    ENERGY EFFICIENCY OF INTEGRATED HEAT SUPPLY AND HEAT GENERATION BASED ON IMPROVING THE INTERACTION BETWEEN THERMOTRANSFORMATIVE AND RECUPERATIVE PROCESSES

    by V.D. Petrash, V.P. Baryshev, A.A. Khomenko, A.V. Golubenko

    The study addresses the relevant problem of improving the efficiency of integrated heat supply systems for civil buildings and industrial enterprises. The proposed solution is based on two-stage heat generation with vapour-compression conversion of cooling energy flows, using the example of waste heat carrier from the heating network, cold water from the municipal network and waste gases. The objective of the work is to investigate the conditions for energy-efficient operation of the proposed system, based on a generalized relationship describing the coefficient of performance of the heat pump over the heating period. The analysis was carried out with variations in the temperatures of the considered low-grade heat sources, the ratio of cold water from the utility network flow to the flow rate of the spent energy carrier from the district heating network, water consumption for domestic and technological purposes, and exhaust gas flows from the heat-generating unit. It was substantiated that the variation of the coefficient of performance of the heat pump during the heating period is significantly influenced by the intermediate temperature of the spent heat carrier after the condenser at the inlet to the heat generator. Its rational value should be determined based on the calculated temperature difference between the spent heat carrier after the condenser and the evaporator of the heat pump. A new approach was proposed for studying system efficiency using advanced visualization in the form of 2D plots and 3D surfaces illustrating the interrelationships between output and operating parameters, as well as the results of the numerical and analytical analysis of the coefficient of performance function, including its first and second derivatives using the Hessian matrix. The identified rational values of the coefficient of performance of the heat pump are decisive in the engineering design of the system and necessary for its efficient control during operation, demonstrating potential improvements in energy efficiency of the proposed integrated heat supply system. Bibl. 33, Tab. 1, Fig. 7.

  • Open Access

    ЕФЕКТИВНІСТЬ ПАРОКОМПРЕСІЙНОГО ТЕПЛОПОСТАЧАННЯ В ЗМІННИХ УМОВАХ ВІДБОРУ ТА ВИКОРИСТАННЯ ТЕПЛОТИ

    by В. Д. Петраш, В. О. Макаров, A. A. Хоменко, А. В. Голубенко

    На основі утилізованої теплоти витяжного вентиляційного повітря та низькотемпературної енергії масиву ґрунту встановлена багатофакторна залежність визначення дійсного коефіцієнта перетворення теплонасосной установки, яка враховує зниження інтенсивності відбору теплового потоку внаслідок взаємодії температурного поля опускної та підйомної частин трубопроводів та ґрунтового масиву. Отримана залежність дає змогу проводити комплексну оцінку та аналіз енергетичної ефективності теплонасосної установки з по-шуком раціональних температурних і режимних параметрів за розрахункової потужності системи опалення та в експлуатаційному режимі її роботи з використанням додаткового джерела енергії. Також підтверджено позитивний вплив збільшення довжини трубопровідного контуру та кількості ґрунтових теплообмінників на зростання дійсного коефіцієнта перетворення теплонасосної установки як для розрахункових умов роботи системи опалення, так і в разі підвищення ефективності завдяки зростанню температури зовнішнього повітря протягом опалювального періоду.

  • Open Access

    POSSIBILITIES OF STEAM-COMPRESSION HEAT AND COOLING SUPPLY BASED ON ENERGY FROM A BINARY LOW-TEMPERATURE -SOURCE IN CONDITIONS OF REGULATED HEAT STORAG

