Xueqin Ji
Xueqin Ji has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Yuan Zhao
Peking University First Hospital Ningxia Women and Children’s Hospital (Ningxia Hui Autonomous Region Maternal and Child Health Hospital), Yinchuan, China
6 shared publicationsSihan Fan
Ningxia Medical University, Yinchuan, Ningxia 750004, China
5 shared publicationsYan Xia
Department of Ultrasound Medicine, Peking University First Hospital Ningxia Women and Children’s Hospital (Ningxia Hui Autonomous Region Maternal and Child Health Hospital)
5 shared publications- Xinrong Chen
Fudan University
4 shared publications Fang Tan
Ningxia Medical University
3 shared publicationsJiaojiao Yang
Ningxia Medical University
3 shared publications
Latest Publications
- Open Access
- 18 September 2026
- Published by Springer Nature in Archives of Gynecology and Obstetrics
The ALDW classification for fetal insular morphology: gestational norms and screening utility
- 18 September 2026
- Published by Springer Nature in Archives of Gynecology and Obstetrics
Open AccessThe ALDW classification for fetal insular morphology: gestational norms and screening utility
- Open Access
- 9 July 2026
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 14, 1888687
uFlowAM: an unsupervised framework for detection and visualization of abnormal intracardiac microflow on early-pregnancy fetal cardiac microflow imaging
Background: Congenital heart disease (CHD) is a clinically important fetal anomaly. Early-pregnancy fetal cardiac microflow imaging (FCMI) can show low-velocity intracardiac flow, but brief shunt-related, regurgitant, and outflow-tract disturbances remain difficult to recognize when image quality, fetal position, and gestational age vary across examinations. Objective: To evaluate uFlowAM for fetus-level detection and visualization of abnormal intracardiac microflow patterns on early-pregnancy FCMI. Methods: This multicenter diagnostic accuracy study analyzed 650 early-pregnancy FCMI examinations from fetuses referred for suspected CHD or CHD risk assessment, including 500 examinations in the internal cohort and 150 in the external cohort. Standard four-chamber, left ventricular outflow tract (LVOT), and right ventricular outflow tract (RVOT) clips were processed by microflow extraction, cardiac-cycle alignment, signal normalization, and 16-frame windowing. uFlowAM used self-supervised training to learn a 256-dimensional representation of control fetal microflow from temporal-order discrimination and masked-frame reconstruction. Model training used no pixel-level or lesion-level labels. Control embeddings were grouped by view and cardiac phase to build a normal microflow template library, and an abnormality index (AbI) was calculated from latent-space Mahalanobis distances. The operating threshold was calibrated in internal validation and then kept fixed for external testing. Clinical utility was assessed in a 9-reader, 240-case multi-reader multi-case (MRMC) study. Results: Using the fixed operating threshold ( τ * = 2.15), uFlowAM achieved an area under the receiver operating characteristic curve (AUC) of 0.94 (95% CI, 0.92–0.96), sensitivity of 0.92, and specificity of 0.88 in the internal cohort. In the external cohort, AUC was 0.92 (95% CI, 0.88–0.95), with sensitivity of 0.90 and specificity of 0.86. Median reader-level AUC increased from 0.85 to 0.92 with uFlowAM assistance, weighted kappa for subtype agreement increased from 0.62 to 0.78, visibility scores increased from 2.8 ± 0.6 to 4.3 ± 0.5, and median reading time decreased from 78 s to 59 s. Mean inference time was 6.8 ± 1.3 s per case. Conclusions: In this CHD-enriched referral/risk-assessment cohort, uFlowAM detected abnormal early-pregnancy fetal cardiac microflow patterns and improved reader consistency and efficiency on selected fetal cardiac microflow views. The framework should be considered an assistive second-reader tool for early fetal CHD assessment. It should not be used as a substitute for a complete fetal echocardiographic examination.
