Chang Hoon Oh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chang Hoon Oh has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Soo Buem Cho
Department of Radiology, Ewha Womans University Seoul Hospital, College of Medicine, Ewha Womans University, Seoul, Republic of Korea
5 shared publications Sang Lim Choi
Department of Radiology, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, Republic of Korea
4 shared publications- Hyeyoung Kwon
Department of Radiology, Chungnam University Hospital, School of Medicine, Chungnam University, Daejeon 35015, Republic of Korea
3 shared publications Hyo Jeong Lee
Department of Radiology, College of Medicine, Ewha Womans University Mokdong Hospital, Seoul, Republic of Korea
3 shared publications- Hyo Jeong Lee
Ewha Womans University College of Medicine
2 shared publications - Sang Lim Choi
Department of Radiology, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong 14353, Republic of Korea
2 shared publications
Latest Publications
- 29 June 2026
- Published by SAGE Publications in Journal of Endovascular Therapy
Stent-Graft Placement for the Management of Iliac Artery Hemorrhage in Patients With Pelvic Malignancy: Clinical Outcomes and Patency
Purpose: To evaluate clinical outcomes and patency of endovascular stent-graft placement for iliac artery hemorrhage in patients with pelvic malignancy. Methods: We retrospectively reviewed 15 patients (21 cases) with pelvic malignancy undergoing emergency stent-graft placement for iliac artery hemorrhage from December 2011 to April 2025. Technical and clinical success, complications, primary patency, rebleeding rates, and survival were analyzed. Risk factors for rebleeding, specifically the degree of tumor invasion (encasement vs abutment), were assessed. Results: Technical and clinical success were 100%. Significant hemodynamic improvements were achieved: systolic blood pressure (85.5±32.8 vs 114.8±15.7 mmHg; p=0.014), and heart rate (110.7±24.0 vs 93.7±15.9 bpm; p=0.037). During a mean follow-up of 11.5 months, rebleeding occurred in 6 cases (28.6%). Tumor encasement was associated with a numerically higher rebleeding rate compared with abutment (40.0% vs 0%; p=0.123). Cumulative 1-year primary patency and survival rates were 82.9% and 52.5%, respectively. Conclusion: Stent-graft placement appears to be a feasible and potentially effective approach for immediate hemostasis in iliac artery hemorrhage associated with pelvic malignancy. However, careful surveillance is warranted due to a clinically notable risk of rebleeding, particularly in cases with tumor encasement. Clinical Impact: Stent-graft placement offers a reliable, vessel-preserving endovascular option for achieving immediate hemostasis in catastrophic iliac artery hemorrhage associated with pelvic malignancy. This study demonstrates excellent technical and clinical success while identifying progressive tumor encasement as a potential marker for delayed hemorrhagic recurrence. These findings may help clinicians stratify rebleeding risk and tailor post-procedural surveillance according to the degree of tumor-vessel involvement. In cases of recurrent hemorrhage despite repeated stent-graft placement, collateral circulation should be carefully assessed, as therapeutic arterial sacrifice with coil embolization may represent an effective salvage strategy. This study provides practical guidance for managing a rare but life-threatening clinical condition.
