Sachiko Osada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sachiko Osada has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Hideki Kuramitz
Department of Natural and Environmental Sciences, Faculty of Science, Academic Assembly, University of Toyama, Gofuku 3190, Toyama 930-8555, Japan
3 shared publications - Kazuto Sazawa
Department of Natural and Environmental Sciences, Faculty of Science, Academic Assembly, University of Toyama, Toyama, Japan
3 shared publications - Noriko Hata
Graduate School of Science and Engineering, University of Toyama, Gofuku 3190, Toyama 930-8555, Japan
3 shared publications - Shigeru Taguchi
Graduate School of Science and Engineering, University of Toyama, Gofuku 3190, Toyama 930-8555, Japan
3 shared publications - Nozomi Kohama
Hydrogen Isotope Science Research Center, University of Toyama, 3190 Gofuku, Toyama 930-8555, Japan
2 shared publications - Takuya Okazaki
Department of Applied Chemistry for Environment, Tokyo Metropolitan University, 1-1 Minami-osawa, Hachioji, Tokyo 192-0397, Japan
2 shared publications
Latest Publications
- Open Access
Rapid and Facile Organic Ion-Associate Liquid-Phase Extraction and Spectrophotometric Quantification of Nitrite in Environmental Water Samples
Nitrite is a health and environmental hazard and pollutes water sources globally, but sensitive, rapid, and facile quantification methods are lacking. Herein, we report a method for extracting and quantifying low-concentration nitrite in surface water using minimal sample and solvent volumes. The nitrite reacted with sulfanilamide and N-1-naphthylethylenediammonium dichloride (NED), yielding an azo dye for extraction into an organic ion-associate liquid phase (IALP) formed in situ using ethylhexyloxypropylammonium and dodecyl sulfate ions. The addition of sodium acetate increased the pH, decreasing the cation charge from +2 to +1, improving extraction efficiency. Further, adding NaCl doubled the IALP volume, reduced the required standing time, and minimally affected absorbance, and adding concentrated HCl to the IALP enhanced the absorbance intensity via dye protonation. Crucially, the method achieved a 30-fold concentration factor compared to traditional pre-treatment methods, even without centrifugation, as well as a limit of detection of 0.09 µg NO2-N/L. Spiked recovery tests with river and seawater samples (93–103%) matched those of established methods. Digital imaging of IALP-extracted lake water yielded a limit of detection of 0.4 µg NO2-N/L. The method is a sensitive, efficient approach for nitrite detection, enabling rapid environmental monitoring via spectrophotometry and digital imaging.
Open AccessRapid and Facile Organic Ion-Associate Liquid-Phase Extraction and Spectrophotometric Quantification of Nitrite in Environmental Water Samples
Nitrite is a health and environmental hazard and pollutes water sources globally, but sensitive, rapid, and facile quantification methods are lacking. Herein, we report a method for extracting and quantifying low-concentration nitrite in surface water using minimal sample and solvent volumes. The nitrite reacted with sulfanilamide and N-1-naphthylethylenediammonium dichloride (NED), yielding an azo dye for extraction into an organic ion-associate liquid phase (IALP) formed in situ using ethylhexyloxypropylammonium and dodecyl sulfate ions. The addition of sodium acetate increased the pH, decreasing the cation charge from +2 to +1, improving extraction efficiency. Further, adding NaCl doubled the IALP volume, reduced the required standing time, and minimally affected absorbance, and adding concentrated HCl to the IALP enhanced the absorbance intensity via dye protonation. Crucially, the method achieved a 30-fold concentration factor compared to traditional pre-treatment methods, even without centrifugation, as well as a limit of detection of 0.09 µg NO2-N/L. Spiked recovery tests with river and seawater samples (93–103%) matched those of established methods. Digital imaging of IALP-extracted lake water yielded a limit of detection of 0.4 µg NO2-N/L. The method is a sensitive, efficient approach for nitrite detection, enabling rapid environmental monitoring via spectrophotometry and digital imaging.
- Open Access
- 2 June 2024
- Published by MDPI AG in Separations
- Vol. 11 (6) , 173
In Situ Formed Organic Ion-Associate Liquid-Phase Microextraction without Centrifugation from Aqueous Solutions Using Thymol Blue and Estrogens
In this study, we present a method for ion-associated liquid phase (IALP) separation and concentration of analytes from an aqueous matrix into an IALP formed in situ by the charge neutralization reaction of organic cations and anions, without centrifugation. The effects of various factors on the extraction efficiency and other parameters are investigated, whereas no instrumental stirring, such as vortexing or ultrasonics, is required because the solvent (IALP) is formed in situ. The organic cation and anion used are ethylhexyloxypropylammonium and dodecyl sulfate, respectively. The developed in situ IALP microextraction method for phase separation without centrifugation is tested using the thymol blue dye and several endocrine disruptors. The tested endocrine disruptors (bisphenol A, 17β-estradiol, 17α-ethinylestradiol, and estrone) are analyzed via high-performance liquid chromatography/fluorescence detection, with respective detection limits of 0.02, 0.02, 0.02, and 0.4 μg L−1, and the corresponding enrichment factor ranging from 47 to 71. This IALP microextraction method can be used to separate and concentrate environmental water samples of different matrices. The employed IALP is fast and easy to use, enables an approximately 100-fold analyte concentration, and has a high affinity for estrogens, thus holding promise for the separation, concentration, and quantitation of diverse trace analytes.
