Jessica Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jessica Lin has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Wilbur A. Lam
The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, Atlanta, GA, USA
3 shared publications - Anuradha Rao
Department of Pediatrics, Emory University School of Medicine
2 shared publications Julie A. Sullivan
Atlanta Center for Microsystems-Engineered Point-of-Care Technologies, Emory University, USA
2 shared publicationsAdrianna Westbrook
Emory University School of Medicine
1 shared publication- Adrianna Westbrook
Emory University , Atlanta, GA
1 shared publication - Ahmet Faruk Coskun
Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
1 shared publication
Latest Publications
- Top Cited Papers
- 2 April 2025
- Published by Springer Nature in Nature
- Vol. 641 (8065) , 1298-1308
Clinically relevant clot resolution via a thromboinflammation-on-a-chip
Thromboinflammation occurs in various diseases, leading to life-threatening microvascular occlusion with resulting end-organ failure1,2,3,4. Importantly, how microvascular thromboinflammation resolves remains poorly understood due to the small size-scale of microvasculature and the long duration (weeks to months) of this process. Here we introduce a hydrogel-based thromboinflammation-on-a-chip model with long-term culture capabilities to model microvascular thromboinflammation and monitor clot resolution over clinically and physiologically relevant timescales (up to months). Using this system, we mapped out the distinct temporal phases of clot resolution in microvascular thromboinflammation. Using multiplexed RNA fluorescence in situ hybridization in combination with our thromboinflammation-on-a-chip model, we observed that inflammation shifts the endothelium fibrinolytic balance to favour thrombosis and pinpointed neutrophil elastase as a double-edged sword that induces clot resolution but also tissue damage. We then investigated the mechanisms of potential therapeutic agents that either prevent microvascular thrombosis or accelerate clot resolution. Specifically, we observed that, in thromboinflammation, (1) early tissue plasminogen activator administration within 3 h directly improves endothelial barrier function; (2) prophylactic defibrotide and enoxaparin suppress microvascular thromboinflammation through endothelium-mediated mechanisms; and (3) combining enoxaparin with crizanlizumab reduces microvascular occlusion and protects endothelial function in sickle cell disease. These data introduce a paradigm in investigating the underlying mechanisms of thromboinflammatory clot resolution and conducting drug discovery thereof.
- 2 April 2025
- Published by Springer Nature in Nature
- Vol. 641 (8065) , 1298-1308
Top Cited PapersClinically relevant clot resolution via a thromboinflammation-on-a-chip
Thromboinflammation occurs in various diseases, leading to life-threatening microvascular occlusion with resulting end-organ failure1,2,3,4. Importantly, how microvascular thromboinflammation resolves remains poorly understood due to the small size-scale of microvasculature and the long duration (weeks to months) of this process. Here we introduce a hydrogel-based thromboinflammation-on-a-chip model with long-term culture capabilities to model microvascular thromboinflammation and monitor clot resolution over clinically and physiologically relevant timescales (up to months). Using this system, we mapped out the distinct temporal phases of clot resolution in microvascular thromboinflammation. Using multiplexed RNA fluorescence in situ hybridization in combination with our thromboinflammation-on-a-chip model, we observed that inflammation shifts the endothelium fibrinolytic balance to favour thrombosis and pinpointed neutrophil elastase as a double-edged sword that induces clot resolution but also tissue damage. We then investigated the mechanisms of potential therapeutic agents that either prevent microvascular thrombosis or accelerate clot resolution. Specifically, we observed that, in thromboinflammation, (1) early tissue plasminogen activator administration within 3 h directly improves endothelial barrier function; (2) prophylactic defibrotide and enoxaparin suppress microvascular thromboinflammation through endothelium-mediated mechanisms; and (3) combining enoxaparin with crizanlizumab reduces microvascular occlusion and protects endothelial function in sickle cell disease. These data introduce a paradigm in investigating the underlying mechanisms of thromboinflammatory clot resolution and conducting drug discovery thereof.
