Zeliang Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zeliang Gao has a total of 190 co-authors. Here are the top co-authors by number of shared publications:
- Xutang Tao
Shandong University
38 shared publications Youxuan Sun
26 shared publicationsFeifei Guo
State Key Laboratory of Crystal Materials, Institute of Crystal Materials
24 shared publicationsFuai Hu
20 shared publications- Xiangxin Tian
School of Materials and Engineering, Linyi University, Linyi 276000, China
16 shared publications Qian Wu
State Key Laboratory of Crystal Materials, Shandong University, Jinan, China
15 shared publications
Latest Publications
- 29 October 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 14 (41) , 20075-20083
Cr 3+ -doped GSGG garnet crystals as high-performance near-infrared scintillators for X-ray imaging
Cr 3+ -doped GSGG garnet crystal was grown by Czochralski method. It shows bright near-infrared scintillation with 22 850 ph MeV −1 light yield and 16 lp mm −1 resolution, demonstrating great potential for Si-detector-coupled X-ray imaging.
- 29 October 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 14 (41) , 20075-20083
Cr 3+ -doped GSGG garnet crystals as high-performance near-infrared scintillators for X-ray imaging
Cr 3+ -doped GSGG garnet crystal was grown by Czochralski method. It shows bright near-infrared scintillation with 22 850 ph MeV −1 light yield and 16 lp mm −1 resolution, demonstrating great potential for Si-detector-coupled X-ray imaging.
- Open Access
- 23 October 2026
- Published by OAE Publishing Inc. in Microstructures
- Vol. 6 (6)
High-performance self-powered X-ray detection materials based on KTiOAsO4 polar crystals
Self-powered X-ray detectors can perform X-ray inspections without requiring an external power supply, enabling the design of highly portable X-ray detection devices. As a result, they hold broad application prospects in the fields of industrial non-destructive testing and medical examinations. This paper reports a self-powered X-ray detector based on a KTiOAsO4 polar crystal, which possesses a strong built-in electric field (approximately 40 V·mm-1) capable of separating photo-generated carriers. The detector operates efficiently without requiring an external bias, thereby reducing power consumption and simplifying the device structure. Under zero-bias conditions, the detector achieves a sensitivity of up to 110.72 μC·Gyair-1·cm-2 along the Y-axis, with a detection limit as low as 0.061 μGyair·s-1 along the X-axis, demonstrating excellent low-dose imaging. When the applied bias voltage was increased to 200 V, the sensitivity in the Y-axis direction reached a maximum of 192.96 μC·Gyair-1cm-2 (70 keV), indicating excellent radiation detection performance. Furthermore, its high ion activation energy (> 200 meV along the Y direction of the principal axis) suppresses ion migration, effectively preventing performance degradation and ensuring long-term stability. The anisotropic carrier-transport characteristics allow selection of the optimal crystal orientation based on specific application requirements. This study demonstrates that this well-established nonlinear optical crystal can serve as an X-ray detection material for medical imaging and trace radiation detection, providing an experimental foundation for its use as a low-power, high-performance radiation detection platform.
- 23 October 2026
- Published by OAE Publishing Inc. in Microstructures
- Vol. 6 (6)
Open AccessHigh-performance self-powered X-ray detection materials based on KTiOAsO4 polar crystals
Self-powered X-ray detectors can perform X-ray inspections without requiring an external power supply, enabling the design of highly portable X-ray detection devices. As a result, they hold broad application prospects in the fields of industrial non-destructive testing and medical examinations. This paper reports a self-powered X-ray detector based on a KTiOAsO4 polar crystal, which possesses a strong built-in electric field (approximately 40 V·mm-1) capable of separating photo-generated carriers. The detector operates efficiently without requiring an external bias, thereby reducing power consumption and simplifying the device structure. Under zero-bias conditions, the detector achieves a sensitivity of up to 110.72 μC·Gyair-1·cm-2 along the Y-axis, with a detection limit as low as 0.061 μGyair·s-1 along the X-axis, demonstrating excellent low-dose imaging. When the applied bias voltage was increased to 200 V, the sensitivity in the Y-axis direction reached a maximum of 192.96 μC·Gyair-1cm-2 (70 keV), indicating excellent radiation detection performance. Furthermore, its high ion activation energy (> 200 meV along the Y direction of the principal axis) suppresses ion migration, effectively preventing performance degradation and ensuring long-term stability. The anisotropic carrier-transport characteristics allow selection of the optimal crystal orientation based on specific application requirements. This study demonstrates that this well-established nonlinear optical crystal can serve as an X-ray detection material for medical imaging and trace radiation detection, providing an experimental foundation for its use as a low-power, high-performance radiation detection platform.
