BKByeol Kim

Byeol Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Byeol Kim has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Daiwon Jun

    Department of Plastic and Reconstructive Surgery, Bucheon St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea

    3 shared publications
  • Jung Ho Lee

    Department of Plastic and Reconstructive Surgery, Bucheon St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea

    3 shared publications
  • Hye Ju Han

    Department of Plastic and Reconstructive Surgery, Bucheon St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea

    1 shared publication
  • Ma Rhip Ahn

    Department of Plastic and Reconstructive Surgery, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea

    1 shared publication
  • Min Suk Park

    Department of Plastic and Reconstructive Surgery, Pusan National University School of Medicine, Busan, Korea

    1 shared publication

Latest Publications

  • Open Access

    Wound disruption after free flap reconstruction caused by a migrated calcaneal fragment: a case report

    by Dai Won Jun, Byeol Kim, Hye Ju Han, Jung Ho Lee

    Free-flap reconstruction is an established strategy for limb salvage in patients with diabetic heel ulcers. However, complications may occur even after technically successful surgery, particularly in the heel, where soft tissue coverage is limited and mechanical stress is concentrated. Here, we report two cases of wound dehiscence and partial flap necrosis following free anterolateral thigh flap reconstruction. In both cases, the complications resulted from displacement of previously unrecognized calcaneal fractures associated with diabetic bone insufficiency. The migrated fracture fragments exerted internal pressure on the overlying flaps, leading to wound dehiscence and prolonged healing. To our knowledge, this is the first report demonstrating that internal protrusion of a migrated bone fragment may represent a critical mechanism of flap failure. These cases underscore the importance of strict postoperative offloading, routine radiographic surveillance, and comprehensive patient education to reduce skeletal complications and improve outcomes after heel reconstruction.

  • Open Access

    Feasibility of a robotic exoscope in microsurgical diabetic foot reconstruction: a pilot study and narrative review

    by Byeol Kim, Jung Ho Lee, Daiwon Jun

    Purpose: This study aimed to assess the feasibility of a robotic exoscope (Robotic- Scope) for microvascular anastomosis in microsurgical diabetic-foot reconstruction compared with a conventional operating microscope, and to contextualize its use through a brief narrative review.Methods: This was a single-center, retrospective observational study of patients undergoing free tissue transfer for diabetic foot defects between August 2022 and January 2023. Patients were allocated according to the intraoperative visualization modality used: group A (robotic exoscope) or group B (operating microscope). The primary intraoperative variable was anastomosis time per vessel, while postoperative outcomes included flap survival and complications.Results: Six patients were included (five males; mean age, 53.17±12.73 years; mean defect size, 32.86±19.79 cm²), with two patients in group A and four in group B. The mean anastomosis time per vessel was 20.6±6.47 minutes in group A and 18.0±3.86 minutes in group B (p=0.342). All flaps in group A survived, while in group B, there was one case of partial flap necrosis and one instance of venous congestion requiring reexploration.Conclusion: In this pilot experience, a robotic exoscope enabled safe and efficient microvascular anastomosis for diabetic-foot free-flap reconstruction, with no significant difference in anastomosis time or early flap outcomes compared with the operating microscope. These findings support feasibility and justify larger, prospective studies to confirm efficacy, quantify ergonomic benefits, and refine clinical indications.

  • Open Access

    Novel Method of Split-Thickness Skin Graft Donor Site Management Using Combined Fenestrated Polyurethane Film and Negative-Pressure Wound Therapy

    by Daiwon Jun, Byeol Kim, Min Suk Park, Ma Rhip Ahn, Jung Ho Lee

    Background: Split-thickness skin graft (STSG) is a fundamental and versatile technique used in reconstructive surgery. Despite numerous studies addressing the management of STSG donor sites, there is still little consensus on the optimal dressing method. This study aimed to analyze the effectiveness of a novel method that combines a fenestrated polyurethane film with negative-pressure wound therapy (NPWT) over conventional moist dressings.Methods: Between January 2021 and December 2022, 23 patients who received STSG were retrospectively reviewed. In group A, a polyurethane film punctured with a 20-gauge needle was applied to the skin graft donor site. A NPWT system (CuraSys) was subsequently applied over the film. The conventional NPWT was replaced with a portable NPWT (PICO system) on the day of discharge. On the 14th postoperative day, the NPWT and film were removed. In group B, patients were administered a traditional moist dressing until epithelization. Postoperative pain, reepithelization rate, and dressing cost per cm² were compared.Results: Group A exhibited a lower mean pain score on all the measured days. Furthermore, group A demonstrated a significantly shorter time required for complete reepithelization (18.07±8.43 days vs. 28.20±5.25 days, P=0.003) and a lower dressing cost per square centimeter (6,517±6,162 KRW [4.82±4.56 USD] vs. 23,036±27,157 KRW [17.05±20.11 USD], P=0.006).Conclusion: The combination of fenestrated polyurethane film and NPWT resulted in reduced pain caused by dressing, a faster reepithelization rate, and lower dressing cost than that of conventional moist dressing.