Wenchang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wenchang Wang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Guodong Li
School of Electrical and Information Engineering, Anhui University of Science and Technology, Huainan 232001, People’s Republic of China
4 shared publications- Jingbao Wang
School of Electrical and Information Engineering, Anhui University of Science and Technology, Huainan, China
4 shared publications Pengcheng Yan
State Key Laboratory of Mining Response and Disaster Prevention and Control in Deep Coal Mine, Anhui University of Science and Technology, Huainan 232001, People’s Republic of China
4 shared publicationsZiming Wen
School of Electrical and Information Engineering, Anhui University of Science and Technology, Huainan 232001, People’s Republic of China
4 shared publications- Guodong Li
School of Electrical and Information Engineering, Anhui University of Science and Technology, Huainan, China
2 shared publications Jingbao Wang
2 shared publications
Latest Publications
- 2 August 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (11) , 115202
Transformer fault diagnosis based on DBO-BiLSTM algorithm and LIF technology
In response to the deficiencies of traditional power transformer fault detection techniques, such as low sensitivity and the inability for online monitoring, a novel transformer fault diagnosis model combining laser-induced fluorescence (LIF) technology with deep learning is proposed. Initially, the spectral data of transformer insulation oil is acquired using LIF technology, yielding spectral data for various fault types. Subsequently, MinMaxScaler and standard normalized variate methods are employed for denoising and preprocessing the spectral data. The preprocessed data is then subjected to dimensionality reduction using linear discriminant analysis and T-distributed stochastic neighbor embedding to ensure that the spectral data retains maximal feature information while minimizing its dimensionality. Following this, long short-term memory, bidirectional long short-term memory (BiLSTM), dung beetle optimizer-BiLSTM, convolutional neural network, and support vector machine models are constructed. The reduced-dimensional data is fed into each of the five models for training to facilitate transformer fault diagnosis. Through comparative analysis among the five models, the optimal model is selected. Experimental results indicate that the dung beetle optimization-BiLSTM model is the most suitable for transformer fault diagnosis in this experiment, underscoring its significant implications for ensuring the safety of power systems.
- 2 August 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (11) , 115202
Transformer fault diagnosis based on DBO-BiLSTM algorithm and LIF technology
In response to the deficiencies of traditional power transformer fault detection techniques, such as low sensitivity and the inability for online monitoring, a novel transformer fault diagnosis model combining laser-induced fluorescence (LIF) technology with deep learning is proposed. Initially, the spectral data of transformer insulation oil is acquired using LIF technology, yielding spectral data for various fault types. Subsequently, MinMaxScaler and standard normalized variate methods are employed for denoising and preprocessing the spectral data. The preprocessed data is then subjected to dimensionality reduction using linear discriminant analysis and T-distributed stochastic neighbor embedding to ensure that the spectral data retains maximal feature information while minimizing its dimensionality. Following this, long short-term memory, bidirectional long short-term memory (BiLSTM), dung beetle optimizer-BiLSTM, convolutional neural network, and support vector machine models are constructed. The reduced-dimensional data is fed into each of the five models for training to facilitate transformer fault diagnosis. Through comparative analysis among the five models, the optimal model is selected. Experimental results indicate that the dung beetle optimization-BiLSTM model is the most suitable for transformer fault diagnosis in this experiment, underscoring its significant implications for ensuring the safety of power systems.
- 12 June 2024
- Published by Springer Nature in Journal of Real-Time Image Processing
- Vol. 21 (4) , 1-16
YOLOv8n-LSLW: a lightweight method for real-time detection of wild fishing behavior
- 12 June 2024
- Published by Springer Nature in Journal of Real-Time Image Processing
- Vol. 21 (4) , 1-16
YOLOv8n-LSLW: a lightweight method for real-time detection of wild fishing behavior
- 10 February 2024
- Published by Elsevier in Microchemical Journal
- Vol. 199
A lightweight coal gangue detection method based on multispectral imaging and enhanced YOLOv8n
- 10 February 2024
- Published by Elsevier in Microchemical Journal
- Vol. 199
A lightweight coal gangue detection method based on multispectral imaging and enhanced YOLOv8n
- 7 January 2024
- Published by Taylor & Francis in International Journal of Coal Preparation and Utilization
- Vol. 44 (11) , 1843-1863
Detection of coal gangue based on spectral technology and enhanced lightweight YOLOv7-tiny
- 7 January 2024
- Published by Taylor & Francis in International Journal of Coal Preparation and Utilization
- Vol. 44 (11) , 1843-1863
Detection of coal gangue based on spectral technology and enhanced lightweight YOLOv7-tiny
- 21 December 2023
- Published by Elsevier in Engineering Failure Analysis
- Vol. 157, 107894
Three-dimensional mechanical characteristics analysis of bolted joints and loosening mechanism
- 21 December 2023
- Published by Elsevier in Engineering Failure Analysis
- Vol. 157, 107894
Three-dimensional mechanical characteristics analysis of bolted joints and loosening mechanism
- 28 November 2023
- Published by Springer Nature in Journal of Mountain Science
- Vol. 20 (11) , 3392-3401
Water source identification in mines combining LIF technology and ResNet
- 28 November 2023
- Published by Springer Nature in Journal of Mountain Science
- Vol. 20 (11) , 3392-3401
