Zheng Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zheng Wang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Zhenmin Zhao
Department of Plastic Surgery, Peking University Third Hospital, Beijing, China
2 shared publications - Guanhuier Wang
Department of Plastic Surgery, Peking University Third Hospital, Beijing, China
1 shared publication - Mengying Jin
Department of Plastic Surgery, Peking University Third Hospital, Beijing, China
1 shared publication - Pengbing Ding
Peking University Third Hospital, China
1 shared publication - Si-Qiao Wu
Department of Plastic Surgery, Peking University Third Hospital, Beijing, China
1 shared publication - Yang An
Department of Plastic Surgery, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191, China
1 shared publication
Latest Publications
- Open Access
- 10 February 2025
- Published by MDPI AG in Preprints.org
Retinoic Acid Promotes Osteogenic Differentiation of Mesenchymal Stem Cells in the Mouse Facial Suture Under Mechanical Stretching via Piezo2
Trans-sutural Distraction Osteogenesis (TSDO) is a common surgical method for treating facial hypoplasia in secondary cleft lip and palate. Its mechanism involves utilizing mechanical traction to induce the differentiation of mesenchymal stem cells(MSCs) within the facial cleft into osteoblasts. Retinoic acid (RA) is involved in various life processes and promotes osteogenic differentiation under low-dose conditions. However, the impact of RA treatment on stem cells differentiation under mechanical force is unclear. To investigate this mechanism, we performed cell stretching experiment on MSCs that isolated from the mouse facial suture for 2 hours and 3 days alone or supplemented with RA. RNA-seq data showed that mechanical stretching induced the expression of osteogenic-related transcription factors. More importantly, the induction of genes involved in TGFβ/ BMP and WNT signaling pathways was significantly increased upon RA and mechanical stretching co-treatment. Simultaneously, Gene Ontology (GO) enrichment analysis revealed that differentially expressed genes (DEGs) in these co-treatment samples were enriched in the biological process “osteogenic differentiation”. Transcriptomic profiling revealed Piezo2 (mechanosensitive ion channel) as a differentially expressed gene (DEG, p < 0.0001; Log2 (Fold Change) = 4.91). This finding was corroborated by in vitro mechanostimulation assays and in vivo RA-treated murine models, which exhibited 8.38-fold upregulation of Piezo2 mRNA (p < 0.001) compared to untreated controls. After knockout of the Piezo2 gene in MSCs, the cells were subjected to in vitro stretching under osteogenic induction conditions. The formation of calcium nodules in the retinoic acid (RA) treatment group was significantly enhanced compared with the control group. These results indicate that RA putatively promotes osteogenic differentiation under mechanical stretching via Piezo2.
- 10 February 2025
- Published by MDPI AG in Preprints.org
Open AccessRetinoic Acid Promotes Osteogenic Differentiation of Mesenchymal Stem Cells in the Mouse Facial Suture Under Mechanical Stretching via Piezo2
Trans-sutural Distraction Osteogenesis (TSDO) is a common surgical method for treating facial hypoplasia in secondary cleft lip and palate. Its mechanism involves utilizing mechanical traction to induce the differentiation of mesenchymal stem cells(MSCs) within the facial cleft into osteoblasts. Retinoic acid (RA) is involved in various life processes and promotes osteogenic differentiation under low-dose conditions. However, the impact of RA treatment on stem cells differentiation under mechanical force is unclear. To investigate this mechanism, we performed cell stretching experiment on MSCs that isolated from the mouse facial suture for 2 hours and 3 days alone or supplemented with RA. RNA-seq data showed that mechanical stretching induced the expression of osteogenic-related transcription factors. More importantly, the induction of genes involved in TGFβ/ BMP and WNT signaling pathways was significantly increased upon RA and mechanical stretching co-treatment. Simultaneously, Gene Ontology (GO) enrichment analysis revealed that differentially expressed genes (DEGs) in these co-treatment samples were enriched in the biological process “osteogenic differentiation”. Transcriptomic profiling revealed Piezo2 (mechanosensitive ion channel) as a differentially expressed gene (DEG, p < 0.0001; Log2 (Fold Change) = 4.91). This finding was corroborated by in vitro mechanostimulation assays and in vivo RA-treated murine models, which exhibited 8.38-fold upregulation of Piezo2 mRNA (p < 0.001) compared to untreated controls. After knockout of the Piezo2 gene in MSCs, the cells were subjected to in vitro stretching under osteogenic induction conditions. The formation of calcium nodules in the retinoic acid (RA) treatment group was significantly enhanced compared with the control group. These results indicate that RA putatively promotes osteogenic differentiation under mechanical stretching via Piezo2.
