Somchat Jiriwibhakorn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Somchat Jiriwibhakorn has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Shazia Kanwal
School of Engineering, King Mongkuts Institute of Technology Ladkrabang (KMITL), Bangkok, Thailand
4 shared publications Kamolwan Wongwut
School of Engineering, King Mongkuts Institute of Technology Ladkrabang (KMITL), Bangkok, Thailand
2 shared publications- Khanittha Wannakam
Rajamangala University of Technology Suvarnabhumi
1 shared publication
Latest Publications
- Open Access
- 5 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (19) , 9866
Machine Learning and Deep Learning Techniques for Fault Location in Transmission Lines
Fault location in a power system is a sensitive task because of the grid’s complex environment. Traditional fault-location methods that rely only on impedance estimates or traveling waves are less accurate than before because modern transmission networks are more complex due to the integration of wind resources, power electronic interfaces, and changing operating conditions. This study provides an artificial intelligence-based comparative framework for transmission line fault locating based on models such as artificial neural network (ANN), adaptive neuro-fuzzy inference system (ANFIS), convolutional neural network (CNN), long short-term memory network (LSTM), and bidirectional long short-term memory network (BiLSTM). The suggested configuration is tested on both the IEEE 9-bus test system and the IEEE 30-bus test system to explore the impact of the size and complexity of the network on model performance. The test systems are simulated in MATLAB (Version R2024a)/Simulink for various operating conditions, fault locations, and fault types. The faults are measured by three-phase voltage and three-phase current at one end of the transmission line, and the distance to the fault is used as the regression variable for the modeling. The mean square error, root mean square error, mean absolute error, coefficient of determination, as well as training and testing performance in modifying the models, are used for assessing model performance. ANFIS has yielded the best results for the verified fault location of the IEEE 9-bus system, with RMSE, MAE, and R2 equal to 1.880 km, 1.142 km, and 0.996, respectively, and better than the traditional ANN model and other deep learning models. The deep learning technique that performed best on the larger system, the 30-bus IEEE system, was BiLSTM with a testing RMSE of 2.909 km, an MAE of 1.841 km, and an R2 value of 0.998. The results showed that ANFIS shows good performance in the small category of the system due to its nonlinear rule-based learning, while, on the other hand, BiLSTM has good performance in larger-scale and complex systems owing to its learning capability in a bidirectional manner in voltage and current signals. The comparative analysis presented in this work reveals that intelligent regression models can estimate single-ended fault location, are robust, and have great potential for use in real-time transmission line protection systems.
- 5 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (19) , 9866
Open AccessMachine Learning and Deep Learning Techniques for Fault Location in Transmission Lines
Fault location in a power system is a sensitive task because of the grid’s complex environment. Traditional fault-location methods that rely only on impedance estimates or traveling waves are less accurate than before because modern transmission networks are more complex due to the integration of wind resources, power electronic interfaces, and changing operating conditions. This study provides an artificial intelligence-based comparative framework for transmission line fault locating based on models such as artificial neural network (ANN), adaptive neuro-fuzzy inference system (ANFIS), convolutional neural network (CNN), long short-term memory network (LSTM), and bidirectional long short-term memory network (BiLSTM). The suggested configuration is tested on both the IEEE 9-bus test system and the IEEE 30-bus test system to explore the impact of the size and complexity of the network on model performance. The test systems are simulated in MATLAB (Version R2024a)/Simulink for various operating conditions, fault locations, and fault types. The faults are measured by three-phase voltage and three-phase current at one end of the transmission line, and the distance to the fault is used as the regression variable for the modeling. The mean square error, root mean square error, mean absolute error, coefficient of determination, as well as training and testing performance in modifying the models, are used for assessing model performance. ANFIS has yielded the best results for the verified fault location of the IEEE 9-bus system, with RMSE, MAE, and R2 equal to 1.880 km, 1.142 km, and 0.996, respectively, and better than the traditional ANN model and other deep learning models. The deep learning technique that performed best on the larger system, the 30-bus IEEE system, was BiLSTM with a testing RMSE of 2.909 km, an MAE of 1.841 km, and an R2 value of 0.998. The results showed that ANFIS shows good performance in the small category of the system due to its nonlinear rule-based learning, while, on the other hand, BiLSTM has good performance in larger-scale and complex systems owing to its learning capability in a bidirectional manner in voltage and current signals. The comparative analysis presented in this work reveals that intelligent regression models can estimate single-ended fault location, are robust, and have great potential for use in real-time transmission line protection systems.