- 2 June 2024
- Published by MDPI AG in Separations
- Vol. 11 (6) , 173
Open AccessIn Situ Formed Organic Ion-Associate Liquid-Phase Microextraction without Centrifugation from Aqueous Solutions Using Thymol Blue and Estrogens
In this study, we present a method for ion-associated liquid phase (IALP) separation and concentration of analytes from an aqueous matrix into an IALP formed in situ by the charge neutralization reaction of organic cations and anions, without centrifugation. The effects of various factors on the extraction efficiency and other parameters are investigated, whereas no instrumental stirring, such as vortexing or ultrasonics, is required because the solvent (IALP) is formed in situ. The organic cation and anion used are ethylhexyloxypropylammonium and dodecyl sulfate, respectively. The developed in situ IALP microextraction method for phase separation without centrifugation is tested using the thymol blue dye and several endocrine disruptors. The tested endocrine disruptors (bisphenol A, 17β-estradiol, 17α-ethinylestradiol, and estrone) are analyzed via high-performance liquid chromatography/fluorescence detection, with respective detection limits of 0.02, 0.02, 0.02, and 0.4 μg L−1, and the corresponding enrichment factor ranging from 47 to 71. This IALP microextraction method can be used to separate and concentrate environmental water samples of different matrices. The employed IALP is fast and easy to use, enables an approximately 100-fold analyte concentration, and has a high affinity for estrogens, thus holding promise for the separation, concentration, and quantitation of diverse trace analytes.
- Open Access
In Situ Formation of a Relatively Transparent Ion-Associate Liquid Phase from an Aqueous Phase and Its Application to Microextraction/High-Performance Liquid Chromatography–Fluorescence Detection of Bisphenol A in Water
The design of a simple approach enabling the detection of bisphenol A (BPA) in water samples without the need for large amounts of solvents is of utmost importance. This paper reports a simple method for the separation, concentration, and quantification of BPA in water samples using high-performance liquid chromatography with fluorescence detection (HPLC-FLD) after its microextraction into an in situ formed organic ion-associate (IA) liquid phase (LP). Novel IA phase components without conjugated double bonds, such as benzene rings, were investigated. Ethylhexyloxypropylamine hydrochloride and sodium dodecyl sulfate solutions were added to the water samples to form IAs. The aqueous phase and ion-associate liquid phase (IALP) were separated by centrifugation. The aqueous phase was removed, and the liquid phase was recovered and measured using HPLC-FLD or HPLC-electrochemical detection (ECD). The concentrated phase (IALP) had a relatively low viscosity and could be injected directly into the chromatograph without dissolving it in organic solvents. The detection limits for BPA by HPLC-FLD and HPLC-ECD were 0.009 and 0.3 µg L−1, respectively.
Open AccessIn Situ Formation of a Relatively Transparent Ion-Associate Liquid Phase from an Aqueous Phase and Its Application to Microextraction/High-Performance Liquid Chromatography–Fluorescence Detection of Bisphenol A in Water
The design of a simple approach enabling the detection of bisphenol A (BPA) in water samples without the need for large amounts of solvents is of utmost importance. This paper reports a simple method for the separation, concentration, and quantification of BPA in water samples using high-performance liquid chromatography with fluorescence detection (HPLC-FLD) after its microextraction into an in situ formed organic ion-associate (IA) liquid phase (LP). Novel IA phase components without conjugated double bonds, such as benzene rings, were investigated. Ethylhexyloxypropylamine hydrochloride and sodium dodecyl sulfate solutions were added to the water samples to form IAs. The aqueous phase and ion-associate liquid phase (IALP) were separated by centrifugation. The aqueous phase was removed, and the liquid phase was recovered and measured using HPLC-FLD or HPLC-electrochemical detection (ECD). The concentrated phase (IALP) had a relatively low viscosity and could be injected directly into the chromatograph without dissolving it in organic solvents. The detection limits for BPA by HPLC-FLD and HPLC-ECD were 0.009 and 0.3 µg L−1, respectively.