DWDezhao Wang

Dezhao Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dezhao Wang has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Research on the DF-TSOM method for detecting subsurface defects of optical components

    by Na Wang, Weihu Zhou, Xiaojiao Song, Dezhao Wang, Lituo Liu

    In response to the growing need for detecting subsurface defects at the hundred-nanometer scale, this study introduces what we believe to be a novel dark field through-focus scanning optical microscopy (DF-TSOM) technique. Subsurface defect samples were prepared with a depth of 100 µm and diameters of 1 µm, 0.4 µm, 0.2 µm, and 0.1 µm for experiments. Results demonstrate that DF-TSOM successfully detects subsurface defects with diameters 0.1 µm, a feat unattainable with traditional TSOM, which failed to accurately detect subsurface defects with diameters 0.4 µm. DF-TSOM improves the contrast by approximately 10 times compared to traditional TSOM when the subsurface defect diameter is 1 µm. This study presents a promising new approach for the detection of subsurface defects in transparent materials, offering advantages such as high sensitivity, enhanced contrast, a simplified hardware setup, and the potential for online detection.


  • High-resolution microscopic fringe projection profilometry using Nyquist frequency fringe

    by Dezhao Wang, Weihu Zhou, Zili Zhang, Yanhui Kang, Xiaoyan Sheng, Fanchang Meng, Na Wang


  • Focal plane coincidence method for a multi-view telecentric 3D imaging system

    by Dezhao Wang, Weihu Zhou, Zili Zhang, Fanchang Meng, Chao Gao

    Multi-view microscopic fringe projection systems, which use high-resolution telecentric lenses and the Scheimpflug condition, face challenges in coinciding focal planes accurately, resulting in inconsistent measurements between views. In this Letter, we developed a sharpness evaluation function based on the total power of the line-spread function, which was subsequently used to generate a full-field sharpness distribution map. Then we employed the correlation between the sharpness map and orientation of the focal plane to precisely coincide the focal planes. Experimental results validate the proposed method and demonstrate its improved consistency in 3D reconstruction.


  • Research on TSOM detection method for subsurface defects of optical components

    by na Wang, Lituo Liu, Genzi Li, Xiaojiao Song, Dezhao Wang, Guannan Li, Weihu Zhou

    Subsurface defects of optical components will reduce the coating quality, transmission characteristics, damage threshold and other characteristics of optical components, and seriously affect the service life of optical components. In order to quickly and non-destructively detect subsurface defects of optical components, this paper proposes a method for utilizing Through-Focus Scanning Optical Microscopy (TSOM) to detect subsurface defects of optical components. Based on the traditional scanning method of optical microscopy, a set of two-dimensional optical images is collected by scanning through the various focus positions (from above the focus to below the focus, within the focus and out of focus). These acquired images are stacked and arranged in the Z direction to generate TSOM images, and the target is located by obtaining the maximum grayscale value of the detected feature. This method can detect subsurface defects of optical glass with a size of 2μm and locate the depth of defects. Through experimental testing of package samples, it was found that defects of the same depth exhibit consistent grayscale variations. This characteristic enables the differentiation between defects located on the surface or subsurface of the 30nm thick structure.

  • Anti-crosstalk absolute phase retrieval method for microscopic fringe projection profilometry using temporal frequency-division multiplexing

    by Dezhao Wang, Weihu Zhou, Zili Zhang, Yanhui Kang, Fanchang Meng, Na Wang

    In microscopic fringe projection profilometry (MFPP), the traditional absolute phase retrieval method using composite frequency fringe has the shortcomings of low accuracy and poor robustness due to mutual crosstalk of harmonic from the different channels of frequency-division multiplexing. In this study, an absolute phase retrieval method that avoids the inter-channel crosstalk is proposed. By introducing guard bands to accommodate the frequency channels corresponding to the second harmonic that dominate the high order harmonics, the aliasing between the second harmonic and the fundamental is eliminated. Consequently, phase maps without crosstalk can be demodulated using appropriate phase-shifting algorithms. The proposed method is well-suited for high-precision three-dimensional shape measurement scenarios in many fields such as integrated circuit manufacturing process control and micro-electro-mechanical system quality inspection. The experiment results demonstrate that the anti-crosstalk method is effective and can realize three-dimensional reconstruction for discontinuous planar surface and spherical surface.


  • High efficiency CdTe solar cells with a through-thickness polycrystalline CdTe thin film

    by Kai Shen, Zhizhong Bai, Yi Deng, Ruilong Yang, Dezhao Wang, Qiang Li, Deliang Wang

    The absorber layer in a CdTe solar cell is made of a polycrystalline CdTe thin film with a thickness of several μm. It is highly desirable that the CdTe film could be made of through-thickness CdTe grains. In such a case, the photon-generated carriers could be transported to the positive and negative contacts without encountering any grain boundaries in CdTe, thus significantly reducing the carrier scattering/recombination occurring at the grain boundary. We propose and demonstrate that one of the most important roles for the presence of oxygen during the CdTe film growth is to in situ form a low-melting liquid mixture of oxides (CdTeOx, TeOx and CdOx), Te, and CdTe on the growth front of the CdTe grain surface. This liquid mixture, having a thickness of ∼50 nm, assists material transport from the vapor through the liquid to the liquid–solid interface, where Cd, Te, and Cd–Te molecules reacted to epitaxially deposit on the CdTe growth front. Assisted by a highly crystalline mono-grained CdS window layer template, CdTe preferential growth with through-thickness grains along the normal direction of the film has been achieved. CdTe solar cells fabricated with such CdTe absorbers demonstrate much enhanced external quantum efficiency, and cells with efficiencies as high as 14–15.2% have been fabricated.


  • [Carotid plaque characteristics detected with 3.0T high resolution nuclear magnetic resonance imaging in patients with coronary artery disease].

    by Changpeng Song, Dezhao Wang, Hongyu Hu, Qiang Fu, Wei Chen, Qian Wang, Caixia Guo, Junping Tian, Li Ma, Xiaowei Xu, et al.

    To assess the value of detecting the compositional features of carotid atherosclerotic plaques by 3.0T high resolution magnetic resonance imaging (MRI) in patients with coronary artery disease (CAD). Consecutive 104 patients with coronary atherosclerosis confirmed by coronary angiography were prospectively recruited from January 2013 to January 2015 in Tiantan hospital. All patients were imaged with 3.0T high resolution MRI system. After exclusion patients with poor image quality, 97 patients were divided into 3 groups according to the degree of coronary artery stenosis: coronary atherosclerosis group (coronary stenosis between 1%-49%, n=16); single-vessel lesion group (single vessel lesion with stenosis between 50%-100%, n=48); multi-vessel lesion group (two or three vessel lesions with stenosis between 50%-100% or left main stem disease, n=33). The prevalence of total carotid plaque, calcified plaque, lipid-rich necrotic core, intra-plaque hemorrhage, plaque ulcer and rupture were compared among 3 groups. The prevalence of total carotid plaque (81.3%(13/16), 72.9%(35/48), and 93.9%(31/33)) and calcified plaque (50.0%(8/16), 35.4%(17/48), and 42.4%(14/33)) were similar among the 3 groups (both P>0.05). The prevalence of carotid lipid-rich necrotic core in coronary atherosclerosis group was significantly lower than in single-vessel lesion group (18.8%(3/16) vs. 64.6%(31/48), P0.05). Intra-plaque hemorrhage was detected in 2 patients of multi-vessel lesion group. There was no plaque ulcer or rupture in this cohort. Carotid plaque features are associated with the severity of coronary atherosclerosis in CAD patients.