    Lithium isotopic separation by electrodeposition on nickel: A TOF-SIMS profile analysis

    by Federico M. Cabello, Laura C. Baqué, Marina S. Bellora, Federico A. Viva, Horacio R. Corti

    The electrodeposition/insertion of lithium on metallic or metal-oxide cathodes emerges as a potential procedure for economic and sustainable separation of its two stable isotopes (6Li and 7Li) that could replace the COLEX method for the enrichment of 6Li, a key precursor for tritium production in the breeding blankets of future nuclear fusion reactors. Here, we experimentally study the isotopic separation of Li by electrodeposition on Ni from a LiTFSI/diglime electrolyte by resorting to Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS). The used methodology allowed a reliable monitoring of the 6Li/7Li isotopic ratio evolution throughout the thickness of the deposits. All samples exhibited a systematic decrease in the measured 6Li/7Li ratio toward the Li/Ni interface, indicating that the outer regions of the deposits are enriched in 6Li compared with the lithium deposited during the initial stages of electrodeposition. The Li deposits formed at higher overpotentials exhibited isotopic gradient steeper than those formed at lower overpotentials, whereas prolonged deposition resulted in smoother isotopic profiles. The experimental observations are consistent with previous Density Functional Theory (DFT) calculations, which predict that lithium atoms with lower effective coordination numbers exhibit larger equilibrium isotope effects. This work demonstrates that TOF-SIMS depth profiling is a powerful tool for investigating lithium isotope fractionation in electrodeposited materials and provides new experimental insight into the relationship between deposit morphology, local atomic structure, and isotope separation.

  • Wettability, imbibition and interdiffusion of lithium-based water-in-salt electrolytes in nanoporous carbon in relation to energy storage: A neutron radiography study

    by Federico M. Cabello, Gabriela Horwitz, Aureliano Tartaglione, Michael Schulz, Julio H. Marin, Abigail Rozenblit, Mario A. Trejo Urdaneta, Marina S. Bellora, Federico A. Viva, Horacio R. Corti


  • Open Access

    Assessing dead time effects when attempting isotope ratio quantification by time-of-flight secondary ion mass spectrometry

    by Laura C. Baqué, Federico M. Cabello, Federico A. Viva, Horacio R. Corti

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is a quasi-non-destructive technique capable of analyzing the outer monolayers of a solid sample and detecting all elements of the periodic table and their isotopes. Its ability to analyze the outer monolayers resides in sputtering the sample surface with a low-dose primary ion gun, which, in turn, imposes the use of a detector capable of counting a single ion at a time. Consequently, the detector saturates when more than one ion arrives at the same time hindering the use of TOF-SIMS for quantification purposes such as isotope ratio estimation. Even though a simple Poisson-based correction is usually implemented in TOF-SIMS acquisition software to compensate the detector saturation effects, this correction is only valid up to a certain extent and can be unnoticed by the inexperienced user. This tutorial describes a methodology based on different practices reported in the literature for dealing with the detector saturation effects and assessing the validity limits of Poisson-based correction when attempting to use TOF-SIMS data for quantification purposes. As a practical example, a dried lithium hydroxide solution was analyzed by TOF-SIMS with the aim of estimating the 6Li/7Li isotope ratio. The approach presented here can be used by new TOF-SIMS users on their own data for understanding the effects of detector saturation, determine the validity limits of Poisson-based correction, and take into account important considerations when treating the data for quantification purposes.