- 9 July 2026
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 14, 1888687
Open AccessuFlowAM: an unsupervised framework for detection and visualization of abnormal intracardiac microflow on early-pregnancy fetal cardiac microflow imaging
Background: Congenital heart disease (CHD) is a clinically important fetal anomaly. Early-pregnancy fetal cardiac microflow imaging (FCMI) can show low-velocity intracardiac flow, but brief shunt-related, regurgitant, and outflow-tract disturbances remain difficult to recognize when image quality, fetal position, and gestational age vary across examinations. Objective: To evaluate uFlowAM for fetus-level detection and visualization of abnormal intracardiac microflow patterns on early-pregnancy FCMI. Methods: This multicenter diagnostic accuracy study analyzed 650 early-pregnancy FCMI examinations from fetuses referred for suspected CHD or CHD risk assessment, including 500 examinations in the internal cohort and 150 in the external cohort. Standard four-chamber, left ventricular outflow tract (LVOT), and right ventricular outflow tract (RVOT) clips were processed by microflow extraction, cardiac-cycle alignment, signal normalization, and 16-frame windowing. uFlowAM used self-supervised training to learn a 256-dimensional representation of control fetal microflow from temporal-order discrimination and masked-frame reconstruction. Model training used no pixel-level or lesion-level labels. Control embeddings were grouped by view and cardiac phase to build a normal microflow template library, and an abnormality index (AbI) was calculated from latent-space Mahalanobis distances. The operating threshold was calibrated in internal validation and then kept fixed for external testing. Clinical utility was assessed in a 9-reader, 240-case multi-reader multi-case (MRMC) study. Results: Using the fixed operating threshold ( τ * = 2.15), uFlowAM achieved an area under the receiver operating characteristic curve (AUC) of 0.94 (95% CI, 0.92–0.96), sensitivity of 0.92, and specificity of 0.88 in the internal cohort. In the external cohort, AUC was 0.92 (95% CI, 0.88–0.95), with sensitivity of 0.90 and specificity of 0.86. Median reader-level AUC increased from 0.85 to 0.92 with uFlowAM assistance, weighted kappa for subtype agreement increased from 0.62 to 0.78, visibility scores increased from 2.8 ± 0.6 to 4.3 ± 0.5, and median reading time decreased from 78 s to 59 s. Mean inference time was 6.8 ± 1.3 s per case. Conclusions: In this CHD-enriched referral/risk-assessment cohort, uFlowAM detected abnormal early-pregnancy fetal cardiac microflow patterns and improved reader consistency and efficiency on selected fetal cardiac microflow views. The framework should be considered an assistive second-reader tool for early fetal CHD assessment. It should not be used as a substitute for a complete fetal echocardiographic examination.
- Open Access
- 30 September 2025
- Published by Journal of Internet Technology in 網際網路技術學刊
- Vol. 26 (5) , 607-616
Diagnosis of Fetal Congenital Heart Disease Based on Deep Learning
Fetal congenital heart disease is the most common birth defect. In early diagnosis, the use of echocardiography is an important means of diagnosis, but due to the unique structure of the fetal heart, there are still many challenges in the early screening process. Hence, this study proposes a diagnosis model called ConvNeXt based on Attention Mechanism and Transfer Learning (ConvNeXt-AMTL) for congenital heart disease, which utilizes a large-kernel convolutional neural network to extract features from fetal echocardiography, and using attention mechanisms to focus and optimize key features. At the same time, in order to alleviate the problem that image data samples are too few to train the model well, this study proposes to use transfer learning to train the model. Numerous experiments have shown that the proposed model can efficiently diagnose fetal congenital heart disease, achieving an accuracy of 98.8% on the test set, effectively promoting prenatal screening of fetal congenital heart disease.
- 30 September 2025
- Published by Journal of Internet Technology in 網際網路技術學刊
- Vol. 26 (5) , 607-616
Open AccessDiagnosis of Fetal Congenital Heart Disease Based on Deep Learning
Fetal congenital heart disease is the most common birth defect. In early diagnosis, the use of echocardiography is an important means of diagnosis, but due to the unique structure of the fetal heart, there are still many challenges in the early screening process. Hence, this study proposes a diagnosis model called ConvNeXt based on Attention Mechanism and Transfer Learning (ConvNeXt-AMTL) for congenital heart disease, which utilizes a large-kernel convolutional neural network to extract features from fetal echocardiography, and using attention mechanisms to focus and optimize key features. At the same time, in order to alleviate the problem that image data samples are too few to train the model well, this study proposes to use transfer learning to train the model. Numerous experiments have shown that the proposed model can efficiently diagnose fetal congenital heart disease, achieving an accuracy of 98.8% on the test set, effectively promoting prenatal screening of fetal congenital heart disease.