- Open Access
- 21 September 2026
- Published by Wiley in Advanced Functional Materials
- p. e78571
“Complementary Material Integration”: Co‐Optimizing Low Noise and High Signal in X‐Ray Detectors for High Detectivity via β ‐Ga 2 O 3 /3D/2D Metal Halide Perovskite Heterojunction
Achieving high‐contrast imaging under low‐dose x‐rays is a core challenge for x‐ray detectors, as co‐optimizing low dark current and high sensitivity in a single material remains difficult. Herein, we propose a complementary material integration (CMI) strategy by combining a high resistivity wide bandgap oxide with a high µτ product perovskite. This strategy is demonstrated in the x‐ray detector based on a β ‐Ga 2 O 3 /3D/2D metal halide perovskite (MHP) heterostructure. The high resistivity of β ‐Ga 2 O 3 ensures low noise, while its combination with a 2D MHP layer effectively passivates the 3D MHP active layer, yielding both high performance and enhanced stability. The detector exhibits a large µτ product of 1.61 × 10 −3 cm 2 V −1 , a dark current of only 1.09 pA at 100 V, and a high sensitivity of 7140 µC Gy air −1 cm −2 . These properties yield a high quasi‐detectivity () of 354.86 C Gy −1 cm −1 A −1/2 and a low detection limit of 8.16 nGy s −1 . Furthermore, the detector realizes high‐contrast imaging (SNR = 138.0) for x‐rays at the medically safe dose (2.944 µGy s −1 ). This study successfully realizes the co‐optimization of low dark current, high sensitivity, and low detection limit, and provides a CMI strategy for high‐performance x‐ray imaging devices.
- 21 September 2026
- Published by Wiley in Advanced Functional Materials
- p. e78571
Open Access“Complementary Material Integration”: Co‐Optimizing Low Noise and High Signal in X‐Ray Detectors for High Detectivity via β ‐Ga 2 O 3 /3D/2D Metal Halide Perovskite Heterojunction
Achieving high‐contrast imaging under low‐dose x‐rays is a core challenge for x‐ray detectors, as co‐optimizing low dark current and high sensitivity in a single material remains difficult. Herein, we propose a complementary material integration (CMI) strategy by combining a high resistivity wide bandgap oxide with a high µτ product perovskite. This strategy is demonstrated in the x‐ray detector based on a β ‐Ga 2 O 3 /3D/2D metal halide perovskite (MHP) heterostructure. The high resistivity of β ‐Ga 2 O 3 ensures low noise, while its combination with a 2D MHP layer effectively passivates the 3D MHP active layer, yielding both high performance and enhanced stability. The detector exhibits a large µτ product of 1.61 × 10 −3 cm 2 V −1 , a dark current of only 1.09 pA at 100 V, and a high sensitivity of 7140 µC Gy air −1 cm −2 . These properties yield a high quasi‐detectivity () of 354.86 C Gy −1 cm −1 A −1/2 and a low detection limit of 8.16 nGy s −1 . Furthermore, the detector realizes high‐contrast imaging (SNR = 138.0) for x‐rays at the medically safe dose (2.944 µGy s −1 ). This study successfully realizes the co‐optimization of low dark current, high sensitivity, and low detection limit, and provides a CMI strategy for high‐performance x‐ray imaging devices.