Water source identification in mines combining LIF technology and ResNet
- Open Access
- 15 November 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (2) , 025504
Transformer fault diagnosis based on MPA-RF algorithm and LIF technology
Power transformers are essential components in power systems used to regulate voltage, transmit electrical energy, provide isolation, and match loads. They contribute to efficient and reliable electricity transmission and distribution. However, traditional methods for diagnosing transformer faults are time-consuming, not suitable for online monitoring, and greatly affected by environmental conditions. In this experiment, we propose the use of laser-induced fluorescence (LIF) technology for transformer fault detection. LIF technology is a method for analyzing and detecting specific molecules or atoms in samples. It combines laser technology with fluorescence measurements, making it a powerful analytical tool. It achieves high sensitivity and selectivity in analyzing molecules and atoms by exciting and detecting fluorescence in the sample. This makes it an important technology in scientific research and practical applications. Furthermore, LIF technology has not been previously applied to power transformer fault diagnosis. Therefore, this experiment introduces a transformer fault diagnosis model based on the marine predators algorithm (MPA) optimized random forest (RF) algorithm and LIF spectroscopy technology. Four different oil samples were selected for experimentation: crude oil, thermally faulty oil, partially moist oil, and electrically faulty oil. First, LIF technology for collect spectral images and data from the different fault oil samples. The obtained spectral data was preprocessed using two methods, multivariate scatter correction (MSC) and standardization method (SNV). Then, principal component analysis (PCA) and kernel principal component analysis (KPCA) for reducing the dimensionality of the preprocessed spectral data. Finally, the RF model, MPA-RF model, and PSO-RF model were established; and the reduced data was input into the model for training. Through comparisons of the predictions on the test set, evaluation metrics of the algorithm (including fitting coefficient, MSE, RMSE, and RMSE), and iteration convergence curves, the best transformer fault diagnosis model was identified. The results show that the MSC-KPCA-MPA-RF model has the best matching resule, with a fitting coefficient of 0.9963 and a mean square error of 0.0047. The SNV-PCA-MPA-RF model has the worst fitting effect, with a fitting coefficient of 0.9840 and a mean square error of 0.0199. Through comparisons of the convergence of different models, the MSC-KPCA-MPA-RF model has the best convergence and is the most applicable model for transformer fault diagnosis in this experiment. This model has significant implications for ensuring the safety of the power system.
- 15 November 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (2) , 025504
Open AccessTransformer fault diagnosis based on MPA-RF algorithm and LIF technology
Power transformers are essential components in power systems used to regulate voltage, transmit electrical energy, provide isolation, and match loads. They contribute to efficient and reliable electricity transmission and distribution. However, traditional methods for diagnosing transformer faults are time-consuming, not suitable for online monitoring, and greatly affected by environmental conditions. In this experiment, we propose the use of laser-induced fluorescence (LIF) technology for transformer fault detection. LIF technology is a method for analyzing and detecting specific molecules or atoms in samples. It combines laser technology with fluorescence measurements, making it a powerful analytical tool. It achieves high sensitivity and selectivity in analyzing molecules and atoms by exciting and detecting fluorescence in the sample. This makes it an important technology in scientific research and practical applications. Furthermore, LIF technology has not been previously applied to power transformer fault diagnosis. Therefore, this experiment introduces a transformer fault diagnosis model based on the marine predators algorithm (MPA) optimized random forest (RF) algorithm and LIF spectroscopy technology. Four different oil samples were selected for experimentation: crude oil, thermally faulty oil, partially moist oil, and electrically faulty oil. First, LIF technology for collect spectral images and data from the different fault oil samples. The obtained spectral data was preprocessed using two methods, multivariate scatter correction (MSC) and standardization method (SNV). Then, principal component analysis (PCA) and kernel principal component analysis (KPCA) for reducing the dimensionality of the preprocessed spectral data. Finally, the RF model, MPA-RF model, and PSO-RF model were established; and the reduced data was input into the model for training. Through comparisons of the predictions on the test set, evaluation metrics of the algorithm (including fitting coefficient, MSE, RMSE, and RMSE), and iteration convergence curves, the best transformer fault diagnosis model was identified. The results show that the MSC-KPCA-MPA-RF model has the best matching resule, with a fitting coefficient of 0.9963 and a mean square error of 0.0047. The SNV-PCA-MPA-RF model has the worst fitting effect, with a fitting coefficient of 0.9840 and a mean square error of 0.0199. Through comparisons of the convergence of different models, the MSC-KPCA-MPA-RF model has the best convergence and is the most applicable model for transformer fault diagnosis in this experiment. This model has significant implications for ensuring the safety of the power system.
- Open Access
- 14 August 2023
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 26, 3118-3135
Design and experimental investigation of the high-entropy alloys AlCrFeNiCu and AlCrFeNbMo
- 14 August 2023
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 26, 3118-3135
Open AccessDesign and experimental investigation of the high-entropy alloys AlCrFeNiCu and AlCrFeNbMo