Claire-Adeline Dantagnan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Claire-Adeline Dantagnan has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Jean-Pierre Attal
Université Paris Cité, Université Sorbonne Paris Nord, INSERM, Oral Health UMR 1333, 1 rue Maurice Arnoux, Montrouge, 92120, France; Charles Foix Hospital, 7 Avenue de la République, Ivry-sur-Seine, 94200, France
6 shared publicationsJulia Bosco
Université Paris Cité, Université Sorbonne Paris Nord, INSERM, Oral Health UMR 1333, 1 rue Maurice Arnoux, Montrouge, 92120, France; Service Médecine Bucco-Dentaire, AP-HP, Hôpital Pitié-Salpêtrière, Paris, F-75013, France
3 shared publications- Julia Bosco
Pitié Salpêtrière Hospital, Assistance Publique- Hôpitaux de Paris, Paris, France
3 shared publications Maureen Boudrot
Private Practice, Paris, France
3 shared publicationsPhilippe François
Université Paris Cité, Université Sorbonne Paris Nord, INSERM, Oral Health UMR-S 1333, Montrouge, France; Bretonneau Hospital, Paris, France
3 shared publicationsSarah Abdel-Gawad
Faculty of Dentistry, Innovative Dental Materials and Interfaces Research Unit (URB2i), UR 4462, Paris Cité University, Montrouge, France
3 shared publications
Latest Publications
- Open Access
- 17 June 2026
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 181, 107509
Thermomechanical behavior and force modulation of Shape Memory Polymer-Based Orthodontic Aligners: a material-driven biomechanical perspective
- 17 June 2026
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 181, 107509
Open AccessThermomechanical behavior and force modulation of Shape Memory Polymer-Based Orthodontic Aligners: a material-driven biomechanical perspective
- Top Cited PapersOpen Access
- 7 February 2026
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 169 (5) , 640-653
Trueness and precision of direct-printed and thermoformed clear aligners after artificial saliva exposure: A comparative in vitro study
- 7 February 2026
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 169 (5) , 640-653
Top Cited PapersOpen AccessTrueness and precision of direct-printed and thermoformed clear aligners after artificial saliva exposure: A comparative in vitro study
- Open Access
- 21 November 2025
- Published by Elsevier in International Orthodontics
- Vol. 24 (2) , 101089
Effectiveness of universal adhesives for orthodontic bonding to enamel and restorative materials: A systematic review
- 21 November 2025
- Published by Elsevier in International Orthodontics
- Vol. 24 (2) , 101089
Open AccessEffectiveness of universal adhesives for orthodontic bonding to enamel and restorative materials: A systematic review
- Open Access
- 28 May 2025
- Published by Elsevier in International Orthodontics
- Vol. 23 (4) , 101028
Biocompatibility of direct printed clear aligners: A systematic review of in vitro studies
- 28 May 2025
- Published by Elsevier in International Orthodontics
- Vol. 23 (4) , 101028
Open AccessBiocompatibility of direct printed clear aligners: A systematic review of in vitro studies
- Open Access
- 28 December 2024
- Published by Springer Nature in BMC Oral Health
- Vol. 24 (1) , 1-12
Shear bond strength and ARI scores of metal brackets to glazed glass ceramics and zirconia: an in vitro study investigating surface treatment protocols
To evaluate the shear bond strength (SBS) and adhesive remnant index (ARI) scores of metal brackets to glazed lithium disilicate reinforced glass-ceramics and zirconia according to various surface treatment protocols. A total of 240 lithium disilicate ceramic (LD) and 240 zirconia (Zr) blocks were randomly divided according to sandblasting, hydrofluoric acid (HF) etching, universal primer use, and the adhesive system applied. A maxillary canine metal bracket was bonded to each sample with resin cement (Transbond XT, TXT). SBS tests and ARI score analysis were performed. Four-way ANOVA followed by Tukey’s post hoc test was used for SBS differences, and Fisher’s exact test was used for the ARI scores (p < 0.05). All groups combining a universal primer with a universal adhesive with and without sandblasting provided satisfactory SBS values for both LD and Zr. Fractures of the samples were observed only for LD in the groups combining HF with universal primers and universal adhesives with and without sandblasting. Combining a universal primer with a universal adhesive could be recommended for orthodontic bonding to both LD and Zr. Regarding their risks (i.e., damaging the restoration surface or burning the oral tissues), sandblasting or HF might not be necessary despite the presence of glaze covering the ceramic surface.
