DCDarius Chapman

Darius Chapman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Darius Chapman has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Multifractal Fluctuations in Electrogram Dynamics Distinguish Atrial Fibrillation Phenotype, Drug Response, and Imminent Termination: Implications for Mechanism and Treatment

    by Darius G Chapman, Campbell Strong, Ivaylo Tonchev, Scott Lorensini, Sobhan Salari Shahrbabaki, Anand Narayan Ganesan

    Structured Background: Atrial fibrillation (AF) is maintained by complex dynamics, clinically characterised by bursting periods of organization and disorganization in intracardiac electrograms. We have previously postulated that cardiac conduction behaves like a critical system, where phase shift from organised rhythm to AF is a phase transition at the critical point. We thus hypothesized that using multifractal analysis of AF electrograms could potentially quantify non-stationary fluctuations, revealing novel mechanistic insights into the cardiac critical system and examine potential clinically relevant markers of AF dynamics, phenotype and treatment response. Objectives: To determine whether multifractal analysis of AF electrograms can (i) Distinguish paroxysmal (PAF0 and non-paroxysmal AF (NPAF), (ii) predict response to pharmacologic modulation, and (iii) identify imminent spontaneous termination, thereby acting as marker of proximity to criticality along complex system phase spectrum. Methods: We analysed >1.4 million seconds of high-density bipolar electrograms from 106 patients (paroxysmal n≈52, non-paroxysmal n≈54) undergoing left atrial mapping with a 24-bipole HD-Grid catheter at standardized sites (RENEWAL AF-ANZCTR ACTRN12619001172190)). Multifractal analysis using the Wavelet Transform Modulus Maxima Method (WTMM) was applied to a burst-energy observable to derive log-normal multifractal parameters c₀ (support dimension), c₁ (spectrum location), and c₂ (fluctuations). Hierarchical mixed-effects models accounted for channels nested within locations within patients. A flecainide sub-study (n=15) provided paired pre-/post-infusion recordings, and 27 spontaneous termination events in 15 patients were analysed using 60-s pre-termination windows. Spatial texture of c₂ was quantified by variogram-derived correlation length and sill. Results: AF electrograms exhibited robust multifractality confirming multifractal fluctuations as an intrinsic property of AF. Non-paroxysmal AF showed significantly reduced fluctuations versus paroxysmal AF (c₂: β=–0.01, p=0.001), indicating a paradoxical loss of fluctuations with disease progression. Flecainide selectively increased fluctuations in paroxysmal AF (Δc₂ = +0.04, p<0.01; Δc₀ = +0.06, p<0.01) but had no significant effect on fluctuations (c2) in non-paroxysmal AF, revealing phenotype-dependent drug response. Immediately prior to spontaneous AF termination, fluctuations increased significantly compared with sustained AF (c₂: 0.198 vs 0.181, p=0.024). Spatial variogram analysis revealed heterogenous patterns in paroxysmal AF, whereas non-paroxysmal AF displayed a homogenised, flattened fluctuations landscape. Conclusions: Atrial fibrillation exhibits robust multifractal dynamics rather than random electrical activity. Reduced fluctuations characterizes non-paroxysmal AF, whereas higher fluctuations is observed in paroxysmal AF, during flecainide modulation, and immediately prior to spontaneous termination. These findings suggest that multifractal fluctuations (c₂) reflects the dynamical state of AF and may serve as a quantitative biomarker of disease progression, pharmacologic responsiveness, and proximity to termination. CONDENSED ABSTRACTT: Atrial fibrillation (AF) exhibits multifractal electrogram fluctuations that vary with disease stage, pharmacologic responsiveness, and proximity to spontaneous termination. In this study, multifractal fluctuations (c₂) was higher in paroxysmal than non-paroxysmal AF, increased selectively with flecainide in paroxysmal AF, and rose immediately before spontaneous termination. These findings identify c₂ as a quantitative marker of AF progression, and imminent reorganization. Clinically, multifractal analysis may enhance intra-procedural assessment of AF phenotype, guide drug selection, and improve recognition of transitions toward sinus rhythm, and connects AF with concepts of criticality and phase transitions.