- 29 June 2026
- Published by SAGE Publications in Journal of Endovascular Therapy
Stent-Graft Placement for the Management of Iliac Artery Hemorrhage in Patients With Pelvic Malignancy: Clinical Outcomes and Patency
Purpose: To evaluate clinical outcomes and patency of endovascular stent-graft placement for iliac artery hemorrhage in patients with pelvic malignancy. Methods: We retrospectively reviewed 15 patients (21 cases) with pelvic malignancy undergoing emergency stent-graft placement for iliac artery hemorrhage from December 2011 to April 2025. Technical and clinical success, complications, primary patency, rebleeding rates, and survival were analyzed. Risk factors for rebleeding, specifically the degree of tumor invasion (encasement vs abutment), were assessed. Results: Technical and clinical success were 100%. Significant hemodynamic improvements were achieved: systolic blood pressure (85.5±32.8 vs 114.8±15.7 mmHg; p=0.014), and heart rate (110.7±24.0 vs 93.7±15.9 bpm; p=0.037). During a mean follow-up of 11.5 months, rebleeding occurred in 6 cases (28.6%). Tumor encasement was associated with a numerically higher rebleeding rate compared with abutment (40.0% vs 0%; p=0.123). Cumulative 1-year primary patency and survival rates were 82.9% and 52.5%, respectively. Conclusion: Stent-graft placement appears to be a feasible and potentially effective approach for immediate hemostasis in iliac artery hemorrhage associated with pelvic malignancy. However, careful surveillance is warranted due to a clinically notable risk of rebleeding, particularly in cases with tumor encasement. Clinical Impact: Stent-graft placement offers a reliable, vessel-preserving endovascular option for achieving immediate hemostasis in catastrophic iliac artery hemorrhage associated with pelvic malignancy. This study demonstrates excellent technical and clinical success while identifying progressive tumor encasement as a potential marker for delayed hemorrhagic recurrence. These findings may help clinicians stratify rebleeding risk and tailor post-procedural surveillance according to the degree of tumor-vessel involvement. In cases of recurrent hemorrhage despite repeated stent-graft placement, collateral circulation should be carefully assessed, as therapeutic arterial sacrifice with coil embolization may represent an effective salvage strategy. This study provides practical guidance for managing a rare but life-threatening clinical condition.
- Open Access
- 1 January 2026
- Published by XMLink in Korean Journal of Radiology
- Vol. 27 (7) , 610-620
Agentic Artificial Intelligence for the Automated Generation of Accurate Summary Podcasts of Radiology Research Papers
To evaluate whether a custom agentic artificial intelligence (AI) pipeline can overcome the limitations of general-purpose large language model tools, when compared with a generic commercial tool (Google NotebookLM [NBLM]), for generating podcast-style summaries of radiology research articles. Twenty-two PDF-format original research articles published in the April 2025 issue of Radiology were processed using our Programmable, Phoneme-Aware PDF-to-Podcast Pipeline (P5) and NBLM to generate 44 audio episodes. P5 utilizes a multi-agent workflow for script generation, quality assurance, pronunciation enhancement, and audio synthesis. Four radiologists from a pool of 25 (7 generalists and 18 specialists) were randomly assigned to evaluate each blinded audio episode, yielding 176 total evaluations. The primary outcomes were the number of hallucinations (factual errors) per episode and the percentage of hallucination-free episodes. Secondary outcomes included the number of inappropriate statements, mispronunciations, and flow disruptions; the composite quality score (Quality Assessment of Educational Podcasts [QAEP]); the key results coverage score; and overall listener preference. Data were analyzed using generalized linear mixed models. The P5 method produced significantly fewer hallucinations per episode compared with NBLM (mean, 0.32 vs. 0.93; P < 0.001) and a higher proportion of hallucination-free episodes (71.6% [63/88] vs. 56.8% [50/88]; P = 0.013), consistently across generalists and specialists. P5 demonstrated significantly fewer mispronunciations (mean, 0.11 vs. 1.62; P < 0.001) and flow disruptions (mean, 0.19 vs. 1.06; P < 0.001) per episode, as well as higher mean QAEP composite scores (4.62 vs. 4.28; P < 0.001), compared with NBLM, consistently across generalists and specialists. Raters preferred P5 over NBLM in 72.7% (64/88) of comparisons (P = 0.003). Our custom agentic AI pipeline generated podcast-style summaries of radiology research articles with significantly higher quality and greater listener preference than the generic commercial tool.
