Yongqing Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yongqing Wei has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Bao-Nian Wan
Chinese Academy of Sciences - Hefei Institutes of Physical Sciences
2 shared publications - Biao Shen
Institute of Plasma Physics, Chinese Academy of Sciences , Hefei 230031, Anhui, China
2 shared publications - Jin Zhang
Hefei University of Technology
2 shared publications - Lei Yang
School of Instrument Science and Opto-Electronics Engineering, Hefei University of Technology, Hefei 230009, China
2 shared publications - Ming Chen
Chinese Academy of Sciences, Institute of Plasma Physics, Hefei, China
2 shared publications - Dalong Chen
Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, People’s Republic of China
1 shared publication
Latest Publications
- 20 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
An Alternating Dynamic Drift-Compensated Integrator for 1000-s-Long Pulses in EAST
The Experimental Advanced Superconducting Tokamak (EAST) has achieved thousand-second plasma discharges, placing unprecedented demands on its Magnetic Diagnostic System (MDS). Conventional integrators, limited by saturation, excessive drift (>1% Full-Scale Range, FSR), and nonlinearity, fall short of the requirements for prolonged discharges. This paper presents a comprehensively optimized alternating integration system designed to overcome these limitations. Through rigorous numerically-driven analysis and quantification of error sources, tailored compensation strategies were derived and key operational parameters optimized, promoting error convergence and ensuring precision consistency for distributed deployment. Bench tests over 4000 seconds show that 99.04% of integration drift samples remain within 0.1% FSR, while plasma experiments confirm a maximum drift of only 9 mV during the 1,066-second discharge. The system operates autonomously, performing self-correction of drift induced by sensor load variations and self-calibration of drift rates during alternation cycles, thereby eliminating the need for manual intervention. Excellent reproducibility has been confirmed through repeated testing. This system delivers the precision performance surpassing the all-digital integrator developed for the International Thermonuclear Experimental Reactor (ITER) at a fraction of the cost. Suitable for deployment across EAST’s full magnetic diagnostic array of over 600 sensors, it not only meets the stringent requirements for long-pulse operation but also establishes a reliable foundation for the upcoming Burning Plasma Experiment Superconducting Tokamak (BEST) program.
- 20 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
An Alternating Dynamic Drift-Compensated Integrator for 1000-s-Long Pulses in EAST
The Experimental Advanced Superconducting Tokamak (EAST) has achieved thousand-second plasma discharges, placing unprecedented demands on its Magnetic Diagnostic System (MDS). Conventional integrators, limited by saturation, excessive drift (>1% Full-Scale Range, FSR), and nonlinearity, fall short of the requirements for prolonged discharges. This paper presents a comprehensively optimized alternating integration system designed to overcome these limitations. Through rigorous numerically-driven analysis and quantification of error sources, tailored compensation strategies were derived and key operational parameters optimized, promoting error convergence and ensuring precision consistency for distributed deployment. Bench tests over 4000 seconds show that 99.04% of integration drift samples remain within 0.1% FSR, while plasma experiments confirm a maximum drift of only 9 mV during the 1,066-second discharge. The system operates autonomously, performing self-correction of drift induced by sensor load variations and self-calibration of drift rates during alternation cycles, thereby eliminating the need for manual intervention. Excellent reproducibility has been confirmed through repeated testing. This system delivers the precision performance surpassing the all-digital integrator developed for the International Thermonuclear Experimental Reactor (ITER) at a fraction of the cost. Suitable for deployment across EAST’s full magnetic diagnostic array of over 600 sensors, it not only meets the stringent requirements for long-pulse operation but also establishes a reliable foundation for the upcoming Burning Plasma Experiment Superconducting Tokamak (BEST) program.