- Open Access
- 11 April 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (4) , 407
IDNet: A Diffusion Model-Enhanced Framework for Accurate Cranio-Maxillofacial Bone Defect Repair
Cranio-maxillofacial bone defect repair poses significant challenges in oral and maxillofacial surgery due to the complex anatomy of the region and its substantial impact on patients’ physiological function, aesthetic appearance, and quality of life. Inaccurate reconstruction can result in serious complications, including functional impairment and psychological trauma. Traditional methods have notable limitations for complex defects, underscoring the need for advanced computational approaches to achieve high-precision personalized reconstruction. This study presents the Internal Diffusion Network (IDNet), a novel framework that integrates a diffusion model into a standard U-shaped network to extract valuable information from input data and produce high-resolution representations for 3D medical segmentation. A Step-Uncertainty Fusion module was designed to enhance prediction robustness by combining diffusion model outputs at each inference step. The model was evaluated on a dataset consisting of 125 normal human skull 3D reconstructions and 2625 simulated cranio-maxillofacial bone defects. Quantitative evaluation revealed that IDNet outperformed mainstream methods, including UNETR and 3D U-Net, across key metrics: Dice Similarity Coefficient (DSC), True Positive Rate (RECALL), and 95th percentile Hausdorff Distance (HD95). The approach achieved an average DSC of 0.8140, RECALL of 0.8554, and HD95 of 4.35 mm across seven defect types, substantially surpassing comparison methods. This study demonstrates the significant performance advantages of diffusion model-based approaches in cranio-maxillofacial bone defect repair, with potential implications for increasing repair surgery success rates and patient satisfaction in clinical applications.
- 11 April 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (4) , 407
Open AccessIDNet: A Diffusion Model-Enhanced Framework for Accurate Cranio-Maxillofacial Bone Defect Repair
Cranio-maxillofacial bone defect repair poses significant challenges in oral and maxillofacial surgery due to the complex anatomy of the region and its substantial impact on patients’ physiological function, aesthetic appearance, and quality of life. Inaccurate reconstruction can result in serious complications, including functional impairment and psychological trauma. Traditional methods have notable limitations for complex defects, underscoring the need for advanced computational approaches to achieve high-precision personalized reconstruction. This study presents the Internal Diffusion Network (IDNet), a novel framework that integrates a diffusion model into a standard U-shaped network to extract valuable information from input data and produce high-resolution representations for 3D medical segmentation. A Step-Uncertainty Fusion module was designed to enhance prediction robustness by combining diffusion model outputs at each inference step. The model was evaluated on a dataset consisting of 125 normal human skull 3D reconstructions and 2625 simulated cranio-maxillofacial bone defects. Quantitative evaluation revealed that IDNet outperformed mainstream methods, including UNETR and 3D U-Net, across key metrics: Dice Similarity Coefficient (DSC), True Positive Rate (RECALL), and 95th percentile Hausdorff Distance (HD95). The approach achieved an average DSC of 0.8140, RECALL of 0.8554, and HD95 of 4.35 mm across seven defect types, substantially surpassing comparison methods. This study demonstrates the significant performance advantages of diffusion model-based approaches in cranio-maxillofacial bone defect repair, with potential implications for increasing repair surgery success rates and patient satisfaction in clinical applications.
- Open Access
- 3 July 2024
- Published by Wolters Kluwer Health in Maternal-Fetal Medicine
- Vol. 6 (3) , 147-155
Assessing Coarctation of the Aorta With Fetal Heart Quantification Technology
Objective: To use fetal heart quantification (fetal HQ) technology to compare the coarctation of the aorta (CoA) and normal fetal heart structure and systolic function and to assess whether there are abnormalities in the fetal heart structure and systolic function associated with CoA. Methods: This prospective cohort study was conducted from May 2020 to December 2022 and involved 18–40-week-old singleton pregnancies and 30 fetuses diagnosed with CoA using fetal echocardiography at the General Hospital of Ningxia Medical University and Peking University First Hospital Ningxia Women’s and Children’s Hospital, China. The control group contained 60 normal fetuses. The following parameters were recorded and analyzed statistically: four-chamber view (4CV) end-diastolic long diameter, 4CV epicardial–contralateral epicardial transverse maximum diameter, 4CV global sphericity index (GSI), left ventricular (LV) and right ventricular (RV) 24-segment end-diastolic diameter (EDD), 24-segment sphericity index (SI), LV-fractional area change (LV-FAC), LV-longitudinal strain (LV-LS), RV-fractional area change (RV-FAC), RV-longitudinal strain (RV-LS), and LV and RV 24-segment transverse fractional shortening (FS). Measurement data were compared between the two groups using an independent sample t test, with P < 0.05 indicating statistically significant differences. Moreover, the correlation between gestational age and GSI, LV-FAC, LV-LS, RV-FAC, and RV-LS was assessed. Results: Within and between observer comparisons of the parameters associated with major cardiac function revealed an intragroup correlation coefficient of >0.9, indicating high consistency, and a coefficient of variable of P < 0.05). A comparison of the LV and RV morphological structure parameters between the two groups revealed that when compared with the control group, the LV’s 24-segment EDD was smaller in the CoA group, the RV’s 24-segment EDD was greater in the control group, the SI of the LV’s segments 16–24 was greater than in the control group, and the SI of the RV’s segments 7–24 was less than in the control group (all P < 0.05). When compared with fetuses in the control group, the LV’s segments 16–24 were greater in the CoA group, whereas the RV’s segment 6–24 was smaller (P < 0.05). When compared with the control group, LV-FAC, RV-FAC, and LS were lower in the CoA group (P < 0.05). The FS of the LV segments 1–24 and the FS of the RV segments 1–16 were smaller in the CoA group than in the normal group (P < 0.05). Conclusion: Fetal HQ, a new simple technique that offers rapid analysis and high repeatability, can quantitatively evaluate structural and systolic function changes in fetuses with CoA.
