RGRajdeep Ganguly

Rajdeep Ganguly

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rajdeep Ganguly has a total of 23 co-authors. Here are the top co-authors by number of shared publications:

  • Ajit Kumar Mahapatra

    Molecular Sensor and Supramolecular Chemistry Laboratory, Department of Chemistry, Indian Institute of Engineering Science and Technology, Shibpur, Howrah-711103, West Bengal, India

    2 shared publications
  • Anirban Karak

    Molecular Sensor and Supramolecular Chemistry Laboratory, Department of Chemistry, Indian Institute of Engineering Science and Technology, Howrah, Shibpur, West Bengal 711103, India

    2 shared publications
  • Anwesha Maiti

    Molecular Sensor and Supramolecular Chemistry Laboratory, Department of Chemistry, Indian Institute of Engineering Science and Technology, Howrah, Shibpur, West Bengal 711103, India

    2 shared publications
  • Pintu Ghosh

    Molecular Sensor and Supramolecular Chemistry Laboratory, Department of Chemistry, Indian Institute of Engineering Science and Technology, Howrah, Shibpur, West Bengal 711103, India

    2 shared publications
  • A. Barui

    Center for Healthcare Science and Technology, Indian Institute of Engineering Science and Technology 2 , Shibpur 711103, West Bengal, India

    1 shared publication
  • Aindrila Roy

    Department of Electronic Science, University of Calcutta, Kolkata, India

    1 shared publication

Latest Publications

  • Investigating the Impact of Noble Metal Nanoparticle Decorated Electrodes on Electrochemical Sensing of Hemoglobin

    by Aindrila Roy, Baishali Basak, Rajdeep Ganguly, Subhadip Chakraborty, Ananya Barui, Rajen Haldar, Sanatan Chattopadhyay

    The work explores the interactions of hemoglobin (Hb) with noble metal nanoparticles (NPs) to probe its redox activity. Screen-printed electrodes (SPEs) modified with Au, Pt, and Pd NPs exhibit significant improvement in the electrochemical signals of Hb. Differential pulse voltammetry measurements show maximum Fe3+ reduction currents of Hb using AuNP/SPE. Such response is attributed to NP-induced conformational changes in Hb. Fourier transform infrared spectroscopy reveals that NPs promote protein unfolding, which leads to exposure of the iron-containing heme group from the hydrophobic pockets of Hb. Surface tension and contact angle analysis of Hb further support such observation. AuNPs induce maximum conformational alterations in Hb, consequently facilitating effective electron transport.

  • Near-Infrared Fluorescent Turn-On Probe for Selective Detection of Hypochlorite in Aqueous Medium and Live Cell Imaging

    by Anwesha Maiti, Saikat Kumar Manna, Satyajit Halder, Rajdeep Ganguly, Anirban Karak, Pintu Ghosh, Kuladip Jana, Ajit Kumar Mahapatra

    Hypochlorite, as an important reactive oxygen species (ROS), plays a vital role in many physiological and pathological processes, but an excess concentration of hypochlorite (ClO-) may become toxic to humans and cause disease. Hence, the selective and rapid detection of hypochlorite (ClO-) is necessary for human safety. Here, we report a novel near-infrared (NIR) fluorescence "turn-on" and highly selective benzophenoxazinium chloride-based fluorescent probe, BPH (benzophenoxazinium dihydroxy benzaldehyde), for hypochlorite detection. Due to hypochlorite-induced vicinal diol oxidation to the corresponding ortho benzoquinone derivative, the photoinduced electron transfer (PET) process, which was operating from vicinal diol to the benzophenoxazinium chloride receptor moiety, was suddenly inhibited, as a result of which strong NIR fluorescence "turn-on" emission was observed. The detection limit of BPH was found to be 2.39 × 10-10 M, or 0.23 nM. BPH was successfully applied for exogenous and endogenous hypochlorite detection in live MDA-MB 231 cells.


  • A Phenanthrenequinone-Based Ratiometric Fluorescent Probe for Rapid Detection of Peroxynitrite with Imaging in Osteoblast Precursor Cells

    by Anirban Karak, Dipanjan Banik, Rajdeep Ganguly, Shilpita Banerjee, Pintu Ghosh, Anwesha Maiti, Debasish Mandal, Ajit Kumar Mahapatra

    In the current situation, peroxynitrite (ONOO-) is drawing the increasing attention of researchers for its pivotal role in diverse pathological and physiological processes on grounds of robust oxidation and nitrification. Herein, we have successfully designed and synthesized a phenanthrenequinone benzyl borate-based chemosensor for fast and selective detection of ONOO-. The probe PTDP itself had an orange fluorescence, which was changed to strong blue fluorescence upon the addition of ONOO-, indicating the ratiometric response of the probe. This is so because of the cleavage of the benzyl boronate-protecting group of PTDP upon the addition of ONOO- with simultaneous releasing of pyridinyl-based chemosensor PPI. The PTDP showed outstanding performance in the various photophysical studies such as good selectivity, excellent sensitivity with a very low detection limit of 2.74 nM, and a very fast response time (<15 s). Furthermore, for practical applicability, it was successfully applied in the ratiometric detection of ONOO- in osteoblast precursor cells.


  • Open Access

    A direct MIP-interfaced FET sensor for sensitive, selective, and real time biomolecule detection in unamplified samples: Toward POC bioelectronic transduction

    by P. Mukherjee, P. Dutta, K. Sinha, S. Sen, T. Shirke, R. Ganguly, A. Barui, C. RoyChaudhuri

    Diverse efforts undertaken to mitigate the Debye screening effect of field-effect transistor (FET) biosensors have achieved higher sensitivity. However, the charge transfer or induction mechanism between the captured biomolecules and the sensing surface, resulting in shift of surface potential and, hence, the drain current magnitude, shows poor selectivity for real time detection of ultra-low biomolecule concentration in unamplified samples. Herein, enabling direct interaction of the target molecule with edge passivated thermally reduced graphene oxide, through the template of molecularly imprinted polymer (MIP), specific trap induced characteristic bulges in the noise spectrum has been observed only in the presence of target molecule. Such a phenomenon has not been observed either with antibodies or aptamers as receptors. Hence, the direct interface of MIP with a graphene FET (GFET) results in the generation of an additional electronic label in FET transduction. As a proof of concept, this principle has been validated for serotonin detection in serum in the presence of other neurotransmitters, resulting in detection limit of 0.05 fM in real time, which is more than two orders of magnitude lower than existing reports and, hence, is expected to pave the way for advancing GFET based sensors toward ultrasensitive point-of-care applications without requiring complex machine learning algorithms.