Sarah S. L. Chow
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sarah S. L. Chow has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Jonathan T. C. Liu
Stanford University, USA
4 shared publications - Kevin W. Bishop
Department of Mechanical Engineering, University of Washington, Seattle, USA
3 shared publications Andrew Janowczyk
Department of Biomedical Engineering, Emory University, Atlanta, USA
2 shared publicationsElena Baraznenok
Department of Mechanical Engineering, University of Washington, Seattle, USA
2 shared publicationsGan Gao
Department of Mechanical Engineering, University of Washington, Seattle, USA
2 shared publicationsLydia Lan
Department of Mechanical Engineering, University of Washington, Seattle, USA
2 shared publications
Latest Publications
- Open Access
- 1 March 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (03) , 036001-12
Direct three-dimensional segmentation of prostate glands with nnU-Net
Prostate cancer is the most prevalent form of cancer and is the second leading cause of cancer-related deaths among men in the United States.1 Every year, nearly 250,000 men are diagnosed with this disease in the United States. Morbidity and mortality rates are low, but there is a fraction of prostate cancer cases that are potentially lethal and for whom aggressive treatments are warranted. To determine whether a patient requires aggressive treatment, urologists rely heavily upon the Gleason score reported by pathologists. Gleason scoring is based solely on the visual interpretation of prostate gland morphology, as seen on a few 2D histology slides. Unfortunately, there is a high level of interobserver variability associated with Gleason grading of prostate cancer2,3 and the Gleason scores are only moderately correlated with outcomes, particularly for patients with intermediate-grade prostate cancer.4 This can lead to the undertreatment of some patients,5 resulting in preventable metastasis and death,6 and overtreatment of other patients,7 which can lead to financial burdens and avoidable side effects, such as incontinence and impotence.8
- 1 March 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (03) , 036001-12
Open AccessDirect three-dimensional segmentation of prostate glands with nnU-Net
Prostate cancer is the most prevalent form of cancer and is the second leading cause of cancer-related deaths among men in the United States.1 Every year, nearly 250,000 men are diagnosed with this disease in the United States. Morbidity and mortality rates are low, but there is a fraction of prostate cancer cases that are potentially lethal and for whom aggressive treatments are warranted. To determine whether a patient requires aggressive treatment, urologists rely heavily upon the Gleason score reported by pathologists. Gleason scoring is based solely on the visual interpretation of prostate gland morphology, as seen on a few 2D histology slides. Unfortunately, there is a high level of interobserver variability associated with Gleason grading of prostate cancer2,3 and the Gleason scores are only moderately correlated with outcomes, particularly for patients with intermediate-grade prostate cancer.4 This can lead to the undertreatment of some patients,5 resulting in preventable metastasis and death,6 and overtreatment of other patients,7 which can lead to financial burdens and avoidable side effects, such as incontinence and impotence.8
- 23 January 2024
- Published by Springer Nature in Nature Protocols
- Vol. 19 (4) , 1122-1148
An end-to-end workflow for nondestructive 3D pathology
Recent advances in 3D pathology offer the ability to image orders of magnitude more tissue than conventional pathology methods while also providing a volumetric context that is not achievable with 2D tissue sections, and all without requiring destructive tissue sectioning. Generating high-quality 3D pathology datasets on a consistent basis, however, is not trivial and requires careful attention to a series of details during tissue preparation, imaging and initial data processing, as well as iterative optimization of the entire process. Here, we provide an end-to-end procedure covering all aspects of a 3D pathology workflow (using light-sheet microscopy as an illustrative imaging platform) with sufficient detail to perform well-controlled preclinical and clinical studies. Although 3D pathology is compatible with diverse staining protocols and computationally generated color palettes for visual analysis, this protocol focuses on the use of a fluorescent analog of hematoxylin and eosin, which remains the most common stain used for gold-standard pathological reports. We present our guidelines for a broad range of end users (e.g., biologists, clinical researchers and engineers) in a simple format. The end-to-end workflow requires 3–6 d to complete, bearing in mind that data analysis may take longer.
- 23 January 2024
- Published by Springer Nature in Nature Protocols
- Vol. 19 (4) , 1122-1148
An end-to-end workflow for nondestructive 3D pathology
Recent advances in 3D pathology offer the ability to image orders of magnitude more tissue than conventional pathology methods while also providing a volumetric context that is not achievable with 2D tissue sections, and all without requiring destructive tissue sectioning. Generating high-quality 3D pathology datasets on a consistent basis, however, is not trivial and requires careful attention to a series of details during tissue preparation, imaging and initial data processing, as well as iterative optimization of the entire process. Here, we provide an end-to-end procedure covering all aspects of a 3D pathology workflow (using light-sheet microscopy as an illustrative imaging platform) with sufficient detail to perform well-controlled preclinical and clinical studies. Although 3D pathology is compatible with diverse staining protocols and computationally generated color palettes for visual analysis, this protocol focuses on the use of a fluorescent analog of hematoxylin and eosin, which remains the most common stain used for gold-standard pathological reports. We present our guidelines for a broad range of end users (e.g., biologists, clinical researchers and engineers) in a simple format. The end-to-end workflow requires 3–6 d to complete, bearing in mind that data analysis may take longer.