- Open Access
Validation of Saliva as the Clinical Specimen Type for a University-Wide COVID-19 Surveillance Program
At the beginning of the COVID-19 pandemic, the Georgia Institute of Technology made the decision to keep the university doors open for on-campus attendance. To manage COVID-19 infection rates, internal resources were applied to develop and implement a mass asymptomatic surveillance program. The objective was to identify infections early for proper follow-on verification testing, contact tracing, and quarantine/isolation as needed. Program success depended on frequent and voluntary sample collection from over 40,000 students, faculty, and staff personnel. At that time, the nasopharyngeal (NP) swab, not saliva, was the main accepted sample type for COVID-19 testing. However, due to collection discomfort and the inability to be self-collected, the NP swab was not feasible for voluntary and frequent self-collection. Therefore, saliva was selected as the clinical sample type and validated. A saliva collection kit and a sample processing and analysis workflow were developed. The results of a clinical sample-type comparison study between co-collected and matched NP swabs and saliva samples showed 96.7% positive agreement and 100% negative agreement. During the Fall 2020 and Spring 2021 semesters, 319,988 samples were collected and tested. The program resulted in maintaining a low overall mean positivity rate of 0.78% and 0.54% for the Fall 2020 and Spring 2021 semesters, respectively. For this high-throughput asymptomatic COVID-19 screening application, saliva was an exceptionally good sample type.
Open AccessValidation of Saliva as the Clinical Specimen Type for a University-Wide COVID-19 Surveillance Program
At the beginning of the COVID-19 pandemic, the Georgia Institute of Technology made the decision to keep the university doors open for on-campus attendance. To manage COVID-19 infection rates, internal resources were applied to develop and implement a mass asymptomatic surveillance program. The objective was to identify infections early for proper follow-on verification testing, contact tracing, and quarantine/isolation as needed. Program success depended on frequent and voluntary sample collection from over 40,000 students, faculty, and staff personnel. At that time, the nasopharyngeal (NP) swab, not saliva, was the main accepted sample type for COVID-19 testing. However, due to collection discomfort and the inability to be self-collected, the NP swab was not feasible for voluntary and frequent self-collection. Therefore, saliva was selected as the clinical sample type and validated. A saliva collection kit and a sample processing and analysis workflow were developed. The results of a clinical sample-type comparison study between co-collected and matched NP swabs and saliva samples showed 96.7% positive agreement and 100% negative agreement. During the Fall 2020 and Spring 2021 semesters, 319,988 samples were collected and tested. The program resulted in maintaining a low overall mean positivity rate of 0.78% and 0.54% for the Fall 2020 and Spring 2021 semesters, respectively. For this high-throughput asymptomatic COVID-19 screening application, saliva was an exceptionally good sample type.
- Open Access
Standardization and Comparison of Emergency Use Authorized COVID-19 Assays and Testing Laboratories
Summary: SARS-CoV-2, the causal agent of the global COVID-19 pandemic, made its appearance at the end of 2019 and is still circulating in the population. The pandemic led to an urgent need for fast, reliable, and widely available testing. After December 2020, the emergence of new variants of SARS-CoV-2 led to additional challenges since new and existing tests had to detect variants to the same extent as the original Wuhan strain. When an antigen-based test is submitted to the Food and Drug Administration (FDA) for Emergency Use Authorization (EUA) consideration it is benchmarked against PCR comparator assays, which yield cycle threshold (C T ) data as an indirect indicator of viral load – the lower the C T , the higher the viral load of the sample and the higher the C T , the lower the viral load. The FDA mandates that 10-20% of clinical samples used to evaluate the antigen test have to be low positive. Low positive, as defined by the FDA, are clinical samples in which the C T of the SARS-CoV-2 target gene is within 3 C T of the mean C T value of the approved comparator test’s Limit of Detection (LOD). While all comparator tests are PCR-based, the results from different PCR assays used are not uniform. Results vary depending on assay platform, target gene, LOD and laboratory methodology. The emergence and dominance of the