- 18 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Floating-Electrode-Based Microchip Enabling Multimodal Manipulation and Physical Parameters Measurement of Cells/Particles
Cells/particles manipulation has made significant strides in fields such as biomedical research, chemical analysis, and materials science, emerging as a crucial discipline. This paper introduces an innovative microchip featuring a wavy floating electrode structure, capable of multi-mode cells/particles manipulation. The floating-electrode-based microchip enabling different modal manipulation of cells/particles can be realized by simply adjusting the voltage and frequency parameters of the driving signal. Vortices can be generated at the edges of floating electrode in the low-frequency range of driving signal, orbital revolution of popular cells and out-of-plane rotation of single cells can be achieved by adjusting the voltage amplitude. The orbital revolution can be used for the enrichment of cells/particles, while the out-of-plane rotation provides the possibility to reconstruct the three-dimensional model of single cells and measure the physical parameters (ellipticity, surface area, volume). As the frequency increases, the dielectrophoretic forces gradually become dominant, enabling the effective separation of cells/particles with different electrical properties. The separation feasibility of the microchip was verified by the effective separation of particles and yeast cells. Through numerical simulation and experiments, the microchip is proved to have the advantages of simple structure, convenient operation, and multi-modal manipulation of cells/particles.
- 18 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Floating-Electrode-Based Microchip Enabling Multimodal Manipulation and Physical Parameters Measurement of Cells/Particles
Cells/particles manipulation has made significant strides in fields such as biomedical research, chemical analysis, and materials science, emerging as a crucial discipline. This paper introduces an innovative microchip featuring a wavy floating electrode structure, capable of multi-mode cells/particles manipulation. The floating-electrode-based microchip enabling different modal manipulation of cells/particles can be realized by simply adjusting the voltage and frequency parameters of the driving signal. Vortices can be generated at the edges of floating electrode in the low-frequency range of driving signal, orbital revolution of popular cells and out-of-plane rotation of single cells can be achieved by adjusting the voltage amplitude. The orbital revolution can be used for the enrichment of cells/particles, while the out-of-plane rotation provides the possibility to reconstruct the three-dimensional model of single cells and measure the physical parameters (ellipticity, surface area, volume). As the frequency increases, the dielectrophoretic forces gradually become dominant, enabling the effective separation of cells/particles with different electrical properties. The separation feasibility of the microchip was verified by the effective separation of particles and yeast cells. Through numerical simulation and experiments, the microchip is proved to have the advantages of simple structure, convenient operation, and multi-modal manipulation of cells/particles.
- Open Access
- 1 November 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (11)
An alternating continuous integration system for magnetic measurements for experimental advanced superconducting tokamak
Integrators are critical instruments used for magnetic measurement systems (MMSs) in tokamaks, and, currently, the Experimental Advanced Superconducting Tokamak (EAST) has over 600 deployed. However, these integrators, designed with real-time drift compensation, will not be able to support longer pulse operations in the near future due to saturation and drift. To address these issues, this paper proposes a new alternating integration system combining analog integration with drift digital rectification. This system utilizes a microcontroller unit (MCU) to control two parallel analog integrators to work alternatively, compensate their drifts based on their respective error characteristics, and assemble the two integration segments together. The designed architecture provides highly flexible capabilities in operation modes and error correction, which make the system operation and maintenance highly automated. Performance tests on the EAST experiment site show that the prototype integrator can meet the requirements of real-time plasma control for a duration of hour-level.
- 1 November 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (11)
Open AccessAn alternating continuous integration system for magnetic measurements for experimental advanced superconducting tokamak
Integrators are critical instruments used for magnetic measurement systems (MMSs) in tokamaks, and, currently, the Experimental Advanced Superconducting Tokamak (EAST) has over 600 deployed. However, these integrators, designed with real-time drift compensation, will not be able to support longer pulse operations in the near future due to saturation and drift. To address these issues, this paper proposes a new alternating integration system combining analog integration with drift digital rectification. This system utilizes a microcontroller unit (MCU) to control two parallel analog integrators to work alternatively, compensate their drifts based on their respective error characteristics, and assemble the two integration segments together. The designed architecture provides highly flexible capabilities in operation modes and error correction, which make the system operation and maintenance highly automated. Performance tests on the EAST experiment site show that the prototype integrator can meet the requirements of real-time plasma control for a duration of hour-level.