Tingting Su
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tingting Su has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Guangping He
Department of Mechanical and Electrical Engineering, North China University of Technology, Beijing, China
1 shared publication - Haojian Zhang
Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China
1 shared publication Jinghao Zhang
University of Shanghai for Science and Technology
1 shared publication- Quan Yuan
North China University of Technology Department of Mechanical and Materials Engineering Beijing 100144 , China
1 shared publication - Quanliang Zhao
School of Mechanical and Materials Engineering North China University of Technology Beijing China
1 shared publication Shengda Liu
Institute of Automation, , Beijing, China
1 shared publication
Latest Publications
- 2 September 2026
- Published by Springer Nature
- p. 97-107
Mamba-Based Human Movement Intention Prediction Network with Multimodal Information Integration
- 2 September 2026
- Published by Springer Nature
- p. 97-107
Mamba-Based Human Movement Intention Prediction Network with Multimodal Information Integration
- Open Access
- 16 May 2024
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 12, 1392599
Multi-mode adaptive control strategy for a lower limb rehabilitation robot
Different patients have different rehabilitation requirements. It is essential to ensure the safety and comfort of patients at different recovery stages during rehabilitation training. This study proposes a multi-mode adaptive control method to achieve a safe and compliant rehabilitation training strategy. First, patients’ motion intention and motor ability are evaluated based on the average human–robot interaction force per task cycle. Second, three kinds of rehabilitation training modes—robot-dominant, patient-dominant, and safety-stop—are established, and the adaptive controller can dexterously switch between the three training modes. In the robot-dominant mode, based on the motion errors, the patient’s motor ability, and motion intention, the controller can adaptively adjust its assistance level and impedance parameters to help patients complete rehabilitation tasks and encourage them to actively participate. In the patient-dominant mode, the controller only adjusts the training speed. When the trajectory error is too large, the controller switches to the safety-stop mode to ensure patient safety. The stabilities of the adaptive controller under three training modes are then proven using Lyapunov theory. Finally, the effectiveness of the multi-mode adaptive controller is verified by simulation results.
- 16 May 2024
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 12, 1392599
Open AccessMulti-mode adaptive control strategy for a lower limb rehabilitation robot
Different patients have different rehabilitation requirements. It is essential to ensure the safety and comfort of patients at different recovery stages during rehabilitation training. This study proposes a multi-mode adaptive control method to achieve a safe and compliant rehabilitation training strategy. First, patients’ motion intention and motor ability are evaluated based on the average human–robot interaction force per task cycle. Second, three kinds of rehabilitation training modes—robot-dominant, patient-dominant, and safety-stop—are established, and the adaptive controller can dexterously switch between the three training modes. In the robot-dominant mode, based on the motion errors, the patient’s motor ability, and motion intention, the controller can adaptively adjust its assistance level and impedance parameters to help patients complete rehabilitation tasks and encourage them to actively participate. In the patient-dominant mode, the controller only adjusts the training speed. When the trajectory error is too large, the controller switches to the safety-stop mode to ensure patient safety. The stabilities of the adaptive controller under three training modes are then proven using Lyapunov theory. Finally, the effectiveness of the multi-mode adaptive controller is verified by simulation results.
- 11 December 2023
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 16 (8) , 1-16
Design and Analysis of a Novel Redundant Parallel Mechanism for Long Bone Fracture Reduction
In recent years, parallel robots have become a hot research topic in trauma fracture treatment because of their high precision, high load capacity, and compact structure. However, parallel robots have disadvantages like small workspaces and complex singularity. In this article, a novel redundant parallel mechanism (RPM) for long bone fracture reduction is proposed based on Stewart parallel mechanism (SPM). Six kinematically redundant DOFs (degrees-of-freedom) are added to the RPM. First, the kinematics of the RPM is established, and its workspace is calculated. The analysis results indicate that the position workspace of the RPM is about 19 times larger than that of the SPM. The RPM has a similar range of torsion angles as the SPM, but a more extensive range of tilt angles than the SPM. Second, the singularities of the two parallel mechanisms are compared based on the dimensionally homogeneous Jacobian matrix. The results show that the dexterity of the RPM is much better than the SPM. Third, a multiparameter multi-objective optimization method is proposed to optimize the geometry parameters of the RPM. The statics of the RPM is analyzed by finite element analysis. To further expand the performance of the RPM, the unfixed RPM (URPM) is proposed. The analysis results show that the URPM is superior to the RPM in terms of workspace and dexterity. Finally, experiments are conducted to verify the effectiveness of the proposed methods in this article.
- 11 December 2023
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 16 (8) , 1-16
Design and Analysis of a Novel Redundant Parallel Mechanism for Long Bone Fracture Reduction
In recent years, parallel robots have become a hot research topic in trauma fracture treatment because of their high precision, high load capacity, and compact structure. However, parallel robots have disadvantages like small workspaces and complex singularity. In this article, a novel redundant parallel mechanism (RPM) for long bone fracture reduction is proposed based on Stewart parallel mechanism (SPM). Six kinematically redundant DOFs (degrees-of-freedom) are added to the RPM. First, the kinematics of the RPM is established, and its workspace is calculated. The analysis results indicate that the position workspace of the RPM is about 19 times larger than that of the SPM. The RPM has a similar range of torsion angles as the SPM, but a more extensive range of tilt angles than the SPM. Second, the singularities of the two parallel mechanisms are compared based on the dimensionally homogeneous Jacobian matrix. The results show that the dexterity of the RPM is much better than the SPM. Third, a multiparameter multi-objective optimization method is proposed to optimize the geometry parameters of the RPM. The statics of the RPM is analyzed by finite element analysis. To further expand the performance of the RPM, the unfixed RPM (URPM) is proposed. The analysis results show that the URPM is superior to the RPM in terms of workspace and dexterity. Finally, experiments are conducted to verify the effectiveness of the proposed methods in this article.