- 15 September 2026
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (86)
Lead‐Free Relaxor Ferroelectric Ceramic for High Temperature Self‐Powered X‐Ray Imaging via Phase Boundary Engineering
Self‐powered x‐ray detectors are renowned for compact size, portable design, and energy efficiency, offering significant potential for applications in security checks and industrial testing under extreme conditions. The challenge of designing self‐powered x‐ray detectors operating across a wide temperature range remains a critical hurdle in actual applications. Herein, the x‐ray detection capabilities of a highly polar 0.7BiFeO 3 ‐0.3BaTiO 3 ‐0.005Mn (0.7BF‐0.3BT‐0.005Mn) relaxor ferroelectric ceramic wafer with low‐polarization anisotropic configuration are reported for the first time. This 0.7BF‐0.3BT‐0.005Mn detector achieved a giant sensitivity of 1120 µC Gy air −1 cm −2 (under 70 keV) and a low detection limit of 9 nGy s −1 . It also achieved an ultrahigh self‐powered sensitivity of 688 µC Gy air −1 cm −2 , marking the first reported record‐breaking x‐ray detection performance in a lead‐free ferroelectric ceramic system. Remarkable x‐ray detection performance originates from the high atomic number composition design and the unique low‐anisotropy polarization structure of morphology‐phase boundary (MPB). More importantly, under zero‐bias conditions, the material achieved distortion‐free x‐ray imaging at 150°C, validating its practical application value. This study systematically reveals the intrinsic relationship between local lattice distortion, polarization configuration, and x‐ray detection performance, and provides a clear design concept and structural blueprint for next‐generation radiation detectors with high‐temperature self‐powered.
- 15 September 2026
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (86)
Lead‐Free Relaxor Ferroelectric Ceramic for High Temperature Self‐Powered X‐Ray Imaging via Phase Boundary Engineering
Self‐powered x‐ray detectors are renowned for compact size, portable design, and energy efficiency, offering significant potential for applications in security checks and industrial testing under extreme conditions. The challenge of designing self‐powered x‐ray detectors operating across a wide temperature range remains a critical hurdle in actual applications. Herein, the x‐ray detection capabilities of a highly polar 0.7BiFeO 3 ‐0.3BaTiO 3 ‐0.005Mn (0.7BF‐0.3BT‐0.005Mn) relaxor ferroelectric ceramic wafer with low‐polarization anisotropic configuration are reported for the first time. This 0.7BF‐0.3BT‐0.005Mn detector achieved a giant sensitivity of 1120 µC Gy air −1 cm −2 (under 70 keV) and a low detection limit of 9 nGy s −1 . It also achieved an ultrahigh self‐powered sensitivity of 688 µC Gy air −1 cm −2 , marking the first reported record‐breaking x‐ray detection performance in a lead‐free ferroelectric ceramic system. Remarkable x‐ray detection performance originates from the high atomic number composition design and the unique low‐anisotropy polarization structure of morphology‐phase boundary (MPB). More importantly, under zero‐bias conditions, the material achieved distortion‐free x‐ray imaging at 150°C, validating its practical application value. This study systematically reveals the intrinsic relationship between local lattice distortion, polarization configuration, and x‐ray detection performance, and provides a clear design concept and structural blueprint for next‐generation radiation detectors with high‐temperature self‐powered.
- 15 July 2026
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (64)
Topological Semimetal Enhancement Enables Ultra‐Sensitive Flat‐Panel X‐Ray Imaging in Hydrogen‐Bonded MAPbI 3 /(TaSe 4 ) 2 I Wafers
Although three‐dimensional metal halide perovskites are promising for highly sensitive X‐ray detection, ion migration severely compromises their stability and sensitivity. Conventional heterojunction designs often suppress ion migration at the cost of impeding carrier transport. Here, we report a novel strategy to construct a hydrogen bond‐mediated heterojunction between MAPbI 3 perovskite and the topological Weyl semimetal (TaSe 4 ) 2 I. Interfacial N─H⋯I hydrogen bonds effectively anchor mobile ions, significantly suppressing ion migration, while the topological surface states of (TaSe 4 ) 2 I enable ultrahigh carrier mobility. The gradient pressing method enables scalable fabrication of large‐area, high‐quality heterojunction wafers. This heterojunction exhibits a remarkable 136% increase in ion migration activation energy (0.604 eV) and an ultra‐low dark current drift (1.83 × 10 −4 nA cm −1 s −1 V −1 ). Critically, the topology‐enhanced photoconductive gain mechanism yields an outstanding steady‐state sensitivity of (1.03 ± 0.21)× 10 6 µC Gy −1 cm −2 and a low detection limit of 76.5 nGy s −1 . Finally, the resulting X‐ray imager based on a TFT backplane achieves a spatial resolution of 2.1 lp mm −1 (0.42 lp/pixel). Our work provides an effective strategy for the further development of novel scalable and ultra‐sensitive flat‐panel X‐ray detectors.