- 28 December 2024
- Published by Springer Nature in BMC Oral Health
- Vol. 24 (1) , 1-12
Open AccessShear bond strength and ARI scores of metal brackets to glazed glass ceramics and zirconia: an in vitro study investigating surface treatment protocols
To evaluate the shear bond strength (SBS) and adhesive remnant index (ARI) scores of metal brackets to glazed lithium disilicate reinforced glass-ceramics and zirconia according to various surface treatment protocols. A total of 240 lithium disilicate ceramic (LD) and 240 zirconia (Zr) blocks were randomly divided according to sandblasting, hydrofluoric acid (HF) etching, universal primer use, and the adhesive system applied. A maxillary canine metal bracket was bonded to each sample with resin cement (Transbond XT, TXT). SBS tests and ARI score analysis were performed. Four-way ANOVA followed by Tukey’s post hoc test was used for SBS differences, and Fisher’s exact test was used for the ARI scores (p < 0.05). All groups combining a universal primer with a universal adhesive with and without sandblasting provided satisfactory SBS values for both LD and Zr. Fractures of the samples were observed only for LD in the groups combining HF with universal primers and universal adhesives with and without sandblasting. Combining a universal primer with a universal adhesive could be recommended for orthodontic bonding to both LD and Zr. Regarding their risks (i.e., damaging the restoration surface or burning the oral tissues), sandblasting or HF might not be necessary despite the presence of glaze covering the ceramic surface.
- Open Access
Analysis of Resin-Based Dental Materials’ Composition Depending on Their Clinical Applications
The objective of this study was to detail the monomer composition of resin-based dental materials sold in the market in 2023 and to evaluate the proportion of bisphenol A (BPA)-derivatives in relation to their applications. A search on manufacturers’ websites was performed to reference resin-based dental materials currently on the European market (including the European Union (EU) and United Kingdom (UK). Their monomer composition was determined using material-safety data sheets and was completed by a search on the PubMed database. Among the 543 material compositions exploitable, 382 (70.3%) contained BPA derivatives. Among them, 56.2% contained BisGMA and 28% BisEMA, the most frequently reported. A total of 59 monomers, of which six were BPA derivatives, were found. In total, 309 materials (56.9%) contained UDMA and 292 (53.8%) TEGDMA. Less than one third of materials identified contained no BPA derivatives. These proportions vary a lot depending on their applications, with materials dedicated to the dental care of young populations containing the highest proportions of BPA-derivative monomers. The long-term effects on human health of the different monomers identified including BPA-derivative monomers is a source of concern. For children and pregnant or lactating women arises the question of whether to take a precautionary principle and avoid the use of resin-based dental materials likely to release BPA by opting for alternative materials.
Open AccessAnalysis of Resin-Based Dental Materials’ Composition Depending on Their Clinical Applications
The objective of this study was to detail the monomer composition of resin-based dental materials sold in the market in 2023 and to evaluate the proportion of bisphenol A (BPA)-derivatives in relation to their applications. A search on manufacturers’ websites was performed to reference resin-based dental materials currently on the European market (including the European Union (EU) and United Kingdom (UK). Their monomer composition was determined using material-safety data sheets and was completed by a search on the PubMed database. Among the 543 material compositions exploitable, 382 (70.3%) contained BPA derivatives. Among them, 56.2% contained BisGMA and 28% BisEMA, the most frequently reported. A total of 59 monomers, of which six were BPA derivatives, were found. In total, 309 materials (56.9%) contained UDMA and 292 (53.8%) TEGDMA. Less than one third of materials identified contained no BPA derivatives. These proportions vary a lot depending on their applications, with materials dedicated to the dental care of young populations containing the highest proportions of BPA-derivative monomers. The long-term effects on human health of the different monomers identified including BPA-derivative monomers is a source of concern. For children and pregnant or lactating women arises the question of whether to take a precautionary principle and avoid the use of resin-based dental materials likely to release BPA by opting for alternative materials.
