Sami Ghazaleh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sami Ghazaleh has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Azizullah Beran
Division of Gastroenterology and Hepatology, Indiana University, Indianapolis, IN, USA
3 shared publications Justin Chuang
Department of Internal Medicine, University of Toledo, Toledo, OH
2 shared publications- Aadil Maqsood
Department of Internal Medicine, Pulmonary and Critical Care Medicine, University of Toledo Medical Center, Toledo, OH, United States
1 shared publication Ali Nawras
Division of Gastroenterology and Hepatology, University of Toledo, Toledo, OH
1 shared publicationAmna Iqbal
Department of Internal Medicine, University of Toledo, Toledo, OH
1 shared publicationAzizullah Beran
Department of Internal Medicine, University of Toledo, Toledo, OH
1 shared publication
Latest Publications
- Open Access
- 30 January 2026
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 59 (1) , 49-57
Spiral enteroscopy versus single-balloon enteroscopy for the evaluation and treatment of small bowel disorders: a systematic review and meta-analysis
Background/Aims: Device-assisted enteroscopy has advanced small bowel disorder management. We conducted this meta-analysis to compare the clinical and procedural outcomes between spiral enteroscopy and single-balloon enteroscopy.Methods: A systematic search was performed on December 1, 2024, in the PubMed, Scopus, and Cochrane Library databases to identify studies that compared spiral enteroscopy and single-balloon enteroscopy. The outcomes included diagnostic and therapeutic yields, total procedure time, depth of maximum insertion, and adverse event rates.Results: Five studies (including 496 patients) met the inclusion criteria. The diagnostic yield was similar between spiral enteroscopy and single-balloon enteroscopy (risk ratio [RR], 1.07; 95% confidence interval [CI], 0.96–1.20; p=0.24). The therapeutic yield also showed no significant difference (RR, 1.10; 95% CI, 0.45–2.69; p=0.83). The total procedure time was comparable (mean difference, –22.85 minutes; 95% CI, –46.83 to 1.12; p=0.06), although motorized spiral enteroscopy reduced the procedure time (p<0.001). Spiral enteroscopy achieved greater depth of maximum insertion (standardized mean difference, 1.33; 95% CI, 0.65–2.01; p<0.001). Adverse event rates were comparable (RR, 1.72; 95% CI, 0.80–3.70; p=0.16).Conclusions: Spiral and single-balloon enteroscopies demonstrated similar diagnostic and therapeutic yields and safety. Spiral enteroscopy achieved a greater insertion depth, and motorized systems improved the efficiency in terms of procedure times.
- 30 January 2026
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 59 (1) , 49-57
Open AccessSpiral enteroscopy versus single-balloon enteroscopy for the evaluation and treatment of small bowel disorders: a systematic review and meta-analysis
Background/Aims: Device-assisted enteroscopy has advanced small bowel disorder management. We conducted this meta-analysis to compare the clinical and procedural outcomes between spiral enteroscopy and single-balloon enteroscopy.Methods: A systematic search was performed on December 1, 2024, in the PubMed, Scopus, and Cochrane Library databases to identify studies that compared spiral enteroscopy and single-balloon enteroscopy. The outcomes included diagnostic and therapeutic yields, total procedure time, depth of maximum insertion, and adverse event rates.Results: Five studies (including 496 patients) met the inclusion criteria. The diagnostic yield was similar between spiral enteroscopy and single-balloon enteroscopy (risk ratio [RR], 1.07; 95% confidence interval [CI], 0.96–1.20; p=0.24). The therapeutic yield also showed no significant difference (RR, 1.10; 95% CI, 0.45–2.69; p=0.83). The total procedure time was comparable (mean difference, –22.85 minutes; 95% CI, –46.83 to 1.12; p=0.06), although motorized spiral enteroscopy reduced the procedure time (p<0.001). Spiral enteroscopy achieved greater depth of maximum insertion (standardized mean difference, 1.33; 95% CI, 0.65–2.01; p<0.001). Adverse event rates were comparable (RR, 1.72; 95% CI, 0.80–3.70; p=0.16).Conclusions: Spiral and single-balloon enteroscopies demonstrated similar diagnostic and therapeutic yields and safety. Spiral enteroscopy achieved a greater insertion depth, and motorized systems improved the efficiency in terms of procedure times.
- 8 July 2022
- Published by Wolters Kluwer Health in American Journal of Therapeutics
- Vol. 30 (6) , e591-e594
Comparative Efficacy of Anticoagulant Medications in Nonmalignant Portal Vein Thrombosis in Liver Cirrhosis—A Systematic Review and Network Meta-analysis
- 8 July 2022
- Published by Wolters Kluwer Health in American Journal of Therapeutics
- Vol. 30 (6) , e591-e594
Comparative Efficacy of Anticoagulant Medications in Nonmalignant Portal Vein Thrombosis in Liver Cirrhosis—A Systematic Review and Network Meta-analysis
- 16 June 2022
- Published by Elsevier in Gastroenterology
- Vol. 162 (7)
Mo1316: ASSOCIATION BETWEEN VITAMIN D LEVELS AND HEPATOCELLULAR CARCINOMA: A SYSTEMIC REVIEW AND META-ANALYSIS OF PROSPECTIVE STUDIES
- 16 June 2022
- Published by Elsevier in Gastroenterology
- Vol. 162 (7)
Mo1316: ASSOCIATION BETWEEN VITAMIN D LEVELS AND HEPATOCELLULAR CARCINOMA: A SYSTEMIC REVIEW AND META-ANALYSIS OF PROSPECTIVE STUDIES
- Open Access
PRONE POSITIONING IN NONINTUBATED PATIENTS WITH COVID-19: A SYSTEMATIC REVIEW AND META-ANALYSIS