YCYujia Cheng

Yujia Cheng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yujia Cheng has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Guang Yu

    Mechanical and Electrical Engineering Institute, University of Electronic Science and Technology of China Zhongshan Institute, Zhongshan 528400, China

    11 shared publications
  • Guang Yu

    Mechanical and Electrical Engineering Institute, Zhongshan Institute, University of Electronic Science and Technology of China, Zhongshan, Guangdong, 528400, China

    6 shared publications
  • Lijie Peng

    4 shared publications
  • Yan Huang

    School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu 611731, China

    2 shared publications
  • Lixiang He

    School of Materials and Energy, University of Electronic Science & Technology of China, Chengdu 610054, P. R. China

    1 shared publication
  • Liyong Ni

    Mechanical and Electrical Engineering Institute, Zhongshan Institute, University of Electronic Science and Technology of China, Zhongshan, Guangdong, 528400, China

    1 shared publication

Latest Publications

  • Microscopic Morphology and Electrical Properties of Nano-Hexagonal Boron Nitride/ Low-Density Polyethylene used for Agricultural Underground Cable Insulation

    by Guang Yu, Yujia Cheng, Yong Yang, Liyong Ni

    In this study, Nano-hexagonal boron nitride/ low-density polyethylene was prepared from the melting blend. The mass fractions of the nanoparticles in the Low-density polyethylene were 1, 3, and 5 wt%.

  • Open Access

    Power Frequency Breakdown Properties of LDPE-Doped Inorganic Nanoparticles

    by Yujia Cheng, Guang Yu

    Although polyethylene is widely used in electrical insulation, it does not possess dielectric properties. It is therefore desirable to develop insulation materials with excellent dielectric properties. In this study, low-density polyethylene (LDPE) was used as a matrix resin, while MgO, wollastonite, and montmorillonite (MMT) were employed as inorganic nano-additives. Three composites were prepared using the boiling–melt blending approach. Power frequency breakdown tests were performed on the original LDPE and on the prepared nanoparticle/LDPE composites. Upon combination with the Weibull distribution, the breakdown test results revealed that the addition of these nano-additive particles to the LDPE matrix increased the breakdown field strength of the material. The highest breakdown field strength for the nano-MgO/LDPE composite was obtained using a MgO loading of 0.5%. Notably, the obtained value was 1.8% higher than that of the pure LDPE. In addition, the highest breakdown field strength for the nano-wollastonite/LDPE composite was obtained using a wollastonite loading of 1% (7.48% higher than that of pure LDPE). Similarly, the highest breakdown field strength of the nano-MMT/LDPE composite was obtained using an MMT loading of 3%, giving a value that was 6.67% higher than that of the pure LDPE.


  • Open Access

    Parametric Study and Improvement of Anti-Corona Structure in Stator Bar End Based on Finite Element Analysis

    by Yujia Cheng, Guang Yu

    Voltage withstand tests on stator bars can cause destructive phenomena such as thermal breakdown and flashover discharge on the surface of the anti-corona layer. This study optimizes the anti-corona structure at a stator bar’s end to prevent such failures using a 120 MW water-cooled turbogenerator with a rated voltage of 15.75 kV. For a well-designed anti-corona system, the maximum potential gradient of the stator bar should be lower than the discharge intensity of air corona. In our design, the electric field intensity is maintained below 3.1 kV/cm, and the maximum surface loss in the anti-corona layer is limited to less than 0.6 W/cm2. Additionally, the terminal voltage is kept lower than that of flashover voltage at rated conditions. Furthermore, the length of the anti-corona layer should be minimized. The optimization process involves determining the rotation angle of the stator bar, calculating the total length of the anti-corona layer, and analyzing the electric field and loss in the layer at different lengths. The results demonstrate that the optimized anti-corona design effectively reduces the risk of flashover and thermal failure, ensuring stable operation under rated conditions. This manuscript belongs to purely computational experiments. At present, the electrical machinery with 120 MW rated power grade is put into operation steadily. There is a growing requirement for anti-corona. In this manuscript, computing method is used to assist the anti-corona structure design. The electrical machinery insulation is improved by better anti-corona materials. Therefore, the service life of electrical machinery can be prolonged, which is significant in engineering.