  • Open Access

    Predicting the spontaneous cardioversion of atrial fibrillation using artificial intelligence–enabled electrocardiography

    by Brandon Wadforth, Sobhan Salari Shahrbabaki, Campbell Strong, Jonathan Karnon, Jing Soong Goh, Luke Phillip O’lOughlin, Ivaylo Tonchev, Lewis Mitchell, Taylor Strube, Scott Lorensini, et al.

    Aims: Spontaneous cardioversion (SCV) is commonly observed in patients presenting to emergency departments (EDs) with primary atrial fibrillation (AF). Predicting SCV could facilitate timely discharge and avoid costly admissions. We sought to evaluate whether SCV could be predicted using artificial intelligence–enabled electrocardiograms (AI-ECGs) and whether this could produce cost savings. Methods and results: We recruited patients presenting to EDs with primary AF throughout 2022–23. Patients were excluded if the outcome of their AF episode was unclear, or the ECG was not accessible. Spontaneous cardioversion prediction was attempted using ResNet50, EfficientNet, and DenseNet convolutional neural network (CNN) architectures and subsequently an ensemble learning model. We then performed a cost-minimization analysis to estimate the cost effect of a prediction-guided ‘wait-and-see’ protocol. There were 1159 presentations to the ED, of which 502 had sufficient data for inclusion. The median age was 74.0 years and 54.0% were women. Spontaneous cardioversion occurred in 227 (45.2%) patients and was more frequent in younger patients (P < 0.001). The ensemble learning model outperformed individual CNNs, achieving an accuracy of 69.7% (SD 5.91) and a receiver operating characteristic area under the curve (ROC AUC) of 0.742 (SD 0.037) with a sensitivity and specificity of 0.736 (SD 0.068) and 0.657 (SD 0.150), respectively. The per patient cost was $4681 if all patients were admitted, which reduced to $3398 with a prediction-guided ‘wait-and-see’ protocol with a 33.3% reduction in overall hospitalization. Conclusion: Artificial intelligence–enabled electrocardiogram can predict SCV in patients presenting to EDs with primary AF, and a prediction-guided ‘wait-and-see’ protocol utilizing AI-ECG could lead to substantial cost savings and reduced hospitalization.


  • Open Access

    Observable Atrial and Ventricular Fibrillation Episode Durations Are Conformant With a Power Law Based on System Size and Spatial Synchronization

    by Dhani Dharmaprani, Kathryn Tiver, Sobhan Salari Shahrbabaki, Evan V. Jenkins, Darius Chapman, Campbell Strong, Jing X. Quah, Ivaylo Tonchev, Luke O’loughlin, Lewis Mitchell, et al.

    BACKGROUND: Atrial fibrillation (AF) and ventricular fibrillation (VF) episodes exhibit varying durations, with some spontaneously ending quickly while others persist. A quantitative framework to explain episode durations remains elusive. We hypothesized that observable self-terminating AF and VF episode lengths, whereby durations are known, would conform with a power law based on the ratio of system size and correlation length ( L / ξ ) . METHODS: Using data from computer simulations (2-dimensional sheet and 3-dimensional left-atrial), human ischemic VF recordings (256-electrode sock, n=12 patients), and human AF recordings (64-electrode basket-catheter, n=9 patients; 16-electrode high definition-grid catheter, n=42 patients), conformance with a power law was assessed using the Akaike information criterion, Bayesian information criterion, coefficient of determination (R 2 , significance= P L / ξ , computed by taking the ratio between system size ( L , chamber/simulation size) and correlation length (xi, estimated from pairwise correlation coefficients over electrode/node distance). RESULTS: In all computer models, the relationship between episode durations and L / ξ was conformant with a power law (Aliev-Panfilov R 2 : 0.90, P 2 : 0.91, P 2 : 0.61, P 2 : 0.86, P 2 : 0.91, P 2 : 0.92, P L / ξ also differentiated between self-terminating and sustained episodes of AF and VF ( P P 0.05). CONCLUSIONS: Observable fibrillation episode durations are conformant with a power law based on system size and correlation length.