- Open Access
- 23 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 184133-184146
A Novel Enhancement of the Classical Lambda Iteration Method for Solving Economic Load Dispatch Problem of Cost Function With Integrated Renewables
This paper presents a novel enhancement to the classical lambda iteration method for solving the economic load dispatch problem under modern power system conditions. The traditional LI method works well for simple cost functions, but it struggles with the complexities caused by valve-point effects and the growing use of renewable energy sources. Unlike metaheuristic methods that can be flexible but usually require a lot of computing power and are sensitive to how their settings are adjusted, the new λ-algorithm keeps the straightforward and predictable features of the original method while making it suitable for complicated situations involving non-convex costs and renewable energy sources. The algorithm incorporates mechanisms to handle non-smooth cost functions and account for variability from wind and solar generation. Its effectiveness is tested using simulations on four standard systems: an IEEE 57-bus system without renewable energy that cost $288,576; a modified IEEE 57-bus system with renewable energy that cost $283,774; a 38-generator system with a smooth cost function that cost $9,417,174.09 and CPU time of 1.3708 seconds; and a 40-generator system with valve-point effects that cost $121,714.07 and CPU time of 235.05 seconds. In all situations, the developed λ-algorithm provides affordable solutions while greatly cutting down on computing time, showing that it could be a useful, easy-to-use, and adaptable option for today's ELD problems.
- 23 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 184133-184146
Open AccessA Novel Enhancement of the Classical Lambda Iteration Method for Solving Economic Load Dispatch Problem of Cost Function With Integrated Renewables
This paper presents a novel enhancement to the classical lambda iteration method for solving the economic load dispatch problem under modern power system conditions. The traditional LI method works well for simple cost functions, but it struggles with the complexities caused by valve-point effects and the growing use of renewable energy sources. Unlike metaheuristic methods that can be flexible but usually require a lot of computing power and are sensitive to how their settings are adjusted, the new λ-algorithm keeps the straightforward and predictable features of the original method while making it suitable for complicated situations involving non-convex costs and renewable energy sources. The algorithm incorporates mechanisms to handle non-smooth cost functions and account for variability from wind and solar generation. Its effectiveness is tested using simulations on four standard systems: an IEEE 57-bus system without renewable energy that cost $288,576; a modified IEEE 57-bus system with renewable energy that cost $283,774; a 38-generator system with a smooth cost function that cost $9,417,174.09 and CPU time of 1.3708 seconds; and a 40-generator system with valve-point effects that cost $121,714.07 and CPU time of 235.05 seconds. In all situations, the developed λ-algorithm provides affordable solutions while greatly cutting down on computing time, showing that it could be a useful, easy-to-use, and adaptable option for today's ELD problems.
- Open Access
- 4 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 118135-118146
Time Series-Based Fault Detection and Classification in IEEE 9-Bus Transmission Lines Using Deep Learning
Transmission line faults present a significant threat to the stability of power systems, potentially causing widespread outages. Timely detection of these faults is essential to prevent substantial disruptions in the power supply. This paper explores a time series-based deep learning technique for fault detection and classification in the IEEE 9-bus system. Post asymmetrical fault current and voltage time series data have been used to train a convolutional neural network (CNN), representing normal and faulty conditions, with convolutional and ReLU layers. A fully connected layer is used to detect features without missing critical information of the signal, achieving MSE as zero for fault detection and 0.0149 for fault classification. This demonstrates the effectiveness of CNNs for real-time fault detection and classification in complex power grids. The robustness of the CNN model indicates its potential for deployment in practical applications, enhancing the reliability and resilience of the transmission network. Using deep learning techniques opens opportunities for further improvements in fault detection and location strategies within the power grid.
- 4 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 118135-118146
Open AccessTime Series-Based Fault Detection and Classification in IEEE 9-Bus Transmission Lines Using Deep Learning
Transmission line faults present a significant threat to the stability of power systems, potentially causing widespread outages. Timely detection of these faults is essential to prevent substantial disruptions in the power supply. This paper explores a time series-based deep learning technique for fault detection and classification in the IEEE 9-bus system. Post asymmetrical fault current and voltage time series data have been used to train a convolutional neural network (CNN), representing normal and faulty conditions, with convolutional and ReLU layers. A fully connected layer is used to detect features without missing critical information of the signal, achieving MSE as zero for fault detection and 0.0149 for fault classification. This demonstrates the effectiveness of CNNs for real-time fault detection and classification in complex power grids. The robustness of the CNN model indicates its potential for deployment in practical applications, enhancing the reliability and resilience of the transmission network. Using deep learning techniques opens opportunities for further improvements in fault detection and location strategies within the power grid.