- 1 January 2026
- Published by XMLink in Korean Journal of Radiology
- Vol. 27 (7) , 610-620
Open AccessAgentic Artificial Intelligence for the Automated Generation of Accurate Summary Podcasts of Radiology Research Papers
To evaluate whether a custom agentic artificial intelligence (AI) pipeline can overcome the limitations of general-purpose large language model tools, when compared with a generic commercial tool (Google NotebookLM [NBLM]), for generating podcast-style summaries of radiology research articles. Twenty-two PDF-format original research articles published in the April 2025 issue of Radiology were processed using our Programmable, Phoneme-Aware PDF-to-Podcast Pipeline (P5) and NBLM to generate 44 audio episodes. P5 utilizes a multi-agent workflow for script generation, quality assurance, pronunciation enhancement, and audio synthesis. Four radiologists from a pool of 25 (7 generalists and 18 specialists) were randomly assigned to evaluate each blinded audio episode, yielding 176 total evaluations. The primary outcomes were the number of hallucinations (factual errors) per episode and the percentage of hallucination-free episodes. Secondary outcomes included the number of inappropriate statements, mispronunciations, and flow disruptions; the composite quality score (Quality Assessment of Educational Podcasts [QAEP]); the key results coverage score; and overall listener preference. Data were analyzed using generalized linear mixed models. The P5 method produced significantly fewer hallucinations per episode compared with NBLM (mean, 0.32 vs. 0.93; P < 0.001) and a higher proportion of hallucination-free episodes (71.6% [63/88] vs. 56.8% [50/88]; P = 0.013), consistently across generalists and specialists. P5 demonstrated significantly fewer mispronunciations (mean, 0.11 vs. 1.62; P < 0.001) and flow disruptions (mean, 0.19 vs. 1.06; P < 0.001) per episode, as well as higher mean QAEP composite scores (4.62 vs. 4.28; P < 0.001), compared with NBLM, consistently across generalists and specialists. Raters preferred P5 over NBLM in 72.7% (64/88) of comparisons (P = 0.003). Our custom agentic AI pipeline generated podcast-style summaries of radiology research articles with significantly higher quality and greater listener preference than the generic commercial tool.
- Open Access
- 10 March 2025
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 21, 1-9
Clinical Outcomes of Total or Partial Renal Artery Embolization in Patients with Spontaneous Renal Bleeding
Aims: The aim of this study was to evaluate renal artery embolization in patients with spontaneous renal artery bleeding based on detailed angiographic findings and a comprehensive analysis of its efficacy and clinical outcomes. Materials and Methods: This retrospective study evaluated the outcomes of renal artery embolization in 18 cases among 15 patients (11 men and 4 women; mean age: 57.9 years) treated for spontaneous renal bleeding at our institution between March 2017 and October 2023. Data derived from abdominal computed tomography (CT) and arteriography were analyzed to assess the effectiveness of embolization. Results: Most patients had end-stage renal disease or renal atrophy, with common findings on CT scans, including signs of active bleeding in 66.7% (10/15) and hematoma extending to the retroperitoneal space in 53.3% (8/15). Microcoils were commonly used for embolization (n = 10), with a technical success rate of 100% and primary and final clinical success rates of 80% and 100%, respectively. No major complications were reported during the follow-up, and clinical improvement was observed in all patients who underwent total embolization, with few instances of reduced hematoma size and renal atrophy. Conclusion: Transarterial embolization is safe and effective for controlling spontaneous renal hemorrhage.
- 10 March 2025
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 21, 1-9
Open AccessClinical Outcomes of Total or Partial Renal Artery Embolization in Patients with Spontaneous Renal Bleeding
Aims: The aim of this study was to evaluate renal artery embolization in patients with spontaneous renal artery bleeding based on detailed angiographic findings and a comprehensive analysis of its efficacy and clinical outcomes. Materials and Methods: This retrospective study evaluated the outcomes of renal artery embolization in 18 cases among 15 patients (11 men and 4 women; mean age: 57.9 years) treated for spontaneous renal bleeding at our institution between March 2017 and October 2023. Data derived from abdominal computed tomography (CT) and arteriography were analyzed to assess the effectiveness of embolization. Results: Most patients had end-stage renal disease or renal atrophy, with common findings on CT scans, including signs of active bleeding in 66.7% (10/15) and hematoma extending to the retroperitoneal space in 53.3% (8/15). Microcoils were commonly used for embolization (n = 10), with a technical success rate of 100% and primary and final clinical success rates of 80% and 100%, respectively. No major complications were reported during the follow-up, and clinical improvement was observed in all patients who underwent total embolization, with few instances of reduced hematoma size and renal atrophy. Conclusion: Transarterial embolization is safe and effective for controlling spontaneous renal hemorrhage.