- 3 July 2024
- Published by Wolters Kluwer Health in Maternal-Fetal Medicine
- Vol. 6 (3) , 147-155
Open AccessAssessing Coarctation of the Aorta With Fetal Heart Quantification Technology
Objective: To use fetal heart quantification (fetal HQ) technology to compare the coarctation of the aorta (CoA) and normal fetal heart structure and systolic function and to assess whether there are abnormalities in the fetal heart structure and systolic function associated with CoA. Methods: This prospective cohort study was conducted from May 2020 to December 2022 and involved 18–40-week-old singleton pregnancies and 30 fetuses diagnosed with CoA using fetal echocardiography at the General Hospital of Ningxia Medical University and Peking University First Hospital Ningxia Women’s and Children’s Hospital, China. The control group contained 60 normal fetuses. The following parameters were recorded and analyzed statistically: four-chamber view (4CV) end-diastolic long diameter, 4CV epicardial–contralateral epicardial transverse maximum diameter, 4CV global sphericity index (GSI), left ventricular (LV) and right ventricular (RV) 24-segment end-diastolic diameter (EDD), 24-segment sphericity index (SI), LV-fractional area change (LV-FAC), LV-longitudinal strain (LV-LS), RV-fractional area change (RV-FAC), RV-longitudinal strain (RV-LS), and LV and RV 24-segment transverse fractional shortening (FS). Measurement data were compared between the two groups using an independent sample t test, with P < 0.05 indicating statistically significant differences. Moreover, the correlation between gestational age and GSI, LV-FAC, LV-LS, RV-FAC, and RV-LS was assessed. Results: Within and between observer comparisons of the parameters associated with major cardiac function revealed an intragroup correlation coefficient of >0.9, indicating high consistency, and a coefficient of variable of P < 0.05). A comparison of the LV and RV morphological structure parameters between the two groups revealed that when compared with the control group, the LV’s 24-segment EDD was smaller in the CoA group, the RV’s 24-segment EDD was greater in the control group, the SI of the LV’s segments 16–24 was greater than in the control group, and the SI of the RV’s segments 7–24 was less than in the control group (all P < 0.05). When compared with fetuses in the control group, the LV’s segments 16–24 were greater in the CoA group, whereas the RV’s segment 6–24 was smaller (P < 0.05). When compared with the control group, LV-FAC, RV-FAC, and LS were lower in the CoA group (P < 0.05). The FS of the LV segments 1–24 and the FS of the RV segments 1–16 were smaller in the CoA group than in the normal group (P < 0.05). Conclusion: Fetal HQ, a new simple technique that offers rapid analysis and high repeatability, can quantitatively evaluate structural and systolic function changes in fetuses with CoA.
