonstrated that in a DACPI, the use of experimental elements that may cause aberrations or extra noise in the experimental results is reduced. The aim is to have an even more robust phase and amplitude recovery technique, now named generalized amplitude-phase-shifting interferometry. Experimental results are presented and validated through a numerical noise study.
- 29 October 2023
- Published by Elsevier in Optics Communications
- Vol. 552
Complex amplitude extraction from a set of interferograms by simultaneous modulation of amplitude and phase steps
- 29 October 2023
- Published by Elsevier in Optics Communications
- Vol. 552
Complex amplitude extraction from a set of interferograms by simultaneous modulation of amplitude and phase steps