  • Open Access

    Power Frequency Breakdown Properties of LDPE-Doped Inorganic Nanoparticles

    by Yujia Yujia, Guang Yu

    Although polyethylene is widely used in electrical insulation, it does not possess dielectric properties. It is therefore desirable to develop insulation materials with excellent dielectric properties. In this study, low density polyethylene (LDPE) was used as a matrix resin, while MgO, wollastonite, and montmorillonite (MMT) were employed as inorganic nano-additives. Three composites were prepared using the boiling–melt blending approach. Power frequency breakdown tests were performed on the original LDPE and on the prepared nanoparticle/LDPE composites. Upon combination with the Weibull distribution, the breakdown test results revealed that the addition of these nano-additive particles to the LDPE matrix decreased the breakdown field strength of the material. The highest breakdown field strength for the nano-MgO/LDPE composite was obtained using a MgO loading of 0.5%. Notably, the obtained value was 1.8% higher than that of the pure LDPE. In addition, the highest breakdown field strength for the nano-wollastonite/LDPE composite was obtained using a wollastonite loading of 1% (7.48% higher than that of pure LDPE). Similarly, the highest breakdown field strength of the nano-MMT/LDPE composite was obtained using an MMT loading of 3%, giving a value that was 6.67% higher than that of the pure LDPE.

  • Open Access

    Electrical Output Simulation Model Establishment about Photovoltaic Microgrid

    by Yujia Cheng, Guang Yu

    With the global energy mix transformation, new energy resources, particularly luminous energy, have garnered increasing attention, along with a gradual increase in their proportion in the electric power sector. However, challenges in new energy resource consumption and system planning persist. Therefore, a reasonable power planning model need to be built, from which the consumptive ability of new energy resource can be improved. The power combination is optimized. The sustainable development of power system can be realized. This study develops a power supply planning model that improves the consumptive ability of new energy resources. Specifically, this study presents a power supply planning model based on a photovoltaic (PV) microgrid system. System modeling and simulation analysis were conducted using MATLAB/Simulink, analyzing the output characteristics of PV microgrid system optimization. Initially, models for PV power and direct current load were established, and the effects of different parameters on the power curve were analyzed. The results demonstrate that the mathematical models are effective in simulating the output characteristics of PV microgrid systems. Additionally, the model optimized the power supply, supporting the sustainable development of the power system. Adjusting the model’s parameters significantly influences the system output, which is valuable for designing and optimizing PV power generation systems.

  • Study of Electrical Tree Growth Properties in Cross-Linked Polyethylene

    by Guang Yu, Lijie Peng, Yujia Cheng

    In this study, the growth mechanism of an electrical tree in cross-linked polyethylene (XLPE) was analyzed from the perspective of aggregated structures.

  • Open Access

    Effect of Adding Nano-Hexagonal Boron Nitride-Zinc Oxide on the Aggregated Structure and Properties of Cross-Linked Polyethylene Composites

    by Guang Yu, Lijie Peng, Yujia Cheng

    After the surface modification, the nano-HBN-ZnO/XLPE samples can be prepared by melting blend.


  • Open Access

    Corrosion-Resistance Properties of Submarine Cable Steel Armor

    by Guang Yu, Lijie Peng, Yujia Cheng

    The corrosion resistance of steel was poor. At the beginning of the corrosion process, the surface zinc in the hot-dip galvanized steel wire generated an oxidation film, which slowed the corrosion rate, improving the corrosion resistance.


  • Electrical Output Simulation Model for a Photovoltaic Microgrid

    by Guang Yu, Lijie Peng, Yujia Cheng

    This study sought to enhance the consumptive capability of renewable energy, particularly photovoltaic (PV) systems, through a novel power supply planning model that effectively integrates and optimizes PV microgrid systems to support sustainable energy objectives.

  • Open Access

    Hydro Generator Stator Bar Modeling and Simulation Based on Finite Element Simulation

    by Guang Yu, Yujia Cheng

    As motor capacity and rated voltage increase, the demand for motor insulation also increases. Additionally, the electric field distribution at the end of a large-scale hydro generator is extremely nonuniform, and corona discharge occurs. This destroys the main insulation, which significantly affects the service life of electrical machinery. The regulation of the electric field concentration at the end of a large-scale hydro generator needs to be addressed. In this manuscript, a large hydro generator with 120 MW rated capacity and 15.75 kV rated voltage was studied. For the purpose of electric field homogenization in the stator bar end, decrease of highest field strength, and surface loss, the computing methods of the electric field in the stator bar end were studied. The electric field distribution in the stator bar end was obtained. According to COMSOL 5.6 modeling software, the hydro generator stator bar is an accurate model. Using finite element analysis (FEA), the stator bar characteristics can be simulated. The different stator bars with no anti-corona structure, linear anti-corona structure, two-layer nonlinear anti-corona structure, and three-layer nonlinear anti-corona structure were compared, including the electric potential, electric field, and loss distribution under rated voltage. From the experimental results, with no anti-corona structure and linear anti-corona structure, the electric field concentration is present in the exit slot. The values of electric field and loss are both higher, which causes corona discharge easily. With the nonlinear anti-corona structure, the electric field concentration is improved significantly, effectively decreasing the highest electric field. The three-layer nonlinear anti-corona structure is the best. Compared with the two-layer nonlinear anti-corona structure, the values of the highest electric field and loss are 16% and 77% lower, respectively.