Maddy Yeh
Maddy Yeh has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Harrison Specht
Parallel Squared Technology Institute
3 shared publications - Kevin McDonnell
Parallel Squared Technology Institute
3 shared publications - Nikolai Slavov
Northeastern University
3 shared publications - Jason Derks
Parallel Squared Technology Institute, Watertown, MA, USA
2 shared publications - Nathan Wamsley
Washington University in St. Louis 2
2 shared publications - Sarah N. Sipe
Parallel Squared Technology Institute
2 shared publications
Latest Publications
- Open Access
PSMtags improve peptide sequencing and throughput in sensitive proteomics
Mass spectrometry-based proteomics enables comprehensive characterization of proteins, but label-free approaches are challenging to scale to thousands of samples per day (SPD). Multiplexed data-independent approaches (plexDIA) can increase throughput but lack the mass tags to enable it. Here, we systematically screened a library of 576 compounds and identified several small molecules that, when conjugated to peptides, improve their detection and sequence identification. The lead molecule, PSMtag, substantially increases the detection of fragment b-ions, which increases the confidence of sequence identification and enhances de novo sequencing. PSMtags allow 9-plexDIA, using only stable isotopes of carbon, oxygen and nitrogen. As a result, it allows increasing sample throughput for plexDIA workflows. We demonstrate 1,130 SPD with 9-plexDIA from single-cell-level human proteomes, acquiring 27,520 protein datapoints in the same time label-free methods acquire 3,216. Our approach constitutes an expandable framework for developing mass tags to overcome existing limitations in multiplexed proteomics.
Open AccessPSMtags improve peptide sequencing and throughput in sensitive proteomics
Mass spectrometry-based proteomics enables comprehensive characterization of proteins, but label-free approaches are challenging to scale to thousands of samples per day (SPD). Multiplexed data-independent approaches (plexDIA) can increase throughput but lack the mass tags to enable it. Here, we systematically screened a library of 576 compounds and identified several small molecules that, when conjugated to peptides, improve their detection and sequence identification. The lead molecule, PSMtag, substantially increases the detection of fragment b-ions, which increases the confidence of sequence identification and enhances de novo sequencing. PSMtags allow 9-plexDIA, using only stable isotopes of carbon, oxygen and nitrogen. As a result, it allows increasing sample throughput for plexDIA workflows. We demonstrate 1,130 SPD with 9-plexDIA from single-cell-level human proteomes, acquiring 27,520 protein datapoints in the same time label-free methods acquire 3,216. Our approach constitutes an expandable framework for developing mass tags to overcome existing limitations in multiplexed proteomics.
- Open Access
timePlex: Increasing mass spectrometry throughput using time-encoded sample multiplexing
Liquid chromatography-mass spectrometry (LC-MS) can enable precise and accurate quantification of analytes at high-sensitivity, but the rate at which samples can be analyzed remains limited. Throughput can be increased by data-independent-acquisition (DIA) using short separation times and by multiplexing samples in the mass domain with plexDIA; yet multiplexing along one dimension scales throughput only linearly with plex. To enable combinatorial scaling of proteomics throughput, we developed a complementary DIA strategy that multiplexes samples in the time domain, termed `timePlex'. timePlex staggers and overlaps the separation periods of individual samples. This strategy is orthogonal to isotopic multiplexing, which enables combinatorial multiplexing in mass and time domains, and thus multiplicatively increased throughput. We demonstrate this with a 27-plex (3-timePlex and 9-plexDIA) exceeding 1,200 samples (4M protein datapoints) per day. These results establish timePlex as a framework for multiplexing both label-free and labeled samples that supports sensitive and accurate protein quantification and combinatorial scaling.
Open AccesstimePlex: Increasing mass spectrometry throughput using time-encoded sample multiplexing
Liquid chromatography-mass spectrometry (LC-MS) can enable precise and accurate quantification of analytes at high-sensitivity, but the rate at which samples can be analyzed remains limited. Throughput can be increased by data-independent-acquisition (DIA) using short separation times and by multiplexing samples in the mass domain with plexDIA; yet multiplexing along one dimension scales throughput only linearly with plex. To enable combinatorial scaling of proteomics throughput, we developed a complementary DIA strategy that multiplexes samples in the time domain, termed `timePlex'. timePlex staggers and overlaps the separation periods of individual samples. This strategy is orthogonal to isotopic multiplexing, which enables combinatorial multiplexing in mass and time domains, and thus multiplicatively increased throughput. We demonstrate this with a 27-plex (3-timePlex and 9-plexDIA) exceeding 1,200 samples (4M protein datapoints) per day. These results establish timePlex as a framework for multiplexing both label-free and labeled samples that supports sensitive and accurate protein quantification and combinatorial scaling.
