Prasit Tansangworn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Prasit Tansangworn has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Kanokpat Wachirasirikul
Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen 40002, Thailand
2 shared publications - Puengjai Punikhom
Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen 40002, Thailand
2 shared publications - Thawatchai Prabsattroo
Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen 40002, Thailand
2 shared publications - Waraporn Sudchai
Nuclear Technology Service Center, Thailand Institute of Nuclear Technology, Nakorn Nayok 26120, Thailand
2 shared publications
Latest Publications
- Open Access
- 28 November 2023
- Published by MDPI AG in Journal of Imaging
- Vol. 9 (12) , 264
The Dose Optimization and Evaluation of Image Quality in the Adult Brain Protocols of Multi-Slice Computed Tomography: A Phantom Study
Computed tomography examinations have caused high radiation doses for patients, especially for CT scans of the brain. This study aimed to optimize the radiation dose and image quality in adult brain CT protocols. Images were acquired using a Catphan 700 phantom. Radiation doses were recorded as CTDIvol and dose length product (DLP). CT brain protocols were optimized by varying parameters such as kVp, mAs, signal-to-noise ratio (SNR) level, and Clearview iterative reconstruction (IR). The image quality was also evaluated using AutoQA Plus v.1.8.7.0 software. CT number accuracy and linearity had a robust positive correlation with the linear attenuation coefficient (µ) and showed more inaccurate CT numbers when using 80 kVp. The modulation transfer function (MTF) showed a higher value in 100 and 120 kVp protocols (p < 0.001), while high-contrast spatial resolution showed a higher value in 80 and 100 kVp protocols (p < 0.001). Low-contrast detectability and the contrast-to-noise ratio (CNR) tended to increase when using high mAs, SNR, and the Clearview IR protocol. Noise decreased when using a high radiation dose and a high percentage of Clearview IR. CTDIvol and DLP were increased with increasing kVp, mAs, and SNR levels, while the increasing percentage of Clearview did not affect the radiation dose. Optimized protocols, including radiation dose and image quality, should be evaluated to preserve diagnostic capability. The recommended parameter settings include kVp set between 100 and 120 kVp, mAs ranging from 200 to 300 mAs, SNR level within the range of 0.7–1.0, and an iterative reconstruction value of 30% Clearview to 60% or higher.
- 28 November 2023
- Published by MDPI AG in Journal of Imaging
- Vol. 9 (12) , 264
Open AccessThe Dose Optimization and Evaluation of Image Quality in the Adult Brain Protocols of Multi-Slice Computed Tomography: A Phantom Study
Computed tomography examinations have caused high radiation doses for patients, especially for CT scans of the brain. This study aimed to optimize the radiation dose and image quality in adult brain CT protocols. Images were acquired using a Catphan 700 phantom. Radiation doses were recorded as CTDIvol and dose length product (DLP). CT brain protocols were optimized by varying parameters such as kVp, mAs, signal-to-noise ratio (SNR) level, and Clearview iterative reconstruction (IR). The image quality was also evaluated using AutoQA Plus v.1.8.7.0 software. CT number accuracy and linearity had a robust positive correlation with the linear attenuation coefficient (µ) and showed more inaccurate CT numbers when using 80 kVp. The modulation transfer function (MTF) showed a higher value in 100 and 120 kVp protocols (p < 0.001), while high-contrast spatial resolution showed a higher value in 80 and 100 kVp protocols (p < 0.001). Low-contrast detectability and the contrast-to-noise ratio (CNR) tended to increase when using high mAs, SNR, and the Clearview IR protocol. Noise decreased when using a high radiation dose and a high percentage of Clearview IR. CTDIvol and DLP were increased with increasing kVp, mAs, and SNR levels, while the increasing percentage of Clearview did not affect the radiation dose. Optimized protocols, including radiation dose and image quality, should be evaluated to preserve diagnostic capability. The recommended parameter settings include kVp set between 100 and 120 kVp, mAs ranging from 200 to 300 mAs, SNR level within the range of 0.7–1.0, and an iterative reconstruction value of 30% Clearview to 60% or higher.
- Open Access
- 7 November 2023
- Published by MDPI AG in Preprints.org
Dose Optimization and Evaluation of Image Quality in Adult Brain Protocol of Multislice Computed Tomography: A Phantom Study
Background: Computed tomography examinations have produced high radiation doses to patients, especially the CT brain. This study aimed to optimize the radiation dose and image quality in adult CT brain protocol. Materials and Methods: Images were acquired by Catphan 700 phantom. Radiation doses were recorded as CTDIvol and dose length product (DLP). CT brain protocols were optimized by varying parameters such as kVp, mAs, signal-to-noise ratio (SNR) level, and Clearview iterative reconstruction (IR). Image quality were also evaluataion by The AutoQA Plus software. Results: CT Number accuracy and linearity had a robust positive correlation with the linear attenuation coefficient (µ) and showed more inaccurate CT numbers when using 80 kVp. MTF showed a higher value in 100 and 120 kVp protocols, while high contrast spatial resolution showed a higher value in 80 and 100 kVp protocols. Low contrast detectability and CNR tended to increase when using high mAs, SNR and Clearview IR protocol. Noise decreased when using a high radiation dose and a high percentage of Clearview IR. CTDIvol and DLP were increased with increasing kVp, mAs, and SNR levels, while the increasing percentage of Clearview did not affect the radiation dose. Conclusion: Optimized protocols, including radiation dose and image quality, should be evaluated to preserve diagnostic capability. The recommended parameter settings include kVp set between 100-120 kVp, mAs ranging from 200-300 mAs, SNR level within the range of 0.7-1.0, and an iterative reconstruction value of 30% Clearview to 60% or higher.
- 7 November 2023
- Published by MDPI AG in Preprints.org
Open AccessDose Optimization and Evaluation of Image Quality in Adult Brain Protocol of Multislice Computed Tomography: A Phantom Study
Background: Computed tomography examinations have produced high radiation doses to patients, especially the CT brain. This study aimed to optimize the radiation dose and image quality in adult CT brain protocol. Materials and Methods: Images were acquired by Catphan 700 phantom. Radiation doses were recorded as CTDIvol and dose length product (DLP). CT brain protocols were optimized by varying parameters such as kVp, mAs, signal-to-noise ratio (SNR) level, and Clearview iterative reconstruction (IR). Image quality were also evaluataion by The AutoQA Plus software. Results: CT Number accuracy and linearity had a robust positive correlation with the linear attenuation coefficient (µ) and showed more inaccurate CT numbers when using 80 kVp. MTF showed a higher value in 100 and 120 kVp protocols, while high contrast spatial resolution showed a higher value in 80 and 100 kVp protocols. Low contrast detectability and CNR tended to increase when using high mAs, SNR and Clearview IR protocol. Noise decreased when using a high radiation dose and a high percentage of Clearview IR. CTDIvol and DLP were increased with increasing kVp, mAs, and SNR levels, while the increasing percentage of Clearview did not affect the radiation dose. Conclusion: Optimized protocols, including radiation dose and image quality, should be evaluated to preserve diagnostic capability. The recommended parameter settings include kVp set between 100-120 kVp, mAs ranging from 200-300 mAs, SNR level within the range of 0.7-1.0, and an iterative reconstruction value of 30% Clearview to 60% or higher.