- Open Access
- 1 January 2025
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 86 (6) , 1058-1063
Successful Endovascular Embolization for Hemorrhage from Superficial Inferior Epigastric Artery after Inguinal Hernia Repair: A Case Report
조상아, et al. J Korean Soc Radiol. 2025 Nov;86:e49. https://doi.org/10.3348/jksr.2024.0120
- 1 January 2025
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 86 (6) , 1058-1063
Open AccessSuccessful Endovascular Embolization for Hemorrhage from Superficial Inferior Epigastric Artery after Inguinal Hernia Repair: A Case Report
조상아, et al. J Korean Soc Radiol. 2025 Nov;86:e49. https://doi.org/10.3348/jksr.2024.0120
- Open Access
- 1 January 2025
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 109 (1) , 1
Clinical Outcome and Utility of Cone‑Beam Computed Tomography Imaging for Transcatheter Arterial Embolization in Patients with Malignant Intractable Hematuria
Background: We assess the clinical outcomes and utility of cone‑beam computed tomography (CBCT) during transcatheter arterial embolization (TAE) in patients with malignant intractable hematuria, related to lower urinary tract malignancy.
- 1 January 2025
- Published by Ubiquity Press, Ltd. in Journal of the Belgian Society of Radiology
- Vol. 109 (1) , 1
Open AccessClinical Outcome and Utility of Cone‑Beam Computed Tomography Imaging for Transcatheter Arterial Embolization in Patients with Malignant Intractable Hematuria
Background: We assess the clinical outcomes and utility of cone‑beam computed tomography (CBCT) during transcatheter arterial embolization (TAE) in patients with malignant intractable hematuria, related to lower urinary tract malignancy.
- Open Access
- 12 December 2024
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 20 (1) , 1-9
Clinical Outcomes of Transcatheter Arterial Embolization in Patients with High-grade Gross Hematuria
Introduction: To investigate factors influencing the effectiveness and safety of super-selective embolization in patients with high-grade gross hematuria. Materials and Methods: This retrospective, single-center study included 19 consecutive cancer patients (12 men and 7 women, mean age of 72.3 years) who had undergone TAE for intractable hematuria between January 2008 and February 2024. Factors such as technical and clinical success rates, embolized vessels, embolic agents used, and complications were evaluated. This study specifically focused on patients with severe hematuria (grade 3 or above) and examined the effects of super-selective embolization, hematuria grade, and embolic agents on patient outcomes. Results: Technical success was achieved in all 23 angiography procedures performed, with a clinical success rate of 56.5%. Clinical success was significantly correlated with hematuria grade, super-selectivity of the procedure, and type of embolic agent used. Multivariate logistic regression analysis revealed that the embolic material, specifically tris-acryl gelatin microspheres (TAGM), was an independent factor that significantly affected clinical outcomes. No major complications were reported. Conclusion: TAGM for supers-elective embolization in patients with massive gross hematuria is both effective and safe. However, the effectiveness of TAE may decrease in patients with severe hematuria, highlighting the need for combination therapies.