- 6 November 2023
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 48 (6) , 1084-1093
A Safe Technique for Excising the Perpendicular Plate of the Ethmoid Bone in Patients with Crooked Nose: A Finite Element Analysis
Background Correction of the crooked nose, especially the perpendicular plate of the ethmoid bone, has the potential to cause skull base injury. At present, the safe and effective method for perpendicular plate resection has not been clearly defined through biomechanics. Method CT scan data of 48 patients with crooked nose and deviated nasal septum were divided into C-type, angular deformity-type, and S-type based on the morphology of the 3D model. Different types of finite element models of the nasal bony septum and skull base were established. The osteotomy depth, angle, and force mode of the PPE resection were simulated by assembling different working conditions for the models. The von Mises stress of the anterior cranial fossa was observed. Results When the osteotomy line length was 0.5 cm, the angle was at 30° to the Frankfurt plane, and 50 N·mm torque was applied, the von Mises stress of the skull base was minimal in the four models, showing 0.049 MPa (C-type), 0.082 MPa (S-type), 0.128 MPa (angular deformity-type), and 0.021 MPa (control model). The maximum von Mises stress values were found at the skull base when the osteotomy line was 1.5 cm, the angle was 50°, and the force was 10 N along the X-axis, showing 0.349 MPa (C-type), 0.698 MPa (S-type), 0.451 MPa (angular deformity-type), and 0.149 MPa (control model). Conclusion The use of smaller resection angle with the Frankfurt plane, conservative resection depth, and torsion force can better reduce the stress value at the skull base and reduce the risk of basicranial fracture. It is a safe and effective technique for perpendicular plate resection of the ethmoid bone in the correction of crooked nose. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.
- 6 November 2023
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 48 (6) , 1084-1093
A Safe Technique for Excising the Perpendicular Plate of the Ethmoid Bone in Patients with Crooked Nose: A Finite Element Analysis
Background Correction of the crooked nose, especially the perpendicular plate of the ethmoid bone, has the potential to cause skull base injury. At present, the safe and effective method for perpendicular plate resection has not been clearly defined through biomechanics. Method CT scan data of 48 patients with crooked nose and deviated nasal septum were divided into C-type, angular deformity-type, and S-type based on the morphology of the 3D model. Different types of finite element models of the nasal bony septum and skull base were established. The osteotomy depth, angle, and force mode of the PPE resection were simulated by assembling different working conditions for the models. The von Mises stress of the anterior cranial fossa was observed. Results When the osteotomy line length was 0.5 cm, the angle was at 30° to the Frankfurt plane, and 50 N·mm torque was applied, the von Mises stress of the skull base was minimal in the four models, showing 0.049 MPa (C-type), 0.082 MPa (S-type), 0.128 MPa (angular deformity-type), and 0.021 MPa (control model). The maximum von Mises stress values were found at the skull base when the osteotomy line was 1.5 cm, the angle was 50°, and the force was 10 N along the X-axis, showing 0.349 MPa (C-type), 0.698 MPa (S-type), 0.451 MPa (angular deformity-type), and 0.149 MPa (control model). Conclusion The use of smaller resection angle with the Frankfurt plane, conservative resection depth, and torsion force can better reduce the stress value at the skull base and reduce the risk of basicranial fracture. It is a safe and effective technique for perpendicular plate resection of the ethmoid bone in the correction of crooked nose. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.