- 26 October 2023
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 23 (09)
AUGMENTED REALITY-BASED NASAL ENDOSCOPE VIDEO RECONSTRUCTION AND REGISTRATION
Neuroendoscopic surgery is a minimally invasive surgical technique commonly used to remove a tumor through the patient’s mouth or nose, which requires the surgeon to avoid important neural and vascular structures. Augmented reality-based surgical navigation can provide surgeons with more information and visual aids, clarifying the structure and details of the surgical area. It requires real-time registration of intraoperative endoscopic video with pre-operative CT models. However, 3D reconstruction and camera tracking from nasal endoscopic video are challenging due to the narrow nasal cavity and the lack of texture. Besides, the nasal endoscopic datasets that can be used for deep learning-based depth estimation are scarce and hard to elaborate. To this end, a style-augmented module (SAM) is proposed in this study to minimize discrepancies between different endoscopic datasets. An unsupervised approach was trained to generate depth maps and camera motion paths, which were used to reconstruct the nasal scene’s 3D model. The obtained reconstruction was aligned with a pre-operative CT model for augmented reality-based surgical navigation. The results showed that the proposed SAM improved the generalization of the depth estimation model on nasal endoscopy data. The proposed approach to combining augmented reality technology with surgical navigation is considered instrumental in furnishing surgeons with richer information on the nasal endoscopic surgical scene.
- 26 October 2023
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 23 (09)
AUGMENTED REALITY-BASED NASAL ENDOSCOPE VIDEO RECONSTRUCTION AND REGISTRATION
Neuroendoscopic surgery is a minimally invasive surgical technique commonly used to remove a tumor through the patient’s mouth or nose, which requires the surgeon to avoid important neural and vascular structures. Augmented reality-based surgical navigation can provide surgeons with more information and visual aids, clarifying the structure and details of the surgical area. It requires real-time registration of intraoperative endoscopic video with pre-operative CT models. However, 3D reconstruction and camera tracking from nasal endoscopic video are challenging due to the narrow nasal cavity and the lack of texture. Besides, the nasal endoscopic datasets that can be used for deep learning-based depth estimation are scarce and hard to elaborate. To this end, a style-augmented module (SAM) is proposed in this study to minimize discrepancies between different endoscopic datasets. An unsupervised approach was trained to generate depth maps and camera motion paths, which were used to reconstruct the nasal scene’s 3D model. The obtained reconstruction was aligned with a pre-operative CT model for augmented reality-based surgical navigation. The results showed that the proposed SAM improved the generalization of the depth estimation model on nasal endoscopy data. The proposed approach to combining augmented reality technology with surgical navigation is considered instrumental in furnishing surgeons with richer information on the nasal endoscopic surgical scene.
- 5 September 2023
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 23 (08)
ARTIFICIAL INTELLIGENCE-BASED FETAL CONGENITAL HEART DISEASE DIAGNOSTICS: A SURVEY OF STATE-OF-THE-ART TECHNIQUES
With the development of computer technology and neural networks, artificial intelligence (AI) has become sufficiently mature to assist in various technical and medical tasks, including the prenatal diagnosis of congenital heart disease (CHD). Moreover, the AI-based approach to solving this challenge has provided new ideas, concepts, and techniques. This review focuses on fetal CHD and conventional methods of its diagnostics, highlights the main achievements and particular techniques of AI application to CHD diagnostics, and discusses their advantages, drawbacks, and ways of further improvement regarding CHD and other heart disease.
- 5 September 2023
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 23 (08)
ARTIFICIAL INTELLIGENCE-BASED FETAL CONGENITAL HEART DISEASE DIAGNOSTICS: A SURVEY OF STATE-OF-THE-ART TECHNIQUES
With the development of computer technology and neural networks, artificial intelligence (AI) has become sufficiently mature to assist in various technical and medical tasks, including the prenatal diagnosis of congenital heart disease (CHD). Moreover, the AI-based approach to solving this challenge has provided new ideas, concepts, and techniques. This review focuses on fetal CHD and conventional methods of its diagnostics, highlights the main achievements and particular techniques of AI application to CHD diagnostics, and discusses their advantages, drawbacks, and ways of further improvement regarding CHD and other heart disease.
- Open Access
- 6 January 2023
- Published by Springer Nature in Research Square
Preliminary study of fetal HQ in cardiac structure and systolic function of fetal Coarctation of the aorta
Objective To use fetal HQ software to carry out quantitative analysis of the 4-chamber view (4-CV) and left and right ventricle of fetuses with Coarctation of aortic(CoA) and normal fetuses, and to explore the application value of this software in evaluating the cardiac structure and systolic function of fetuses with CoA. Methods fetal HQ software was used to quantitatively analyze the GSI, 24-segment SI of left and right ventricles, fractional area change (FAC) left and right ventricular area, and longitudinal contractility in 53 normal singleton fetuses and 16 fetuses with CoA, 24-segment transverse width fractional shortenin FS .p < 0.05 was considered significant. Results Compared with the two groups of fetuses, the global spherical index (GSI) was significantly different (P < 0.05), and the left ventricle 18–24 segment spherical index was significantly different (P < 0.05); the right ventricle 8-11segmental spherical index was significant differences (P < 0.05); there were significant differences in left ventricular fraction area change and longitudinal strain in the CoA group (P < 0.05); there were no significant differences in right ventricular fraction area change and longitudinal strain in the CoA group (P > 0.05); the fetal left ventricular 24-segment transverse width fractional shortening FS in the CoA group was significantly different in segments 1–12 (P<0.05);the FS 1–4 segments were significantly different (P < 0.05). Conclusion fetal HQ technique can quickly and easily obtain the spherical index and systolic function parameters of fetal heart, and provides a new method for quantitative analysis of fetal heart structure and systolic function with CoA.