- 12 December 2024
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 20 (1) , 1-9
Open AccessClinical Outcomes of Transcatheter Arterial Embolization in Patients with High-grade Gross Hematuria
Introduction: To investigate factors influencing the effectiveness and safety of super-selective embolization in patients with high-grade gross hematuria. Materials and Methods: This retrospective, single-center study included 19 consecutive cancer patients (12 men and 7 women, mean age of 72.3 years) who had undergone TAE for intractable hematuria between January 2008 and February 2024. Factors such as technical and clinical success rates, embolized vessels, embolic agents used, and complications were evaluated. This study specifically focused on patients with severe hematuria (grade 3 or above) and examined the effects of super-selective embolization, hematuria grade, and embolic agents on patient outcomes. Results: Technical success was achieved in all 23 angiography procedures performed, with a clinical success rate of 56.5%. Clinical success was significantly correlated with hematuria grade, super-selectivity of the procedure, and type of embolic agent used. Multivariate logistic regression analysis revealed that the embolic material, specifically tris-acryl gelatin microspheres (TAGM), was an independent factor that significantly affected clinical outcomes. No major complications were reported. Conclusion: TAGM for supers-elective embolization in patients with massive gross hematuria is both effective and safe. However, the effectiveness of TAE may decrease in patients with severe hematuria, highlighting the need for combination therapies.
- Open Access
- 31 July 2024
- Published by Korean Pancreatobiliary Association in The Korean Journal of Pancreas and Biliary Tract
- Vol. 29 (3) , 69-84
Guideline for Minimizing Radiation Exposure of Interventionalists during Fluoroscopy-Guided Interventional Procedures
As fluoroscopy-guided interventional procedures gain popularity, the associated health threats from radiation exposure to interventionalists during these procedures are increasing. Therefore, an understanding of the potential risks of radiation and careful consideration on minimizing exposure to radiation during the procedures are of paramount importance. The Korean Pancreatobiliary Association has developed a clinical practice guideline to minimize radiation exposure during fluoroscopy-guided interventional procedures. This guideline provides recommendations to deal with the risk of radiation exposure to interventionalists who perform fluoroscopy-guided procedures, and emphasizes the importance of proper and practical approaches to avoid unnecessary radiation exposure.
- 31 July 2024
- Published by Korean Pancreatobiliary Association in The Korean Journal of Pancreas and Biliary Tract
- Vol. 29 (3) , 69-84
Open AccessGuideline for Minimizing Radiation Exposure of Interventionalists during Fluoroscopy-Guided Interventional Procedures
As fluoroscopy-guided interventional procedures gain popularity, the associated health threats from radiation exposure to interventionalists during these procedures are increasing. Therefore, an understanding of the potential risks of radiation and careful consideration on minimizing exposure to radiation during the procedures are of paramount importance. The Korean Pancreatobiliary Association has developed a clinical practice guideline to minimize radiation exposure during fluoroscopy-guided interventional procedures. This guideline provides recommendations to deal with the risk of radiation exposure to interventionalists who perform fluoroscopy-guided procedures, and emphasizes the importance of proper and practical approaches to avoid unnecessary radiation exposure.
- Open Access
Temporary Ureter Occlusion with Simultaneous Urinary Diversion via a Single-Access Route Using a 4-French Balloon Catheter and a Pigtail Nephrostomy Drainage Catheter
Background and Objectives: This study evaluated the efficacy and safety of temporary ureteral occlusion combined with urinary diversion using a single-access route created by inserting a balloon catheter through a pigtail nephrostomy drainage catheter. With this approach, we aimed to offer an alternative for patients with ureteral leaks who are suboptimal surgical candidates. Materials and Methods: This retrospective study included nine patients (eight of which were bilateral cases and one was unilateral, totaling seventeen cases) who underwent the surgery between September 2023 and March 2024. The method involved gaining percutaneous access to the pelvicalyceal system, inserting a 4-French Fogarty balloon catheter through a pigtail nephrostomy catheter, and inflating the balloon at the proximal or mid-ureter. Results: All 17 cases achieved technical successful with no major complications. The procedure effectively relieved symptoms associated with urinary leakage in most patients. However, the significant deflation of the balloon catheter occurred in five cases (29.4%), with three (17.6%) experiencing complete deflation. In these five cases, the final balloon size was 5.81 mm (range: 0–8.9 mm), confirming a 25.0% decrease in size from pre- to post-procedure. Ureteral occlusion was 28.3 d long on average (range: 8–57 d). All patients experienced symptom relief during temporary ureteral occlusion. Except for two patients lost to follow-up, three patients showed symptom improvement with only PCN and four patients underwent surgical closure of the fistula tract before or after balloon catheter removal. Conclusions: This study confirms that this approach is safe and effective.