  • Open Access

    A comparative study of point-of-care protection from N95 filtering face-piece respirators in a Residential Aged Care Facility and a Tertiary Hospital—Respiratory protection challenges remain amidst long-term impacts of COVID-19

    by Darius Chapman, Campbell Strong, Dhani Dharmaprani, Kathryn Tiver, Prabhpreet Kaur, Anand N. Ganesan

    This study compared the effectiveness of N95 FFRs in providing respiratory protection for healthcare staff in a residential aged care facility (RACF) and tertiary teaching hospital (TTH) who had previously passed their occupational respiratory protection program fit test. A total of 126 healthcare workers who were regularly using N95 FFRs and who had previously passed a fit test participated in this comparative study. In this study, participants were again fit tested with the PortaCount machine, and their self-assessed tolerability of wearing an N95 FFR was assessed using a standardized questionnaire. The main outcome measures included the pass rate of the fit test and the assessment of tolerability and comfort of the N95 FFR. Across all participants, the fit test pass rate was low (27%), indicating persistent gaps in respiratory protection programs for healthcare workers during the ongoing COVID-19 pandemic. Hospital workers were 3.7 times more likely to pass the test compared to their counterparts in RACFs (p < 0.001). It was also found that workers in RACFs reported higher levels of discomfort and overall dissatisfaction with N95 FFRs compared to hospital staff. These findings highlight the need for targeted interventions and improvements in respiratory protection practices beyond annual fit testing, particularly in RACFs, to ensure the safety of healthcare workers and the vulnerable population they serve.


  • Reducing Leak and Increasing Comfort of an N95 Filtering Facepiece Respirator for Aged-Care Workers Using a Customized, Soft, and Compliant Mask Frame

    by Darius Chapman, Campbell Strong, Dhani Dharmaprani, Prabhpreet Kaur, Kathryn Tiver, Anand N. Ganesan

    This prospective cohort study examines the quantitative fit-factor and tolerability impact of a novel custom frame designed to fit beneath N95 filtering facepiece respirators (FFRs) in a healthcare setting. Conducted at a medium-sized metropolitan residential aged care facility (RACF) in South Australia, sixty participants underwent quantitative fit testing while wearing institutional-provided N95 FFRs. Utilizing three-dimensional (3D) face scanning with a proprietary iPhone app, personalized frames were created using flexible silicone foam with a rigid plastic interior “backbone” to ensure compliance and comfort. Following the fitting of custom frames, participants underwent repeat quantitative fit testing using the same style and size of N95 FFRs. Results indicate a remarkable improvement, with 81.5% of participants achieving a pass on quantitative fit testing when using their custom frame in conjunction with the N95 FFRs, compared to a baseline pass rate of only 21.7% (odds ratio (OR) 20.9, 95% confidence interval (CI): 8.26, 58.50, p < 0.001 via logistic regression). Additionally, participants reported a 2.4 times higher level of tolerability when wearing the custom frame with their N95 FFRs compared to using FFRs alone (p < 0.001). In conclusion, the study demonstrates that wearing a customized frame device under an N95 FFR significantly enhances the likelihood of achieving a pass on quantitative fitting and offers a substantially more tolerable experience for wearers. These findings highlight the potential of personalized frame devices to improve respiratory protection efficacy and wearer comfort in healthcare settings.