- Open Access
- 11 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 132352-132368
Evaluation of the Power Demand for Economic Load Dispatch Problem Using Adaptive Neuro-Fuzzy Inference System and Artificial Neural Network
The evaluation of power demand is fundamental in the Economic Load Dispatch problem, ensuring that the generated power meets the needs of consumers reliably and efficiently in planning system operations. This paper presented two approaches using an Adaptive Neuro-Fuzzy Inference System (ANFIS) and an Artificial Neural Network (ANN) to evaluate the power demand. The modified IEEE 57-Bus system is considered the thermal units that incorporate renewables. The ANFIS and ANN are implemented using MATLAB online version R2023b. The results show that the ANN and ANFIS techniques are suitable for evaluating power demand. A comparison of both methods indicates that ANFIS is relatively superior to the ANNs techniques, considering the coefficient of determination of the ANNs and ANFIS were equal. The accuracy of its results in terms of prediction RMSE for the ANN and ANFIS of 10.147e-05 and 5.2177e-05 for the training and 14.639e-05 and 5.2177e-05 for the testing, respectively. Finally, the prediction accuracy of the ANFIS can be observed to be higher than that of the ANN, but the ANFIS takes longer to process. ANFIS is the method that can be appropriately applied to evaluate the power demand in this research. However, it could not guarantee for other research topics that ANFIS would be better than ANN for the RMSE. It depends on input and output data complexity and the training function type.
- 11 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 132352-132368
Open AccessEvaluation of the Power Demand for Economic Load Dispatch Problem Using Adaptive Neuro-Fuzzy Inference System and Artificial Neural Network
The evaluation of power demand is fundamental in the Economic Load Dispatch problem, ensuring that the generated power meets the needs of consumers reliably and efficiently in planning system operations. This paper presented two approaches using an Adaptive Neuro-Fuzzy Inference System (ANFIS) and an Artificial Neural Network (ANN) to evaluate the power demand. The modified IEEE 57-Bus system is considered the thermal units that incorporate renewables. The ANFIS and ANN are implemented using MATLAB online version R2023b. The results show that the ANN and ANFIS techniques are suitable for evaluating power demand. A comparison of both methods indicates that ANFIS is relatively superior to the ANNs techniques, considering the coefficient of determination of the ANNs and ANFIS were equal. The accuracy of its results in terms of prediction RMSE for the ANN and ANFIS of 10.147e-05 and 5.2177e-05 for the training and 14.639e-05 and 5.2177e-05 for the testing, respectively. Finally, the prediction accuracy of the ANFIS can be observed to be higher than that of the ANN, but the ANFIS takes longer to process. ANFIS is the method that can be appropriately applied to evaluate the power demand in this research. However, it could not guarantee for other research topics that ANFIS would be better than ANN for the RMSE. It depends on input and output data complexity and the training function type.
- Top Cited PapersOpen Access
- 3 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. PP, 1
Advanced Fault Detection, Classification, and Localization in Transmission Lines: A Comparative Study of ANFIS, Neural Networks, and Hybrid Methods
Electric systems are getting more complex with time, and primitive protection methods such as traveling wave and impedance-based methods face limitations and shortcomings. This paper incorporates and presents the applications of an adaptive neuro-fuzzy inference system and compares it with a back propagation neural network, self-organizing map, and hybrid method of discrete wavelet with adaptive neuro-fuzzy inference system for fault detections, classification, and localization in transmission lines. These methods, in comparison with primitive methods, could be capable of detecting, identifying, and predicting the location of the faults more accurately. The IEEE 9-bus system is utilized to obtain data from one end of the transmission line to develop an ANFIS-based model. This system is simulated in MATLAB/Simulink for different fault cases at various locations. The three-phase voltage and current at one end of IEEE 9-bus number seven are taken for training. Three ANFIS models are developed for fault detection, classification, and localization and compared with other models. For verification of the models, mean square error, mean absolute error, and regression analysis have been computed and compared for all the models. All four techniques have performed well for fault classification, detection, and location. However, the percentage error for the ANFIS-based fault model is less compared to backpropagation, self-organizing map, and discrete wavelet transform with ANFIS. Therefore, the proposed ANFIS models can be implemented for deploying in real-time-based protection systems.