- 6 January 2023
- Published by Springer Nature in Research Square
Open AccessPreliminary study of fetal HQ in cardiac structure and systolic function of fetal Coarctation of the aorta
Objective To use fetal HQ software to carry out quantitative analysis of the 4-chamber view (4-CV) and left and right ventricle of fetuses with Coarctation of aortic(CoA) and normal fetuses, and to explore the application value of this software in evaluating the cardiac structure and systolic function of fetuses with CoA. Methods fetal HQ software was used to quantitatively analyze the GSI, 24-segment SI of left and right ventricles, fractional area change (FAC) left and right ventricular area, and longitudinal contractility in 53 normal singleton fetuses and 16 fetuses with CoA, 24-segment transverse width fractional shortenin FS .p < 0.05 was considered significant. Results Compared with the two groups of fetuses, the global spherical index (GSI) was significantly different (P < 0.05), and the left ventricle 18–24 segment spherical index was significantly different (P < 0.05); the right ventricle 8-11segmental spherical index was significant differences (P < 0.05); there were significant differences in left ventricular fraction area change and longitudinal strain in the CoA group (P < 0.05); there were no significant differences in right ventricular fraction area change and longitudinal strain in the CoA group (P > 0.05); the fetal left ventricular 24-segment transverse width fractional shortening FS in the CoA group was significantly different in segments 1–12 (P<0.05);the FS 1–4 segments were significantly different (P < 0.05). Conclusion fetal HQ technique can quickly and easily obtain the spherical index and systolic function parameters of fetal heart, and provides a new method for quantitative analysis of fetal heart structure and systolic function with CoA.
- Open Access
- 1 November 2022
- Published by AME Publishing Company in Translational Pediatrics
- Vol. 11 (11) , 1804-1812
Evaluating fetal heart morphology in hypertensive disorders of pregnancy using the fetal heart quantitative technique
Original Article Evaluating fetal heart morphology in hypertensive disorders of pregnancy using the fetal heart quantitative technique Fang Tan, Jiaojiao Yang, Yuqin Shen, Yanfeihai Li, Sihan Fan, Yan Xia, Yuan Zhao, Xueqin Ji
- 1 November 2022
- Published by AME Publishing Company in Translational Pediatrics
- Vol. 11 (11) , 1804-1812
Open AccessEvaluating fetal heart morphology in hypertensive disorders of pregnancy using the fetal heart quantitative technique
Original Article Evaluating fetal heart morphology in hypertensive disorders of pregnancy using the fetal heart quantitative technique Fang Tan, Jiaojiao Yang, Yuqin Shen, Yanfeihai Li, Sihan Fan, Yan Xia, Yuan Zhao, Xueqin Ji
- Open Access
- 9 August 2022
- Published by AME Publishing Company in Translational Pediatrics
- Vol. 11 (8) , 1336-1345
A preliminary study on fetal cardiac morphology and systolic function of normal and anemic pregnant women by fetal heart quantification technology
Original Article A preliminary study on fetal cardiac morphology and systolic function of normal and anemic pregnant women by fetal heart quantification technology Yuqin Shen, Fang Tan, Jiaojiao Yang, Sihan Fan, Lianxiang Zhang, Xueqin Ji
- 9 August 2022
- Published by AME Publishing Company in Translational Pediatrics
- Vol. 11 (8) , 1336-1345
Open AccessA preliminary study on fetal cardiac morphology and systolic function of normal and anemic pregnant women by fetal heart quantification technology
Original Article A preliminary study on fetal cardiac morphology and systolic function of normal and anemic pregnant women by fetal heart quantification technology Yuqin Shen, Fang Tan, Jiaojiao Yang, Sihan Fan, Lianxiang Zhang, Xueqin Ji