- 15 July 2026
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (64)
Topological Semimetal Enhancement Enables Ultra‐Sensitive Flat‐Panel X‐Ray Imaging in Hydrogen‐Bonded MAPbI 3 /(TaSe 4 ) 2 I Wafers
Although three‐dimensional metal halide perovskites are promising for highly sensitive X‐ray detection, ion migration severely compromises their stability and sensitivity. Conventional heterojunction designs often suppress ion migration at the cost of impeding carrier transport. Here, we report a novel strategy to construct a hydrogen bond‐mediated heterojunction between MAPbI 3 perovskite and the topological Weyl semimetal (TaSe 4 ) 2 I. Interfacial N─H⋯I hydrogen bonds effectively anchor mobile ions, significantly suppressing ion migration, while the topological surface states of (TaSe 4 ) 2 I enable ultrahigh carrier mobility. The gradient pressing method enables scalable fabrication of large‐area, high‐quality heterojunction wafers. This heterojunction exhibits a remarkable 136% increase in ion migration activation energy (0.604 eV) and an ultra‐low dark current drift (1.83 × 10 −4 nA cm −1 s −1 V −1 ). Critically, the topology‐enhanced photoconductive gain mechanism yields an outstanding steady‐state sensitivity of (1.03 ± 0.21)× 10 6 µC Gy −1 cm −2 and a low detection limit of 76.5 nGy s −1 . Finally, the resulting X‐ray imager based on a TFT backplane achieves a spatial resolution of 2.1 lp mm −1 (0.42 lp/pixel). Our work provides an effective strategy for the further development of novel scalable and ultra‐sensitive flat‐panel X‐ray detectors.
- 4 July 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 18 (28) , 39062-39069
Improved Carrier Transport and Enhanced Detection Sensitivity Through Zr 4+ Doping in LiYMo 2 O 8 Single Crystals for X-ray Detectors
X-ray detectors play an important role in medical imaging, security inspection, industrial nondestructive testing, and high-energy physics. Oxide single crystals are attractive candidates for direct X-ray detection because of their high chemical stability, good mechanical robustness, and feasibility for large-size crystal growth. However, their ultrahigh intrinsic resistivity often limits photocurrent generation and thus restricts detection sensitivity. Here, Zr doping is proposed as a strategy to regulate carrier transport in LiYMo2O8 (LYMO) single crystals. Pristine LYMO and Zr-doped LYMO crystals were successfully grown by the top-seeded solution growth method. The pristine LYMO crystal exhibits resistivities of 9.96 × 1013 and 1.44 × 1014 Ω cm along the a- and c-axes, respectively, with corresponding mobility-lifetime (μτ) products of 1.15 × 10-3 and 1.81 × 10-3 cm2 V-1. After Zr incorporation, the a-axis resistivity decreases to 5.68 × 109 Ω cm, while the μτ product increases to 8.97 × 10-3 cm2 V-1. As a result, the a-axis X-ray sensitivity reaches 431 μC Gy-1 cm-2 under 40 keV X-ray irradiation, more than twice that of the pristine LYMO detector. The Zr-doped LYMO detector also maintains low detection limits of 50.1 and 29.8 nGy s-1 along the a- and c-axes, respectively. These results demonstrate that rational Zr4+ donor doping is an effective approach to balancing resistivity, charge collection efficiency, and baseline stability in high-resistivity oxide crystals for improved X-ray detection.