- Open Access
- 19 March 2024
- Published by MDPI AG in Preprints.org
Analysis of Resin-Based Dental Materials Composition Depending on Their Clinical Applications
The objective of this study was to detail the monomer composition of resin-based dental materials sold in the market in 2023 and to evaluate the proportion of BPA derivatives in relation with their applications. A search on manufacturers’ websites was performed to reference resin-based dental materials currently on the market. Their monomer composition was determined from material safety data sheets and completed with a search on PubMed database. Among the 543 material compositions exploitable, 382 (70.3%) contained BPA derivatives. Among them, 56.2% contained BisGMA, 28% BisEMA, the most frequently reported. A total of 59 monomers of which 6 BPA-derivatives were found. 309 materials (56.9%) contained UDMA and 292 (53.8%) TEGDMA. Less than one third of materials identified contained no BPA derivatives. These proportions vary a lot depending on their applications with materials dedicated to dental care of young populations containing the highest proportions of BPA-derivatives monomers. The long-term effects on human health of the different monomers identified including BPA-derivatives monomers is a source of concern. For children and pregnant or lactating women arises the question to take a precautionary principle and avoid the use of resin-based dental materials likely to release BPA by opting for alternative materials.
- 19 March 2024
- Published by MDPI AG in Preprints.org
Open AccessAnalysis of Resin-Based Dental Materials Composition Depending on Their Clinical Applications
The objective of this study was to detail the monomer composition of resin-based dental materials sold in the market in 2023 and to evaluate the proportion of BPA derivatives in relation with their applications. A search on manufacturers’ websites was performed to reference resin-based dental materials currently on the market. Their monomer composition was determined from material safety data sheets and completed with a search on PubMed database. Among the 543 material compositions exploitable, 382 (70.3%) contained BPA derivatives. Among them, 56.2% contained BisGMA, 28% BisEMA, the most frequently reported. A total of 59 monomers of which 6 BPA-derivatives were found. 309 materials (56.9%) contained UDMA and 292 (53.8%) TEGDMA. Less than one third of materials identified contained no BPA derivatives. These proportions vary a lot depending on their applications with materials dedicated to dental care of young populations containing the highest proportions of BPA-derivatives monomers. The long-term effects on human health of the different monomers identified including BPA-derivatives monomers is a source of concern. For children and pregnant or lactating women arises the question to take a precautionary principle and avoid the use of resin-based dental materials likely to release BPA by opting for alternative materials.
- Open Access
- 2 January 2024
- Published by Springer Nature in BDJ Open
- Vol. 10 (1) , 1-7
Shear bond strength of a RMGIC for orthodontic bracket bonding to enamel
Objective: To evaluate the shear bond strength (SBS) of a restorative resin-modified glass ionomer cement (RMGIC) for orthodontic bracket bonding. Materials and methods: One hundred twenty-one human teeth were randomly divided into 11 groups (n = 11) according to the surface treatment applied (H3PO4 ± Transbond Plus (TSEP) or Scotchbond Universal (SU)), and the adhesive used (Riva LC HV (RIVA), Fuji Ortho (FUJI), and Transbond XT (TXT)). For each sample, a metal button was bonded. SBS tests were performed at 1 week and debonded specimens were observed for failure modes determination. One-way ANOVA followed by Tukey’s post hoc test was used to compare SBS differences and Fisher’s exact test to analyze the failure modes (p < 0.05). Results: TSEP + FUJI and H3PO4 + SU + TXT showed the highest SBS values while H3PO4 + TSEP + RIVA showed the lowest value. Cohesive failure and mixed failure were found in the groups with SU and TXT and adhesive failure in the other groups. Discussion/Conclusions: The bonding of orthodontic attachments to enamel could be performed with any of the three materials studied. The use of a universal adhesive in the bonding protocol could optimize the adhesion values. Clinical studies would be needed to confirm the results obtained.