- 3 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. PP, 1
Top Cited PapersOpen AccessAdvanced Fault Detection, Classification, and Localization in Transmission Lines: A Comparative Study of ANFIS, Neural Networks, and Hybrid Methods
Electric systems are getting more complex with time, and primitive protection methods such as traveling wave and impedance-based methods face limitations and shortcomings. This paper incorporates and presents the applications of an adaptive neuro-fuzzy inference system and compares it with a back propagation neural network, self-organizing map, and hybrid method of discrete wavelet with adaptive neuro-fuzzy inference system for fault detections, classification, and localization in transmission lines. These methods, in comparison with primitive methods, could be capable of detecting, identifying, and predicting the location of the faults more accurately. The IEEE 9-bus system is utilized to obtain data from one end of the transmission line to develop an ANFIS-based model. This system is simulated in MATLAB/Simulink for different fault cases at various locations. The three-phase voltage and current at one end of IEEE 9-bus number seven are taken for training. Three ANFIS models are developed for fault detection, classification, and localization and compared with other models. For verification of the models, mean square error, mean absolute error, and regression analysis have been computed and compared for all the models. All four techniques have performed well for fault classification, detection, and location. However, the percentage error for the ANFIS-based fault model is less compared to backpropagation, self-organizing map, and discrete wavelet transform with ANFIS. Therefore, the proposed ANFIS models can be implemented for deploying in real-time-based protection systems.
- Open Access
- 12 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 142100-142110
Critical Clearing Time Prediction for Power Transmission Using an Adaptive Neuro-Fuzzy Inference System
An adaptive neuro-fuzzy inference system (ANFIS) is a hybrid algorithm composed of fuzzy logic and an artificial neural network. It takes advantage of fuzzy logic and artificial neural networks to solve complex problems. For power transmission, several dynamic parameters are ignored for conventional transient stability assessment due to the complexity of the equations, and due to the long computational time required. Certainly, it is very difficult to do the real-time assessment of large power systems by considering dynamic impacts in detail. In this paper, an approach is required to increase the accuracy of results. Herein, a method, namely ANFIS, was found to overcome the limitations. All significant effects of dynamics can be taken into account; not only the machine model but also the turbine governor model, automatic voltage regulator (AVR) model, and load characteristic model are carefully considered. In addition, the model used for each generator unit is varied to achieve real conditions. The ANFIS output is the critical clearing time (CCT). CCT values are very important to be correctly predicted for the stability of power systems after clearing the faults. When the faults are cleared by opening the circuit breakers within the CCT values, the power systems are still stable. If the faults are cleared after the CCT values, the systems become unstable. The modified IEEE 9-bus and IEEE 39-bus systems are applied in the implementation of this study. The locations of faults and the levels of loads (except the power system topology changes) are varied for each simulation. The results from the ANFIS application indicate that ANFIS (considering the dynamic effects of the machine models, AVR system, turbine governors, and load characteristics) can predict CCT values with high accuracy. Moreover, when ANFIS results are compared to the artificial neural network (ANN) results, which are generally used, it can be seen that ANFIS results are better and take a lower time for training and testing processes than ANN. ANFIS can be adapted, improved, and implemented in real practice.
- 12 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 142100-142110
Open AccessCritical Clearing Time Prediction for Power Transmission Using an Adaptive Neuro-Fuzzy Inference System
An adaptive neuro-fuzzy inference system (ANFIS) is a hybrid algorithm composed of fuzzy logic and an artificial neural network. It takes advantage of fuzzy logic and artificial neural networks to solve complex problems. For power transmission, several dynamic parameters are ignored for conventional transient stability assessment due to the complexity of the equations, and due to the long computational time required. Certainly, it is very difficult to do the real-time assessment of large power systems by considering dynamic impacts in detail. In this paper, an approach is required to increase the accuracy of results. Herein, a method, namely ANFIS, was found to overcome the limitations. All significant effects of dynamics can be taken into account; not only the machine model but also the turbine governor model, automatic voltage regulator (AVR) model, and load characteristic model are carefully considered. In addition, the model used for each generator unit is varied to achieve real conditions. The ANFIS output is the critical clearing time (CCT). CCT values are very important to be correctly predicted for the stability of power systems after clearing the faults. When the faults are cleared by opening the circuit breakers within the CCT values, the power systems are still stable. If the faults are cleared after the CCT values, the systems become unstable. The modified IEEE 9-bus and IEEE 39-bus systems are applied in the implementation of this study. The locations of faults and the levels of loads (except the power system topology changes) are varied for each simulation. The results from the ANFIS application indicate that ANFIS (considering the dynamic effects of the machine models, AVR system, turbine governors, and load characteristics) can predict CCT values with high accuracy. Moreover, when ANFIS results are compared to the artificial neural network (ANN) results, which are generally used, it can be seen that ANFIS results are better and take a lower time for training and testing processes than ANN. ANFIS can be adapted, improved, and implemented in real practice.