- 4 July 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 18 (28) , 39062-39069
Improved Carrier Transport and Enhanced Detection Sensitivity Through Zr 4+ Doping in LiYMo 2 O 8 Single Crystals for X-ray Detectors
X-ray detectors play an important role in medical imaging, security inspection, industrial nondestructive testing, and high-energy physics. Oxide single crystals are attractive candidates for direct X-ray detection because of their high chemical stability, good mechanical robustness, and feasibility for large-size crystal growth. However, their ultrahigh intrinsic resistivity often limits photocurrent generation and thus restricts detection sensitivity. Here, Zr doping is proposed as a strategy to regulate carrier transport in LiYMo2O8 (LYMO) single crystals. Pristine LYMO and Zr-doped LYMO crystals were successfully grown by the top-seeded solution growth method. The pristine LYMO crystal exhibits resistivities of 9.96 × 1013 and 1.44 × 1014 Ω cm along the a- and c-axes, respectively, with corresponding mobility-lifetime (μτ) products of 1.15 × 10-3 and 1.81 × 10-3 cm2 V-1. After Zr incorporation, the a-axis resistivity decreases to 5.68 × 109 Ω cm, while the μτ product increases to 8.97 × 10-3 cm2 V-1. As a result, the a-axis X-ray sensitivity reaches 431 μC Gy-1 cm-2 under 40 keV X-ray irradiation, more than twice that of the pristine LYMO detector. The Zr-doped LYMO detector also maintains low detection limits of 50.1 and 29.8 nGy s-1 along the a- and c-axes, respectively. These results demonstrate that rational Zr4+ donor doping is an effective approach to balancing resistivity, charge collection efficiency, and baseline stability in high-resistivity oxide crystals for improved X-ray detection.
- 16 June 2026
- Published by Royal Society of Chemistry (RSC) in Materials Horizons
- Vol. 13 (16) , 8130-8140
Covalent self-assembled monolayer passivation enables ultrahigh-sensitivity and ultrastable MAPbI 3 single-crystal X-ray detectors via interfacial dipole engineering
Covalent PFTS monolayer on MAPbI 3 single crystals forms Si–O–Pb bonds and an oriented dipole, simultaneously passivating surface defects and suppressing dark current for high-sensitivity X-ray detection.
- 16 June 2026
- Published by Royal Society of Chemistry (RSC) in Materials Horizons
- Vol. 13 (16) , 8130-8140
Covalent self-assembled monolayer passivation enables ultrahigh-sensitivity and ultrastable MAPbI 3 single-crystal X-ray detectors via interfacial dipole engineering
Covalent PFTS monolayer on MAPbI 3 single crystals forms Si–O–Pb bonds and an oriented dipole, simultaneously passivating surface defects and suppressing dark current for high-sensitivity X-ray detection.
- 7 June 2026
- Published by Wiley in Laser & Photonics Reviews
- Vol. 20 (19)
Engineered for Sensitivity: Rare‐Earth‐Doped Gd 3 Ga 5 O 12 Crystals for Stable and High‐Performance X‐Ray Detection
Highly sensitive X‐ray detectors with low detection limits are essential for advancements in medical diagnosis, industrial inspection, and scientific research. In this paper, X‐ray detectors based on neodymium‐doped gadolinium gallium garnet (Nd: GGG) and thulium‐doped gadolinium gallium garnet (Tm: GGG) single crystals were fabricated. Both Nd: GGG and Tm: GGG single crystals demonstrate high crystal quality, a wide bandgap, and good operational stability and reliability. Electrical characterization shows that Tm: GGG possesses a higher room‐temperature bulk resistivity (6.35 × 10 13 Ω cm) and a larger carrier mobility‐lifetime product ( µτ = 4.17 × 10 −4 cm 2 V −1 ). Accordingly, the Au/Tm: GGG/Au detector achieves a high sensitivity of 393.45 µC Gy air −1 cm −2 and a low detection limit of 3.08 nGy air s −1 at 40 keV, with good operational stability. These results suggest the potential of Tm: GGG for high‐sensitivity, low‐dose X‐ray detection with a reasonable response, providing guidance for the optimization of rare‐earth‐doped GGG semiconductors in X‐ray detection applications.