Omicron variant further challenged this approach as the fraction of low positive clinical samples dramatically increased as compared to earlier SARS-CoV-2 variants. This led to 20-40% of clinical samples having high C T values and therefore assays vying for an EUA were failing to achieve the 80% Percent Positive Agreement (PPA) threshold required. Here we describe the methods and statistical analyses used to establish a predefined cutoff, based on genome copies per ml (GE/ml) to classify samples as low positive (less than the cutoff GE/ml) or high positive (greater than the cutoff GE/mL). C T 30 for the E gene target using Cobas® SARS-CoV-2-FluA/B platform performed at TriCore Reference Laboratories, and this low positive cutoff value was used for two EUA authorizations. Using droplet digital PCR and methods described here, a value 49,447.72 was determined as the GE/ml equivalent for the low positive cutoff. The C T cutoff corresponding to 49447.72 GE/ml was determined across other platforms and laboratories. The methodology and statistical analysis described here can now be used for standardization of all comparators used for FDA submissions with a goal towards establishing uniform criteria for EUA authorization. Motivation: The motivation for this work was the need to establish a predefined cutoff based on genome copies per ml (GE/ml) rather than Ct, which can vary depending on the laboratory and assay used. A GE/ml-based threshold was necessary to define what constituted ‘low positives” for samples that were included in data sets submitted to the FDA for emergency use approval for SARS-CoV-2 antigen tests.
Open AccessStandardization and Comparison of Emergency Use Authorized COVID-19 Assays and Testing Laboratories
Summary: SARS-CoV-2, the causal agent of the global COVID-19 pandemic, made its appearance at the end of 2019 and is still circulating in the population. The pandemic led to an urgent need for fast, reliable, and widely available testing. After December 2020, the emergence of new variants of SARS-CoV-2 led to additional challenges since new and existing tests had to detect variants to the same extent as the original Wuhan strain. When an antigen-based test is submitted to the Food and Drug Administration (FDA) for Emergency Use Authorization (EUA) consideration it is benchmarked against PCR comparator assays, which yield cycle threshold (C T ) data as an indirect indicator of viral load – the lower the C T , the higher the viral load of the sample and the higher the C T , the lower the viral load. The FDA mandates that 10-20% of clinical samples used to evaluate the antigen test have to be low positive. Low positive, as defined by the FDA, are clinical samples in which the C T of the SARS-CoV-2 target gene is within 3 C T of the mean C T value of the approved comparator test’s Limit of Detection (LOD). While all comparator tests are PCR-based, the results from different PCR assays used are not uniform. Results vary depending on assay platform, target gene, LOD and laboratory methodology. The emergence and dominance of the Omicron variant further challenged this approach as the fraction of low positive clinical samples dramatically increased as compared to earlier SARS-CoV-2 variants. This led to 20-40% of clinical samples having high C T values and therefore assays vying for an EUA were failing to achieve the 80% Percent Positive Agreement (PPA) threshold required. Here we describe the methods and statistical analyses used to establish a predefined cutoff, based on genome copies per ml (GE/ml) to classify samples as low positive (less than the cutoff GE/ml) or high positive (greater than the cutoff GE/mL). C T 30 for the E gene target using Cobas® SARS-CoV-2-FluA/B platform performed at TriCore Reference Laboratories, and this low positive cutoff value was used for two EUA authorizations. Using droplet digital PCR and methods described here, a value 49,447.72 was determined as the GE/ml equivalent for the low positive cutoff. The C T cutoff corresponding to 49447.72 GE/ml was determined across other platforms and laboratories. The methodology and statistical analysis described here can now be used for standardization of all comparators used for FDA submissions with a goal towards establishing uniform criteria for EUA authorization. Motivation: The motivation for this work was the need to establish a predefined cutoff based on genome copies per ml (GE/ml) rather than Ct, which can vary depending on the laboratory and assay used. A GE/ml-based threshold was necessary to define what constituted ‘low positives” for samples that were included in data sets submitted to the FDA for emergency use approval for SARS-CoV-2 antigen tests.