    by V.D. Petrash, V.O. Makarov, O.I. Khomenko, A.V. Holubenko

    The article is devoted to the development of opportunities and conceptual foundations for improving heat pump-based heating systems, including the development of new technical solutions for the rational combined use of binary low-temperature heat sources to provide energy-efficient heating and cooling for residential buildings during the relevant seasons. The aim of this work is to improve the structural and functional design of the proposed heating and cooling supply system, providing a theoretical justification for the efficient utilisation of the energy potential of the binary heat exchange system utilising ground heat and ventilation air flows. The paper establishes the relationship between the output parameters in the process of vapour-compression heat extraction from a low-temperature source in the evaporator, in accordance with the established relationship, as well as the conditions of its consumption by user subsystems downstream of the condenser under operational control conditions, forms the basis for a multi-factor assessment of the energy potential of a binary low-temperature source and the subsequent determination of the energy efficiency of the vapour compression heating and cooling system under consideration. It has been established that in buildings with sufficient thermal energy resources in the ventilation air, the use of an improved heat pump system allows for a further extension of the period during which recovered heat is accumulated in the soil mass – at the beginning and end of the heating season. It has been demonstrated that the start of heat accumulation in the ground mass in buildings with a heat pump heating system can be achieved in regions of Ukraine where the outdoor air temperature equals its average value for the heating season. The graphical relationships obtained show that an increase in the flow rate of the heat transfer medium through the ground heat exchanger, resulting from a reduction in the cross-sectional area of the heat exchanger used to cool the ventilation air, significantly reduces the system’s energy efficiency across the range of characteristic changes in circulating flow rates - through the evaporator 1 and condenser 3 GВ/GК over the entire considered range of outdoor air temperature variation (0...-18)°C. It has also been established that high energy efficiency in the conversion of energy flows in the analysed system can be achieved even under design conditions for the heating period (tзовн. = -18°C) with a ratio of circulating energy flow rates through the evaporator and the GВ/GК condenser > 1.8, provided that heat consumption is predominantly for heating and ventilation processes. The performance characteristics of the improved system utilising integrated heat demonstrate enhanced efficiency in the conversion of energy flows for the heating and cooling of buildings, which indirectly justifies the feasibility of maximising the storage of excess heat from air flows in the ground, combined with the simultaneous cooling of buildings during the non-heating season. It follows that the use of integrated heat not only allows for the implementation of a combined or sequential process of general energy extraction, rationally coordinated with the optimal operational control regime of heat consumption systems, but also to ensure highly efficient accumulation of excess heat from a low-temperature source in the soil mass for its subsequent use during the heating season. Conclusions. For the proposed vapour-compression heating and cooling system for buildings, a multifactorial relationship has been established for the actual conversion coefficient used to assess the efficiency of transforming low-grade heat from the ground and ventilation air. This allows for the analysis of the individual influence of parameters and operating modes of structural subsystems in the search for optimal conditions for utilising the energy of integrated flows for heating and cooling buildings during the relevant periods of the year. It has been established that high energy efficiency of the system is ensured under design and operating conditions during the heating season with a specific ratio of circulating energy carriers through the evaporator and condenser of the heat pump equipment.

  • Open Access

    HEAT PUMP SYSTEM OF HOT WATER SUPPLY AND AIR COOLING BASED ON THE INTEGRATED ENERGY OF COLD WATER AND AIR FLOWS

    by V.D. Petrash, V.O. Makarov, A.A. Khomenko, A.S. Titlov, L.F. Shevchenko, A.V. Holubenko

    With the increasing cost of traditional fuel and energy resources all over the world, the problem of significantly increasing the efficiency of heating and cooling systems for buildings for various purposes with the improvement of environmental performance based on the use of new and improvement of traditional renewable and secondary low-temperature sources becomes relevant. Based on the results of the analysis of known developments of heat and cooling supply systems and methods of their calculation, the authors justified an improved version of the system in which the low-temperature source is source water, removed and supply ventilation air. The subsystem of two-level hot water supply with air cooling of premises in the warm period of the year of civil buildings located in the Southern regions of Ukraine was considered. On the basis of analytical study of heat and energy efficiency of the improved heat pump system of hot water supply and air cooling, the dependence of the actual conversion factor has been established, which represents a multifactor interrelation of initial and mode parameters, as well as modes of operation of structural subsystems of selection, conversion and subscriber heat consumption. Mode conditions are determined that ensure highly efficient heat recovery from cold water and ventilation air for hot water supply in the building and its cooling in the warm period of the year. The results of the analytical study have established the feasibility of using cold water and ventilation air as an integrated low-temperature source in the proposed system of heat and cold supply. The conversion efficiency of energy flows significantly exceeds similar values in traditionally applied systems, for example, with a characteristic low-potential source in the form of soil. Bibl. 25, Fig. 5.


  • Ефективність перетворення енергії від питомої витрати повітря у системі охолодження печі, що обертається, для теплопостачання

    by В.д. Петраш, О.і. Хоменко, Е.а. Гераскіна

    В роботі аналітично досліджується нова рекуперативно-трансформаторна система з переохолодженням рециркуляційного потоку охолодження печі, яка підвищує теплотехнологічну та енергетичну ефективність пічних агрегатів, розширюючи техніко-економічну ефективність промислового теплопостачання. Основу досліджень складає висновок, що дуже перспективним є застосування теплонасосних технологій для енергозбереження в процесах виробництва будівельних матеріалів у печах, що обертаються, з утилізацією низькотемпературних газоповітряних потоків. Зазначається, що стабілізація теплового режиму охолодження печі протягом року є важливим техніко-економічним завданням, спрямованим на покращення теплотехнічного процесу та енергозбереження, насамперед для зони випалу Проведено аналітичне дослідження рекуперативно-трансформаторної системи з переохолодженням рециркуляційного потоку. Представлено рівняння теплового балансу системи відбору теплоти газоповітряного контуру в процесі охолодження печі. Описана передача теплоти, сприйнятої з поверхні печі, в рекуперативних теплообмінниках, а також у випарнику термотрансформаторного контуру парокомпресійного теплового насоса. Отримана узагальнююча залежність для теплового потоку охолодження печі та низькопотенційного джерела у газоповітряному циркуляційному контурі системи теплопостачання. Визначена залежність для дійсного коефіцієнта перетворення в залежності від реальних значень зміни рециркуляційної частини теплоносія. Представлена графічна інтерпретація залежності дійсного коефіцієнта перетворення від співвідношення витрат гріючого теплоносія та середовища, що нагрівається. Наголошується, що результати дослідження раціонального взаємозв'язку вихідних і режимних параметрів створюють основу для інженерної розробки запропонованих систем теплопостачання на основі стабілізуючого охолодження печі, що обертається