- 2 January 2024
- Published by Springer Nature in BDJ Open
- Vol. 10 (1) , 1-7
Open AccessShear bond strength of a RMGIC for orthodontic bracket bonding to enamel
Objective: To evaluate the shear bond strength (SBS) of a restorative resin-modified glass ionomer cement (RMGIC) for orthodontic bracket bonding. Materials and methods: One hundred twenty-one human teeth were randomly divided into 11 groups (n = 11) according to the surface treatment applied (H3PO4 ± Transbond Plus (TSEP) or Scotchbond Universal (SU)), and the adhesive used (Riva LC HV (RIVA), Fuji Ortho (FUJI), and Transbond XT (TXT)). For each sample, a metal button was bonded. SBS tests were performed at 1 week and debonded specimens were observed for failure modes determination. One-way ANOVA followed by Tukey’s post hoc test was used to compare SBS differences and Fisher’s exact test to analyze the failure modes (p < 0.05). Results: TSEP + FUJI and H3PO4 + SU + TXT showed the highest SBS values while H3PO4 + TSEP + RIVA showed the lowest value. Cohesive failure and mixed failure were found in the groups with SU and TXT and adhesive failure in the other groups. Discussion/Conclusions: The bonding of orthodontic attachments to enamel could be performed with any of the three materials studied. The use of a universal adhesive in the bonding protocol could optimize the adhesion values. Clinical studies would be needed to confirm the results obtained.
- Open Access
- 2 November 2023
- Published by Springer Nature in Research Square
Shear bond strength of a RMGIC for orthodontic bracket bonding to enamel
Objective: To evaluate the shear bond strength (SBS) of a restorative resin-modified glass ionomer cement (RMGIC) for orthodontic bracket bonding. Materials and Methods: 121 human teeth were randomly divided into 11 groups (n=11) according to the surface treatment applied (H3PO4 ± Transbond Plus (TSEP) or Scotchbond Universal (SU)), and the adhesive used (Riva LC HV (RIVA), Fuji Ortho (FUJI), and Transbond XT (TXT)). For each sample, a metal button was bonded. SBS tests were performed at one week and debonded specimens were observed for failure modes determination. One-way ANOVA followed by Tukey's post hoc test was used to compare SBS differences and Fisher's exact test to analyse the failure modes (p3PO4+ SU + TXT showed the highest SBS values while H3PO4+ TSEP + RIVA showed the lowest value. Cohesive failure and mixed failure were found in the groups with SU and TXT and adhesive failure in the other groups. Discussion/Conclusions: The bonding of orthodontic attachments to enamel could be performed with any of the three materials studied. The use of a universal adhesive in the bonding protocol could optimize the adhesion values. Clinical studies would be needed to confirm the results obtained.
- 2 November 2023
- Published by Springer Nature in Research Square
Open AccessShear bond strength of a RMGIC for orthodontic bracket bonding to enamel
Objective: To evaluate the shear bond strength (SBS) of a restorative resin-modified glass ionomer cement (RMGIC) for orthodontic bracket bonding. Materials and Methods: 121 human teeth were randomly divided into 11 groups (n=11) according to the surface treatment applied (H3PO4 ± Transbond Plus (TSEP) or Scotchbond Universal (SU)), and the adhesive used (Riva LC HV (RIVA), Fuji Ortho (FUJI), and Transbond XT (TXT)). For each sample, a metal button was bonded. SBS tests were performed at one week and debonded specimens were observed for failure modes determination. One-way ANOVA followed by Tukey's post hoc test was used to compare SBS differences and Fisher's exact test to analyse the failure modes (p3PO4+ SU + TXT showed the highest SBS values while H3PO4+ TSEP + RIVA showed the lowest value. Cohesive failure and mixed failure were found in the groups with SU and TXT and adhesive failure in the other groups. Discussion/Conclusions: The bonding of orthodontic attachments to enamel could be performed with any of the three materials studied. The use of a universal adhesive in the bonding protocol could optimize the adhesion values. Clinical studies would be needed to confirm the results obtained.