Open AccessTemporary Ureter Occlusion with Simultaneous Urinary Diversion via a Single-Access Route Using a 4-French Balloon Catheter and a Pigtail Nephrostomy Drainage Catheter
Background and Objectives: This study evaluated the efficacy and safety of temporary ureteral occlusion combined with urinary diversion using a single-access route created by inserting a balloon catheter through a pigtail nephrostomy drainage catheter. With this approach, we aimed to offer an alternative for patients with ureteral leaks who are suboptimal surgical candidates. Materials and Methods: This retrospective study included nine patients (eight of which were bilateral cases and one was unilateral, totaling seventeen cases) who underwent the surgery between September 2023 and March 2024. The method involved gaining percutaneous access to the pelvicalyceal system, inserting a 4-French Fogarty balloon catheter through a pigtail nephrostomy catheter, and inflating the balloon at the proximal or mid-ureter. Results: All 17 cases achieved technical successful with no major complications. The procedure effectively relieved symptoms associated with urinary leakage in most patients. However, the significant deflation of the balloon catheter occurred in five cases (29.4%), with three (17.6%) experiencing complete deflation. In these five cases, the final balloon size was 5.81 mm (range: 0–8.9 mm), confirming a 25.0% decrease in size from pre- to post-procedure. Ureteral occlusion was 28.3 d long on average (range: 8–57 d). All patients experienced symptom relief during temporary ureteral occlusion. Except for two patients lost to follow-up, three patients showed symptom improvement with only PCN and four patients underwent surgical closure of the fistula tract before or after balloon catheter removal. Conclusions: This study confirms that this approach is safe and effective.
- Open Access
- 4 June 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (11) , 3317
Clinical Outcomes and Safety of Transcatheter Arterial Embolization in Patients with Traumatic or Spontaneous Psoas and Retroperitoneal Hemorrhage
Background: We aimed to assess the effectiveness and safety of transcatheter arterial embolization (TAE) in the management of spontaneous or traumatic psoas and/or retroperitoneal hemorrhage. Methods: This single-center retrospective study enrolled 36 patients who underwent TAE for the treatment of psoas and/or retroperitoneal hemorrhage between May 2016 and February 2024. Results: The patients’ mean age was 61.3 years. The spontaneous group (SG, 47.1%) showed higher rates of anticoagulation therapy use compared with the trauma group (TG, 15.8%) (p = 0.042). The TG (94.7%) demonstrated higher survival rates compared with the SG (64.7%; p = 0.023). Clinical failure was significantly associated with the liver cirrhosis (p = 0.001), prothrombin time (p = 0.004), and international normalized ratio (p = 0.007) in SG and pRBC transfusion (p = 0.008) in TG. Liver cirrhosis (OR (95% CI): 55.055 (2.439–1242.650), p = 0.012) was the only identified independent risk factor for primary clinical failure in the multivariate logistic regression analysis. Conclusions: TAE was a safe and effective treatment for psoas and/or retroperitoneal hemorrhage, regardless of the cause of bleeding. However, liver cirrhosis or the need for massive transfusion due to hemorrhage increased the risk of clinical failure and mortality, necessitating aggressive monitoring and treatment.
