SKSergey I. Kim

Sergey I. Kim

*This is an algorithmically generated author record based on publicly available information.

Sergey I. Kim has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Impact of a positive end-expiratory pressure on oxygenation, respiratory compliance, and hemodynamics in obese patients undergoing laparoscopic surgery in reverse Trendelenburg position: a systematic review and meta-analysis of randomized controlled trials

    by Gulfairus A. Yessenbayeva, Aizhan M. Meyerbekova, Sergey I. Kim, Murat B. Zhumabayev, Gulbanu S. Berdiyarova, Sanzhar B. Shalekenov, Dinara S. Zharlyganova, Irina Y. Mukatova, Yekaterina A. Yukhnevich, Dmitriy A. Klyuyev, et al.

    High and individual positive end-expiratory pressure (PEEP) during laparoscopic surgery may improve oxygenation and respiratory mechanics. We searched RCTs in PubMed, Cochrane Library, Web of Science, and Google Scholar from from from January 2000 to December 2023 comparing the different intraoperative PEEP (low PEEP (LPEEP): 0–5 mbar; moderate PEEP (MPEEP): 6–9 mbar; high PEEP (HPEEP): >=10 mbar; individualized PEEP (iPEEP): PEEP set by special physiological technique) on arterial oxygenation, respiratory compliance (Cdyn) or driving pressure, mean arterial pressure (MAP), and heart rate (HR) in patients during laparoscopic surgery in reverse Trendelenburg position. We calculated mean differences (MD) with 95% confidence intervals (CI), and predictive intervals (PI) using random-effects models. The Cochrane Bias Risk Assessment Tool was applied. 8 RCTs (n = 425) met the inclusion criteria. HPEEP vs. LPEEP increased PaO2/FiO2 (+ 129.93 [+ 75.20; +184.65] mmHg, p < 0.0001) with high variation of true effect (Chi2 34.92, p < 0.0001; I2 89%). iPEEP vs. LPEEP also increased PaO2/FiO2 + 130.23 [+ 57.18; +203.27] mmHg, p = 0.0005) with high variation of true effect (Chi2 26.95, p < 0.0001; I2 93%). HPEEP vs. LPEEP increased Cdyn (+ 15.06 [5.47; +24.65] ml/mbar, p = 0.002) with high variation of true effect (Chi2 93.16, p < 0.0001; I2 96%). iPEEP vs. LPEEP increased Cdyn (+ 22.46 [+ 8.56; +36.35] ml/mbar, p = 0.002) with high variability of the true effect (Chi2 53.92, p < 0.0001; I2 96%). HPEEP group had higher MAP as compared to LPEEP) + 4.36 [+ 0.36;+8.36], p = 0.03), variability of the true effect was nonsignificant. HR did nit differ between all comparisons. In patients with obesity undergoing surgery in the reverse Trendelenburg position HPEEP and iPEEP may improve oxygenation, decrease driving pressure, and increase dynamic compliance compared to LPEEP with high variation of true effect without relevant hemodynamic compromise. Data with MPEEP comparisons are inconclusive. CRD42023488971; registered December 14, 2023.


  • Open Access

    Impact of a positive end-expiratory pressure strategy on oxygenation, respiratory compliance, and hemodynamics during laparoscopic surgery in non-obese patients: a systematic review and meta-analysis of randomized controlled trials

    by Gulfairus A. Yessenbayeva, Yekaterina A. Yukhnevich, Zaukiya K. Khamitova, Sergey I. Kim, Murat B. Zhumabayev, Gulbanu S. Berdiyarova, Sanzhar B. Shalekenov, Irina Y. Mukatova, Andrey I. Yaroshetskiy

    Background: Higher positive end-expiratory pressure (PEEP) during laparoscopic surgery may increase oxygenation and respiratory compliance. This meta-analysis aimed to compare the impact of different intraoperative PEEP strategies on arterial oxygenation, compliance, and hemodynamics during laparoscopic surgery in non-obese patients. Methods: We searched RCTs in PubMed, Cochrane Library, Web of Science, and Google Scholar from January 2012 to April 2022 comparing the different intraoperative PEEP (Low PEEP (LPEEP): 0–4 mbar; Moderate PEEP (MPEEP): 5–8 mbar; high PEEP (HPEEP): >8 mbar; individualized PEEP - iPEEP) on arterial oxygenation, respiratory compliance (Cdyn), mean arterial pressure (MAP), and heart rate (HR). We calculated mean differences (MD) with 95% confidence intervals (CI), and predictive intervals (PI) using random-effects models. The Cochrane Bias Risk Assessment Tool was applied. Results: 21 RCTs (n = 1554) met the inclusion criteria. HPEEP vs. LPEEP increased PaO2 (+ 29.38 [16.20; 42.56] mmHg, p < 0.0001) or PaO2/FiO2 (+ 36.7 [+ 2.23; +71.70] mmHg, p = 0.04). HPEEP vs. MPEEP increased PaO2 (+ 22.00 [+ 1.11; +42.88] mmHg, p = 0.04) or PaO2/FiO2 (+ 42.7 [+ 2.74; +82.67] mmHg, p = 0.04). iPEEP vs. MPEEP increased PaO2/FiO2 (+ 115.2 [+ 87.21; +143.20] mmHg, p < 0.001). MPEEP vs. LPEP, and HPEEP vs. MPEEP increased PaO2 or PaO2/FiO2 significantly with different heterogeneity. HPEEP vs. LPEEP increased Cdyn (+ 7.87 [+ 1.49; +14.25] ml/mbar, p = 0.02). MPEEP vs. LPEEP, and HPEEP vs. MPEEP did not impact Cdyn (p = 0.14 and 0.38, respectively). iPEEP vs. LPEEP decreased driving pressure (-4.13 [-2.63; -5.63] mbar, p < 0.001). No significant differences in MAP or HR were found between any subgroups. Conclusion: HPEEP and iPEEP during PNP in non-obese patients could promote oxygenation and increase Cdyn without clinically significant changes in MAP and HR. MPEEP could be insufficient to increase respiratory compliance and improve oxygenation. LPEEP may lead to decreased respiratory compliance and worsened oxygenation. Prospero registration: CRD42022362379; registered October 09, 2022.