JLJiYoung Lee

JiYoung Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


JiYoung Lee has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Ji Hun Park

    Department of Cogno-Mechatronics Engineering, Pusan National University, Miryang, Republic of Korea

    1 shared publication
  • Jongsung Kim

    Department of Chemical and Biological Engineering, Gachon University, Seongnam-si, Republic of Korea

    1 shared publication
  • Jose Paul

    Department of Chemical and Biological Engineering Gachon University 1342, Seongnam Daero Seongnam-si Gyeonggi-do 13120 Republic of Korea

    1 shared publication
  • Kee-Tae Kim

    Department of Chemical and Biomolecular Engineering, Sogang University, Seoul, Republic of Korea

    1 shared publication
  • Rolf A. Deininger

    Department of Environmental Health Sciences, School of Public Health, University of Michigan, 109 S. Observatory, Ann Arbor, MI 48109, USA

    1 shared publication
  • Roopkumar Sangubotla

    Department of Chemical, Biomolecular, and Battery Engineering, Gachon University, 1342 Seongnam Daero, Seongnam-si 13120, Republic of Korea

    1 shared publication

Latest Publications

  • MXene‐Coated Liposome‐Quercetin‐Functionalized Gold Nanoparticles for Electrochemical Detection of Dopamine

    by Jiyoung Lee, Jose Paul, Roopkumar Sangubotla, Jongsung Kim

    This study reports a novel electrochemical approach for selective dopamine (DA) sensing. DA is a potential neurological biomarker for human aging and other neurodegenerative disorders, particularly Alzheimer's disease. The sensor is constructed using titanium‐based MXene and quercetin (Qu)‐loaded liposome functionalized with gold nanoparticles (AuNPs) (MXene/Lip‐Qu@AuNPs). MXene/Lip‐Qu@AuNPs is coated on a glassy carbon electrode (GCE) for DA sensing. The MXene provides high conductivity for electrochemical measurements of DA. The modified GCE is employed for DA sensing against various interferants, including ascorbic acid, aspartic acid, arginine, and cysteine. The proposed MXene/Lip‐Qu@AuNP‐based GCE exhibits sufficient detection limits of 0.35 and 0.72 μM for DA sensing using cyclic voltammetry and differential pulse voltammetry methods within a linear concentration range of 1–10 μM, respectively. The proposed sensor is used to detect DA in human serum samples. Hence, the proposed novel sensor is highly convenient and provides highly selective and sensitive DA detection.


  • Studies on the fabrication and characteristics of photoelectrochemical cells using IrO2-coated TiO2 photoanode for Z-scheme water splitting and perovskite solar cell bias

    by Ji-Young Lee, Kee-Tae Kim, Ji Hun Park, Se Young Oh

    (2018). Studies on the fabrication and characteristics of photoelectrochemical cells using IrO2-coated TiO2 photoanode for Z-scheme water splitting and perovskite solar cell bias. Molecular Crystals and Liquid Crystals: Vol. 662, The 21st International Symposium on Advanced Display Materials and Devices (ADMD 2017): Part I, pp. 75-81.


  • Open Access

    A rapid screening method for the detection of viable spores in powder using bioluminescence

    by JiYoung Lee, Rolf A. Deininger

    A rapid diagnosis of a biological threat in a powder sample is important for first responders who have to make decisions on‐site. The present culture‐based method does not provide timely results, which is a critical barrier for a quick response when a suspicious powder sample is found. The ATP bioluminescence method, combined with a heat shock, was investigated to determine the presence of spores in powder. The results show that only spore‐containing powder samples provided a dramatic increase in the bioluminescence signal after the heat shock, which induces germination of the spores. Various conditions were tested to find the most effective and rapid germination procedure. Elevated temperatures (37°C and 50°C) were more effective in germination than room temperature. At 50°C, a double‐strength germinant was more effective in germination than the regular strength. The 37°C/15 min procedure induced the germination of spores most effectively, while a 50°C/2 min procedure provided reasonably high signals, so it could make the entire procedure even faster (< 5 min). The detection limit of the bioluminescence method is < 100 spores. Copyright © 2004 John Wiley & Sons, Ltd.