- 4 June 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (11) , 3317
Open AccessClinical Outcomes and Safety of Transcatheter Arterial Embolization in Patients with Traumatic or Spontaneous Psoas and Retroperitoneal Hemorrhage
Background: We aimed to assess the effectiveness and safety of transcatheter arterial embolization (TAE) in the management of spontaneous or traumatic psoas and/or retroperitoneal hemorrhage. Methods: This single-center retrospective study enrolled 36 patients who underwent TAE for the treatment of psoas and/or retroperitoneal hemorrhage between May 2016 and February 2024. Results: The patients’ mean age was 61.3 years. The spontaneous group (SG, 47.1%) showed higher rates of anticoagulation therapy use compared with the trauma group (TG, 15.8%) (p = 0.042). The TG (94.7%) demonstrated higher survival rates compared with the SG (64.7%; p = 0.023). Clinical failure was significantly associated with the liver cirrhosis (p = 0.001), prothrombin time (p = 0.004), and international normalized ratio (p = 0.007) in SG and pRBC transfusion (p = 0.008) in TG. Liver cirrhosis (OR (95% CI): 55.055 (2.439–1242.650), p = 0.012) was the only identified independent risk factor for primary clinical failure in the multivariate logistic regression analysis. Conclusions: TAE was a safe and effective treatment for psoas and/or retroperitoneal hemorrhage, regardless of the cause of bleeding. However, liver cirrhosis or the need for massive transfusion due to hemorrhage increased the risk of clinical failure and mortality, necessitating aggressive monitoring and treatment.
- Open Access
- 19 April 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103 (16) , e37765
Migration of double-J ureteral stent in patients with ureteroileal anastomosis stricture undergoing radical cystectomy and orthotopic neobladder: Analysis risk factors of stent migration
The objective was to evaluate the incidence and degree of double-J ureteral stent (DJUS) migration. Additionally, we aimed to investigate the risk factors associated with stent migration in the orthotopic neobladder group. In this retrospective study, 61 consecutive patients were included; 35 patients (45 DJUS placements) underwent radical cystectomy with orthotopic neobladder and 26 patients (35 DJUS placements) underwent urinary bladder without cystectomy between July 2021 and March 2023. All the patients were treated with a DJUS for ureteric strictures. The technical success rate was 100% in each group. The DJUS migration was significantly higher in the orthotopic neobladder group, with 22 of 45 cases (48.9%), compared to the urinary bladder group, which had 4 of 35 cases (11.4%) (P ≤ .001). Among the patients in the orthotopic neobladder group who experienced DJUS migration, stent dysfunction occurred in 18 cases (81.8%), which was statistically significant (P = .003). Multivariate logistic regression analysis revealed that only the size of the DJUS was significantly and positively associated with migration (odds ratio:10.214, P = .010). DJUS migration can easily occur in patients undergoing radical cystectomy and orthotopic neobladder, and smaller stent sizes are associated with a higher incidence of migration.
- 19 April 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103 (16) , e37765
Open AccessMigration of double-J ureteral stent in patients with ureteroileal anastomosis stricture undergoing radical cystectomy and orthotopic neobladder: Analysis risk factors of stent migration
The objective was to evaluate the incidence and degree of double-J ureteral stent (DJUS) migration. Additionally, we aimed to investigate the risk factors associated with stent migration in the orthotopic neobladder group. In this retrospective study, 61 consecutive patients were included; 35 patients (45 DJUS placements) underwent radical cystectomy with orthotopic neobladder and 26 patients (35 DJUS placements) underwent urinary bladder without cystectomy between July 2021 and March 2023. All the patients were treated with a DJUS for ureteric strictures. The technical success rate was 100% in each group. The DJUS migration was significantly higher in the orthotopic neobladder group, with 22 of 45 cases (48.9%), compared to the urinary bladder group, which had 4 of 35 cases (11.4%) (P ≤ .001). Among the patients in the orthotopic neobladder group who experienced DJUS migration, stent dysfunction occurred in 18 cases (81.8%), which was statistically significant (P = .003). Multivariate logistic regression analysis revealed that only the size of the DJUS was significantly and positively associated with migration (odds ratio:10.214, P = .010). DJUS migration can easily occur in patients undergoing radical cystectomy and orthotopic neobladder, and smaller stent sizes are associated with a higher incidence of migration.