- 7 June 2026
- Published by Wiley in Laser & Photonics Reviews
- Vol. 20 (19)
Engineered for Sensitivity: Rare‐Earth‐Doped Gd 3 Ga 5 O 12 Crystals for Stable and High‐Performance X‐Ray Detection
Highly sensitive X‐ray detectors with low detection limits are essential for advancements in medical diagnosis, industrial inspection, and scientific research. In this paper, X‐ray detectors based on neodymium‐doped gadolinium gallium garnet (Nd: GGG) and thulium‐doped gadolinium gallium garnet (Tm: GGG) single crystals were fabricated. Both Nd: GGG and Tm: GGG single crystals demonstrate high crystal quality, a wide bandgap, and good operational stability and reliability. Electrical characterization shows that Tm: GGG possesses a higher room‐temperature bulk resistivity (6.35 × 10 13 Ω cm) and a larger carrier mobility‐lifetime product ( µτ = 4.17 × 10 −4 cm 2 V −1 ). Accordingly, the Au/Tm: GGG/Au detector achieves a high sensitivity of 393.45 µC Gy air −1 cm −2 and a low detection limit of 3.08 nGy air s −1 at 40 keV, with good operational stability. These results suggest the potential of Tm: GGG for high‐sensitivity, low‐dose X‐ray detection with a reasonable response, providing guidance for the optimization of rare‐earth‐doped GGG semiconductors in X‐ray detection applications.
- Open Access
Study of Single Crystal and X-Ray Detector Performance of Ti3+: β-Ga2O3
Gallium oxide (Ga2O3) is emerging as a promising material for X-ray detectors due to its high sensitivity, high melting point, and stable physicochemical properties. However, intrinsic background shallow donors in raw materials hinder the preparation of high-resistance intrinsic crystals, making doping essential to tailor electrical properties. This study grew Ti3+-doped β-Ga2O3 single crystals via the Edge-defined Film-fed Growth (EFG) method using Ti2O3 as a dopant, achieving high resistivity and a moderate reduction in bandgap. High-resolution X-ray diffraction (HRXRD) showed a rocking curve full width at half maximum (FWHM) of 96.50 arcsec. Compared with the unintentionally doped (UID) crystal, the bandgap exhibited a slight reduction, decreasing from 4.76 eV to 4.59 eV. In the infrared transmission spectra, the onset wavelength of the decrease in transmittance for the Ti3+: β-Ga2O3 crystal showed a distinct redshift relative to that of the UID crystal, indicating effective suppression of free electrons within the crystal. X-ray photoelectron spectroscopy (XPS) revealed that Ti3+ incorporation minimally affected the valence states of Ga and O or the Ga/O ratio, with no significant shift in valence band maximum (EVBM). A metal–semiconductor–metal (MSM) structured X-ray detector fabricated on polished Ti3+: β-Ga2O3 (100) substrate with Ti/Au electrodes exhibited a peak sensitivity of 943.16 μC/(Gy·cm2) at 40 V bias and 2.944 μGy/s dose rate, surpassing the upper sensitivity limit reported for semi-insulating doping bulk β-Ga2O3 detectors. The rise and fall times were 0.23 s and 0.30 s, respectively, with a minimum detectable limit (MDL) of 164.26 nGy/s, demonstrating its potential for high-performance X-ray detection applications.
Open AccessStudy of Single Crystal and X-Ray Detector Performance of Ti3+: β-Ga2O3
Gallium oxide (Ga2O3) is emerging as a promising material for X-ray detectors due to its high sensitivity, high melting point, and stable physicochemical properties. However, intrinsic background shallow donors in raw materials hinder the preparation of high-resistance intrinsic crystals, making doping essential to tailor electrical properties. This study grew Ti3+-doped β-Ga2O3 single crystals via the Edge-defined Film-fed Growth (EFG) method using Ti2O3 as a dopant, achieving high resistivity and a moderate reduction in bandgap. High-resolution X-ray diffraction (HRXRD) showed a rocking curve full width at half maximum (FWHM) of 96.50 arcsec. Compared with the unintentionally doped (UID) crystal, the bandgap exhibited a slight reduction, decreasing from 4.76 eV to 4.59 eV. In the infrared transmission spectra, the onset wavelength of the decrease in transmittance for the Ti3+: β-Ga2O3 crystal showed a distinct redshift relative to that of the UID crystal, indicating effective suppression of free electrons within the crystal. X-ray photoelectron spectroscopy (XPS) revealed that Ti3+ incorporation minimally affected the valence states of Ga and O or the Ga/O ratio, with no significant shift in valence band maximum (EVBM). A metal–semiconductor–metal (MSM) structured X-ray detector fabricated on polished Ti3+: β-Ga2O3 (100) substrate with Ti/Au electrodes exhibited a peak sensitivity of 943.16 μC/(Gy·cm2) at 40 V bias and 2.944 μGy/s dose rate, surpassing the upper sensitivity limit reported for semi-insulating doping bulk β-Ga2O3 detectors. The rise and fall times were 0.23 s and 0.30 s, respectively, with a minimum detectable limit (MDL) of 164.26 nGy/s, demonstrating its potential for high-performance X-ray detection applications.