- Open Access
JMod: Joint modeling of mass spectra for empowering multiplexed DIA proteomics
Parallelization of data acquisition substantially increases the throughput of mass spectrometry-based proteomics. However, parallelization also increases the density of mass spectra and consequently the overlap between ions, frustrating their analysis. To improve sequence identification and quantification from such spectra, we developed an open-source software for Joint Modeling of mass spectra (JMod). JMod models overlapping peaks as linear super-positions of their components in both MS1 and MS2 space, which permits multiplexed DIA with smaller mass offsets to increase the multiplexing capacity and thus proteomics through-put for a given plexDIA tag. This enables 9-plexDIA using 2 Da offset PSMtags, increasing throughput 9-fold while preserving quantitative accuracy and coverage depth. Furthermore, we use JMod to deconvolve simultaneous labeling by mass tags and heavy amino acids, thus increasing the throughput of metabolic pulse experiments measuring protein synthesis and degradation rates in single cells from mouse liver. By supporting enhanced decoding of highly multiplexed DIA spectra, JMod provides an open and flexible software that increases the throughput of sensitive proteomics.
Open AccessJMod: Joint modeling of mass spectra for empowering multiplexed DIA proteomics
Parallelization of data acquisition substantially increases the throughput of mass spectrometry-based proteomics. However, parallelization also increases the density of mass spectra and consequently the overlap between ions, frustrating their analysis. To improve sequence identification and quantification from such spectra, we developed an open-source software for Joint Modeling of mass spectra (JMod). JMod models overlapping peaks as linear super-positions of their components in both MS1 and MS2 space, which permits multiplexed DIA with smaller mass offsets to increase the multiplexing capacity and thus proteomics through-put for a given plexDIA tag. This enables 9-plexDIA using 2 Da offset PSMtags, increasing throughput 9-fold while preserving quantitative accuracy and coverage depth. Furthermore, we use JMod to deconvolve simultaneous labeling by mass tags and heavy amino acids, thus increasing the throughput of metabolic pulse experiments measuring protein synthesis and degradation rates in single cells from mouse liver. By supporting enhanced decoding of highly multiplexed DIA spectra, JMod provides an open and flexible software that increases the throughput of sensitive proteomics.
Investigation into the performance and stability of immobilized and coated polysaccharide columns in supercritical fluid chromatography
In this study, the performance of the widely used “golden four” coated chiral stationary phases (Chiralpak AD‐3, Chiralcel OD‐3, Chiralpak AS‐3, and Chiralcel OJ‐3) was compared with their corresponding immobilized versions (Chiralpak IA‐3, Chiralpak IB‐3, Chiralpak IB N‐3, Chiralpak IH‐3, and Chiralpak IJ‐3) under supercritical fluid chromatography (SFC) conditions with a set of 30 racemic compounds. Using the traditional modifiers, methanol and isopropanol, the immobilized columns (Chiralpak IB N‐3 and Chiralpak IH‐3) showed an improved general ability to successfully resolve the enantiomers of the target analytes relative to their coated versions (Chiralcel OD‐3 and Chiralpak AS‐3), while the coated columns (Chiralpak AD‐3, Chiralcel OD‐3, and Chiralcel OJ‐3) performed better than their immobilized versions (Chiralpak IA‐3, Chiralpak IB‐3, and Chiralpak IJ‐3). An investigation of the non‐traditional modifiers, dichloromethane, ethyl acetate, and tetrahydrofuran with immobilized columns, revealed a generally decreased ability to successfully resolve the enantiomers of the target analytes, relative to the use of the traditional modifiers, methanol and isopropanol. The stability of the coated columns (Chiralpak AD‐H and Chiralcel OD‐H) was evaluated by injecting “forbidden” solvents, including dichloromethane, dimethyl sulfoxide, and tetrahydrofuran. After 200 injections of these solvents on coated columns, the retention factors and resolutions slightly decreased, and a significant increase in column backpressure was observed, indicating some degree of stationary phase degradation.
Investigation into the performance and stability of immobilized and coated polysaccharide columns in supercritical fluid chromatography
In this study, the performance of the widely used “golden four” coated chiral stationary phases (Chiralpak AD‐3, Chiralcel OD‐3, Chiralpak AS‐3, and Chiralcel OJ‐3) was compared with their corresponding immobilized versions (Chiralpak IA‐3, Chiralpak IB‐3, Chiralpak IB N‐3, Chiralpak IH‐3, and Chiralpak IJ‐3) under supercritical fluid chromatography (SFC) conditions with a set of 30 racemic compounds. Using the traditional modifiers, methanol and isopropanol, the immobilized columns (Chiralpak IB N‐3 and Chiralpak IH‐3) showed an improved general ability to successfully resolve the enantiomers of the target analytes relative to their coated versions (Chiralcel OD‐3 and Chiralpak AS‐3), while the coated columns (Chiralpak AD‐3, Chiralcel OD‐3, and Chiralcel OJ‐3) performed better than their immobilized versions (Chiralpak IA‐3, Chiralpak IB‐3, and Chiralpak IJ‐3). An investigation of the non‐traditional modifiers, dichloromethane, ethyl acetate, and tetrahydrofuran with immobilized columns, revealed a generally decreased ability to successfully resolve the enantiomers of the target analytes, relative to the use of the traditional modifiers, methanol and isopropanol. The stability of the coated columns (Chiralpak AD‐H and Chiralcel OD‐H) was evaluated by injecting “forbidden” solvents, including dichloromethane, dimethyl sulfoxide, and tetrahydrofuran. After 200 injections of these solvents on coated columns, the retention factors and resolutions slightly decreased, and a significant increase in column backpressure was observed, indicating some degree of stationary phase degradation.