- 2 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 21 (12) , 1291-1305
Artificial Intelligence based Faults Identification, Classification, and Localization Techniques in Transmission Lines-A Review
An overview of the many methods used for fault detection, classification and location in the power system, particularly in transmission lines, is provided in this review, it also includes an experimental result of adaptive neuro-fuzzy inference system -based fault detection , fault classification and fault location. Being in operation outdoor environment, transmission lines are more vulnerable to various faults which may lead to system collapse in severe cases. Therefore, to ensure the reliable and safe operation of power system it is imperative to critically monitor the faults in transmission lines. In this regard, researchers around the globe have developed several techniques and constantly putting efforts to further improve the protection efficacy. The brief yet thorough analysis and comparison of the artificial intelligence-based techniques, hybrid methodologies and most recent approaches in the context of power system faults have been discussed and presented. In addition, the research work and the experimental results of an adaptive neuro-fuzzy inference system-based techniques have also been discussed for IEEE-9 bus system. The mean square error for testing data of ANFIS-based fault detection, classification, is zero and for fault location Mean square error is 5.32km. This piece of work could be helpful in the development of a comprehensive understanding of various artificial intelligence-based techniques within the realm of fault detection, classification and localization in transmission lines.
- 2 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 21 (12) , 1291-1305
Artificial Intelligence based Faults Identification, Classification, and Localization Techniques in Transmission Lines-A Review
An overview of the many methods used for fault detection, classification and location in the power system, particularly in transmission lines, is provided in this review, it also includes an experimental result of adaptive neuro-fuzzy inference system -based fault detection , fault classification and fault location. Being in operation outdoor environment, transmission lines are more vulnerable to various faults which may lead to system collapse in severe cases. Therefore, to ensure the reliable and safe operation of power system it is imperative to critically monitor the faults in transmission lines. In this regard, researchers around the globe have developed several techniques and constantly putting efforts to further improve the protection efficacy. The brief yet thorough analysis and comparison of the artificial intelligence-based techniques, hybrid methodologies and most recent approaches in the context of power system faults have been discussed and presented. In addition, the research work and the experimental results of an adaptive neuro-fuzzy inference system-based techniques have also been discussed for IEEE-9 bus system. The mean square error for testing data of ANFIS-based fault detection, classification, is zero and for fault location Mean square error is 5.32km. This piece of work could be helpful in the development of a comprehensive understanding of various artificial intelligence-based techniques within the realm of fault detection, classification and localization in transmission lines.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Evaluation of Wind Energy Production Using Weibull Distribution and Artificial Neural Networks
Wind turbine power generation planning requires production estimation. Wind power is uncertain depending on the location, wind speed and wind turbine efficiency. This paper presents a method for evaluating wind energy production using Weibull distribution and Artificial neural networks to compare the data recorded by Promthep Alternative Energy Station, Phuket, Thailand. The results show that wind energy estimation using artificial neural networks produces the most accurate results. Mean Absolute Percentage Error is used to determine the minimum error value. Minimal error of training data is 2.524% and the test data is 3.3041%.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Evaluation of Wind Energy Production Using Weibull Distribution and Artificial Neural Networks
Wind turbine power generation planning requires production estimation. Wind power is uncertain depending on the location, wind speed and wind turbine efficiency. This paper presents a method for evaluating wind energy production using Weibull distribution and Artificial neural networks to compare the data recorded by Promthep Alternative Energy Station, Phuket, Thailand. The results show that wind energy estimation using artificial neural networks produces the most accurate results. Mean Absolute Percentage Error is used to determine the minimum error value. Minimal error of training data is 2.524% and the test data is 3.3041%.