  • Open Access

    Infra-Red Imaging to Detect Respirator Leak in Healthcare Workers During Fit-Testing Clinic

    by Darius Chapman, Campbell Strong, Kathryn D Tiver, Dhani Dharmaprani, Even Jenkins, Anand N Ganesan

    Objective: This study addressed the problem of objectively detecting leaks in P2 respirators at point of use, an essential component for healthcare workers' protection. To achieve this, we explored the use of infra-red (IR) imaging combined with machine learning algorithms on the thermal gradient across the respirator during inhalation. Results: The study achieved high accuracy in predicting pass or fail outcomes of quantitative fit tests for flat-fold P2 FFRs. The IR imaging methods surpassed the limitations of self fit-checking. Conclusions: The integration of machine learning and IR imaging on the respirator itself demonstrates promise as a more reliable alternative for ensuring the proper fit of P2 respirators. This innovative approach opens new avenues for technology application in occupational hygiene and emphasizes the need for further validation across diverse respirator styles. Significance Statement: Our novel approach leveraging infra-red imaging and machine learning to detect P2 respirator leaks represents a critical advancement in occupational safety and healthcare workers' protection.


  • Open Access

    Personalized 3D-printed frames to reduce leak from N95 filtering facepiece respirators: A prospective crossover trial in health care workers

    by Darius Chapman, Campbell Strong, Shahid Ullah, Lauren Richards, Anand N. Ganesan

    Correctly fitting N95 filtering facepiece respirators (FFRs) have become increasingly important in health care throughout the COVID-19 pandemic. We evaluated the hypothesis that personalized 3-D-printed frames could improve N95 FFRs quantitative fit test pass rates and test scores in health care workers (HCW). HCW were recruited at a tertiary hospital in Adelaide, Australia (ACTRN 12622000388718). A mobile iPhone camera + app was used to produce 3-D scans of volunteers’ faces, which were then imported into a software program to produce personalized virtual scaffolds suited to each user’s face and their unique anatomical features. These virtual scaffolds were printed on a commercially available 3-D printer, producing plastic (and then silicone-coated, biocompatible) frames that can be fitted inside existing hospital supply N95 FFR. The primary endpoint was improved pass rates on quantitative fit testing – comparing participants wearing an N95 FFR alone (control 1) with participants wearing the frame + N95 FFR (intervention 1). The secondary endpoint was the fit factor (FF) in these groups, and R-COMFI respirator comfort and tolerability survey scores. N = 66 HCW were recruited. The use of intervention 1 increased overall fit test pass rates to 62/66 (93.8%), compared to 27/66 (40.9%) for controls. (OR for pFF pass 20.89 (95%CI: 6.77, 64.48, P < 0.001). Average FF increased, with the use of intervention 1 to 179.0 (95%CI: 164.3,193.7), compared to 85.2 (95%CI: 70.4,100.0) with control 1. Pass rates and FF were improved with intervention 1 compared to control 1 for all stages of the fit-test: bending, talking, side-to-side, and up-down motion. (P < 0.001 all stages). Tolerability and comfort of the frame was evaluated with the validated R-COMFI respirator comfort score, showing improvement with the frame compared to N95 FFR alone (P = 0.006). Personalized 3-D-printed face frames decrease leakage, improve fit testing pass rates and FF, and provide improved comfort compared to the N95 FFR alone. Personalized 3-D-printed face frames represent a rapidly scalable new technology to decrease FFR leakage in HCW and potentially the wider population.


  • PO-02-039 THE EFFECT OF PULSED-FIELD ABLATION FIELD STRENGTH AND NUMBER OF APPLICATIONS IN ACUTE PULMONARY VEIN ISOLATION: A PRECLINICAL STUDY

    by Suraya Hani Kamsani, Darius Chapman, Ian Fong, Twins Yiu, Jonathan Ariyaratnam, John Fitzgerald, Bradley Pitman, Prashanthan Sanders, Mehrdad Emami

  • Open Access

    Quantitative respirator fit tests for P2/N95 in Australian general practice

    by Darius Chapman, Lauren Chapman, Anand Ganesan

    The authors report the results of a pilot trial of quantitative N95 respirator mask fit testing in metropolitan general practice and how fit test failures were managed.