- 28 May 2026
- Published by Wiley in Advanced Materials
- p. e73525
High‐Entropy Lead‐Free Relaxor Ferroelectric Ceramic with Wide‐Temperature‐Range Self‐Powered X‐Ray Detection
Sensitive and stable x‑ray detectors are essential for low‑dose medical diagnostics. Achieving wide‑temperature operation in materials remains a key challenge for enabling thermally stable, self‐powered x‑ray detection. Herein, a high‐entropy lead‐free relaxor ferroelectric ceramic, 0.85Bi 0.47 Na 0.47 Ba 0.06 TiO 3 ‐0.15Ca 0.7 Ho 0.2 Ti 0.75 Ta 0.2 O 3 (BNBT‐CHTT), is fabricated first. The unique entropy‐stabilized polar nanoregions (PNRs) endow the system with high resistivity and robust spontaneous polarization, underpinning exceptional self‐powered performance across a broad thermal window. Under 70 keV x‐ray irradiation, the detector exhibits excellent stability from 25°C to 185°C, delivering record‐high specific sensitivities of 1117.44–1223.55 µC Gy air −1 cm −2 , self‐powered sensitivities of 597.28–699.78 µC Gy air −1 cm −2 , and low detection limits of 38.7–160.6 nGy a i r s −1 . Notably, distortion‐free x‐ray imaging is demonstrated at 185°C under zero bias, validating the material's practical utility. This work highlights the potential of high‐entropy relaxor ferroelectrics to overcome key limitations of existing detectors and provides a robust platform for next‐generation, low‐power, wide‐temperature‐range x‐ray detection and imaging technologies.
- 28 May 2026
- Published by Wiley in Advanced Materials
- p. e73525
High‐Entropy Lead‐Free Relaxor Ferroelectric Ceramic with Wide‐Temperature‐Range Self‐Powered X‐Ray Detection
Sensitive and stable x‑ray detectors are essential for low‑dose medical diagnostics. Achieving wide‑temperature operation in materials remains a key challenge for enabling thermally stable, self‐powered x‑ray detection. Herein, a high‐entropy lead‐free relaxor ferroelectric ceramic, 0.85Bi 0.47 Na 0.47 Ba 0.06 TiO 3 ‐0.15Ca 0.7 Ho 0.2 Ti 0.75 Ta 0.2 O 3 (BNBT‐CHTT), is fabricated first. The unique entropy‐stabilized polar nanoregions (PNRs) endow the system with high resistivity and robust spontaneous polarization, underpinning exceptional self‐powered performance across a broad thermal window. Under 70 keV x‐ray irradiation, the detector exhibits excellent stability from 25°C to 185°C, delivering record‐high specific sensitivities of 1117.44–1223.55 µC Gy air −1 cm −2 , self‐powered sensitivities of 597.28–699.78 µC Gy air −1 cm −2 , and low detection limits of 38.7–160.6 nGy a i r s −1 . Notably, distortion‐free x‐ray imaging is demonstrated at 185°C under zero bias, validating the material's practical utility. This work highlights the potential of high‐entropy relaxor ferroelectrics to overcome key limitations of existing detectors and provides a robust platform for next‐generation, low‐power, wide‐temperature‐range x‐ray detection and imaging technologies.