Priyanka Dutta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Priyanka Dutta has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
A. Barui
Center for Healthcare Science and Technology, Indian Institute of Engineering Science and Technology 2 , Shibpur 711103, West Bengal, India
1 shared publication- Ananya Chakraborty
Indian Institute of Engineering Science and Technology(IIEST), India
1 shared publication - Anchit Arun
School of VLSI Technology, Indian Institute of Engineering Science and Technology(IIEST), India
1 shared publication - Anukool Yadav
Indian Institute of Technology Kharagpur
1 shared publication - Chirasree RoyChaudhuri
Department of Electronics & Telecommunication Engineering Indian Institute of Engineering Science and Technology Howrah West Bengal India
1 shared publication - Debajyoti Pal
School of Information Technology, KMUTT, Thungkru, Bangkok, Thailand
1 shared publication
Latest Publications
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (17) , 25417-25424
Fully Screen-Printed Flexible Electrochemical Sensor Based on Ti 3 C 2 T x –CuO Nanocomposite for Simultaneous Determination of Dopamine and Uric Acid
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (17) , 25417-25424
Fully Screen-Printed Flexible Electrochemical Sensor Based on Ti 3 C 2 T x –CuO Nanocomposite for Simultaneous Determination of Dopamine and Uric Acid
- Open Access
- 6 December 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-6
Power and Delay Efficient Hardware Implementation with ATPG for Vedic Multiplier Using Urdhva Tiryagbhyam Sutra
In most implementations of digital circuitry, multiplication requires the highest latency and computational complexity. Vedic calculations are an ancient system of mathematics that involves mathematical computations to ascertain the multiplication in faster implementation. In this paper, Urdhva Tiryagbhyam Sutra inspired Vedic Multiplier algorithm is used for multiplication rather than conventional multiplication, enabling simple and quick computation with limited hardware resources. 99.329% fault coverage was achieved using the ATALANTA tool, and the results after incorporating Automatic Test Pattern Generation (ATPG) are encouraging. The synthesis and functional verification of the proposed arithmetic circuit are carried out in Quartus Prime and the ModelSim 20.1 Intel simulator, respectively. Additionally, the latency and power consumption obtained are 7.89 ns and 0.164 nW, respectively, which is significantly less than the current designs. By using a fault collapsing technique with no aborted faults, 298 collapsed faults, 2 backtrackings, 33 test patterns before compactions, and a minimum of 20 test patterns after compactions, the design testing time is reduced.
- 6 December 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-6
Open AccessPower and Delay Efficient Hardware Implementation with ATPG for Vedic Multiplier Using Urdhva Tiryagbhyam Sutra
In most implementations of digital circuitry, multiplication requires the highest latency and computational complexity. Vedic calculations are an ancient system of mathematics that involves mathematical computations to ascertain the multiplication in faster implementation. In this paper, Urdhva Tiryagbhyam Sutra inspired Vedic Multiplier algorithm is used for multiplication rather than conventional multiplication, enabling simple and quick computation with limited hardware resources. 99.329% fault coverage was achieved using the ATALANTA tool, and the results after incorporating Automatic Test Pattern Generation (ATPG) are encouraging. The synthesis and functional verification of the proposed arithmetic circuit are carried out in Quartus Prime and the ModelSim 20.1 Intel simulator, respectively. Additionally, the latency and power consumption obtained are 7.89 ns and 0.164 nW, respectively, which is significantly less than the current designs. By using a fault collapsing technique with no aborted faults, 298 collapsed faults, 2 backtrackings, 33 test patterns before compactions, and a minimum of 20 test patterns after compactions, the design testing time is reduced.
- Open Access
- 6 November 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (19)
A direct MIP-interfaced FET sensor for sensitive, selective, and real time biomolecule detection in unamplified samples: Toward POC bioelectronic transduction
Diverse efforts undertaken to mitigate the Debye screening effect of field-effect transistor (FET) biosensors have achieved higher sensitivity. However, the charge transfer or induction mechanism between the captured biomolecules and the sensing surface, resulting in shift of surface potential and, hence, the drain current magnitude, shows poor selectivity for real time detection of ultra-low biomolecule concentration in unamplified samples. Herein, enabling direct interaction of the target molecule with edge passivated thermally reduced graphene oxide, through the template of molecularly imprinted polymer (MIP), specific trap induced characteristic bulges in the noise spectrum has been observed only in the presence of target molecule. Such a phenomenon has not been observed either with antibodies or aptamers as receptors. Hence, the direct interface of MIP with a graphene FET (GFET) results in the generation of an additional electronic label in FET transduction. As a proof of concept, this principle has been validated for serotonin detection in serum in the presence of other neurotransmitters, resulting in detection limit of 0.05 fM in real time, which is more than two orders of magnitude lower than existing reports and, hence, is expected to pave the way for advancing GFET based sensors toward ultrasensitive point-of-care applications without requiring complex machine learning algorithms.
- 6 November 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (19)
Open AccessA direct MIP-interfaced FET sensor for sensitive, selective, and real time biomolecule detection in unamplified samples: Toward POC bioelectronic transduction
Diverse efforts undertaken to mitigate the Debye screening effect of field-effect transistor (FET) biosensors have achieved higher sensitivity. However, the charge transfer or induction mechanism between the captured biomolecules and the sensing surface, resulting in shift of surface potential and, hence, the drain current magnitude, shows poor selectivity for real time detection of ultra-low biomolecule concentration in unamplified samples. Herein, enabling direct interaction of the target molecule with edge passivated thermally reduced graphene oxide, through the template of molecularly imprinted polymer (MIP), specific trap induced characteristic bulges in the noise spectrum has been observed only in the presence of target molecule. Such a phenomenon has not been observed either with antibodies or aptamers as receptors. Hence, the direct interface of MIP with a graphene FET (GFET) results in the generation of an additional electronic label in FET transduction. As a proof of concept, this principle has been validated for serotonin detection in serum in the presence of other neurotransmitters, resulting in detection limit of 0.05 fM in real time, which is more than two orders of magnitude lower than existing reports and, hence, is expected to pave the way for advancing GFET based sensors toward ultrasensitive point-of-care applications without requiring complex machine learning algorithms.