Shiyu Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shiyu Zhang has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Jiashu Zhang
Department of Neurosurgery, The First Medical Center of Chinese PLA General Hospital, Beijing 100853, China
4 shared publications - Xiaolei Chen
Department of Neurosurgery, the First Medical Center, Chinese PLA General Hospital, Beijing, China
4 shared publications - Ziyu Qi
University of Marburg,Department of Neurosurgery,Marburg,Germany
4 shared publications - Christopher Nimsky
Department of Neurosurgery, Philipps-University Marburg, Marburg, Germany
3 shared publications - Miriam Helen Anna Bauer
Department of Neurosurgery, University Hospital Marburg, Philipps University Marburg, Baldingerstrasse, 35043 Marburg, Germany
3 shared publications - Zhichao Gan
Department of Neurosurgery, The First Medical Center of Chinese PLA General Hospital, Beijing 100853, China
3 shared publications
Latest Publications
- 26 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 76-84
A Novel Hybrid Conical-Linear Laser Registration Method for Mixed Reality Navigation
Mixed Reality Navigation (MRN) has been proposed as a low-cost and intuitive alternative to conventional navigation systems, yet its adoption remains limited by registration inaccuracy and strong user dependence. This work presents a Hybrid Conical-Linear Laser Registration (HCLR) method that combines a conical projection onto five coplanar fiducials with a single linear-laser constraint to recover all six degrees of freedom analytically. A systematic evaluation of 57 marker layouts identified three robust configurations, which were tested in simulated scenarios using clinical CT and MRI datasets from 19 patients. Under realistic noise conditions, HCLR achieved a mean target registration error (TRE) of 1.06 mm compared with 2.57 mm for standard fiducial-based registration, and nearly eliminated rotation errors. These findings demonstrate that HCLR can improve registration accuracy, reduce operator dependence, and provide a compact, hardware-light solution for MRN. With further physical and clinical validation, HCLR has the potential to advance cost-effective neurosurgical navigation.
- 26 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 76-84
A Novel Hybrid Conical-Linear Laser Registration Method for Mixed Reality Navigation
Mixed Reality Navigation (MRN) has been proposed as a low-cost and intuitive alternative to conventional navigation systems, yet its adoption remains limited by registration inaccuracy and strong user dependence. This work presents a Hybrid Conical-Linear Laser Registration (HCLR) method that combines a conical projection onto five coplanar fiducials with a single linear-laser constraint to recover all six degrees of freedom analytically. A systematic evaluation of 57 marker layouts identified three robust configurations, which were tested in simulated scenarios using clinical CT and MRI datasets from 19 patients. Under realistic noise conditions, HCLR achieved a mean target registration error (TRE) of 1.06 mm compared with 2.57 mm for standard fiducial-based registration, and nearly eliminated rotation errors. These findings demonstrate that HCLR can improve registration accuracy, reduce operator dependence, and provide a compact, hardware-light solution for MRN. With further physical and clinical validation, HCLR has the potential to advance cost-effective neurosurgical navigation.
- Open Access
- 7 March 2025
- Published by MDPI AG in Preprints.org
Development and Clinical Validation of a Low-Cost Dual Kinect-V2-Based Digital Gait Analysis System for Neurological Gait Disorders
Gait disorders are common in neurological diseases and significantly impact patients’ quality of life. While quantitative gait analysis is essential for diagnosis and rehabilitation, existing commercial systems are costly and complex, limiting their clinical application. This study developed a low-cost digital gait analysis system, "Dual Kinect-V2 System (DKS)," integrating dual Kinect-V2 sensors and open-source software to improve accessibility and feasibility in clinical and domestic settings. The system was validated against a commercial insole-based gait analysis system, Right Gait & Posture (RGP) system, in a study involving 18 healthy adults and 15 patients with neurological gait disorders. Spatial-temporal gait parameters were analyzed using Pearson’s correlation coefficient and concordance correlation coefficient to assess consistency. Results demonstrated good to excellent agreement for most spatial-temporal gait parameters, particularly in healthy participants. However, temporal parameters such as double-support, swing, and stance phases exhibited moderate agreement, with greater discrepancies observed in patients. Despite these limitations, the system provides a cost-effective, portable, and relatively accurate tool for clinical gait assessment. With further optimization, including improved motion tracking algorithms and potential sensor upgrades, the system could be a valuable tool for neurological diagnosis, rehabilitation monitoring, and fall prevention in elderly populations.
- 7 March 2025
- Published by MDPI AG in Preprints.org
Open AccessDevelopment and Clinical Validation of a Low-Cost Dual Kinect-V2-Based Digital Gait Analysis System for Neurological Gait Disorders
Gait disorders are common in neurological diseases and significantly impact patients’ quality of life. While quantitative gait analysis is essential for diagnosis and rehabilitation, existing commercial systems are costly and complex, limiting their clinical application. This study developed a low-cost digital gait analysis system, "Dual Kinect-V2 System (DKS)," integrating dual Kinect-V2 sensors and open-source software to improve accessibility and feasibility in clinical and domestic settings. The system was validated against a commercial insole-based gait analysis system, Right Gait & Posture (RGP) system, in a study involving 18 healthy adults and 15 patients with neurological gait disorders. Spatial-temporal gait parameters were analyzed using Pearson’s correlation coefficient and concordance correlation coefficient to assess consistency. Results demonstrated good to excellent agreement for most spatial-temporal gait parameters, particularly in healthy participants. However, temporal parameters such as double-support, swing, and stance phases exhibited moderate agreement, with greater discrepancies observed in patients. Despite these limitations, the system provides a cost-effective, portable, and relatively accurate tool for clinical gait assessment. With further optimization, including improved motion tracking algorithms and potential sensor upgrades, the system could be a valuable tool for neurological diagnosis, rehabilitation monitoring, and fall prevention in elderly populations.