- Open Access
- 2 November 2023
- Published by Wiley in The Journal of Pathology: Clinical Research
- Vol. 10 (1)
Engineering the future of 3D pathology
In recent years, technological advances in tissue preparation, high‐throughput volumetric microscopy, and computational infrastructure have enabled rapid developments in nondestructive 3D pathology, in which high‐resolution histologic datasets are obtained from thick tissue specimens, such as whole biopsies, without the need for physical sectioning onto glass slides. While 3D pathology generates massive datasets that are attractive for automated computational analysis, there is also a desire to use 3D pathology to improve the visual assessment of tissue histology. In this perspective, we discuss and provide examples of potential advantages of 3D pathology for the visual assessment of clinical specimens and the challenges of dealing with large 3D datasets (of individual or multiple specimens) that pathologists have not been trained to interpret. We discuss the need for artificial intelligence triaging algorithms and explainable analysis methods to assist pathologists or other domain experts in the interpretation of these novel, often complex, large datasets.
- 2 November 2023
- Published by Wiley in The Journal of Pathology: Clinical Research
- Vol. 10 (1)
Open AccessEngineering the future of 3D pathology
In recent years, technological advances in tissue preparation, high‐throughput volumetric microscopy, and computational infrastructure have enabled rapid developments in nondestructive 3D pathology, in which high‐resolution histologic datasets are obtained from thick tissue specimens, such as whole biopsies, without the need for physical sectioning onto glass slides. While 3D pathology generates massive datasets that are attractive for automated computational analysis, there is also a desire to use 3D pathology to improve the visual assessment of tissue histology. In this perspective, we discuss and provide examples of potential advantages of 3D pathology for the visual assessment of clinical specimens and the challenges of dealing with large 3D datasets (of individual or multiple specimens) that pathologists have not been trained to interpret. We discuss the need for artificial intelligence triaging algorithms and explainable analysis methods to assist pathologists or other domain experts in the interpretation of these novel, often complex, large datasets.
- 31 October 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (11) , 6048-6059
Miniature line-scanned dual-axis confocal microscope for versatile clinical use
A miniature optical-sectioning fluorescence microscope with high sensitivity and resolution would enable non-invasive and real-time tissue inspection, with potential use cases including early disease detection and intraoperative guidance. Previously, we developed a miniature MEMS-based dual-axis confocal (DAC) microscope that enabled video-rate optically sectioned in vivo microscopy of human tissues. However, the device’s clinical utility was limited due to a small field of view, a non-adjustable working distance, and a lack of a sterilization strategy. In our latest design, we have made improvements to achieve a 2x increase in the field of view (600 × 300 µm) and an adjustable working distance range of 150 µm over a wide range of excitation/emission wavelengths (488–750 nm), all while maintaining a high frame rate of 15 frames per second (fps). Furthermore, the device is designed to image through a disposable sterile plastic drape for convenient clinical use. We rigorously characterize the performance of the device and show example images of ex vivo tissues to demonstrate the optical performance of our new design, including fixed mouse skin and human prostate, as well as fresh mouse kidney, mouse intestine, and human head and neck surgical specimens with corresponding H&E histology. These improvements will facilitate clinical testing and translation.
- 31 October 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (11) , 6048-6059
Miniature line-scanned dual-axis confocal microscope for versatile clinical use
A miniature optical-sectioning fluorescence microscope with high sensitivity and resolution would enable non-invasive and real-time tissue inspection, with potential use cases including early disease detection and intraoperative guidance. Previously, we developed a miniature MEMS-based dual-axis confocal (DAC) microscope that enabled video-rate optically sectioned in vivo microscopy of human tissues. However, the device’s clinical utility was limited due to a small field of view, a non-adjustable working distance, and a lack of a sterilization strategy. In our latest design, we have made improvements to achieve a 2x increase in the field of view (600 × 300 µm) and an adjustable working distance range of 150 µm over a wide range of excitation/emission wavelengths (488–750 nm), all while maintaining a high frame rate of 15 frames per second (fps). Furthermore, the device is designed to image through a disposable sterile plastic drape for convenient clinical use. We rigorously characterize the performance of the device and show example images of ex vivo tissues to demonstrate the optical performance of our new design, including fixed mouse skin and human prostate, as well as fresh mouse kidney, mouse intestine, and human head and neck surgical specimens with corresponding H&E histology. These improvements will facilitate clinical testing and translation.