- Open Access
The Feasibility and Accuracy of Holographic Navigation with Laser Crosshair Simulator Registration on a Mixed-Reality Display
Addressing conventional neurosurgical navigation systems’ high costs and complexity, this study explores the feasibility and accuracy of a simplified, cost-effective mixed reality navigation (MRN) system based on a laser crosshair simulator (LCS). A new automatic registration method was developed, featuring coplanar laser emitters and a recognizable target pattern. The workflow was integrated into Microsoft’s HoloLens-2 for practical application. The study assessed the system’s precision by utilizing life-sized 3D-printed head phantoms based on computed tomography (CT) or magnetic resonance imaging (MRI) data from 19 patients (female/male: 7/12, average age: 54.4 ± 18.5 years) with intracranial lesions. Six to seven CT/MRI-visible scalp markers were used as reference points per case. The LCS-MRN’s accuracy was evaluated through landmark-based and lesion-based analyses, using metrics such as target registration error (TRE) and Dice similarity coefficient (DSC). The system demonstrated immersive capabilities for observing intracranial structures across all cases. Analysis of 124 landmarks showed a TRE of 3.0 ± 0.5 mm, consistent across various surgical positions. The DSC of 0.83 ± 0.12 correlated significantly with lesion volume (Spearman rho = 0.813, p < 0.001). Therefore, the LCS-MRN system is a viable tool for neurosurgical planning, highlighting its low user dependency, cost-efficiency, and accuracy, with prospects for future clinical application enhancements.
Open AccessThe Feasibility and Accuracy of Holographic Navigation with Laser Crosshair Simulator Registration on a Mixed-Reality Display
Addressing conventional neurosurgical navigation systems’ high costs and complexity, this study explores the feasibility and accuracy of a simplified, cost-effective mixed reality navigation (MRN) system based on a laser crosshair simulator (LCS). A new automatic registration method was developed, featuring coplanar laser emitters and a recognizable target pattern. The workflow was integrated into Microsoft’s HoloLens-2 for practical application. The study assessed the system’s precision by utilizing life-sized 3D-printed head phantoms based on computed tomography (CT) or magnetic resonance imaging (MRI) data from 19 patients (female/male: 7/12, average age: 54.4 ± 18.5 years) with intracranial lesions. Six to seven CT/MRI-visible scalp markers were used as reference points per case. The LCS-MRN’s accuracy was evaluated through landmark-based and lesion-based analyses, using metrics such as target registration error (TRE) and Dice similarity coefficient (DSC). The system demonstrated immersive capabilities for observing intracranial structures across all cases. Analysis of 124 landmarks showed a TRE of 3.0 ± 0.5 mm, consistent across various surgical positions. The DSC of 0.83 ± 0.12 correlated significantly with lesion volume (Spearman rho = 0.813, p < 0.001). Therefore, the LCS-MRN system is a viable tool for neurosurgical planning, highlighting its low user dependency, cost-efficiency, and accuracy, with prospects for future clinical application enhancements.
- Open Access
- 7 November 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (11) , 1290
A Novel Registration Method for a Mixed Reality Navigation System Based on a Laser Crosshair Simulator: A Technical Note
Mixed Reality Navigation (MRN) is pivotal in augmented reality-assisted intelligent neurosurgical interventions. However, existing MRN registration methods face challenges in concurrently achieving low user dependency, high accuracy, and clinical applicability. This study proposes and evaluates a novel registration method based on a laser crosshair simulator, evaluating its feasibility and accuracy. A novel registration method employing a laser crosshair simulator was introduced, designed to replicate the scanner frame’s position on the patient. The system autonomously calculates the transformation, mapping coordinates from the tracking space to the reference image space. A mathematical model and workflow for registration were designed, and a Universal Windows Platform (UWP) application was developed on HoloLens-2. Finally, a head phantom was used to measure the system’s target registration error (TRE). The proposed method was successfully implemented, obviating the need for user interactions with virtual objects during the registration process. Regarding accuracy, the average deviation was 3.7 ± 1.7 mm. This method shows encouraging results in efficiency and intuitiveness and marks a valuable advancement in low-cost, easy-to-use MRN systems. The potential for enhancing accuracy and adaptability in intervention procedures positions this approach as promising for improving surgical outcomes.
- 7 November 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (11) , 1290
Open AccessA Novel Registration Method for a Mixed Reality Navigation System Based on a Laser Crosshair Simulator: A Technical Note
Mixed Reality Navigation (MRN) is pivotal in augmented reality-assisted intelligent neurosurgical interventions. However, existing MRN registration methods face challenges in concurrently achieving low user dependency, high accuracy, and clinical applicability. This study proposes and evaluates a novel registration method based on a laser crosshair simulator, evaluating its feasibility and accuracy. A novel registration method employing a laser crosshair simulator was introduced, designed to replicate the scanner frame’s position on the patient. The system autonomously calculates the transformation, mapping coordinates from the tracking space to the reference image space. A mathematical model and workflow for registration were designed, and a Universal Windows Platform (UWP) application was developed on HoloLens-2. Finally, a head phantom was used to measure the system’s target registration error (TRE). The proposed method was successfully implemented, obviating the need for user interactions with virtual objects during the registration process. Regarding accuracy, the average deviation was 3.7 ± 1.7 mm. This method shows encouraging results in efficiency and intuitiveness and marks a valuable advancement in low-cost, easy-to-use MRN systems. The potential for enhancing accuracy and adaptability in intervention procedures positions this approach as promising for improving surgical outcomes.